| 1 | Surface excavation in Hard/dense soil n exc 30cm deep and averaging 15 cm deep and getting out in hard/dense soli complete all as specified and directed. |
| 2 | Excavating in trenches for hard/dense soil, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 4 | Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 5 | Material and labour for brick work built in cement mortar 1:6 straight or curved on plan exceeding 6 metre mean radius using sub class ‘B’ bricks (Old size bricks) complete all as specified and directed. |
| 6 | M&L for hard core of broken bricks of guage not exc 63mm deposited, spread and lovelled in layers not exc 15cm thick watered and rammed to a true surfaces complete all as specified and directed. |
| 7 | M&L for 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base complete all as specfied and as directed. |
| 8 | M&L for machine pressed precast concrete interlocking paver block any shape and size size conforming to IS-15658-2006 of60mm thickness M-35m Gradewith grey cement and pigment complete all as specified and directed. |
| 9 | Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 10 | M&L for Mild steel TMT bars 10 mm dia and over as in reinforcement cut to length bent to shape required including cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia complete all as specified and directed. |
| 11 | M&L precast reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cover slab of manholes, septic tank etc,set in cement mortar 1:4 including necessary form, moulds etc and including taking out/removal of existing unserviceable cover slab from manholes /septic tank complete as specified and directed. Note :- Reinforcement shall be measuredand paid separately) |
| 12 | Demolition of brick work, built in cement mortar complete all as specified and directed. |
| 13 | Demolition of cement concrete (un-reinforced) of any description and in any position such as in bed for drain pipe etc complete all as specified and directed. |
| 14 | M&L for cement concrete Type B1 1:2:4 (20mm graded aggregate)in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 15 | Supply and fix 150 mm dia Reinforced concrete pipes,class NP3, laid and jointed complete with collars with cement mortar 1:1 complete all as specified and directed. |
| 16 | Material and Labour PCC (1:3:6) type C-2 (40mm graded stone aggregate) as in bed to drain pipes incl packing under and completely surrounding pipes with concrete after they are laid and tested for 150 mm dia pipes complete all as specified and as directed. |
| 17 | Material and labour for brick work built in cement mortar 1:4 straight or curved on plan exceeding 6 metre mean radius using sub class ‘B’ bricks (Old size bricks) complete all as specified and directed. |
| 18 | Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregte) in foundations, filling and mass complete all as specified and directed. |
| 19 | M&L Fe-410- W(Gde-E-250) quality- B for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and directed. |
| 20 | M&L for cement concrete 1:2:4 Type B1 (20 mm graded aggrigate) as in coping chamford edge complete all as specified and directed. |
| 21 | M&L for 15mm thick rendering in cement mortar 1:4 in two layers mixed with water proofing compound @ 3% by weight of cement in top 5mm thick finishing the surfaces with fair and even without using extra cement complete all as specified and directed. |
| 22 | M/L Rendering 10 mm thick on stone masonary or surface other than fair finishes of brickwork or other side of lathing in cement mortar 1:6 on concrete surface finished even and smooth without using extra cement complete all as specified and directed. |
| 23 | M&L for preparation of new plastered surfaces of walls applying one coats exterior emulsion paint 100% acrylic, any tinted, including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and directed. |
| 24 | M&L for Preparing newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed. |
| 25 | Supply only water proofing compound complete all as specified and directed. |
| 26 | S & F Steel work in Roof trusses (framed) trussed purlins,crane gantries purlins, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces cleats etc complete all as specified and directed. |
| 27 | S&F Pre-painted galvalume aluminum zinc coating steel trapizoidal/corrugated 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete as specified and directed. |
| 28 | M&L PCC 1:2:4 type B2 using 40 mm graded 100 mm thick as in subbase or flooring finishing cement concrete surface complete as specified and directed. |
| 29 | M&L for 100 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base complete as specified and directed. |
| 30 | M&L for 40mm thick PCC type B-1, 1:2:4 (20mm graded stone aggregate) as in base complete as specified and directed. |
| 31 | Excavating in post holes (or similar holes) each n. exc0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n. exc50m and making good surface (hard/ dense) complete as specified and directed. |
| 32 | M&L for PCC type C-2, 1:3:6 using 40mm graded stone aggregate for foundation filling and mass concrete etc complete as specified and directed. |
| 33 | Material and labour Fe-410-W(GdeE-250) quality-B Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete as specified and directed. |
| 34 | Material and labour Fe-410-W(GdeE-250) quality-B Steel Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete as specified and directed. |
| 35 | Material and labour for preparation of new steel surfaces of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer exposed to view surfaces complete all as specified and as directed. |
| 36 | Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete as specified and directed. |
| 37 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulatedPVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 95 sqmm 3.5 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and directed. (Make: Havells/KEI / POLYCAB/RR Kable/Gloster cable) (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule \"A\"). |
| 38 | Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / layingunder ground electric cable complete as specified and directed. |
| 39 | Supply and laying sub class B bricks of size 23cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete as specified and directed. |
| 40 | M & L for horizontal boring across the existing road without disturbing the road surface for insertingGI pipe complete as specified and directed.Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch \"A\". |
| 41 | M&L for 80 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete as specified and directed.Make: Tata/Jindal/Bansal |
| 42 | Supply, install, testing and commissioning of LT Outdoor Feeder Pillar Box AC 415 V, 50 Hz, 3 Phase, 4 wire, totally enclosed self supporting structure/ cubicle, fully compartmentalized type, weather proof, protection IP 54 of minimum size .7m x 0.6m x 0.4m, double door type, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick outer & 2.0 mm thick inner CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement including louvers at sides duly powder coated complete for accomodating & including following accessories.INCOMER: (i) MCCB 4 pole, 415 Volts with breaking capacity36 kA of 100 Amps with fixed thermal and fixed magnetic setting- 01Nos OUTGOING: (i) MCCB 4 Pole ,415 Volts with breaking capacity18 kA of capacity 63 Amps with thermal magnetic release -02 Nos BUSBAR: (i) Al bus bar 200 Amps supported on non hygroscopic fibres and brass screws with nuts, bolts & washers - 04 NosINDICATING DEVICES (i) LED Indicating lamps for main supply indicating R, Y, B - 03 Nos.(ii)Digital ampere meter of 0-250 A, 3 phase, class 1 , including CT having CTR 400/5 - 01 No(iii)Digital voltmeter 0-500 Volts, 3 phase, class 1, - 01 No |
| 43 | Supply,connecting, testing complete of Isolation transformer 20 KVA capacity with Three Phase input and Three Phase output, 430 volts including suitable foundatin/plateform for the transformer complete all as specied and directed. Make:- ITE or equivalent. |
| 44 | Supply and fixing in repairs LED flood light 30watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete complete as specified and directed.Make Havells cat no-JETALEGANZAFIS30WLED & Eqv Bajaj, Crompton |
| 45 | Supply and fixing in repairs LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete as specified and directed. |
| 46 | Supply and fixing 1100 Volts heavy duty round sheathed multistranded three core bright annealed bare copper conductor cable of size 2.5 Sqmmfor electrical connections to the Flood lights/Street light fittings complete as specified and directed. |
| 47 | Supply and layinggalvanized iron Light grade Pipe for cable protection of size 25mm bore completeall complete as specified and directed. |
| 48 | M&L for PVC conduit pipe heavy duty 20 mm dia bends/tee including excavation earth work for laying cable in conduit & necessary mounting arrangement at pipe complete as specified and directed. |
| 49 | Supply and fixing GIpipe of 50 mm dia medium grade for fixing of street/flood lights including making of cap at top of pole/pipe with help of GI plate including nececery steel clamps, bolts, nuts and washers for fixing of flood lights at the top of pipe complete as specified and directed. |
| 50 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steek sheet 0.50 mm thick of Red colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixes with self tapping screws complete as specified and directed. |
| 51 | S&F in replacement of cross arms bracing supports clamps and back plates fabricated from structural steel section including nut, bolts, washers, welded, binding, cold as hot drilling holes for bolts in any shape or size as required duly painted with two coats of aluminium paint over a coat of red oxide primer after preparation of surface complete as specified and directed. |
| 52 | M & L for PCC work providing PCC type B2 (1:2:4) with 20 mm graded stone aggregate in foundation for Pole and finishing the surface even and smooth without using extra cement including complete as specified and directed. |
| 53 | M & L for Point wiring with 1.5 Sq mm copper conductor single core PVC insulated unsheathed FR-LS 1100 Volts multistranded drawn through and including rigid PVC casing & caping and its accessories of suitable size, high grade ISI markedin walls /roof and PVC boxes of suitable size including fixing/grouting sunken/ surface as per site requirement for mounting the switches / sockets/ regulators etc including running up of 1.5 Sq mm copper conductor flame retardant PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for : |
| 54 | One light point controlled by one way switch 5/6 amps. |
| 55 | One socket out let 5/6 amps point on the same board. |
| 56 | One socket out let 5/6 amps point on the independent board. |
| 57 | All as per item No 53 above but wiring with 2.5 sq mm single coremultistranded copper conductorincluding provision of 2.5 Sqmm PVC insulated multistranded unsheated copper conductor cable FR-LS (ISI markd) with proper colour coding as earth continuity conductor connected to common earth dolly for one socket out let 15/16 amps point on the independent board complete all as specified and directed. |
| 58 | S&F switch piano flush type 5/6 amps single pole one way complete all as specified and directed. |
| 59 | S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed. |
| 60 | S&F Switch socket combination2 and 3 Pin, 5/16 amps, multipurpose flush non shutter, non inter locking type white ivory finish with complete as specified and directed. |
| 61 | S&F in ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete as specified and directed. |
| 62 | S&F IP 20, Class I, LED Mirror light fitting 1 x 10 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with PC housing 2 feet long, integrated type, with high efficiency PMMA diffuser,integrated high efficiency electronic driver & surge suppressor of 2 KV or more,operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete with all accessories internally prewired and including twin core twisted flexible copper conductor cable of suitable size complete as specified and directed. Make :- Havellsor equivalent to Crompton/Surya/Philips/Bajaj. |
| 63 | S&F of Bulk head luminaire suitable for 10 WattLED (or nearest next higher wattage) light IP66 grade, luminaire efficiency not less than 120 lumens/watts with and including 10 watt LED (or nearest next higher wattage) lamp and connecting up with and including PVC insulated3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting complete as specified and directed. |
| 64 | S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 4 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, ertth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete as specified and directed. |
| 65 | S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete as specified and directed. |
| 66 | S&F MCB, Single pole, 5 to32 amps, 240 volts, ‘C’ curve, 10 KAcomplete as specified and directed. |
| 67 | Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, includig necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing on completion all as directed and specified. |
| 68 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulatedPVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 4 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and directed.Make: Havells/KEI / POLYCAB/RR Kable/Gloster cable. (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule \"A\"). |
| 69 | M&L for 32 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and directed. Make: Tata/Jindal/Bansal |
| 70 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |