Special Repair/Renovation Of Civil And Electrical Work Building No.339 Inside Factory Gcf Jabalpur.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling Asbestos cement (corrugated, semi corrugated etc.) sheets in roof covering and stacking properly as directed. |
| 2 | Taking down eaves gutters/Valley gutter and rainwater pipes (any size or pattern) including all fitting, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the center line over fitting and accessories). |
| 3 | Taking out old serviceable glass of any description from old wooden or metal frames, or stone, concrete or brick surrounds, any thickness or size; hacking out old putty or removing beads etc. including making good breakages in taking out & handing removing to store or stacking for reuse. |
| 4 | Dismantling Wrought Iron or Mild Steel work of any description including door, gate cladding etc all as directed (Rusted portion of MS structure by cutting) |
| 5 | S&F Rolled Mild Steel Roof trusses (framed), trussed purlinscrane gantries, rails & fastenings & heavy bracket framing (Beam, tee, angle channel or flat sections). Distance pieces , cleats etc. including fabrication/welding complete all as directed Fe410-Gde-250 Quality-B with a coat of Zinc Chromate primer paint (including preparation of surface). |
| 6 | M&L for painting of whole structure including all truss, purlin, stanchion, cladding structure, gates and all members with coat of aluminum paints over a coat of primer including preparation of surface. The contractor must see site before quoting the rate as the whole work is to be carried as per site condition. The work includes painting of structure up to height of 20.00 meters. |
| 7 | S&F Pre-painted Galvalume Aluminum Zinc coating GI based steel sheet 0.50mm thick of approved colour , having tensile strength of 550 Mpa, Double ribbed Trapezoidal Profile, Effecting Cover Width 975mm and Overall Width 1057mm, as in roof covering/wall cladding etc. fixed with self-topping screws or L-type or J-type hook bolts as specified & directed. Is 15965 approved & marked. With latest marking declared by the manufacturer. Make: Tata Blue scope/Lloyd Insulation/Ispat/Jindal/Essar Only. |
| 8 | M&L pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of (AZ-150) any colour having tensile strength of 550 Mpa as in roof covering (ridges), drip & straight flashings, cladding to wall, fixed with self-tapping screws as specified (Make: Jindal, Tata as directed) |
| 9 | S&F of mild steel wind ties for roof including securing bolts; drilling holes including all necessary drilling, bolting or riveting, etc. as directed by EIC. |
| 10 | Providing and fixing of fire retardant and UV resistant profiled and solid transparent polycarbonate sheet minimum 2 mm thick to match with adjacent galvalume sheet on roof and cladding with self tapping screws or L type or J - type hook bolts as specified & directed . |
| 11 | Fixing of Turbo ventilator (provided by GCF) housed on PVC /FRP sheet (size approx 1 m x 3 m) |
| 12 | M&L for Brickworkwith subclass \"B\" bricks (normal size) straight or curved on plan exc 6m mean radius, built in cement mortar 1:4as directed by EIC. |
| 13 | M&L Rendering 15 mm thick cement plaster 1:6 on fair /unfair faces of brick work or concrete surfaces after taking down cement or cement lime plaster, any description including raking out joints, hocking for key, scrubbing down with water, etc as directed by EIC |
| 14 | M&L Rendering 15 mm thick cement plaster 1:6 on fair/unfair faces of brick work or concrete surface all as directed. |
| 15 | M&L PCC 70 mm thick type B-1, (1:2:4) using 20 mm graded stone aggregate in floor/plinth protection laid in panels including necessary formwork completed all as specified and directed. |
| 16 | M&L for Framed work as in doors or gates of angle or other section with gusset plates rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering.Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 290 (Gde-E-165) |
| 17 | S&F Mild steel, plain black sheet 1.00 mm thick in wall cladding, steel gates & similar work, cut to size, holes punched; including round headed screws, clout nails or rivets & fixing to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required all as directed by EIC/WIC. |
| 18 | M&L screed bed or bedding layer of mortar 25 mm thick for laying floor finishes in 1:6 cement plaster complete in all respect as directed. |
| 19 | M&L Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and joined with grey cement slurry mixed with pigment to match the shade of slab including cutting, rubbing and polishing by machine complete. |
| 20 | Site clearance: The area coming under cutting and filling shall be cleared of shrubs, vegetation, grass, bush, weed, trees and saplings not exceeding 30 cm in girth, measured at a height of one meter above ground level. Useful material shall be stacked and rubbish/useless material disposed off up to a distance 50 m outside the periphery of the area (soft loose soil) |
| 21 | Surface excavation n.exc 30 cm deep & averaging 15 cm deep and getting out in soft/loose soil. |
| 22 | M&L Hardcore of Broken stone/boulders gauge n exc. 63 mm, deposited, spread & leveled in layers n exc. 15 cm thick, watered & rammed to a true surface complete in all respect as directed. |
| 23 | Providing and fixing factory made rubber molded pigmented block with lacquer coated, hydraulically pressed mechanically vibrated and compacted precast interlocking premium paver blocks in M30 grade, 80 mm thickness of approved size/design of any colour (as approved by EIC) complete in all respect as directed. This item also included providing & laying of 50 mm thick stone grid bedding as cushion under the paver block as directed. |
| 24 | S&F for cement concrete kerb stone of M15 grade, factory made of size 300X300X125mm thick and complete as per direction of EIC. |
| 25 | M&L for Applying two coats of Exterior Weather coat premium Acrylic Emulsion (Make: Asian Apex Weather proof, Berger Weather proof, dulux Weather proof as approved by EIC) on old/new surfaces of brickwork, RCC surface after necessary preparation of wall surface and applying cement based primer all as directed. |
| 26 | Demolition of Brickwork or stone/bouldermasonry, built in Cement Mortar or cement lime mortar including all quoins, arches, pillars etc. |
| 27 | Demolition of cement concrete of any description & any position not otherwise specifically provided for as directed by EIC( un-reinforced) |
| 28 | Removing building material (other than spoil payable under items 3028to 3031 in section-3 Earthwork MES SSR 2020) to a distance of 300 m, lead included in the rates including loading unloading and stacking at the destination as dir. |
| 29 | S&Fplain, galvanized, mild steel sheeting 1.00 mm thick valley/ eave gutter, funnels, offsets, projections etc. for down take pipes (as per site condition & as directed) and similar work, cut to size, bending or turning up etc. as required holes, punched cut for down take pipe/s etc ; fixed with self tapping screws & leak proof washers to existing wood or steel framing with plain 120 mm lap joints welded seams (running & leak proof), all as specified & directed. (Zinc coating 275) |
| 30 | S&F of Bands, straps, supports or stays for rainwater, ventilating pipes including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinge large hasps and staples; chains hand made sliding bolts; clamps; hold fasts; wall ties hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafter; knee piece inserts; two way and three way straps plate washers and similar small articles conforming to Fe-290 Gde-E-165. |
| 31 | S&F UPVC pipe of 150 mm dia of pressure rating 6 kg/sq.cm fixed complete to walls, ceiling or in floor including necessary arrangement of fixing in gutters etc complete all as specified and directed. (clamp shall be measured & paid separately) (Make:Kasta, Plasto, Astral, Finolex) |
| 32 | S&F UPVC150 mm dia bends or elbow, square or abtuse complete all as specified and directed. |
| 33 | M&L Mild Steel TMT bars 10 mm dia& over cut to length, bent to shape required, including cranking bending etc & binding with & including mild steel wire not less than 0.9 mm dia all as directed. |
| 34 | M&L RCC type B1(1:2:4) using 20 mm graded aggregate in Foundations, including footings, foundation beams, bases for columns and mass concrete etc all as directed. |
| 35 | M&L PCC in foundations, filling and mass-concrete type B2 (1:2:4) using 20/40 mm graded stone aggregate. |
| 36 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, & steel peg stay, complete with glazing bars, dovetailed or welded. |
| 37 | S&F sheet glass 4.0mm thick, ordinary quality & glazing with oil putty in square n exc 0.5 sq. m in each pane. |
| 38 | S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing; framework of water tank & similar work conforming to Fe 290-0 Gde E-165 |
| 39 | Taking down carefully Copper /Aluminum Per Point wiring (light, fan, socket or power) complete, removing materials to store for keeping in safe custody for reuse at site and making good disturb surfaces of wall, floor etc |
| 40 | Dismantling and taking down oldunserviceable fluorescentover headtube light fittings single/double of any wattage or size, with or without TL, removing materials to store for taking credit. |
| 41 | Dismantling and taking down old unserviceable sodium vapor high bay light of any wattage or size for replacement removing materials to store for taking credit. |
| 42 | Dismantling and taking down old unserviceable Exhaust fan 450 mm of any wattage or size for replacement removing materials to store for taking credit. |
| 43 | Excavation of trench in soft soil, not exceeding 1.5 m wide and not exceeding 1.5 m in depthfor laying underground cable and getting out excavation earth as ordered. |
| 44 | Supply and laying precast cement concrete cable cover LV type -3 flat size 450mmx 180 mm x 40 mm |
| 45 | M & L sand filling (River sand) in trench 0.45 M in width and 0.10 M in depth ( 0.05 M below and 0.05 M over the cable) for providing protection to the cable. |
| 46 | Returning & filling of the excavated soil in trench including leveling, watering and well ramming in layers/ trench spreading. |
| 47 | M&L XLPE insulated, armored heavy duty electric cable with aluminum conductor, 1100 volts grade,3 & 1/2 core, cross-sectional area 300 Sq mmMake: Havells/Finolex/Universal/Polycab |
| 48 | Rough excavation in hard dense soil, exceeding 1.5 M for making earth chamber (0.90X0.90X2.5 M) per earth and getting out soil.(6 nos. earth) |
| 49 | M & earthing complete with galvanized steel pipeelectrode, 40 mm dia bore medium grade, 2.5 meters in length, buried directly in ground with top edge not less than 1.25 meters below ground level. Connected with galvanized iron 25 X 4 mm strip as earthing lead, all as shone in plate no. 2 Earth to be connected with earth test Per Point. All as specified in MES specification including pit chamber with removal type chamber cover. Testing on completion. ER value should be not more than 1 ohm. |
| 50 | M & L earth continuity conductor or main earth lead fixed on wall or concealed in wall along with conduit pipe/pipe batten recess or chassis buried in ground for loop earthing etc. as required 25 x 4mm galvanized iron strip. |
| 51 | S&F LT Main Panel made out of 3.15 mm thick CRCA sheet consisting of following items1. SFU 3 pole with neutral link, 415 volt, 800 amp-01 No (As I/C ) Make:L&T/C&S/Siemens/Havells,2. SFU 3 pole with neutral link, 415 volt, 200 amp,-05 Nos (As O/G) Make: L&T/ C&S/Havells/Siemens3. SFU 3 pole with neutral link, 415 volt, 160 amp,-02 Nos (As O/G ) Make: L&T/ C&S/Havells/Siemens4. SFU 3 pole with neutral link, 415 volt, 63 amp,-06 Nos (As O/G ) Make:L&T/C&S/Havells/Siemens5. Digital multifunctional Panel meter Amp/Volt/KWH /PF meter - 01 Set Make : Secure/C&S/L&T/Neptune Model and make:L&T MFM4410LCD METER CL 1 OR EQUIVALENT6.LED Panel indicator for phase detection 03 NosMake: L&T/C&S/SiemensMin current rating of main bus bar 3 X 2000 Amps ( for Phase) & 1 X 1000 Amps (For Neutral) All connection are as per IE rules and as directed by EIC. |
| 52 | S&F wiring for submain wiring along with earth wire through steel conduit 1100 volt grade heavy duty single core FR PVC insulated Copper conductor cable Size 4 X 10 Sq mm + 1 X 10 Sq mm including all connection Cable Make:Anchor/Havells/Finolex/RR |
| 53 | S&F wiring for submain wiring along with earth wire through steel conduit 1100 volt grade heavy duty single core FR PVC insulated Copper conductor cable Size 4 X 6 Sq mm + 1 X 6 Sq mm including all connection Cable Make:Anchor/Havells/Finolex/RR |
| 54 | S&F wiring for submain wiring along with earth wire through steel conduit 1100 volt grade heavy duty single core FR PVC insulated Copper conductor cable Size 2 X 4 Sq mm + 1 X 4 Sq mm including all connection Cable Make : Anchor/Havells/Finolex/RR |
| 55 | M&L Per Point wiring of light Per Point /fan Per Point & 5 amps socket bell Per Point , one Per Point controlled by one switch with 1.5 sq mm single core copper stranded conductor, PVC insulated & sheathed cable through stove enameled steel conduit surface on wallwith all fixing accessories. All connection of should be connected properly as per IE rule. cable make: Finolex/Anchor/Havells/RR |
| 56 | As item No 55 but on sameboard for 5 amp 3 pin socketcable make: Finolex/Anchor/Havells/Universal |
| 57 | As item no 55 but with 2.5 sq mm single core, copper stranded conductor for 3 pin 5/15 amp 3 pin switch socket plug Per Point wiring |
| 58 | As item no 55 but with 4 sq mm single core, copper stranded conductor for 3 pin industrial socketwiring |
| 59 | M&L Per Point wiring for telephone wiring . With socket through 1.5 sq mm single cu telephone cable |
| 60 | S&F 3 terminal surface backlightceiling rose of ISI mark size 65 X 55 Mm Make: Anchor/C&S/ROMA/Legrand |
| 61 | S&F piano type switch button flush type single pole 250 volts 6amp ISI markMake: Havells/Leader/Anchor/HPL |
| 62 | S&F single phase 250 volt switch socket combination 6/16 Amp 2 in one shutter type ISI mark, flush type including earth Per Point Make: Havells/Leader/Anchor/HPL |
| 63 | do as item no 62 but 6 amp 2 in 1 type Make: Havells/Leader/Anchor/HPL |
| 64 | S& F GI pipe 40 mm dia medium grade laid in ground or fitted on wall /pole with all fixing accessories |
| 65 | S& F GI pipe 80 mm dia medium grade laid in ground or fitted on wall /pole with all fixing accessories |
| 66 | M&L cast iron pressed steel terminal box rectangular in size 75X 75 mm for mounting switches,sockets, fan regulator etc. with 3.00 mm thick white hyluminated sheet over with fix in arrangement |
| 67 | M&L cast iron pressed steel terminal box rectangular in size 175X 100 mm for mounting switches,sockets, fan regulator etc. with 3.00 mm thick white hyluminated sheet over with fix in arrangement |
| 68 | M&L cast iron pressed steel terminal box rectangular in size 250 X 300mm for mounting switches,sockets, fan regulator etc. with 3.00 mm thick white hyluminated sheet over with fix in arrangement |
| 69 | S&F of sheet metal enclosure double door, triple pole & neutral, 12 way, 415 volt for sub DBsmake of DB : Havells/ L&T/ C&S/schneider |
| 70 | M&L MCCB 415 volt, 16 KA, 4 Pole, 125 amp Suitable to fix in item no 18 as I/CMake: Havells/C&S/L&T/schneider |
| 71 | S&F 415 volt , 10KA, \"B\" curve miniature circuit breaker (MCB) of TP 25 To 63 Amp in the DB complete with connection testing and commissioning Make: Havells/C&S/L&T/schneider |
| 72 | S&F 240 volt , 10KA, \"B\" curve miniature circuit breaker (MCB) of single pole and current caring capacity 6 to 32 amp in the DB complete with connection testing and commissioning Make: Havells/C&S/L&T/schneider |
| 73 | Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 63 AmpMake: Havells/C&S/L&T/schneider |
| 74 | M&L XLPE insulated, armored heavy duty electric cable with aluminum conductor, 1100 volts grade,3 & 1/2 core, cross-sectional area 50 Sq mmMake: Havells/Finolex/ Universal/Polycab |
| 75 | S/F, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single Double poleMCB of 20 amps, 240 volts A.C. MAKE: Havells/ Schneider / BCH/ C&S |
| 76 | S&F socket outlet 2 in 1 type flush type 3 pin 5 amp with earth terminal Make: Anchor/ Havells/ HPL/ Roma |
| 77 | Cutting grooves in brick wall 75 mm in width and 65 mm in deep and snapping horizontal/Vertical as required formounting concealed switch boards , making good disturb surfaces of wall with cement mortar and plaster 1:3 as existing wall condition and as directed by EIC |
| 78 | S&F of LED high bay light fittings 80 watts, input voltage - 140-270 volts operating voltage , 50 Hz, Color Temp 5500-6500 K, LED efficiency≥ 100 lumen/watts, beam angle 120 degree, PF ≥ 95, THD - less than 10%installed concealed enclosure/Housing to protect dust and water/paintMake: Philips/Osram/Syska/ HPL |
| 79 | S&F of LED high bay light fittings 120 watts, input voltage - 140-270 volts operating voltage , 50 Hz, Color Temp 5500-6500 K, LED efficiency≥ 100 lumen/watts, beam angle 120 degree, PF ≥ 95, THD - less than 10%installed concealed enclosure/Housing to protect dust and water/paintMake: Philips/Osram/Syska/ HPL |
| 80 | Cutting and opening cement concrete wall( any description track for inserting /laying pipe or cable as directed by EIC. |
| 81 | S&F cable route indicator dully marked With \" HT cable\" made of CI plate 6mm thick fixed with MS angle IRON 30 X 30 X 4 mm of length 400 mm long embedded in PCC 1:2:4 type B of Size 150 x150 x 150 mm including necessary workExcavation getting out soft/lose soil Returning filling and removal all as directed |
| 82 | M&L for boring of Holes under the road, for laying Cable support pipe of 80 mm dia , depth of pipe must be not less than 1 Mtrs from ground level |
| 83 | M & L, cement concrete , Ty B-2, 1 :2:4, 40 mm graded aggregate in foundation and mass concrete in wall / floor or track ,any thickness,size as required including plasters as directed by EIC. |
| 84 | S&F air circulator wall hanging type single phase, 600 MM sweep, 1430 RPM, power input max 200 watts, noise level 68 dbindustrial type,model no RRAC 600 P/W 1 make RR or equivalent make : RR/Standard/Crompton/Bajaj |
| 85 | M&L XLPE insulated, armored heavy duty electric cable with aluminum conductor, 1100 volts grade,3 & 1/2 core, cross-sectional area 150 Sq mmMake: Havells/ Finolex/ Universal/ Polycab |
| 86 | M&L XLPE insulated, armored heavy duty electric cable with aluminum conductor, 1100 volts grade,4 core, cross-sectional area 25 Sq mmMake: Havells/ Finolex/ Universal/ Polycab |
| 87 | Excavation of trench in hard densesoil, not exceeding 1.5 m wide and not exceeding 1.5 m in depthfor laying underground cable and getting out excavation earth as ordered. |
| 88 | S&F infra red sensor based NATURE SWITCH three phase 8 KW consisting of power contractor, AC confirming to IEC - 60947-4-1/IS 13947-4-1 for load switching and terminal blocks. The enclosure is made of UV stabilizes , FR grade special molding compound to provide a rust proof termite proof, outdoor mountable electrically insulating body capable of enduring solar radiation in the out door & suitable to mounting. The enclosure is provided with mounting brackets , cable glands openable door with lock and key. Selectable options for duration based switching OFF as well as override facility for maintenance should be available complete all as specified and directed. Make: Healer Enterprises Model SWADEEP -02EC-8KW 3P crono or equivalent |
| 89 | M&L XLPE insulated, armored heavy duty electric cable with aluminum conductor, 1100 volts grade,4 core, cross-sectional area 16 Sq mmMake: Havells/Finolex/ Universal/Polycab |
| 90 | Supply erecting and fixing true vertical position Galvanized iron Octagonal type pole, 09 Mtrs. long factory made with one bracket of 1.5 mtr. Long and inbuilt loop in/ loop out boxes with one MCB of 6 Amps SP complete with base plate, pole cap / final taper plug, bolts, nuts and washers including provision of necessary earth work, i.e. excavation, return filling and PCC as per manufacturer recommended complete all as specified and directed. Make: Surya Roshni/Bajaj/Wipro/Philips |
| 91 | Supply and fixing of LED street light fitting 70 watt 230 Volt AC out door type with high pressure die cast aluminumhosing and heat resistant complete with driver lamp bracketwith impact and corrosionresistant including thermal management in multiple optics complete with IP 65/66 protection complete Make: Surya Roshni/Bajaj/Wipro/Philips |
| 92 | Supply and fixing of LED flood light 120 Watts 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection with impact and corrosion resistant complete with driver and lamp |
AI Tender Summary
Tender Timeline
Oct 05, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedOct 26, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 28, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender