}

Amendment Tender For Processing Of Processing Of Implants /Pacemaker /Accessories, Etc, On Case To Case Consignment Basis, On Rate Contract For A Period Of Two Years, Extendable Upto 6 Months Or Till The Finalization Of The Next Tender, Whichever Is La-Multi State

North Eastern Indira Gandhi Regional Institute Of Health And Medical Sciences has published Amendment Tender For Processing Of Processing Of Implants /Pacemaker /Accessories, Etc, On Case To Case Consignment Basis, On Rate Contract For A Period Of Two Years, Extendable Upto 6 Months Or Till The Finalization Of The Next Tender, Whichever Is La. Submission Date for this Tender is 11-11-2024. Industrial Process Machinery and Equipments Tenders in Multi State. Bidders can get complete Tender details and download the document.




Tender Notice

45536256
Amendment Tender For Processing Of Processing Of Implants /Pacemaker /Accessories, Etc, On Case To Case Consignment Basis, On Rate Contract For A Period Of Two Years, Extendable Upto 6 Months Or Till The Finalization Of The Next Tender, Whichever Is La
Tender
Indian
Multi State
11-11-2024

Tender Details

Amendment Tender For Processing Of Processing Of Implants /Pacemaker /Accessories, Etc, On Case To Case Consignment Basis, On Rate Contract For A Period Of Two Years, Extendable Upto 6 Months Or Till The Finalization Of The Next Tender, Whichever Is Later, For Department Of Cardiology -1. Leadless Pacemaker (Sl. No. 6.01 of BOQ) May be read as ‘US FDA /CE/DCGI/BIS approved · Volume < 0.9 cc · Weight of pacemaker < 2.0 grams · Atraumatic fixation of pacemaker to minimize perforation risk. · MRI conditional in 1.5 or 3.0 T environment. Automatically adjust sensitivity to maintain adequate sensing margins. · Must have ventricular capture management and with an active fixation mechanism that can be retracted at the time of replacement’ 2. Conduction System Pacing (Sl. No. 22 of BOQ) May be read as ‘Pre-shaped catheter for Conduction System Pacing compatible with lumen less lead.  Catheter should be able to deliver all Active Pacing fixation, stylet driven extendable helix leads with diameter of 6Fr or below.  Multiple options of shape availability for various anatomies.  Catheter should have integrated Hemostasis valve along with facility of contrast injection port.  Atraumatic radiopaque tip to facilitate imaging under fluoroscopy.  Catheter should have outer diameter of 9fr or less.  Should be supplied with compatible 0 .035” guidewire and slitter.  Helix Locking Tool (HLT) along with the catheter provides alternative to the clip – on tool used for retracting /extending of helix’

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail