| 1 | M&L For Preparationold decorated surfaces of ceiling , spoiled bysmoke soot, moulds, moss and efflorescent salts and tradingoil and greasy spots by scraping and washing with water and applying two coat of white wash on ceiling complete all asspecifiedand directed by Engineer-in-Charge. (Note:- work will be strictly executed by mechinised means/ tools as required for smart periodical services) |
| 2 | M&L for(1) complete removal of existing treatment by scrapping with Vacuum based mechanical wall sander ( having mechanical vacuum mechanism) having RPM not less than 1500, with sanding pad and (2)applying 1mm thick water proof cement based putty over the plastered/old painted wall after scrapping to prepare the surface even and smooth and sanding of the putty surface with Mechanical wall sander (putty should be mixed by using putty mixer and apply first coat the prepared mixer with the help of fully Automatic airless spray machine having flow speed of 6ltrs per minute with a maximum pressure of 3300 PSI). (3)After 6-8 hrs time apply one coat of acrylic water based interior grade primer (0.8L/10sqm with water 1:1 ratio) by using fully automatic airless spray machine with flow speed of 1 tr per minute having maximum 3300PSI pressure.(4) After 6-8 hrs time apply two coats of acrylic distemper using airless spray technology with max 3300 PSI pressure and capable of operating single spray gun with a max material hose length of 30mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas all as specified.Note:- Refer the Make of putty, primer, acrylic distemper in the List of Makes mentioned in PS Clause. The building No.is also mentioned in the PS clause. |
| 3 | M&L forpreparation of old decorated wooden surfaces of any descriptionnot other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint. complete all as specified and directed. |
| 4 | M&L for preparation of old decorated steel surfaces ofany description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 5 | M&L for preparation of old decorated surfaces of wall and cornices by scrapping using vacuum based mechanical wall sander and washing with water and applying one coat of acrylic water based exterior grade primer of professional pack of Asian paints or [email protected] L/10sqm with water in 1:1 ratio by using fully automatic airless spray machine of paint application with flow speed of 1Litre per minute having max pressure of 3300 PSI. Applying two coats of 100% antifungal acrylic emulsion weather coat exterior paint up to 6th storey of building including necessary scaffolding as per manufacturer instructions with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed all as specified and directed by Engineer-in-Charge. Note:- Refer the Make of professional pack of exteriorprimer, acrylic emulsion weather coat exterior paint in the List of Makes mentioned in PS Clause. The building No.is also mentioned in the PS clause. |
| 6 | M & L for cutting out cracks (not exc 5mm) to V-section in existing wall/chajjas and cleaning out and filling up with Dr fixit crack seal including necessary scaffoldingscomplete all as specified and as directed. |
| 7 | Taking down cement mortar or lime plaster of any description from stone or brick wall etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish materials out side MD andincluding necessary scaffoldings complete all as specified and directed. |
| 8 | M&L for plastering in CM1:6, 10 mm thick on walls finished even and smooth w/o using extra cement complete all as specified and directed. |
| 9 | M&L for plastering in CM 1:3 , 5mm thick on ceiling finished even and smooth without using extra cement complete all as specified and directed. |
| 10 | M & L for 20 mm (15+5mm) thick ready mix plaster using WPC @ 2% by weight of cement on brick work or concrete surfaces; surfaces finished even and smooth including necessary scaffolding complete all as specified Note : Water proofing compound shall be measured & paid seperately. |
| 11 | M/L for preparation of new plastered surfaces of walls and applying two coats ofacrylic distemper over a coat of alkali resistant primerusing roller etc complete all as specified and directed. |
| 12 | M&L for preparation new plastered wall surface to receive finshes upto 5 storey buildings by twocoat water based premium acrylic smooth exterior emulsion 100% weather proof, anti fungal of approved colourwithairless spray machine of paint application including one coat of primer complete all as specified and directed. |
| 13 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of primercomplete all as specified and directed |
| 14 | supply Integral water proofing Liquid. |
| 15 | M/Lforfrench polishing on surfaces of any description width or girth and including cleaning and preparing the surfaces including a coat of wooden filler on old wooden surfaces one or more coat etc complete all as specified and directed. |
| 16 | Writing letter or figures (block, Roman, Italic, orIndian ) n.ex 20 cm hight complete all asspecified and directed. |
| 17 | M&L stops, commas, short lines, dashes, hyphens, brackets etc complete all as specified and directed. |
| 18 | M&L for Removal of plantgrowth by injection with chemical glyphospate solution ( 4 % conceneration ) @ 20ml or till refuse by cutting or injection in stem of plants or roots at 30mm. The area shall then be sprayed with solution 25ml glyphosphate ( 4% concent) dulited with 1 ltr of water. All roots / plants shall be removed completely and making good the distrubed surface and painted with cement base or acrylic paint complete all as specified and directed. |
| 19 | Dismantling/Demolition of existing roof terracing of cement/brick concrete(un-reinforced) and existing water proofing treatment of any thickness in any position on top of roof of building, cleaning surface of roof with brush/mechanical brush and with water throughly to romove all dust/dirt and loose particles to expose bare concrete roof slab and romoval of rubbish/demolished material out side MD land complete all as specified and directed.Note: Demolition should be done by chiselling. |
| 20 | M&L for PCC (1:2:4) type B-0, using 12.5mm graded stone aggregate as in levelling course over RCC roof surface to achieve required slope including making rounded or chamfered on edges mixed with WPC @2% by weight of cement, complete all as specified and directed. Note : WPC shall be measured and paid separately as supply only. |
| 21 | \"Supply and Application of 4 Layer SHR Waterproofing Coating System as per manufacturer application procedure on for leaking concrete wall/ floor surface by thorough surface preparation with high pressure water jet min. 125 bars, opening the cracks, followed by one absorption coat of nano-tech enhanced elastomeric waterproofing (NEEWP) emulsion having UV resistance and min 50% solids, filling and sealing the cracks, then over coating with 2 Coats of NEEWP + Cement mixture as waterproofing coat having +450% Elongation followed by curing and then top-coated with 1 protective coat of SHR Coating - pure acrylic based, UV resistant, non-yellowing, bio-organism resistant (anti-fungal, anti-bacterial) conforming to BIS STD IS 17218:2019 with Pull off Adhesion 2.8 Mpa, passes 2000 hrs accelerated durability test, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 SQM/Ltr/2 Coats, DFT 100 - 120 microns using brush, roller, airless spray gun as applicable. The product should be certified by NABL Approved Lab and application is to be done by company approved applicator only\"Note:- Make:- BASF/ Thermacool/ Dr.Fixit/ Tikidan with their specification and 5 year guarantee period. |
| 22 | Chipping, removing carefully loose/damaged concrete including plasteringfrom surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force |
| 23 | M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchemas approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete& new concrete/ new mortar by brush application complete all as specified and directed. |
| 24 | M&L for carry out application of Bi -polar migratory corrosion inhibitor (make, M/S Krishna conchem (EPCO KP -100) / BASF ( master protect 8000 CI) on RCC surfaces complete all as specified and directed.( Note: Mode of measurment superficial area of concrete will be measured.) |
| 25 | M&L for Anticorrosive Treatment to Reinforcementusing IPNET-RB of M/s Krishna Conchem orEpoxy Zinc Primer of M/s. Dr. Fixitby application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat.The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed. Note :- Mode of measurement: superficial area of concrete will be measured. |
| 26 | M&L for building up the profile of structural members using polymer modified mortarwhile the bonding agent is still tacking upto 20mm thickness including levelling, profiling etc complete all as specified and directed. |
| 27 | M&L for building up the profile of structural members using polymer modifiedexceeding 20mm thick and not exceeding 40mm thick in two layers each of equal thickness including levelling, profilling etc complete all as specified and directed. |
| 28 | M&L for Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed. |
| 29 | Demolition of concrete in ground floors (un re-inforced) and paving n.exc. 15 cm thickness (below or above ground level) and removal of rubbish/ demolished materials out of MD landcomplete all as specified and directed. |
| 30 | M&L for Cement concrete RMC M30 (20mm graded aggregate) for flooring complete all as specified. Note:- OPC 43/53 grade cement only shall be used for flooring by the prior approval of design mix. Before placing M30 grade of concrete including all shuttering and supporting to maintain proper box as bay wise with MS sections as directed by Eng-in-Charge. Note:- The design mix should be submitted before starting the work and also the approved RMC plant mentioned in the PS Clause. |
| 31 | M&L for RMC M20 design mix using 20mm graded aggregate for flooring of stages complete all as specified. The cement used should be of OPC 43/53 grade and work should be commenced only after prior approval of the design mix with RMC plant mentioned in the PS clause .Before placing M20 grade of concrete including all shuttering and supporting to maintain proper box as bay wise with MS sections as directed by Eng-in-Charge . |
| 32 | M&L for using the nonmetallicfloor hardener as the stages described below with applicator :-Level the freshly poured concrete with suitable mechanical equipment like screed vibrator and smoothen the surface. Beforecommencement of the application, the base concrete should be checked by pressing thumb hard on the surface, it should leave an impression of 3mm to 5mm depth.The application is made in two stages:-(1) The first application is made using 50% to 70% of required material quantity of Myk floarmfloorhard /Fosroc Nitoflor Hard top STD which is dry shake nonmetallic floor hardener. It is evenly broad casted by using hardener spreading machine on the concrete surface and when the material or surface becomes dark by absorbing the moisture from the concrete the first application can be floated. Power trowel with disc can be used. Care should be taken that it is not over floated.2) The second application is made by immediately after by evenly broadcasting the balance material and when the surface becomes dark by adsorbing the concrete surface moisture has darkened with the absorption of water it shall be floated in the same way as before.3) Final finishing shall be carried out after the surface has sufficiently stiffened to close any pores and to remove any disc marks.4)While applying the hardener at the edges of the concrete floor or at the end of bays extra precaution should be taken by way of sprinkling more material and finishing it smoothly with the trowel. This is an additional precaution particularly to bay edges where the reaction due to heavy traffic is more. Rate of consumption of floor hardener 7kg/sqmNote:- The application should be done by authorized applicator only . |
| 33 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where complete all as specified and directed. |
| 34 | M&L for forming contraction(dummy) joints 65mm deepx10mm wide filled with sealing compound Grade A complete all as specified and directed. |
| 35 | M&L for Forming Construction joint 30mm deep x 10mm wide filled with sealing compound with sealing compound grade A complete all as specified and directed. |
| 36 | M&L for rendering 10 mm thick on fair faces of brick work in CM 1:6 and 5mm thick in CM 1:4 including water proofing compound,finishing even and smooth without using extra cement. (WPC shall be measured and paid separately) |
| 37 | Supply only integral water proofing compound. |
| 38 | Taking down chowkets or frames not exc. 1.5 Sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 39 | S&F aluminium section in doors/windows/ventilators ,kitchen cupboards, built n almirah doors any type, powder coated in approvedcolour (Thickness of powder coating not less than 50 micron), aluminium section (medium weight of series \"B\") orsection as directed by Engineer-in-Charge, cut to size, jointed together with cadmium plated steel screws including rubber beading or gasket for aluminium sections for fixing glass/XPM jali or for fixing bakelite sheet and all necessary fittings complete, screws, plugs for fixing screws, etc all as specified and directedNotes: (i) Weight of aluminium sections shall only be measured. (ii) The supply only rate of glass pane will be measured separately. |
| 40 | Supply only 4.80 to 5 mm thickglass selected quality ineach pane for aluminimum door shutters, aluminium partetion wall and slidingwindows/ventilatorshutters etcn exc 0.50 Sqm each pane andincluding rubber beading or gasket for aluminium sectioncomplete all as specified and directed. |
| 41 | M&Lfor two coats of antifungal paint (Apex ultima of Asian Paints or equivalent in approved makes) over a coat of exterior primer (Professional pack of Asian Paint) on newly prepared plastered external surfaces and including scaffoldings and cradle including hoisting and lowering as required with bracing, support complete all as specified and directed. |
| 42 | M&L forpreparation ofnew plasteredsurfacesand applying three coats of white washon ceiling etc complete all as specified and directed. |
| 43 | Note for Item of smart periodicals:-(a.) The work pertaining to periodical services & Water Proofing shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Cement base paint, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer.(b.)The contractor shall upload along with the documents under cover-I, ‘Memorandum of Understanding’ (MOU) with only one manufacturer mentioned in the contract, failing which the bid shall be liable to be rejected.(c) The quoted rate shall deemed to be included the surface treatment for wall upto 16 storey buildings. |
| 44 | Deduct Credit for Demolished/ Dismantled material Rs. (-) 1800.00 (Minus) as listed in Schedule of CreditNote1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the \"Contract Sum\"Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and safety measures required during execution of work are including in this items. |