| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-10-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-10-2024 |
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposing the rubbish off the premises complete all as specified and as directed. |
| 2 | M&L for coloured glazed ceramic tiles in vertical surface of size 450X 300X 7 mm thick over 10 mm thick back coat of cement mortar in (1:4)set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and as directed. |
| 3 | M&L for prepolished chequered cement concrete tiles of size 20cm x 20cm x 25mm thick, as in floors etc,including 15 mm thick screed bed or bedding in cement mortar (1:4) and set and jointedin neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed. |
| 4 | M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and as directed. |
| 5 | M&L forgranite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of graniteincluding 15 mm thick screed bed in cement mortar (1:4) complete all as specified and as directed. |
| 6 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness. (below or above ground level) complete all as specified and directed. |
| 7 | M&L for 75 mm thick,plain cement concrete(1:3:6) typeC-1 (using 20mm graded stone aggregate) as in plinth protection, footpath, hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) making impressions of expanded metal whilst the concrete is green complete all as specified and as directed. |
| 8 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets and frame work any type complete all as specified and as directed. |
| 9 | S&F for GI snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 6 mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation and acoustic purpose fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and as directed.Make of E-Board : Eternit Everest / Lafarge/ Armstrong/Visaka Industries Ltd. |
| 10 | M&L for 40mm thick, PCC (1:2:4), type B-1 (using 20mm graded stone aggregate) as in sub base of floor etc andfinished even and smooth without using extra cement complete all as specified and directed. |
| 11 | M&L for 38 mm wide, Aluminium dividing strips, 1.5mm thick, inserted in position, conform to design complete all as specified and directed. |
| 12 | Demolition of lime concrete/ lean concrete/ brick bats from sunken portion exc. 15 cm thickness (above ground level), including removal of rubbish outside MoD land, complete all as specified anddirected. |
| 13 | M&L for water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:-(a) Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100 m n. exc,250m.(b) M&L 25 thick cement concrete type BO 1:2:4(12.5 mm graded aggregate) finished even and smooth.(c) M&L for 15 mm thick plaster/screed bed in cement mortar (1:4) finished even and smooth.(d) Preparing & cleaning of fully dried cement plastered surface.(e) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 litres per sqm conforming IS-3384.(f) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction.(g) One coat of aluminium paint over APP membrane @0.11Kg/Sqm.Note:- Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab. |
| 14 | Material and labour for PCC (1:2:4), type B-1, using 20 mm graded mechanically crushed stone aggregates,as in padding concrete to sunken floor, covering to junction of floor and vertical walls includingchamfering on edges, complete all as specified and directed |
| 15 | M&L for plain cement concrete (1:5:10),type E2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed. |
| 16 | S&F in repairs vitreous China squatting pan, \"Orissa\"pattern, size 580 x 440 mm white with integral foot rest and \"P\" or \"S\" trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor using concrete (1:2:4) type B0 and to match with existing specifications complete all as specified and as directed. Make : Cat No. C0117 of Parryware/Hindware/Cera. |
| 17 | S&F in repairs,PVC low level flushing cistern, 10 litre capacity, valveless, symphonic action type with inlet, ball valve, float and handle incl bracket, PVC conection pipe andflush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specified and directed |
| 18 | S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, including connection to outgoing drain andflushing pipe, anti syphonic pipe including PVC seat and cover complete but excluding flushing cistern & flush pipe including making good to disturbed surfaces of floor using concrete (1:4:8) type D2 and to match with existing specifications complete all as specified and as directed. |
| 19 | S&F in repair vitreous china bowl urinal bowl type, of size 465x355x265mm, white (minimum) with grating and union for discharge pipe (excluding flushing cistern but including flush pipe & waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and as directed. |
| 20 | S&F in repairs vitreous china wash basin, size 550 x 400mm, white, flat back, including 32mm bore PVC (HDPE) waste pipe 450mm long, 32mm bore CP waste coupling, chain, plug and porcelain stopper & brackets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed. |
| 21 | S&F in repair bib taps fancy type CP with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule and fixed of size 15mm bore in repair complete all as specified and as directed. |
| 22 | S&F in repair 15 mm bore, stop valves,cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unionscomplete all as specified and as directed. |
| 23 | S&F in repair 15 mm bore pillar taps, cast copper alloy, chromium plated, fancy type with capstan heads, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed. |
| 24 | S&F in repair 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and as directed. |
| 25 | S&F in repair 600mmX450mm bevelled edge mirror of selected quality 5mm thick glass, mounted on PVC frame including key hole plates for hanging and fixed to wall with chromium plated cup washers and screws complete all as specified and as directed. |
| 26 | Taking up or down 15mm bore existing steel tubing and connections including cleaning for refixing or removal to stores complete all as specified and as directed. |
| 27 | Taking up or down 20mm bore existing steel tubing and connections including cleaning for refixing or removal to stores complete all as specified and as directed. |
| 28 | Refixing of 15mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete obtained from item above respectively as directed. |
| 29 | Refixing of 20mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete obtained from item above respectively as directed. |
| 30 | Supply, laying, connection and testing, 15mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and as directed. |
| 31 | Supply, laying, connection and testing, 20mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and as directed. |
| 32 | Demolition of cement concrete of any description andin any position not specifically provided for complete all as specified and as directed. |
| 33 | M&L for reinforced cement concretetype B-0 (1:2:4) (using 12.5 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, etc complete all as specified and as directed. |
| 34 | S&Fform work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed. |
| 35 | S&F for TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 36 | M&L for mild steel TMT bars 6 to 8mm dia and over ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 37 | Disconnecting waterstorage/service tank (RCC/PVC tank) exc 250 Litre but not exc 500 Litre capacity, cleaning and removing all scales Dirt, etc from Tank and mouths of circulating and wash out pipes of Tank with bleaching power. Re-hoisting in same position and re-connecting,including Re-writingwith synthetic enamel paint DATE OF CLEANING and DUE ON complete all as specified and as directed. |
| 38 | Dismantling water storage tank exc 250 & n.exc 500 ltr capacity and removing from site, complete all as specified and as directed. |
| 39 | Dismantling water storage tank exc 500 & n.exc 1000 ltr capacity and removing from site, complete all as specified and as directed. |
| 40 | S&F for 500 litres capacityrotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe including20 mm bore, ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight - 210 gms) complete all as specified and as directed. |
| 41 | S&F for 1000 litres capacityrotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe including20 mm bore, ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight - 210 gms) complete all as specified and as directed. |
| 42 | S&F in repairs 20 mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and as directed. |
| 43 | S&F in repairs 20mm bore gun metal gate valve with iron wheel head, screwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 44 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 45 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 46 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and as directed. |
| 47 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed |
| 48 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces as in walls in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 49 | M&L for rendering 15 mm thick in cement mortar (1:4) on other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 50 | M&L for rendering 5 mm thick on ceiling in cement mortar (1:3) finished even & smooth without using extra cement complete all as specified and directed |
| 51 | S&F in repairs 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. |
| 52 | Dismantling of 100mm bore, cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and as directed. |
| 53 | S&F for 110mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls complete all as specified and as directed. |
| 54 | S&F in repairs 75mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls complete all as specified and as directed. |
| 55 | S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 56 | S&F for 75 mm bore, PVC (SWR) junction single (Single T) equal or unequal with access door complete all as specified and as directed. |
| 57 | S&F for 110 mm bore, PVC (SWR) vent cowlfixed with solvent cement complete all as specified and as directed. |
| 58 | S&F for 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed. |
| 59 | S&F in repairs flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and as directed. |
| 60 | S&F in repairs PTMT(half or full threaded) waste coupling 32mm for sink (min weight 32mm - 45gms / 40mm- 60gms) complete all as specified and as directed. |
| 61 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or steel frames, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed. |
| 62 | S&F for 3 mm thick, sheet glass,ordinary quality and glazing with oil puttyin square not exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 63 | S & F sheet glass 4.0mm thick selected quality and glazing with oil putty / beads in squareexc 0.50 Sq.m in each pane, all as specified and directed. |
| 64 | Supply and fixing in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 65 | S&Fvitreous china Semi pedestal pattern (Anglo Indian type) whiteconnection to trap \"P\" or \"S\" and flush pipe etc seat cover and making good to disturbed surfaces of floor by filling with PCC 1:4:8 type D-2 to match with existing includingtaking down the existing old one all asspecified and as directed. |
| 66 | M&L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed. |
| 67 | M&L for preparation of newly plastered surface of walls etc and applying two coats of white washonwalls complete all as specified and directed |
| 68 | M&L for preparation of newly plastered surfaces of ceilings and applying two coats ofwhite wash complete all as specified and as directed. |
| 69 | M&L for Complete removal of existing tretment and preparation of old decorated plastered surfaces of walls, cornices etc by brooming down or steel wire brushing, scraping down with steel scraper, smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying two coat of white wash including necessary scaffolding complete all as specified and as directed. |
| 70 | M&L for preparation old decorated plastered or unplastered surfaces of wall cornices etc by brooming down or steel wire brushing, scraping down, the surfaces covered by smoke soot, growth of moulds and moos, efflorescent, having oil and gresase spots and applying two coat of cement base paint (white or tinted) including necessary scaffolding complete all as specified and as directed |
| 71 | Taking down chowkats or frame exceeding 1.5 Sqm and not exceeding 4.00 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and as directed. |
| 72 | Taking down chowkats or frame not exceeding 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and as directed. |
| 73 | Refixing shutters of any description exceeding 1.0 sqm but not exceeding 2.0 sqm each in the same opening complete as directed. |
| 74 | Refixing shutters of any description not exceeding 1.0 sqm each in the same opening complete all as specified and as directed. |
| 75 | S&Fpressed steel frames for doors of size 125x60mmwith one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including providing and fixing necessary lugs, 100mm butt hinges, lock strike plate,shock absorber etcand including PCC filling of hollow section using plain cement concrete (1:3:6) type C1 complete all as specified and as directed. |
| 76 | Supply and fix mild steel work as in Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde E-165 complete all as specified and as directed |
| 77 | M&L for mild steelframed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 Gde (E-165) complete all as specified and as directed. |
| 78 | S&F for solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed. |
| 79 | S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails.MS frame shall be covered with heat moulded, plain colour PVC \"C\" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, complete all as specified and as directed by Engr-in-Charge. |
| 80 | S&F 35 mm thick, second class hard wood, glazed and skeleton shutters with open rebated and prepared to receive glass, gauze, etc (without sash bars)edges of framing plain, chamfered or rounded, fitted with cut mitered beads for securing glass, etc, sizes of members of shutters as specified in SSR Part I, Section -8, clause 8.24 (a), complete all as specified and as directed. |
| 81 | M&L for 35mm thick second class hard woodplain, framed, panelled shutters (any number of panels), with panels of 12mm thick veneered particle board mediumdensitywith commercial face veneers: supplied and fitted to chowkats, sizes/section of members of shutters shall be as specified in SSR Part I, Section -8, clause 8.24 (a) complete all as specified and as directed. |
| 82 | S&F in repair steel windows with side double hung shutters including projecting /box type hinges with steel handle, and steel peg stay complete with glazing bars, devotailed or welded complete all as specified and as directed. |
| 83 | S&F in repair steel windows with side double hung shutters including projecting /box type hinges with steel handles and steel peg stay complete without glazing bars, dovetailed or welded complete all as specified and as directed. |
| 84 | S&F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified complete all as specified and as directed. |
| 85 | S&F for anodised aluminium door shutter frame work fabricated by using medium grade, Jindal Make box sections ofAluminium section. door/partition panels shall be 8mm thick plain select quality glass panes inserts, fixed with aluminium anodises glazings clips and rubber beading andAluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples includingall standard accessories. etc complete all as specified and as directed. (Ref TD drawingCESZ/2015/TD-007) |
| 86 | S&F anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 87 | S&F for stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 88 | S&F in repair 12mm thick prelaminated particle board, interior grade, both side with decorative choice lamination fixed with screws to timber frame works as in shutter of cup board and other similar work complete all as specified and as directed. |
| 89 | S&F for 100 mm size, butt hinges, heavy weight, cold rolled mild steel complete all as specified and as directed. |
| 90 | S&F for 75mm size, butt hinges, heavy weight, cold rolled mild steel complete all as specified and as directed. |
| 91 | S&F for 150mm long aluminium, barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and as directed. |
| 92 | S&F for 100mm long aluminium, barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and as directed. |
| 93 | S&F for 150 mm size, auminium handles, cast type, anodised to a bright natural, mat finish complete all as specified and as directed. |
| 94 | S&F for 100 mm size aluminium handles, cast type, anodised complete all as specified and as directed. |
| 95 | S&F for aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sectionsor cast aluminium alloy, length of bolt of 250 mm anodised finish complete all as specified and as directed. |
| 96 | S&F in repair mild steel, 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed. |
| 97 | S&F in repairs curtain rails, Harrison rail, aluminium alloy with fixing brackets, stops, rollers etc complete all as specified and as directed. |
| 98 | S&F in repairs 150 mm Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed to door complete all as specified and as directed |
| 99 | S&F in repair aluminium (die cast body) door closer hydraulically regulated, designation No.3, universal type suitable for shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed. Make: Godrej C071 950 mm or equivalent make as per Appx |
| 100 | M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed. |
| 101 | M&L for preparation of oldpainted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 102 | M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer including necessary scaffolding complete all as specified and as directed. |
| 103 | M&L for preparation of old wooden surfaces of any description, exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete as specified and as directed. |
| 104 | Supply only integral water proofing compound complete all as specified and as directed. |
| 105 | Demolition of reed, lathing, single or double including battens and plaster or chicken wire lathing complete all as specified and as directed. |
| 106 | M&L for GI wire netting of 0.90mm dia and 12mm mesh lathing to wood or metal studding, joist etc in walls, ceilings etc including all laps, cutting and waste fixed with tinned tacks of wire staples complete all as specified and as directed. |
| 107 | M&L for rendering 15 mm thick on one side of lathing in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 108 | M&L for rendering 10 mm thick on other side of lathing in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 109 | M&L for granite stone slab (of any type) 20 mm thick, machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed or bedding in cement mortor (1:6) and cutting, polishing complete all as specified and as directed. |
| 110 | M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. |
| 111 | S&F for 0.80 mm thick, galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with L-type or J-type or cranked hook bolts and washers, in roofs, with grade of zinc coating 275, conforming to IS -277-2003 complete all as specified and as directed. |
| 112 | S&F for 1mm thick 150mm dia, Mild steel sheet eavesgutters, galvanised class 3, half round with rounded edges complete all as specified and as directed. |
| 113 | M&L for glass dividing strips, 3 mm thick and inserted in position, conform to design complete all as specified and directed. |
| 114 | Dismantling of asbestos cement (corrugated or semi corrugated) sheets in roof coverings including ridges complete all as specified and as directed. |
| 115 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges complete all as specified and as directed. |
| 116 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 117 | S&F for pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed.Note : Colour of ridge shall be same colour as that of sheet used for roof. |
| 118 | Supply and fix ball brass valve, high pressure and high density, polythene float & fly Nut complete screwed for iron pipe of 20mm bore. |
| 119 | S&F in repair, towel rail, 600mm long of PTMT fixed with and including chromium plated brass screwand wooden plastic cleats (minimum weight 190 gms) complete all as specified and as directed. |
| 120 | S&F in repairs brass chromium plated shower rose 125mm size with shower arm 15mm size 150mm long with bend, including fixing to steel pipe or union complete all as specified and as directed. |