| 1 | Wiring for Light/ power plug wiring with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 2 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 3 | a) 5/6 A switch |
| 4 | b) 3 pin 5/6 A socket outlet |
| 5 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 6 | a) 6 Module (200 mmX75 mm) |
| 7 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator) |
| 8 | a) 4 - way (4+12) , Double door. |
| 9 | Supplying and fixing 5 A to 32 A rating,240/415 V, 10 kA \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 10 | a) Single Pole |
| 11 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing andcommissioning etc. as required |
| 12 | a) 40 A |
| 13 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 14 | a) 3.5 x 300 sqmm (70mm) |
| 15 | Supplying of one number XLPE insulated PVC outer sheathed with galvanised round steel wire or steel srtip armoured aluminium conductor power cable of 1.1 Kv grade of size 300 sq.mm x 3.5 core conforming to IS 7098 (Part-I) 1988 amended upto date. |
| 16 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the open surface as required. |
| 17 | a) Above 180 sq.mm and upto400 sq.mm |
| 18 | Laying of one number PVC insulatedand PVC sheathed / XLPE power cable of 1.1.KV grade of following size in the existing DWC/RCC/ HUME/METAL pipe as required. |
| 19 | a) Above 185 sq.mm and upto400 sq.mm |
| 20 | Supplyingh and laying of following size DWC HDPE pipe ISI marked alomg with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (50 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. |
| 21 | a) 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 22 | Supplying and layingof DWC HDPE pipe of following size, ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 16205 (Part 24): 2018/IS 14930 (Part 2) : 2001, complete with fitting and cutting, jointing etc. on surface/wall including providing clamping arrangement etc asrequired. |
| 23 | a) 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 24 | Supplying and layingof DWC HDPE pipe of following size, ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 16205 (Part 24): 2018/IS 14930 (Part 2) : 2001, complete with fitting and cutting, jointing etc. on ground/surface etc asrequired. |
| 25 | a) 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 26 | Demolishing cement concrete/ bituminous road manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (0.30m X 0.30m X4.0 m) trench. |
| 27 | Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete (0.2m X 0.2m X 4.0 m) trench , but excluding DWC /GI Pipe dia. |
| 28 | Providing, laying and fixing of 100mm dia G.I. pipe ( medium class) in theexisting trench complete with G.I. fittingsetc. as required. |
| 29 | Supplying and fixing of 400AmpsOn load Change over switch with sheet steel enclosure including necessary connection etc. as required Similar to L&T Cat no. CO44000OSOO or its equivalent |
| 30 | Supplying and fixing of 400Amps FP MCCB 36kA withsheet steel enclosure including necessary connection etc. as required Similar to HavellsCatno. HLLSEB40400 & IHEGFP or its equivalent. |
| 31 | Fabrication, Installation testing and commissioning of LTOutdoor type self supported cubical Street light control panel box made of 2.00 mm CRCA Sheet of size 1.5 m (H)x 0.9m (W)x 0.7 m (B) with frontopening, double leaf hinged door with locking arrangement. Panel struture comprising 40 mm x 6 mm MS Agle of length 18 mtrs. welded to form structureper the direction of E in C suitablefor mounting400 Amps On load change over switch and complete withall the neccessary internal connectionand the panel isduly painted with two coats of metal primer(Red Oxide) and two coats of synthetic enamel paint( silver colour) including foundation workconforming to section 4 of CPWD specification for Electrical works part IV substation 2007 etc complete as required. |
| 32 | Providing Earthing with safe earthing electrode of galvanization 80 to 100 microns length 2000 mm, 48mm diaand inner space to be filled with crystaline conuctive mixture including filling - up with electrodite (Back fill Compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking attagement etc. as required. (Similar to ASHLOK make SEE brand safe earthing or equivalent) |