| 1 | Withdrawing the Sub P/M Set (upto 25 HP) alongwith column pipe from the well after disconnecting the all accessories for necessary testing/checking/repairing purpose. |
| 2 | Supply & delivery at site/store of Sub pumping machineries Set directly coupled with 3 ph 400 V (+-10%), 50 Hz AC, RPM-2900wet winding type Sub Motor having Cr. Steel impeller and SS Shaft, Capacity 110-50 m3/hr., Head range-40-60 m(nominal head 58 m), P-20 HPand delivery size 100-125mm. as per direction of EIC. |
| 3 | Supply & delivery of 5” (125 mm.) I.D. and OD 140 +- 0.20 mm, 10.2 mm. avr. wallThickness, 10’(avr. 3.0 mt) long standard (16kg/cm2) PVC column pipes with both end taperedand threaded portion length must be 4\"\" with one end to be fitted with heavy gauge 10 to 13 mm. Thick , 8” long threaded pvc. socket ,all are completed as per direction of Eic. |
| 4 | Supply & Delivery of 125 mm dia / 150 mm dia (5\"/6\") standard duty PVC/CI Adoptor. |
| 5 | Supply & delivery of Sub. Copper cable of 3 core 6 sq mm 1100 V grade. |
| 6 | Lowering, fitting and fixing of all types of valves in proper position and alignment using chain pully block or crane (for diameter above 250 mm) by providing temporary support, as required, gaskets, nuts & bolts etc. all cornplete as per specification and direction of the Engineer-in-charge.[The rate Includes cost of flange joints] for 150mm dia |
| 7 | Supply of pump-motor protective device cage type (galv. iron )comprising of wire rope clamps etc as per direction of EIC. |
| 8 | Flange joint to C.l./D.l/M.S. pipes and specials including supply of rubber gasket, nuts, bolts, washers etc. of best quality to make the joint watertight at required hydraulic pressure all complete as per specification & directionof the Engineer-in-charge. |
| 9 | Installation of pumping machinery with valves, pipe & pipe specials short piece, depth gauge, pressure gauge including hoisting of column pipe, making all electrical and water line inter-connection complete as per direction including Supply of necessary materials as reqd. for the work( Including Transportation Cost). |
| 10 | Supply& delivery of fabricated MS Kiosk made from 16 SWG MS Angle (18\"\",16\"\",8\"\") incl. Providing Al busbar of 60 A rating for main Supply transmission with proper stamping and to be fixed on pedestal as per direction of EIC. |
| 11 | Supply, Delivery at site 1.1 KV grade Al rmoured cable of size 3.1/2 core 35 sq mm confirming to 1554/7098(PT) 1988 |
| 12 | Laying of two cables upto 35 sq mm in underground trench in single tire formation (horizontal) the trench size 680 mmx 760 mm average depth, with brick protection on the top of the each cable with 8 (eight) nos per mtr and 4(four) nos bricks per mtr as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed. |
| 13 | Laying of cable upto 3/3.5 core 35 sq mm - 50 sq mm on wall/surface incl. S&F MS saddle with earthing attachment in 2x10 SWG GI (hot dip) wire making holes etc. as necessary mending good damages and painting. |
| 14 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entry of XLPE/PVC cable for 3 1/2 core upto 35 sq mm. |
| 15 | Finishing end of XLPE/PVC armoured cables by crimping method incl. Supplying fixing solderless socket(dowels make), tapes, anti corrosive paste & jointing materials 35 sq mm 3.1/2 core. |
| 16 | Supply,and fixing of HT insulation rubber Mat of following sizes:-Ii)2.0 mm thick (upto 11 KV). |
| 17 | Excavation of soil for installation of Earth Electrode and filling & ramming.(a)For Soft Soil. |
| 18 | Earthing (For Equipment earthing) with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1x4 SWG GI(Hot Dip) wire (4Mts .long),13 mm dia x 80 mm long G bolts, double nuts, double washers incl. S&F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts below the.ground level as below: By ISI-Medium GI pipe. |
| 19 | Supplying & fixing earth bus bar of galvanized (Hot Dip) MS flat 50 mm x 6mm on wall having clearanc of 6mm from wall including providing drilled hole on the busbar complete with GI bolts,nuts,washers,spacing insulators etc.as required. |
| 20 | Connecting the equipments body to earth busbar including Supply,fitting & fixing 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 21 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe. |
| 22 | Add GST @ 18% (Except item no-5) |
| 23 | Add Cess @ 1% |
| 24 | N.B-Old and unserviceable material are to be submitted at store under FAWS-1 Div. otherwise deduction will be applicale as per prevailing norms. of Authority. |