| 1 | RACKS 2U with rack fixing, crimping and end terminations of patch panel fixing, 24 port switch fixing, termination ofpatch panel and 24 port switch using 1 mt patch chord and commissioning of the network |
| 2 | RACKS 4U with rack fixing, crimping and end terminations of patch panel fixing, 24 port switch fixing, termination ofpatch panel and 24 port switch using 1 mt patch chord and commissioning of the network |
| 3 | RACKS 8U WATERPROOF IP66- OUT DOOR with rack fixing, crimping and end terminations of patch panel fixing, 24 port switch fixing, termination ofpatch panel and 24 port switch using 1 mt patch chord and commissioning of the network |
| 4 | RACKS 6U with rack fixing, crimping and end terminations of patch panel fixing, 24 port switch fixing, termination ofpatch panel and 24 port switch using 1 mt patch chord and commissioning of the network |
| 5 | RACKS 9U withrack fixing, crimping and end terminations of patch panel fixing, 24 port switch fixing, termination ofpatch panel and 24 port switch using 1 mt patch chord and commissioning of the network |
| 6 | PVC Casing caping with installation per Meter |
| 7 | PVC Casing caping with installation per Meter |
| 8 | CAT 6A UTP Cable(PerMtrs ) with laying, termination &installation |
| 9 | SOLID CABLE CAT 6, 4 PAIR,UTP-per Mtrs with laying, termination &installation |
| 10 | Cat 6 SFTP , shileded cable for protection against power cable , other cableinterference |
| 11 | CAT 6 DOUBLE JACKET FOR OUTDOOR OPEN WIRING |
| 12 | Armoured CAT 6A UTP Cable(PerMtrs ) with laying, termination &installation |
| 13 | Modular Switch Plate: 2M Module |
| 14 | Modular Switch Plate: 4M Module |
| 15 | Modular Switch Plate: 6M Module |
| 16 | Modular Switch Plate: 8M Module |
| 17 | Modular Switch Plate: 12M Module |
| 18 | Modular Surface Box: 2M Module |
| 19 | Modular Surface Box: 4M Module |
| 20 | Modular Surface Box: 6M Module |
| 21 | Modular Surface Box: 8M Module |
| 22 | Modular Surface Box: 12M Module |
| 23 | Modular Electrical switches: 6 Amp |
| 24 | Modular Electrical Socket: 6 Amp |
| 25 | Modular Electrical switches:combination of 6 x 16 Amp |
| 26 | Modular Electrical socket:combination of 6 x 16 Amp |
| 27 | Electrical copper wire: 2.5, sq mm with insatallation per metre |
| 28 | Electrical copper wire: 4, sq mm with insatallation per metre |
| 29 | 3 core 6 sq.mm. Electric Cable with installation per mtr. |
| 30 | 2 Core Speaker Wire with installation per mtr. |
| 31 | 4 Way MCB Box with installation |
| 32 | 8 Way MCB Box with installation |
| 33 | MCB- 63 Amp |
| 34 | MCB- 40 Amp |
| 35 | SFP Trancereciver sm |
| 36 | SFP Trancereciver sm 10G |
| 37 | SFP Trancereciver sm 10G Copper |
| 38 | UTP to fiber transceiver 1Gbps with ST |
| 39 | UTP to fiber transceiver 1Gbps with SC |
| 40 | 1000 Base SX-transceivers with LC connector mm |
| 41 | 1000 Base SX- transceivers with LC connector sm |
| 42 | 1000 Base TX transceivers for copper |
| 43 | 10/100/1000 ethernet LAN extenders on Copper pair |
| 44 | 10/100/1000 ethernet LAN extenders on optical fiber (SX) |
| 45 | Patch Cord,SM(OS2), Duplex LC-SC,PC Type 3M |
| 46 | Fibre Drawer,LIU, Loaded,24SM,SC or LC Sx adapter |
| 47 | Fibre Joint Box |
| 48 | Pigtail,SM, Simplex SC Type 1M |
| 49 | Earthing |
| 50 | HDPE Pipe Per Mtr |
| 51 | 1KVA Voltage Stabilizers |
| 52 | 1MeterDual Ended MountingUTP Cat 6 patch Cord |
| 53 | 3 Meter (s) Dual Ended MountingUTP Cat 6 patch Cord |
| 54 | Single Mode (OS2) Unitube, Armoured 6 Core, HDPE |
| 55 | Creation of LAN Point |
| 56 | 6 Core armored cable –MM |
| 57 | 12 Core armored cable –MM |
| 58 | 24 Core armored cable –MM |
| 59 | 48 Core armored cable –MM |
| 60 | 6vCore outdoor armored cable –SM |
| 61 | 12Core outdoor armored cable –SM |
| 62 | 24Core outdoor armored cable –SM |
| 63 | 48Core outdoor armored cable –SM |
| 64 | 4 Core Fibre Cable unarmoured-SM |
| 65 | 6 Core Fibre Cable unarmoured-SM |
| 66 | 12 Core Fibre Cable unarmoured-SM |
| 67 | 6/12/24/48 CoreFibre Cable With(A) :Laying & fixing Fiber Cable.- Underground. |
| 68 | 4/6/12/24/48 CoreFibre Cable With (B): Laying & fixing of OutdoorArmoredFiber Cable - Arieal. |
| 69 | 6/12/24/48 CoreFibre Cable With ( C ):Fixing & Layingfiber Cable in Gi/steel Piping of 10 m.m.when passing through tar/concrete road. |
| 70 | 6/12/24/48 CoreFibre Cable With ( D ): Fixing of Fiber Cable in High density (HD) pipe of 30 MMwhen layed under soil. |
| 71 | 4 Port OLT |
| 72 | 8 Port OLT |
| 73 | 16 Port OLT |
| 74 | 1G/EPON 1GE ONU |
| 75 | Fiber Splitter without connector 1 |
| 76 | Fiber Splitter without connector 2 |
| 77 | Fiber Splitter without connector 3 |
| 78 | Fiber Splitter without connector 4 |
| 79 | Fiber Splitter with connector 1 |
| 80 | Fiber Splitter with connector 2 |
| 81 | Fiber Splitter with connector 3 |
| 82 | Fiber Splitter with connector 4 |
| 83 | Fiber Splitter cassette Type 1 |
| 84 | Fiber Splitter cassette Type 2 |
| 85 | Fiber Splitter cassette Type 3 |
| 86 | Fiber Splitter cassette Type 4 |
| 87 | Fiber Splitter cassette Type 5 |
| 88 | Fiber Splitter cassette Type 6 |
| 89 | Optical Distribution Frame 1 |
| 90 | Optical Distribution Frame 2 |
| 91 | Optical Distribution Frame 3 |
| 92 | Optical Distribution Frame 4 |
| 93 | Optical Distribution Frame 5 |
| 94 | Optical Distribution Frame 6 |
| 95 | Route Marker |
| 96 | Fiber Splice Box |
| 97 | Outdoor enclosure/Rack |
| 98 | 155Mbps BIDI SFP Transceiver for OLT |
| 99 | 20KM Dual Fiber SFP for OLT |
| 100 | 20KM Gigabit Single Core SFP for OLT |
| 101 | 1KVA UPS with 30 minutes backup |
| 102 | 3KVA Online UPS with Built in Battery |
| 103 | Service Engineer |
| 104 | Fibre Termination: Install, test and commission of Optical fibre termination. The work shall include for all labour of fibre spicing and end terminations with proper tools as per the company standards. (1 core=2 fusion for fibre spicing).It also includes fixing of LIU, transreceiver, Fibre Patch Cord LC-SC Type, Fibre SM Pig Tails LC, LC Adapters, Fiber to copper converter in rack. |
| 105 | Earthwork in excavation in foundation, pipeline trenches, drain (not exceeding 1.5m in width or 10 sq.m. on plan) in all types of stratas comprising of any type of materials such as soil, silt clay, sand, gravel, murrum of all types of conglomerates, laterite rock, soft rock, ordinary rock, disintegrated rock, fissured / shattered rock, decomposed rocks, weathered rock, etc and all such other materials either in full or part as the case may be adopting any method / methods as may be convenient or permitted including chiseling, wedging etc. in all conditions such as dry, moist, foul, saturated, submerged etc. as directed by Engineer etc. all complete including refilling, dressing of sides, ramming of bottom, including all lead and lift, including getting out the excavated soil as directed including pumping and bailing out water, barricading danger, lightening, guarding as directed by Engineer upto depth of 1.5m (Blasting Prohibited). without ROW/Permissions |
| 106 | Cutting the bituminous road for laying the pipeline in trenches for a width of 0.6mincluding labour, tools, etc. and disposing the excavated excess material from the trench to a distance of 1000 metres, including making level the trench surface by utilising the serviceable material to the level of the top surface of road,by compacting, watering ramming with rolling with road rollerafter completion of laying of pipe and refilling the trenches etc. complete as per the direction of engineer in charge.: By Mechanical Means: District Road, State highway, National highway without ROW/Permissions |
| 107 | Earthwork in excavation in foundation, pipeline trenches, drain (not exceeding 1.5m in width or 10 sq.m. on plan) in all types of stratas comprising of any type of materials such as soil, silt clay, sand, gravel, murrum of all types of conglomerates, laterite rock, soft rock, ordinary rock, disintegrated rock, fissured / shattered rock, decomposed rocks, weathered rock, etc and all such other materials either in full or part as the case may be adopting any method / methods as may be convenient or permitted including chiseling, wedging etc. in all conditions such as dry, moist, foul, saturated, submerged etc. as directed by Engineer etc. all complete including refilling, dressing of sides, ramming of bottom, including all lead and lift, including getting out the excavated soil as directed including pumping and bailing out water, barricading danger, lightening, guarding as directed by Engineer upto depth of 1.5m (Blasting Prohibited). with ROW/Permissions |
| 108 | Cutting the bituminous road for laying the pipeline in trenches for a width of 0.6mincluding labour, tools, etc. and disposing the excavated excess material from the trench to a distance of 1000 metres, including making level the trench surface by utilising the serviceable material to the level of the top surface of road,by compacting, watering ramming with rolling with road rollerafter completion of laying of pipe and refilling the trenches etc. complete as per the direction of engineer in charge.: By Mechanical Means: District Road, State highway, National highway with ROW/Permissions |
| 109 | Repairs and reinstatementto the road for trenches made by laying water supply pipeline, by removing the refilled material in the trenchfor thetotal depth of 0.42m and making good the road surface by providinglaying rolllingby road roller compactingfor laterite soling 30cm thick, two layer of full grout of 50mm thick each, tack coat and open graded premix carpet of 20mm thickness |
| 110 | Construction of masonry chamber 90x90x100 cm inside in 40kg/sq. cm brickwork complete with 23 cms wall thickness and in cement mortar 1:4( 1 cement : 4 coarse sand) for sluice valve of sizes 100 mm, 120 mm 150 mm and 200mm diawith necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 coarse sand: 10 graded stone ballast 40 mm nominal size) andinside plastered with CM 1:3 ( 1 cement : 3 coarse sand)finished with floating coat of neat cement complete and chamber cover as specified below etc. all complete as per standard drawing . (rate is inclusive of rate earthwork excavation, cost of surface coverand all other materials and labour and as per details below) : Without surface box and with 120 mm thick R.C.C. slab coverin cement concrete 1:2:4 ( 1 cement: 2 coarse sand: 4 graded stone ballast 20 mm nominal size) |
| 111 | Providing at store or site work non-pressure RCC pipes of with collarjoints conforming to IS:458-2003includingfreight, carting, loading,unloading, stacking etc. complete. : NP2 Class : 300mm |
| 112 | Laying and fixing with collars light duty non-pressure NP 2 class R.C.C. pipes with cement mortar in proportion 1:2 (1 cement : 2 fine sand) in joints including cost of jointing material etc. complete. : 300 mm dia pipe |
| 113 | Removal of Old cabling work including shifting/ rework, Bidder is required to remove the same & shift at new place or at ITG store. For shifting of material for more than 1 Km, ITG will pay actual transportation cost. |
| 114 | Re-installation and commissioning works that includies shifted items (racks, patch chords, patch panels switches, any other items, etc) |
| 115 | Electrical Termination Point (A): Install, test and commission of 1 no of 16A socket and switch with moulded modular ploycarbonate surfacebox and moulded modular ploycarbonate switch plate including the termination of wires. |
| 116 | Electrical Termination Point (B): Install, test and commission of 3 nos of 6A socket & switch and 1 no 6 x 16A universal socket & 6 A switch with moulded modular ploycarbonate surface box and moulded modular ploycarbonate switch plate including the termination of wires. |
| 117 | Electrical Wire Laying (A): Fixing & Laying of electrical wiring in PVC casing from client node to UPS output. |
| 118 | Electrical Wire Laying (B): Fixing & Laying of electrical wiring in PVC casing from input/output MCB’s to main line. The work also shall include the termination of MCB’s. |