| 1 | Dismantling Brick / stone masonry in Cement mortar walls under 3m high |
| 2 | Dismantling of AC Sheet Roofing without roof timbers |
| 3 | Chipping of concrete and roughening the surface |
| 4 | Pressed Tiles & Weathering Course |
| 5 | Dismantling Doors and Windows including removal of frames, hinges and fastenings |
| 6 | Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification |
| 7 | Supplying and filling in foundation, basement, etc with filling M.Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 8 | Supplying and filling of Red gravel by lorry in basement filling including conveyance loading and unloading charges and all other incidential charges filling laying watering and consolidation etc., complete as directed by the Dept., Officers with standard specification. |
| 9 | Cement concrete 1:5:10 (One cement five sand and ten brokenMachine crushed stone jelly) using HBG Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete |
| 10 | Plain Cement Concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. |
| 11 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. |
| 12 | Providing Groove cutting in flooring concrete for 10mm width and 20mm depth and filling the groove with combination of anabond tuffseald 2G & bitumen tar including cost of all materials and labours etc complete. |
| 13 | Brick Workin Cement Mortar 1:5 (One Cement and Five Sand)using Ground moulded Chamber Bricks IInd class of size 9”x4 3/8”x2 ¾”including curing etc., complete complying with standard specification. |
| 14 | a) Foundation and basement |
| 15 | Plastering with Cement Mortar 1:5, 12mm thick in all floor including curing etc.complete complying |
| 16 | Special ceiling plastering and finishing all the RCC exposed surface such of RCC slabs sunshade, canopy, staircase steps landing slabs etc., with CM 1:3 (One of Cement and three of sand) 10mm thick |
| 17 | Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. |
| 18 | Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. |
| 19 | Manufacturing, supplying and fixing of Steel Door (Single Leaf) with following specification.MS angle of size 40 x 40 x 6mm at 3.5 kg/m used for outer frame and MS Angle of size 35 x 35 x 5mm at 2.6 Kg/m for the shutter frame.Stiffeners with 32 x 6mm at 1.5 Kg/m MS Flat is provided as the lock rail of the door and welded intact on both ends to the shutter frame. 18 gauge CR Sheets of best quality is laid as panel in the shutter frames.18 x 5mm at 0.70 kg/m MS flat is welded over the 32 x 6mm at 1.50 kg./m MS Flat on the rear side of the door, sandwitching the CR Sheet for rigidity.Additional stiffeners with 18 x 5mm at 0.70 kg./m MS flats are provided diagonally on the rear side of the shutter.300mm length of hinges 2 Nos, for shtter is provided.6 Nos. of 250mm length hold fasts 200mm length specified at the ends are welded to the outer frame of the door.Tower bolt 2 Nos. at the top provided.250 x 16mm size of two aldrops are provided in single leaf door at lock rail section in the door for inner and outer provided and one rotating locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place and 1 No. of MS handle of heavy duty. A tie bar is provided at the bottom of the outer frame to prevent twisting of the frame during transportation and fixing.All members are given one coat of red oxide primer as directed by the departmental officers.The rate includes cost of all materials, labour charges, transportation, taxes and all other incidental charges, etc., complete. |
| 20 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., |
| 21 | Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers |
| 22 | Supplying and painting the walls with two coats of Cement paint over one coat of cement primer as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specification |
| 23 | Re Painting the walls with Two coats with first class quality Plastic Emulsion paint ( Exterior) of approved colour over a priming coat including thorough scraping, clean removal of dirt. The rate includes cost of brushes, sand paper, plaster of parries, putty wherever required and neat finishing etc., |
| 24 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 25 | Painting two coats old iron work for doors, windows and ventilators using iron bars, window grills weld mesh screen in open courtyard etc., with two coats synthetic |
| 26 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification |
| 27 | Painting old wood work with two coats of with best approved quality and colour synthetic enamel paint in all floors, the rate shall inclusive of all materials, brushes, |
| 28 | UPVC VentilatorSpecification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 29 | Supplying and fixing of rolling shutters with ISI mark shall be of pull and push type made out of 18/Gauge x3’’ lathe sections which consists of five main parts such as curtain, lock plate, guide channels rollers and hood cover. These five main parts are made out of special components detailed below; Curtain; Shall be of 18/Gx3\" lath sections cut to required size and filled with heavy cast iron/ M.S. Clips for 8\"0\"[2.45m] high rolling shutter lathe sections provided shall be not less than 37 numbers. Lock Plate; Shall be 10gaue M.S.Sheet reinforced with 40mmx 6mm M.S angles at the bottom and fitted with heavy latches of 12mm thick locking arrangements on either sides.There should be one handle on either side Guide channel; Pressed guide channels shall be of 10 gauge M.S.Sheet and attached to the side brackets with 20mm square bar. Side brackets shall be of 10 Gauge angle M.S.Plate and cost iron \"U\" clamps shall be reveted to the side brackets Roller; Shall be of heavy cast iron pullies fitted with heavy duty C\" Class 40mm steel pipes and high tensile high carbon coil springs-2 springs shall be supplied. Supplying and fixing of Hood Cover; Shall be of 0.9mm CRCA sheet reinforced with 25mm x 25mm x 3mm M.S. angle or gate channel. The rolling shutter in addition to the above should have pulling hook and shall be coated with heavy coat of zinc chromite primer. The above specifications for various components of rolling shutter shall be invariably followed and verified with the rolling shutters supplied by the firms at site. If the rolling shutters supplied do not confirm to the above specifications, the concerned firms should be asked to replace the shutter or supplythe missing components |
| 30 | Supplying and laying of Gal volume sheet 0.47 mm thick of approved quality for roofing with necessary U or J bolts and unts bitumen GI washers etc., complete complying with standard specification. |
| 31 | Supplying and laying of Gal volume sheet ridge pieces approved quality with necessary U or J bolts and nuts GI washers etc., complete complying with standard specification. |
| 32 | Supplying and fixing AC sheet roofing with 6mm thick asbestos cement sheets of fully corrugated (grey colour) of approved quality by drilling holes (and not by punching) with necessary ‘J’ / ‘U’ bolts and nuts of 8mm dia of suitable length and providing one set of bitumen washers of 25mm dia and 1.60mm thick for each bolt including protruding portion of bolts in roof shall be covered with bitumen compound etc., |
| 33 | Asbestos Cement Adjustable Ridges |
| 34 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm colour glazed earthern ware of approved quality and brand with \"P\" or \"S\" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., |
| 35 | Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm \"P\" or \"S\" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc |
| 36 | Supplying and fixing in position 15mm dia brass CP screw down tap/Pillar tap (heavy duty) of approved make |
| 37 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications |
| 38 | a).160mm dia PVC soil / waste pipes |
| 39 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes of 110mm dia., having a pressure of 4 kg. / sq.cm including cost of necessary PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. |
| 40 | Supplying, laying and joining the following size of UPVC pipes (Internal ) of approved quality and best verity conforming to ISS and with ISI Mark laid properly to alignment including cutting, threading and fixing UPVC specials but excluding the cost of such specials and fixing to the wall with necessary TW plugs, UPVC clamps and screws, making holes on the wall or drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work, concrete and plasteringwherever necessary with necessary scaffolding charges etc., complete.. |
| 41 | a). 25mm dia UPVC Pipe |
| 42 | b). 32mm dia UPVC Pipe |
| 43 | Supplying, laying and joining the following size of UPVC pipes Specials of approved quality and best verity conforming to ISS and with ISI Mark laid properly to alignment including cutting, threading and fixing necessary with necessary scaffolding charges etc., complete.. |
| 44 | a). 25mm dia Elbow |
| 45 | b). 25mm dia Tee |
| 46 | c). 25mm dia Bend |
| 47 | d). 25mm dia Coupler |
| 48 | e). 32mm dia Elbow |
| 49 | f). 32mm dia Tee |
| 50 | g). 32mm dia Bend |
| 51 | h). 32mm dia Coupler |
| 52 | Supplying and fixing in position first quality & approved variety of Gun metal Gate Valve / Wheel Valve |
| 53 | Supplying and fixing of 1000 Litres capacity syntax tank with IS specification IS 10701/96 the tank is meant for outdoor (or)indoor use complete with removable hinged top locking arrangement and to make provision to fix water supply pipe lines, necessary man hole with cover and including all PVC specials pugs, screws nails to fix the tank etc., complete and the tank should fixedfirming as directed by the departmental officers. |
| 54 | Wiring with 2 x 1.5sq.mm(22/0.3) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box inflush with wall with 5A F.T. switch,covered with hylem sheet of 3mm thick with painting of suitable colour with continous earth wire connection of 14 SWG TC wire for making good of the concealed portion for PVC concealed light point/fan point.(For Electronic Regulator) ( SD No - 16 ) |
| 55 | Supply and run of 2 of 4sqmm (56/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour.( SD No - 57 ) |
| 56 | supply and fixing of 30W LED street light fitting with LED (Higher end) with 25 mm dia. GI pipe (class B) with 1 no. 25 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .( SD - 532 ) |
| 57 | Supply and fixing of single box type 4\"40W fluorescent fitting complete with copper choke and condensor with conduit pipe suspension from the ceiling with PVC unsheathed copper leads from terminals to the fitting with tube ( SD.No - 89 ) |
| 58 | Supply and fixing of 1200 mm (48\") sweep AC ceiling fan complete with stepped electronic 300Wregulator with 1 m down rod with fan clamp with side plates & cross arm of size 450mm ( 18\" ).SD-106 |