Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #45552601

Tender For Special Repair To Roof In No-5 Rect Coy To Prevent Leakage And Seepage In Rect Accn At 14 Gtc Subathu Under Ge Kasauli

Issued by Statutory Bodies & Commissions/Committees · subathu, Himachal Pradesh
Tender Value
48.57 Lakhs
Estimated cost
Bid Submission
12 Nov 2024
0 days left
EMD
97140
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
subathu → Himachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Special Repair To Roof In No-5 Rect Coy To Prevent Leakage And Seepage In Rect Accn At 14 Gtc Subathu Under Ge Kasauli

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 30-Oct-2024 CERTAIN AMENDMENTS TO CRITICAL DATES Date 12-Nov-2024

BOQ

Name of Work: SPECIAL REPAIR TO ROOF IN NO-5 RECT COY TO PREVENT LEAKAGE AND SEEPAGE IN RECT ACCN AT 14 GTC SUBATHU UNDER GE KASAULI.
Sl. No. Item Description
1Schedule \"A\" Section - I
2Dismantling of plain or corrugated steel sheet of any thickness incl Nainital or similar pattern coverings, complete all as specified and as directed.
3Supply and fixing ofPre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick, having Zinc coating 150 gm per sqm(Az-150)of any colour having tensile strength of 550 Mpaas in roof covering/cladding to wall, fixed with self tapping screws of length not less than 50mmcomplete all as specified and as directed.
4Supply and fixing ofPre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, having Zinc coating 150 gm per sqm(Az-150)as in roof covering/cladding to wall, fixed with self tapping screws, cut to designed shape (Jhhallar)and fixed with self thread making steel screws of length not less than 50mmcomplete all as specified and as directed.
5Dismantlingtimber scantlings 40 sq. cm and over in section in any position ( unframed work ) complete all as specified and as directed.
6Supply and fixing of rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410-W (Grade E-250) quality ‘A’ complete all as specified and as directed by the Engineer-in-Charge.
7Demolition ofcement concrete in ground floor and pavings not exceeding 15cm thickness (below or above ground level) and removal the rubbish/ demolished material outside defence land, complete all as specified and as directed by the Engineer-in-Charge.
8Material andlabour for plain cement concrete, 1:2:4 type B-1 (using 20 mm graded mechanical crushed aggregate) forcoving, roof kerbsor mud stops, rounded or chamfered on edge complete all as specified anddirected .
9Material andlabour for providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternatebays (not exc 2 Sqm each )and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed.
10Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches,pillar, etc. but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed.
11Material and Labour brick work with sub class \"B\" bricks of class designation 10 all as per IS-1077-1992 (minimum compressive strength of brick 100 kg/Sqcm) old size bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6, complete all as specified and as directed.
12Taking down chowkats or frames with shutterareanot exceeding 1.50 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed.
13Taking down chowkats or frames with shutterarea exceeding 1.50 Square meter andnot exceeding 4.00 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed.
14Supply and fixingFactory made pressed steel frames of size 105 x 60 mm for doors fabricated from 1.25 mm thick sheet, with one or more rebate including necessary fixing lugs, hinges, lock strike plate, etc. and one shop coat of priming including plain cement concrete 1:3:6 type C-0 (using 12.5 mm graded mechanically crushed stone aggregates)in filling of door frame complete ,all as specified and as directed.
15Supply and fixingFactory made pressed steel frames of size 125 x 60 mm for doors fabricated from 1.25 mm thick sheet, with one or more rebate including necessary fixing lugs, hinges, lock strike plate, etc. and one shop coat of priming including plain cement concrete 1:3:6 type C-0 (using 12.5 mm graded mechanically crushed stone aggregates)in filling of door frame complete ,all as specified and as directed.
16Supply andfixing factory made steel windows with side hung shutter includingprojecting type hinges (withMild Steel handle of 125 mm size-01 No., MS stove enameled black tower bolts of size 100 mm-02 No. and mild steel peg stay on each shutters),without glazing bars, dovetailed or welded with one shop coat of red oxide primer,complete all as specified and as directed.
17Material and Labour for one coat of black bitumenious paint on the steel surfaces of any description not exceeding 10cm in width or girth complete all as specified and directed.
18Material and Labour for one coat of black bitumenious paint on the steel surfaces of any description exceeding 10cm in width or girth complete all as specified and directed.
19Material and labour for factory made 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
20Material and labour for factory made 35 mm thick 2nd class hard wood glazed and skeletonshutters,open rebated and prepared to receive glass , gauze etc. (without sash bars) ,edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, Section-8, clause 8.24 (a) (wood shall be kiln seasoned and chemically pressure treated) complete all as specified and as directed.
21Supply andfixing galvanized steel wire cloth 0.63mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks or galvanized wire staple and including fixing with beads supplied with joinery when fixed in panels of joinery, complete all as specified and as directed.
22Material and labour for sheet glass 3.0mm thick ordinary qualityand glazing with oil putty in square not exc 0.5 sqm in each pane and glazing with oil putty to steel window and with wooden beads to wooden shutters, complete all as specified and as directed.
23Supply and fixing of 200 mm long aluminium anodised barrel tower boltsof extruded sectioncomplete all as specified and as directed.
24Supply and fixing of 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
25Supply and fixing of floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified and as directed by the Engineer-in-Charge.
26Supply and fixing of 300mm long aluminium alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloys to door shutter complete all as specified and as directed.
27Supply and fixing of mild steel helical door spring 150 mm long fixed with screws to wooden chowkats or welding to steel chowkats,complete all as specified and directed.
28Material & Labour for Anti termite treatment at point of contact of wood work by chemical emulsion (in oil or kerosene based solution) @0.5 ltrs/hole by drilling 6 mm dia holes at a downward angle 45 degree at 150 mm centre to centre and sealing the same complete all as specified & directed.
29Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key scrubbing down with water, etc. complete all as specified and as directed.
30Material and labour rendering 15 mm thick on brick work or concrete wall surfaces in cement mortar 1:4including mixing water proofing compound @ 2% by weight of cement or as per manufacturer\"s instruction and finished fair and even without using extra cement complete all as specified and as directed.Note-WPC shall be measured and paid separately)
31Supply only integral water proofing compound, complete all as specified and as directed.
32Material and labour applying 2 to 3 mm thick wall care putty white cement basedin two or more coats to achive smooth surfaces complete all as specified and as directed.
33Material and labour for rendering 10 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:6 and finishing the surface even and smooth without using extra cement complete all as specified and as directed.
34Material and labour for preparation of old decorated brick/concrete, plastered / un--plastered surfaces of walls by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of oil bound distemper with painting roller over prepared surfaces complete all as specified and as directed.
35Material and labour for preparation of newly plastered / un--plastered surfaces of wallsandapplying two coats ofoil bound distemperover alkaline resistant primercomplete all as specified and as directed..
36Material and labour for preparation of newly plastered / un plastered surfaces of walls, pillars, cornices etc.and applying two coats of cement base paint on the walls, pillars, cornices etc. over a coat of alkaline resistant primer complete all as specified and as directed.
37Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
38Supply and fixing 25 mm thick 2nd class hardwood boarding in floors and skirting,Planed one side, with buttjoints and fixed with nails as in repair, complete all as specified and directed.
39Material and labourfor providing cement concrete 1:2:4 Type B1 using 20mm graded aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
40Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds and steel window frame glazed with putty or fixed with beads complete all as specified and as directed.
41M & L preparation of oldwoodensurfacesof any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
42Material and labour for plain cement concrete 1:3:6 type C-1 (using 20mm graded mechanically crushed stone aggregate) as in surface channels and drains, complete all as specified and directed.
43Extraforming fair finished drain or channelany girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
44Supply only mild steel butt hinge of 100mm length, cold rolled, medium weight, ISI marked complete all as specified.
45Supply only mild steel butt hinge of 50mm length, cold rolled, medium weight, ISI marked complete all as specified.
46Material and labour for preparation of new woodensurfacesof any description, not otherwise described, over10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
47Material and labour forpreparation of new steel surfacesof any description, not otherwise described, over10 cm width or girth and applying two coats of synthetic enamel paintover a coat of red oxide primer complete all as specified and as directed.
48Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness including cover filletsand false ceilingframe work of any size/ description complete all as specified and as directed.
49Supply and fixing false ceiling with fully perforated 12mm thick micro tegular edged or 10mm thick square edged GRG false ceiling tiles at all height with GRG (Glass fibre reinforced gypsum) false ceiling tiles with fully perforated 12mm thick micro tegular edged or 10mm thick square edged GRG false ceiling tile595mmx595mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4) - 1970 and light reflctance of 85% minimum to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @120grams per Sqm incl both sides) comprising of main T-runners of size 15x32mm of length 1200mm, and secondry intermediate cross T- of size 15x32mm of length 600mm to from grid moudle of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanizing @80 grams per sqm) ie 50mm long, 8mm outer diameter M*6 dash fasteners, 6mm dia fully threated hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screwscomplete all as specified and directed.
50Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators,socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etccomplete all as specified and as directed by the Engineer-in-Charge.
51Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cableFRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, on wall/ceilingand incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cableFRLS-H, 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washersand making goodthe disturbed surfaces as per existing for one light/fan point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately . PVC Conduit confirming to IS 9537 part I & III .
52Description same all as per item No. 50.00 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board,complete all as specified and as directedby Engineer-in-Charge.
53Description same allas per item No. 50.00 but for One 3 pin 5 Amps socket outlet controlled by one switch on Same board,complete all as specified and as directedby Engineer-in-Charge.
54Description same all as per srl item No 50.00 here-in-before but for one socket outlet 15 Amp with 2.50 sq mm PVC insulated, unsheathedcable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copperwire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
55Supply and fixing switch piano 5/6 Amps, flush button type, single pole, one way,230 volt , AC supply,ISI Marked, complete all as specified and directed.
56Supply and fixingswitch piano 15/16 Amps flush botton type one way 230 Volts,50 Hz , AC supply, ISI Marked, complete all as specified and directed.
57Supply and fixing socket outlet 2 in 1, 5 pin 6Ampmulti pin flush type, 230 Volts,50 Hz , AC supply, ISI Marked, complete all as specified and directed.
58Supply and fixing Socket outlet, 2 in 1, flush type 6/16 Amps 3/3 pin universal multipurpose, 230 Volts,50 Hz , AC supply, ISI Marked, complete all as specified and directed.
59Supply and fixing Fan regulator electronic, step & socket type230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed.
60Supply and fixing Ceiling rose surface bakelite 65x50mm three terminals including provn ofPVCblocks, complete all as specified and as directed.
61Supply and fixing in replacement indoor decorative LED tube light fitting box type 18/20 wattwith electronic driver, opal diffuser, high efficient PVC housing body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hzincluding 18/20 Watt LED tube rod luminaries environment friendly, high efficient, T8 with aluminium extrusion heat sinkand connecting with copper conductor flexible cablefrom ceiling rose to connector of the light complete all as specified and as directedby Engineer-in-Charge.
62Supply and fixing bldg security light light fittings 1x 60 Watt LED street light with new generation energy saving and environmental friendly long life, LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 incl mild steelpipe 40 mm bore medium grade security light bracket 1.20 metre fixing with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to MS pipe as required at site and two coats ofsynthetic enamel paintoverone coat of red oxide primer on mild steel work and making electrical connection, complete all as specified and as directed.
63Material and labour for as in replacement sub main wiring with four run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked,multi stranded copper conductor as earth continuty conductor connected to common earth dollyon wall/ceiling surfaces innon metallic PVC grey conduit medium grade, of adequate size for housing the wires,ISI markedincluding all accessories and connecting to existing main switch board/distribution board complete all as specified and as directed.Note:- (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Five runs of cable and one run of conduit shall be measured and paid as one unit length.
64Material and labour for as in replacement sub main wiring with two run of 4 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 4 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked,multi stranded copper conductor as earth continuty conductor connected to common earth dollyon wall/ceiling surfaces innon metallic PVC grey conduit medium grade, of adequate size for housing the wires,ISI markedincluding all accessories and connecting to existing main switch board/distribution board complete all as specified and as directed.Note:- (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.(ii) Three runs of cable and one run of conduit shall be measured and paid as one unit length.
65Supply and fixing in replacement sheet metal enclosure, (ISI marked), triple pole & neutral (TPN), horizontal type suitable for fixing MCB TPN 100 Amp for 415 volts, 6 way with 200 Amp rated copper bus bar, flush /surface mounting double door duly grouted in solid block wall or on wooden board in and includinglugs/thimbles duly crimped for connection, necessary PCC work and making smooth the disturbed surfacecomplete all as specified and as directed .
66Supply and fixing in replacement sheet metal enclosure, (ISI marked), triple pole & neutral (TPN), horizontal type suitable for fixing MCB, 415 volts, 4 way with 200 Amp rated copper bus bar, flush /surface mounting double door duly grouted in solid block wall or on wooden board in and includinglugs/thimbles duly crimped for connection, necessary PCC work and making smooth the disturbed surfacecomplete all as specified and as directed.
67Supply andfixing in replacement sheet metalMCB distribution board (ISI marked) for 240 volts, SPN 6 way, horizontal type with 200 Amps rated copper bus bar, double door IP-54flush /surface mountingor on wooden board, in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces complete all as specified and as directed by the Engr-in-charge.
68Supply and fixingin replacement MCB single pole, 6-32 Amps, 240 volt,10 KA ,\"C\" curve complete all as specified and as directed.
69Supply and fixingin replacementMCB single pole and neutral, 32 Amps, 240 volt,10 KA ,\"C\" curve complete all as specified and as directed.
70Supply and fixingin replacementMCB Triple pole and neutral, 63 Amps, 240 volts, 240 volt,10 KA , \"C\" curve complete all as specified and as directed.
71Supply and fixingin replacementMCB Triple pole and neutral, 100 Amps, 240 volts, 240 volt,10 KA , \"C\" curve complete all as specified and as directed.
72Supply and fixing in repair ceiling fan hook made out of MS flat 50 X 6 mm thick suitable for hanging of ceiling fan including nuts, bolts and washer with 12 mm dia round bar hook complete all as specified and directed .
73Taking down ceiling fans of any sweep of any make with down rods, blades canopy etc by disconnecting the electric connections and deposit at fan store of AGE E/M and hanging the same at location after complete repair of bldg including replacement of old fan rod with 20mm GI pipe , medium grade, 2 mtr long and connecting with copper conductor flexible cablefrom ceiling rose to fan complete all as specified and directed.
74Supply & laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 35 Sqmm nominal cross section, 3.5 core, stranded conductor, in service connections complete all as specified and directed.
75Material & labourfor earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earthwire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to earthing test pointas directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/cboth ways with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testingas in repair complete all as directed by Engineer-in-Charge and earth testing on completion .
76Amount of credit of Rs. 226128.20 for retrived old material as mentioned in Schedule \"A\" section-II of tender document in pdf form, will be deducted offline while acceptence of tender.

AI Tender Summary

OUR REF NO 45552601
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.57 Lakhs
LAST DATE 12-11-2024
Authority
Authority Name Military Engineer Services
Work Description Special Repair To Roof In No-5 Rect Coy To Prevent Leakage And Seepage In Rect Accn At 14 Gtc Subathu Under Ge Kasauli
Basic Detail
Tender No GEK-72/2024-25
Bidding Type Tender
Location
City subathu
State Himachal Pradesh
Key Dates
Publish Date 30 Oct 2024
Submission Date 12 Nov 2024
Open Date 14 Nov 2024
Finance
Tender Value 48.57 Lakhs
Tender Fee 500
EMD 97140
Exemption Available
Document List
1393564e-070f-4e12-a208-0c92852bf9ce.html
BOQ_758116.xls
GEK722425.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 12, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 14, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

1393564e-070f-4e12-a208-0c92852bf9ce.html

xls

BOQ_758116.xls

pdf

GEK722425.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender