|
| 1 | M & L for dismantling ,transporting to civil workshop centrifugal pump coupled with electric motor, Split opening of following capacitiespumpset including cleaning with kerosene/petrol for removing dirt supply and replacement of small parts like impeller nut ,lock,washer, packing,gasket greasing oiling and reassembling, connecting in position testing, commissioning the pumpset complete all as directed.(Major Part will be Measured and paidin relevant Items of this schedule) |
| 2 | 75 HP Motor |
| 3 | 60 HP Motor |
| 4 | 40 HP Motor |
| 5 | 30 HP Motor |
| 6 | 25 HP Motor |
| 7 | 20 HP Motor |
| 8 | 15 HP Motor |
| 9 | 7.5 HP Motor |
| 10 | M & L for taking down carefully electric motor 3-phase 415v,50Hz,AC from foundation/ coupling, transporting to civil workshop, opening the motor,Checking the insulation value of the windings, insulating the winding with same class of insulation varnish,Oiling Greassing of bearing and busing , painting with one coat of synthetic enamel paint as per color code and back to site for re-installing the motor and connecting to the pump, testing the motor for satisfactory performance all as directed by Engineer -in-Charge and all as specified for the following capacity.(Major Part will be Measured and paidin relevant Items of this schedule) |
| 11 | 75 HP Motor |
| 12 | 60 HP Motor |
| 13 | 40 HP Motor |
| 14 | 30 HP Motor |
| 15 | 25 HP Motor |
| 16 | 20 HP Motor |
| 17 | 15 HP Motor |
| 18 | 7.5 HP Motor |
| 19 | Supply and fixin replacement of the following bearings required as directed |
| 20 | 75 HP Motor |
| 21 | 60 HP Motor |
| 22 | 40 HP Motor |
| 23 | 30 HP Motor |
| 24 | 25 HP Motor |
| 25 | 20 HP Motor |
| 26 | 15 HP Motor |
| 27 | 7.5 HP Motor |
| 28 | Supply and fix in rep terminal block made out from brass complete with backelite plate for the following capacities. |
| 29 | 75 HP Motor |
| 30 | 60 HP Motor |
| 31 | 40 HP Motor |
| 32 | 30 HP Motor |
| 33 | 25 HP Motor |
| 34 | 20 HP Motor |
| 35 | 15 HP Motor |
| 36 | 7.5 HP Motor |
| 37 | Supply and fix replace bush for pump suitable for the following capacity of pumps |
| 38 | 75 HP Motor |
| 39 | 60 HP Motor |
| 40 | 40 HP Motor |
| 41 | 30 HP Motor |
| 42 | 25 HP Motor |
| 43 | 20 HP Motor |
| 44 | 15 HP Motor |
| 45 | 7.5 HP Motor |
| 46 | Dismantling and taking out pumpmotor ,transporting the same work shop opening the motor, removing burnt winding and cleaning winding slots and rewinding of motor using suitable existing gauge/ sizewith supper enamelled copper wire, replacinginsulation paper of class Fand fire proof sleeves, varnishing, baking complete, oiling, greasing, replacing oldrear/ frontbearings with new and reassembling complete motor includingtestingat site all as directed by Engr- in -charge |
| 47 | 75 HP Motor |
| 48 | 60 HP Motor |
| 49 | 40 HP Motor |
| 50 | 30 HP Motor |
| 51 | 25 HP Motor |
| 52 | 20 HP Motor |
| 53 | 15 HP Motor |
| 54 | 7.5 HP Motor |
| 55 | Disconnecting electrictrical and mechanicaly and taking out submersible motor pumpset of followingcapacity complete from installed position/ sump , disconnecting of motor, transporting the motor to local workshop ,Split opening ofthe motor, removing burnt winding and cleaning the slots and rewinding of motor usingnew super enameled copper windingwire of suitable gauge / size, replacing paper insulation of suitable exisiting class and fire proof sleeves, varnishingetc. complete with oiling, greasing, replacing unsvthrust bearing and bushes after repairing , reassembling complete pump andmotor after repairinglowering in existing position and testingall as specified anddirected . |
| 56 | 25 HP Motor |
| 57 | 10 HP Motor |
| 58 | 5 HP Motor |
| 59 | 3 HP Motor |
| 60 | Taking down old existing unserviceable cast iron / ductile iron pipe M & L DI pipes with socket end or both ends flanged centrifugally cast, class -\"B\", conforming to IS 8329/ 2000, in any length suitable for flangejoint complete all as specified & directed of following sizes:- |
| 61 | DIpipe 300mm dia |
| 62 | DIpipe 200mm dia |
| 63 | DI pipe 150 mm dia |
| 64 | DI pipe 100 mm dia |
| 65 | DIpipe 80 mm dia |
| 66 | Taking down old existing unserviceable cast iron / ductile iron pipe M & L CI pipes with both ends flanged centrifugally cast, class -\"B\", conforming to IS 8329/ 2000, in any length suitable for flangejoint complete all as specified & directed of following sizes:- |
| 67 | CIpipe 300mm dia |
| 68 | CIpipe 200mm dia |
| 69 | CI pipe 150 mm dia |
| 70 | CI pipe 100 mm dia |
| 71 | CIpipe 80 mm dia |
| 72 | Taking down old existing unserviceable ERW pipe M& L ERW pipes with both ends flanged centrifugally cast, class -\"C\",in any length suitable for flangejoint complete all as specified & directed of following sizes:-( Note-i) Turning bening, welding, westages are included in quotated rate.ii) Working permission subject to no hamper of daily water supply to the user unit ) |
| 73 | ERWpipe 300mm dia |
| 74 | ERWpipe 200mm dia |
| 75 | ERW pipe 150 mm dia |
| 76 | ERW pipe 100 mm dia |
| 77 | Taking downfiber board gasket joint M&L for joint with rubber or fibre board gasket complete with suitable size nuts, bolts and washers etc as directed for flanged pipes & fittings for followings sizes:- |
| 78 | 300 mm dia |
| 79 | 200 mm dia |
| 80 | 150 mm dia |
| 81 | 100 mm dia |
| 82 | 80 mm dia |
| 83 | Taking down unserviceable CI/DI/ fitting of any type,M&L cast iron fitting (any type radius and angle) taper any type (Straight) bend increasing decreasing or double socket etc Tee pieces, single branch ‘Y’ junction double branch, coller, capacity and plugs for up to 150 mm bore to 400 mm CI pipe conforming to IS-1538- 1976 complete and all as specified and directed. |
| 84 | Taking down unserviceable foot valve and supply and fixing CI foot valve of following sizes including jointing materials all as specified and directed |
| 85 | 150 MM Dia |
| 86 | 100 MM Dia |
| 87 | 80 MM Dia |
| 88 | Taking down unserviciable and S & F in repairtyre coupling of following sizes with existing alignement all as specifiedand directed |
| 89 | A 18 Size |
| 90 | A 42 Size |
| 91 | A 60 Size |
| 92 | Servicing of Starter Panel of any capacity and any type by using anti rust spray to removal of carbaon from moving contact carbon upto the entire statisfaction of Engr-in-Charge |
| 93 | Taking down unserviciable and Supply and fixin repair3 pole power contactor of following sizes suitable for existing contactor complete all as specified and directed :- |
| 94 | MNX 95 |
| 95 | MNX 70 |
| 96 | MNX 45 |
| 97 | MNX 40 |
| 98 | MNX 25 |
| 99 | MNX 12/22 |
| 100 | Taking down unserviciable andSupply and fixin repair SD timer 100 range 3-30 Sec coil voltage 240/360/415 Volt AC . (Make - L&TCAT part No. ST803280000 or equivalent rating on other make ) |
| 101 | Taking down unserviciable andSupply and fixin repair thermal overhead relay with start and off/reset of Amps of following ranges suitable for existing all as specified and directed |
| 102 | Relay Range 66-110 Amps |
| 103 | Relay Range 30-50 Amps |
| 104 | Relay Range 24-40 Amps |
| 105 | Relay Range 20-33Amps |
| 106 | Relay Range 14-23 Amps |
| 107 | Relay Range 9-15 Amps |
| 108 | Taking down unserviciable andSupply and Fixing in replacement Water pressure gauge of capacity 5 Kg/mm2 gauge 8 \" or 6\" (size of dial) all as directed (Make-ISI Make) |
| 109 | Taking down unserviciable and Suupply and fixin repair NRV of size of following size, Class PN 1.6, hydrodynamically guided, closing non return valve with gray Cast iron body, synthetic rubber coated reinforced ball, flanged type including 6mm thick rubber gasket, MS nuts, bolts and washers and dismantling the unserviceable NRVall as directed. |
| 110 | 300 MM Dia |
| 111 | 200 MM Dia |
| 112 | 150 MM Dia |
| 113 | 80 MM Dia |
| 114 | Design, fabrication, supply and install, testing and commissioning indoor Panel, including necessary excavation/refilling for trace out incoming and out going cable connection, thimbles of size as required, cubical outdoor type, made out of 2.00 mm thick CRCA sheet, size not less than 1350 mm (height) X 1800 mm (length) X 450 mm (Depth), weather and vermin proof with IP-54 protection, both side openable double door front side & having, locking arrangments on both sides, mounted over angle iron frame at the bottom of height not less than 45 cm above ground level and not less than 30 cm in ground/floor mounted duly grouted in PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) facotry made CPRI approved duly powder coated and write name of motor\"s connected at outgoing |
| 115 | Incoming:- 1) MCC 400 Amps, 04 Pole 50 KA, Ics=|cu=100%DN Series Make L & T - 01 Nos Outgoing:-MCCB, MCB, Relays, Contactors, timers etc. as follows:- i) 125 Amps, 03 Pole MCCB 25 KA, Make L & T - 03 Nos ii) 06 Amps, 01 Pole MCB 10 KA, C curve Make L & T (for control) - 01 Nos iii) Timer for Star Delta connection - 03 Nos iv) Ralay of capacity 36 to 60 Amps for motor MN 5 for MNX Contactor - 03 Nos v) Power contactor 03 Pole 240 Volt 70 Amps capacity - 09 Nos vi) Add on Block containing 02 NO + 02 NC suitable for MNX Contactor - 09 Nos vii) CBT connector of 110 Amps - 24 Nos viii) Digital Smart Panel Meter for showing Voltage and Amp meter suitable for 400/5 CT - 01 Nos ix) CT of Capacity 400/5 - 01 Set of Three x) Digital Amps meter suitable for 125/5 CT of size 96 mm X 96 mm xi) CT of Capacity 125/5 xii) 16 Sq mm Copper Flexible wire for Power wiring of 60 HP Motor (02 Runs from Incomer to 125 Amps MCCB) - 75 RM (Approx) xiii) 4 0q mm wire for Power wiring of 2 to 5 HP Motor - 100 RM (Approx) xiv) 1.5 Sq mm Copper Flexible wire for control, other panel wiring and CT wiring - 150 RM (Approx) xv) Hardware like lugs, nut bolts, insulator for bus bar, cable tie, CBT Rail, cable tray, - Lumpsump xvi) Motor on / off indicator - 06 Nos (Set of 02 X 03 Nos) xvii) R, Y,B indicator for main incommer - 03 Nos (Set of 03 X 01 Nos) xviii) ON and Off push button along with NO and NC element - 03 Nos (Set of 02 X 03 )xix) Voltmeter 0-500V digital type with inbuiltphase selection -01 No |
| 116 | M & L for Digital Backlight glow sign board star flex made out of 0.75x0.75 mm MS frame box type with back side having galvanised tin sheet of thickness not less than 22 gauges and side cover with powder coated tin sheet including 20 Watt : 02 Nos LED Fitting. The frame box to be fitted welded on MS round pipe as required length 3 to 4 meter each of thickness not less than 6 gauge. The size of the Board should be 8 feet x 3 feetNotes:(a) The rate of PCC work for coping and foundation of these board are included in the quoted rate.(b) The MS frame and MS pipeare to be painted black incolour after one coat of red oxide primer.(c) The Quoted rates are inclusive of dismantling the old glow sign board |
| 117 | Supply and fix 15 ft x 3 fl size, 3 MM ACP sheet Recto reflective Sign board of 1.00 size on frame of MS tubing 40mmx40mm, with 4 nos support of 40mm tubing for board including Side pillar of height 8 ft mounted on RCC coloummade out of 40x40 mm Angle of 6mm thick of 4 nos angle on each columb with support at interval of 2 ft all as specified and directed by Engr-in- charge. Nole:- (1) The content on the board will be finalised with concerned JE/Engr-in-charge. (il) The rates are inclusive of dismantling the old glow sign board from any Height. |
| 118 | Supply and fix 6 Ft x 4 Ft sign board made out of 3MM ACP Sheet LG mark vineyal pasting on 0.75 x 0.75 inch MS frame with vertical side pole of ms angle of size 40x40 mm, 6 mm thickness with necessary excation, PCC and copping all included/all as per specified and directed by Engr-in-charge. Note : (i Content of board to be frinalize with concern of JE/ Engr-in-charge: (i) The rates are inclusive of dismantling the old glow sign board from any Height. |
| 119 | Taking down unserviciable and Supply and fix in repair sluice valve cast iron body double flanged type PN1.6, with SS Spindle, ISI Mark offollowing capacities |
| 120 | 400mm dia |
| 121 | 300 mm dia |
| 122 | 200 mm dia |
| 123 | 150 mm dia |
| 124 | 100 mm dia |
| 125 | 80 mm dia |
| 126 | Taking down unserviciable and Supply and fix in repair air release valve cast iron body flanged type double acting type, ISI Mark of 200 mm Size |
| 127 | Taking down unserviciable and Supply & fix in repair SS wire rope with PVC Coating of size 10mm dia complete all as specified |
| 128 | Taking down unserviciable and Supply and fix in repair rubber gland packing suitable for sluice valve of following sizes |
| 129 | 400 mm dia |
| 130 | 300 mm dia. |
| 131 | 200/150mm dia. |
| 132 | 100/80 mm dia. |
| 133 | Repair of NRV of size 200 mm flanged type by opening and cleaning inner plate spindle replacement of6 mm thick rubber gasket, MS nuts, bolts and washers after repairing refixing the same in existing position all as specified and as directed. |
| 134 | M&L painting of ,motor complete setincluding base plate,of capacityup to40 HP motors with two coat of synthetic enamel paint over a coat of red oxide primer after preparing surfacesincluding wiring of MES / SM No all as directed by Engineer-in-Charge. |
| 135 | M&L painting of pump,motor complete set including base plate, of capacity 60 HPto 75 HP motor with two coat of synthetic enamel paint after preparing surfacesall as directed by Engineer-in-Charge. |
| 136 | M&L for cleaning with surface dressing or trimming of natural groundbushes/small trees/shurbes includingremoving andcarrying away the rubbish from siteto a distance not exceeding 50m awayfromall as specified and directedby Engineer-in- charge. |
| 137 | Taking down unserviciable and Supplyand fix in replacementonly RYB indicator lamp LED type (Set of three lamp) for incoming and outgoing supply as per existing sizes all as directed by Engr-in-Charge. |
| 138 | Taking down unserviciable and Supply and Fix in replacement of CTs of 200/5 current rating AC, 415 V, three phase including connecting to supply as per existing all as directed by Engr-in-Charge. |
| 139 | Taking down unserviciable and Supplyand fix in replacement Ammeter three phase digital type 50 HZ, AC as per existing sizes/ range all as directed by Engr-in-Charge. |
| 140 | Taking down unserviciable and Supply and fix iin replacement voltmeter three phase digital type 0-500 V, 50 HZ, AC as per existing sizes all as directed by Engr-in-Charge. |
| 141 | Taking down unserviciable and S& F single phase preventor relay SPPR type Sz5(6 wire) 415 V 50 Hz Make Siemens or equevelent approvd make |
| 142 | Taking down unserviciable andM& L for fabrication/structuralwork with mild steelsheet/ angleironin any shape or size as indicated or directed andincluding belding/ bracing, painting with one coat of red oxide primer and two coat of blackpaint (one coatbefore fixings and one coat of blackpaint after fixing ) complete all as specified and directed. |
| 143 | M&L for PCC 1:3:6 ,Type C1, using 20mm graded aggragate for foundations, filling and mass concrete |
| 144 | Material and labour in repair of mild steel plates (plain or chequered) of5mm thick or over in thickness in available sizes Fe-290 (Gde E-165) complete all as specified and directed. |
| 145 | Supply only PPM testing kit for portable/ drinking watermeasuring range 0.2 PPM to 5 PPM all as specified and directed (Make- Any approved Coy From Govt Lab) |
| 146 | Taking down unserviciable and Supply and laying in replacement PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade complete layin in trenches /wall/ floor / pipe etc of cross-sectional area of following site |
| 147 | 185 Sqmm 3.5 Core |
| 148 | 95 Sqmm 3.5 Core |
| 149 | 50 Sqmm 3.5 Core |
| 150 | 35 Sqmm 3.5 Core |
| 151 | 10 Sqmm 4 Core |
| 152 | Taking down unserviciable and M&L for replacement of submersible cable round/flat of 3 core 6 Sqmm with multistanded copper coundecter all as directed. |
| 153 | Taking down unserviciable and S & F Multicore PVC insulated, PVC Unsheathed industrial cable with flexible bright annealed copper conductor for voltage grade up to 1100 voltsConformimg to IS 694 for following size |
| 154 | 10 Sqmm 3 Core |
| 155 | 16 Sqmm 3 Core |
| 156 | 4 Sqmm 3 Core |
| 157 | Labour for attaining the complaints any type of electric motor / pumps including complaints of electric fault of water supply installations in the AOR of GE (MH & RH) around the clock on call basis when required and directed including attending the pipe line leakge inside the water supply installation, detect the pump motor cable fault testing, commissioning and making working condition of water supply installations complete all as specified and directed by Engr-in-Charge.(Note: (i) Major Spares and material measured and paid separately under relavant item (ii) The quotated rate shall be included the special tool charges requried for attending the fault in quotated rate(iii) Minor spare part required for attending the fault such grease, nut bolts, washers, studs are included in quotated rate.) |
| 158 | Taking down unserviciable and Taking down of existing unsearviceable water meter 300 mm dia by discunnecting of all nuts boltsand repair the same by replacing all unserviceable parts and calibration / testingthe same from MIDC water works authority complate all as specified and as directed |
| 159 | S & F MCCBTPNof following sizes suitable for fixing on Panel/ Starter of pump and motorwith extended terminals complete all as specified. Make : Schindier / Legrand / L&T / ABB |
| 160 | MCCB 400 Amps, 4 pole, 50 KA |
| 161 | MCCB 315 Amps, 4 pole, 50 KA |
| 162 | MCCB 160 Amps, 4 pole, 36KA |
| 163 | MCCB 100 Amps, 3 pole, 36 KA |
| 164 | MCCB 63 Amps, 3 pole, 36 KA |
| 165 | M&L for cement concrete interlocking tiles 60 mm thick in floor/pavement laid over and including 30 mm thick stone dust/sand cushioning laid dry to profile complete all as specified and directed by Engineer-in-Charge |
| 166 | S& F following size soft starters for following motorscomplete all as specified and directed by Engineer-in-Charge |
| 167 | 60 HP |
| 168 | 40/30 HP |
| 169 | 25/20 HP |
| 170 | 15/10HP |