Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Supplying and Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit ISI 16 gauge with modular type switch, modular plate,suitable GI box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc as required. |
| 2 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. |
| 3 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc. as required.. |
| 4 | Supplying and Wiring for circuit/ submain line with 2x1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit ISI 16 gauge along with 1 no 1.5 mm² FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 5 | .....do..... but 2x2.5 mm² + 1x2.5 mm² earth wire |
| 6 | .....do..... but 2x4 mm² + 1x4 mm² earth wire |
| 7 | .....do.....but 2x6 mm² + 1x6 mm² earth wire |
| 8 | .....do..... but 2x10 mm² + 1x6 mm² earth wire |
| 9 | .....do..... but 2x16 mm² + 1x6 mm² earth wire |
| 10 | .....do..... but 4 X 4 mm² + 2 X 4 mm² earth wire |
| 11 | .....do..... but 4 X 6 mm² + 2 X 6 mm² earth wire |
| 12 | .....do..... but 4 X 10 mm² + 2 X 6 mm² earth wire |
| 13 | .....do..... but 4 X 16 mm² + 2 X 6 mm² earth wire |
| 14 | Supplying and drawing 2 x 1.5 sq mm sizes of FRLS PVC insulated copper conductor, single core cable in the exisiting surface/ recessed steel/PVC conduit as required with connection complete. |
| 15 | .....do..... but 3 X 2.5 sq mm |
| 16 | .....do..... but 3 X 4 sq mm |
| 17 | .....do..... but 2 X 6 sq mm |
| 18 | .....do..... but 3 X 6 sq mm |
| 19 | .....do..... but 2 X 10 sq mm |
| 20 | .....do..... but 2 X 16 sq mm |
| 21 | .....do..... but 2 X 25 sq mm |
| 22 | .....do..... but 1 X 35 sq mm |
| 23 | .....do..... but 1 X 50 sq mm |
| 24 | S/F of PVC Batten/casing caping of 20X12 MM size including suitable size of PVC cover and others all accessories as required. |
| 25 | .....do..... but 25X12 MM size |
| 26 | .....do..... but 32X12 MM size |
| 27 | Supplying and fixing of Batten / Angle Holder on existing round sheet or on round block including connections etc. as required. |
| 28 | Supplying and fixing 5/6 amps modular type switch on existing modular type plate & switch box including connections but excluding modular plate etc. as required. |
| 29 | .....do..... but 2-way 5/6 amp switch |
| 30 | .....do..... but 15/16 amp switch |
| 31 | .....do..... but 5 pin 5/6 amp socket outlet |
| 32 | .....do..... but 6 pin 15/16 amp socket outlet |
| 33 | .....do..... but stepped type electronic fan regulator |
| 34 | .....do..... but modular blanking plate. |
| 35 | Supplying and fixing 1 or 2 module size/ modules, PVC box along with modular base & cover plate for modular switches in recess/surface etc as required. |
| 36 | .....do.....but 3 module |
| 37 | .....do.....but 4 module |
| 38 | .....do.....but 6 module |
| 39 | .....do.....but 12 /16 module |
| 40 | Supplying and fixing 1 or 2 module Modular base & cover plate on existing modular metal boxes etc. as required. |
| 41 | .....do.....but 3 module |
| 42 | .....do.....but 4 module |
| 43 | .....do.....but 6 module |
| 44 | .....do.....but 8 module |
| 45 | .....do.....but 12/18 module |
| 46 | Providing and fixing 125 amp, 16 KA, rating and breaking capacity TP MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. |
| 47 | ...do- but 150 / 160 amp 35 KA |
| 48 | .....do..... but 250 amp 35 KA MCCB |
| 49 | .....do..... but 400 amp 35 KA MCCB |
| 50 | .....do..... but 630 amp 50 KA MCCB |
| 51 | Providing and fixing 125 amp, 36 KA, rating and breaking capacity 4P MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. |
| 52 | .....do..... but 250 amp 36 KA MCCB |
| 53 | .....do..... but 400 amp 50 KA MCCB |
| 54 | .....do..... but 630 amp 50 KA MCCB |
| 55 | Supplying and fixing of 12-way, double door prewired SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 56 | Supplying and fixing 4 way (4+12), double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 57 | do... but 6 way (6 + 18), double door TPN DB |
| 58 | do... but 8 way (4 + 24), double door TPN DB |
| 59 | Supplying, installation, testing and commissioning of surface/ recess mounting, vertical type, 415 volts, prewired, TPN MCB distribution board of sheet steel, dust protected, duly phosphatized and powder painted, inclusive of 200 amps tinned copper busbar, common neutral link, earth bar, din bar for mounting MCB\"s , detachable gland / knock out plate and superior make terminal connectors for all incommining and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link and ready for installation of 4 ways (4+12) double door (but with out MCB\"s and incommer MCCB) as required. |
| 60 | ..do.. but 8 way (4 + 24), double door VTPN DB |
| 61 | Supplying and fixing 5 amps to 32 amps rating single pole, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 62 | .....do..... but 40 to 63 amp SP MCB |
| 63 | .....do..... but 5 to 32 amp DP MCB |
| 64 | .....do..... but 40 to 63 amp DP MCB |
| 65 | .....do..... but 5 to 32 amp TP MCB |
| 66 | .....do..... but 40 to 63 amp TP MCB |
| 67 | .....do..... but 5 to 32 amp 4P MCB |
| 68 | .....do..... but 40 to 63 amp 4P MCB |
| 69 | Supplying and fixing 25 amps rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 70 | .....do.....but 40 amps DP RCCB |
| 71 | .....do.....but 63 amps DP RCCB |
| 72 | Supplying and fixing 40 amps rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 73 | .....do.....but 63 amps 4P RCCB |
| 74 | Supplying and fixing 2P / 4P MCB sheet steel enclosure on surface/ recess for 415 volts complete with suitable bus bar for neutral including connections, testing and commissioning etc. as required. |
| 75 | Supplying and fixing TP/4P MCCB sheet steel enclosure on surface/ recess for 415 volts MCCB upto 250Amps complete with suitable bus bar for neutral including connections, testing and commissioning etc. as required. |
| 76 | Supply and fixing of SPN Automatic Changeover switches with Current Limiter (ACCL) 400V, 30A/9-30A capacity on board/DB\"s etc complete with connections in all respects. |
| 77 | SITC of Motorised Automatic Changeover/ATS switch 4 pole, 125 Amps in existing panel chamber alongwith all acessories complete with all connections as required. |
| 78 | SITC of Motorised Automatic Changeover/ATS switch 4 pole, 250 Amps in existing panel chamber alongwith all acessories complete with all connections as required. |
| 79 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure/ HDPE FRP Chamber with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 80 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 Meter bellow ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 81 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure/ HDPE FRP Chamber with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 82 | Supplying and laying 25 mm X 5 mm copper strip on surface/recess as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 83 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 84 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade upto 35 mm² size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 85 | .....do.....but above 95 mm² and upto 185 mm² |
| 86 | ...do.....but above 185 mm² and upto 400 mm² |
| 87 | Laying/Removal of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size upto35 mm² direct in ground including excavation and refilling the trench etc as required. but excluding sand cushioning and protective covering. |
| 88 | ........do..... but 35 mm² to 95 mm² cable |
| 89 | ........do..... but 95 mm² to 185 mm² cable |
| 90 | ........do..... but 185 mm² to 400 mm² cable |
| 91 | Supplying and making end termination with brass compression gland and aluminium lugs for 4 core 10 mm² (25mm) size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 92 | ..do...but for 4 core 25 mm²(28mm) PVC cable. |
| 93 | ..do...but for 3 ½ core 50 mm²(35 mm) PVC cable |
| 94 | ..do...but for 3 ½ core 95 mm²(45 mm) PVC cable |
| 95 | ..do...but for 3 ½ core 150 mm²(50 mm) PVC cable |
| 96 | ..do...but for 3 ½ core 300 mm²(70 mm) PVC cable |
| 97 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3 ½ core 50 mm² PVC cable size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 98 | .....do.....but for 3 ½ core 95 mm² PVC cable |
| 99 | .....do.....but for 3 ½ core 120-185 mm² PVC cable |
| 100 | .....do.....but for 3 ½ core 240 mm² PVC cable |
| 101 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3 core 120-185 mm², XLPE aluminium conductor cable of 11 kV(UE) grade as required. |
| 102 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3 core 120-185 mm², XLPE aluminium conductor cable of 11 kV(UE) grade as required. |
| 103 | SITC of Thermoplastic Cable Junction Box IP 65 Dimensions (LXBXH) 155 x 210 x 92 mm with metric knockouts for cable entry suitable for 10-16 sq.mm PVC sheathed armoured cable with 5 pole Terminal Set and one no. 5-32A SP MCB \"C\" Curved for cable connections fixed on support (DIN Rail) with provision of continuity of loop earthing between I/C & O/G cables as required, equivalent to Hensel Cat No.KF1616G (Make-Hensel / Siemens) |
| 104 | Disconnection, dismantalling & Shifting of old Electric panel / Feeder pillar. After dismantalling the panels to be sent to central / zonal store, as per direction of site incharge. |
| 105 | Supplying and fixing of Digital Ammeter equivalent to Make: Secure & Model DPM I310 in existing panel/DB complete with all connections, testing and commissioning etc as required. |
| 106 | Supplying and fixing of Digital Voltmeter equivalent to Make: Secure & Model DPM V310 in existing panel/DB complete with all connections, testing and commissioning etc as required. |
| 107 | Supplying and fixing of Digital Multifunction Meter equivalent to Make: Secure & Model Elite 102 in existing panel/DB complete with all connections, testing and commissioning etc as required. |
| 108 | SITC of 100/5- 600/5 CT burdan 15 VA, tap wound and ring type CL -1 complete with all connections including all mounting accessories in all respect. |
| 109 | SITC of 800/5- 1200/5 CT tap wound and ring type CL -1 complete with all connections including all mounting accessories in all respect. |
| 110 | SITC of LED Indicator 230V, AC complete with all connections including all mounting accessories in all respect. |
| 111 | SITC of Wall mounting fan 400 mm Sweep revolving type with speed regulator. |
| 112 | SITC of 240 V, 450 MM sweep, 900 RPM heavy duty exhaust fan in existing opening including making good finish the damage with plaster and all masonary work, connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. |
| 113 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, Service Value not less then 7, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 114 | SITC of LED light fitting 600mm length minimum 1000Lumen with mounting rail box / aluminium extruded Batten suitable for surface, wall and conduit mounting with acessories and prewired with both side end cap equivalent to Havells Cat no. LUMILINE+BS10WLED865SPCSS. Minimum Two years warranty should be provided. |
| 115 | SITC of LED light fitting 1200mm length minimum 2000Lumen with mounting rail box / aluminium extruded Batten suitable for surface, wall and conduit mounting with acessories and prewired with both side end cap equivalent to havells cat no. LUMILINE+BS20WLED865SPCSS. Minimum Two years warranty should be provided. |
| 116 | SITC of Round recess/surface mounted LED slim/sleek down light fitting with LED Driver minimum 1000 lumen suitable for Armstrong/Grid ceiling equvilant to Havells cat no. EDGEPRONEORDDLR 12WLED857S. Minimum Two years warranty should be provided and certificate should be endorsed by OEM or his representative |
| 117 | SITC of Round recess/surface mounted LED slim/sleek down light fitting with LED driver minimum 2000 lumen suitable for Armstrong/Grid ceiling equvilant to Havells cat no. EDEGPRONEORDDLR18WLED8587S . Minimum Two years warranty should be provided and certificate should be endorsed by OEM or his representative |
| 118 | SITC of 2\"x2\" fully diffused recess/surface mounting LED luminaire, minimum 3600 lumen as light source, suitable for Armstrong/Grid Ceiling complete as required includung all connections equivalent to Havells no. VENUSNEO2X2PLR36WLED857STTR. Minimum Two years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative. |
| 119 | SITC of LED street light made up of pressure die cast aluminium housing with toughened glass / polycarbonate covers and individual high power LEDs with secondary optics, minimum 4000 lumen, 3600/5700 K, warm/cool as required. IP66 protection, impact resistance of IK07 & 10 KV external SPD on pole, equivalent to Havells Cat No.ENDURASUNDOWNSL40WLED765PASYBOPC. Minimum Two years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative. |
| 120 | SITC of LED street light made up of pressure die cast aluminium housing with toughened glass / polycarbonate covers and individual high power LEDs with secondary optics, minimum 7000 lumen, 3600/5700 K, warm/cool as required. IP66 protection, impact resistance of IK07 & 10 KV external SPD on pole, equivalent to Havells Cat No.ENDURASUNDOWNSL70WLED765PASYBOTG. Minimum Two years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative. |
| 121 | SITC of LED Integral Flood light fitting, Energy saving, environmental friendly, long life, made up of aluminuim pressure die cast housing with toughened glass / polycarbonate cover, minimum 10000 lumen output and individual high power LEDs with secondary optics, IP66 protection, impact resistance of IK07 & 10 KV external SPD equivalent to Havells Cat No. JETAQUANTOPLUSFLP100WLED757SYM along with mounting brackets assembly. Minimum Two years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative. |
| 122 | SITC of 120 watt LED midbay / highbay luminair with aluminium heat sink for efficient heat dissipation and highly effective optics for maximum illumination for varied industrial applications, minimum 12000 Lumens, equivalent to Havell\"s Cat No. GAZELLAHBP120WLED857PBOTG along with mounting brackets assembly. Minimum Two years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative. |
| 123 | Supply and Fixing of M.S. tubular pole SP-5, 7.5 Meter length with suitable canopy and cross arm single/ double as required. The pole shall be grouted in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling as required. |
| 124 | Supply and Fixing of M.S. tubular pole SP-32, 9.0 Meter length with suitable canopy and cross arm single/ double as required. The pole shall be grouted in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling as required. |
| 125 | Providing and making of steel / rail pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc. as required (volume of pole/pipe not to be deducted). |
| 126 | Dismantling of pole/ street light standard/ strut embedded in brick ballast foundation etc. as required. |
| 127 | Earth work in excavation in soft soil by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m. |
| 128 | Providing Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 129 | 12 mm Cement Plaster of Mix 1:6 ( 1 Cement : 6 Fine Sand) |
| 130 | Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 Meters lead of area beyond 3 sq.meters |
| 131 | Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within50 Meters lead as per direction of Engineer - in- charge |
| 132 | Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade Two or more coats on new work |
| 133 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete |
| 134 | Demolishing brick work in mortar manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable materialwithin 50 Meters lead as per direction of Engineer-in-charge. |
| 135 | Re-lettering with black Japan paint of approved brand and manufacture. |
| 136 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer all complete. |
| 137 | Disposal of building rubbish / malba / similar unserviceable, dismantledor waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or asapproved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 138 | Spray Painting of double coat of Electric Panel/Feeder after removal of old layer of paint, rusting etc. and providing the red oxide paint over the surface uniformly if required before spray painting including etc.The work shall be completed in all respect including repair including repair by welding/Denting and black paint on base chanel and MS frame as required (Only painted surface shall be measured for payment). |
| 139 | Painting of electric pole and number making if required (5 mtr. to 8 mtr. long pole) with 1 coat of aluminium paint over redoxide primer after proper cleaning of rusted surface as required complete in all respects. |
| 140 | Painting of electric pole and number making if required (5 mtr. to 8 mtr. long pole) with 1 coat of aluminium paint after proper cleaning of rusted surface as required complete in all respects. |
| 141 | Painting of electric pole and number making if required (2.4 mtr. to 4.5 mtr. long pole) with 1 coat of aluminium paint over redoxide primer after proper cleaning of rusted surface as required complete in all respects. |
| 142 | Painting of electric pole and number making if required (2.4 mtr. to 4.5 mtr. long pole) with 1 coat of aluminium paint after proper cleaning of rusted surface as required complete in all respects. |
| 143 | Supply and laying of Aluminium conductor, XLPE insulated, Un-armuored, PVC sheathed cable, 1100V grade, 4 core 25 mm² at a depth of 750mm below ground level including excavation and refling the trench over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top as directed by the Engineer-Incharge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. The cable shall be laid by boring the road as required and compaction of soil & repairing of surface in prior shape shall be done properly. |
| 144 | Supply and laying of copper conductor, XLPE insulated, armuored, PVC sheathed cable, 1100V grade, 3 core 1.5 mm² at a depth of 750mm below ground level including excavation and refling the trench over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top as directed by the Engineer-Incharge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. The cable shall be laid by boring the road as required and compaction of soil & repairing of surface in prior shape shall be done properly. |
| 145 | Do -- But 4 core 10 sqmm Aluminium armuored cable. |
| 146 | Do -- But 4 core 70 sqmm Aluminium armuored cable. |
| 147 | Do -- But 4 core 150 sqmm Aluminium armuored cable. |
| 148 | Do -- But 4 core 240 sqmm Aluminium armuored cable. |
| 149 | Do -- But 4 core 300 sqmm Aluminium armuored cable. |
| 150 | Do -- But 4 core 400 sqmm Aluminium armuored cable. |
| 151 | Do -- But 3 core 1.5 sqmm Copper armuored cable in existing RCC/ HUME pipe/ tray etc. |
| 152 | Do -- But 6 core 1.5 sqmm Copper armuored cable in RCC/Hume/ Metal pipe |
| 153 | Do -- But 4 core 10 sqmm Aluminium armuored cable in RCC / Hume/ Metal pipe. |
| 154 | Do -- But 4 core 35 sqmm Aluminium armuored cablein RCC / Hume/ Metal pipe. |
| 155 | Do -- But 4 core 50 sqmm Aluminium armuored cablein RCC / Hume/ Metal pipe. |
| 156 | Do -- But 4 core 150 sqmm Aluminium armuored cable in RCC / Hume/ Metal pipe. |
| 157 | Supply, erection, testing and commissioning of factory fabricated metal clad dust and vermin proof- floor/wall mounted/ recessed/ surface feeder pillar / Panel double/ Single door , 150-200 mm depth duly powder coated spray painted with separate chamber for instruments (e.g. Ampere meter, Volt meter, frequency meter, KWH meter etc.) & switch gears (like I/C & O/G MCB\"s/MCCB\"s, C/o switch with extentionable/rotary handle etc.) as required. The feeder pillar/ panel shall have nonhygroscopic supports with detachable side with hinge and locking. The panel/ feeder pillar should be made with 1.6 CRCA sheet. The panel shall be comprised of indicator and feeder nomenclature (if required) as per direction of site-in-charge. |
| 158 | Supply, erection, testing and commissioning of factory fabricated metal clad dust and vermin proof- floor mounted 800A cap 440 V, 50 HZ,3 phase and neutral electric feeder pillar single/ double door 400 mm depth duly powder coated spray painted with separate chamber for instruments (e.g. ampere meter, volt meter, frequency meter, KWH meter etc.) & switch gears (like I/C & O/G MCB\"s/MCCB\"s, C/o switch with extentionable/rotary handle etc.). The feeder pillar/ panel shall have 500Amp, 415V TPN electrolyte aluminium bus bar as per IS 8623 insulated with heat shrink sleeve and mounted on nonhygroscopic supports with detachable side with hinge and locking. The switches shall be completed with lug and cable gland of suitable size of cables with connection as required. The feeder pillar should be made with 2 mm CRCA sheet. The feeder pillar should be fixed on M.S. channel 75mm X 40mm X 6mm size and mounted on M.S. angle iron 50mm X 50mm X 5mm size frame 450mm height with cross support completed as per direction of site in charge. The panel shall be comprised of indicator and feeder nomenclature as per direction of site-in-charge. |
| 159 | SITC of 240 V, 450 MM sweep, heavy duty air cerculator wall fan including making good finish the damage with plaster and all masonary work, connection with 1.5 sqmm PVC insulated, copper conductor, single core etc. |
| 160 | SITCofNew Float cum boost charger (Fcbc), with VRLA, Ni-Cd batteries. Usage for Substation DC supply. Input AC Voltage (220, +/-10%) and output DC Voltage (24V ,25A). Voltage not less than 24 V. With AC input voltmeter (with selector switch, Output voltmeter (0-250V DC), Ouptput Ammeter (0-75A DC), Battery Ammeter (60-0-60 A). Indications-input ON Lamp, Output ON Lamp, Charger ON Float LED, Charger ON Boost LED. With Soft starting charging and Protection. |
| 161 | Shifting of 200kVA DG Set including Connection/ Disconnetion, Installation, termination and complete with all connection, testing etc as per required. |
| 162 | Supply and laying of aluminium conductor, XLPE insulated, armuored, PVC sheathed cable, 1100V grade, 1.0CX800 sqmm at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top. On surface, the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. The cable shall be laid by boring the road as required and compaction of soil & repairing of surface in prior shape shall be done properly.. |
| 163 | SITC of spring charge motor/ motorized operating Mechanism with electrical closing 220-240V AC 50/60Hz V for existing ACB with complete connection as required. Make: siemens, 3WT9831-1JK00 |
| 164 | SITC of Shunt Release or closing coil suitable for continuous operation 220-240V AC 50/60Hz V for existing ACB with complete connection as required. Make: siemens, 3WT9831-1JK00 |
| 165 | SITC of under voltage (U/V) release instantaneous 380-415 V AC 50/60Hzfor existing ACB, with complete connection as required. Make siemens. |
| 166 | SITC of Auxiliary terminal block for drawout circuit breaker for existing ACB, with complete connection as required. Make siemens. |
| 167 | SITC of Auxiliary switch block 2 change over, with complete connection as required. Make siemens. |
| 168 | SITC of Position signal switch for withfrawable breaker, 3NO+3NC, 2NO+2NC, 1NO+1NC, with complete connection as required. Make siemens. |
| 169 | SITC of 5 digit operating cycle counter, with complete connection as required. Make siemens. |
| 170 | SITC of Blocking Device for preventing opening of cubical door in service position: for withdrawable breaker, with complete connection as required. Make siemens. |
| 171 | SITC of Castell lock Mounting kit (to prevent unauthorized closing of the circuit breaker), with complete connection as required. Make siemens. |
| 172 | SITC of Castell lock , with complete connection as required. Make siemens. |
| 173 | SITC of Door Sealing frame , with complete connection as required. Make siemens. |
| 174 | SITC of External current sensor for N-conductor with copper connectors( for 3P ACB with neutral or E/F protection) , with complete connection as required. Make siemens. |
| 175 | SITC of ACB Mounting Base for existing ACB, replacement existing ACB Mounting Base for ACB with complete connection as required. Make siemens. |
| 176 | SITC of 3 phase fully automatic star delta motor stater 7.5 to 10 HP,relay range 6 to 14 Amp (with single phase preventer), with water level controller alongwith all acessories complete with all connections as required. |
| 177 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) for size 25 mm nominal outer dia pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing as required. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 178 | do- but 40 mm nominal outer dia Pipes |
| 179 | do- but 50 mm nominal outer dia Pipes |
| 180 | do- but 80 mm nominal outer dia Pipes |
| 181 | P/F G.I. Pipe 15 mm dia \"B\" class ISImark completed with G.I. fittings including trenching and Refilling etc i/c cutting and makin good the wall etc. |
| 182 | P/F G.I. Pipe 20 mm dia \"B\" class ISImark completed with G.I. fittings including trenching and Refilling etc i/c cutting and makin good the wall etc. |
| 183 | P/F G.I. Pipe 25 mm dia \"B\" class ISImark completed with G.I. fittings including trenching and Refilling etc i/c cutting and makin good the wall etc. |
| 184 | P/F G.I. Pipe 32 mm dia \"B\" class ISImark completed with G.I. fittings including trenching and Refilling etc i/c cutting and makin good the wall etc. |
| 185 | P/F G.I. Pipe 40 mm dia \"B\" class ISImark completed with G.I. fittings including trenching and Refilling etc i/c cutting and makin good the wall etc. |
| 186 | P/F G.I. Pipe 50 mm dia \"B\" class ISImark completed with G.I. fittings including trenching and Refilling etc i/c cutting and makin good the wall etc. |
| 187 | P/F G.I. Pipe 80 mm dia \"B\" class ISImark completed with G.I. fittings including trenching and Refilling etc i/c cutting and makin good the wall etc. |
| 188 | Making connection of G.I. distribution branch with G.I. main of 25 to 40 mm nominal bore sizes by providing and fixing tee, including cutting and threading the pipe etc. complete |
| 189 | Making connection of G.I. distribution branch with G.I. main of 50 to 80 mm nominal bore sizes by providing and fixing tee, including cutting and threading the pipe etc. complete |
| 190 | Fixing water meter and stop cock or making connection 15 mm to 20 mm size in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). |
| 191 | .....do.....but G.I. Pipe 100 mm dia. |
| 192 | Providing and fixing gun-metal gate valve 25mm dia with C.I.wheel of approved quality (screwed end). |
| 193 | Providing and fixing gun-metal gate valve 40mm dia with C.I. wheel of approved quality (screwed end). |
| 194 | Providing and fixing gun-metal gate valve 50mm dia with C.I. wheel of approved quality (screwed end). |
| 195 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 50mm nominal bore Horizontal type. |
| 196 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 50mm nominal bore Vertical type. |
| 197 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 198 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball 20 mm nominal bore, 120 mm long, weighing not less than 198 gms. |
| 199 | do but 25 mm nominal bore, 152mm long, weighing not less than 440 gms. |
| 200 | do but 40 mm nominal bore, 206mm long, weighing not less than 690 gms. |
| 201 | do but 50 mm nominal bore, 242mm long, weighing not less than 1240 gms. |
| 202 | Providing and fixing ball valve ( CPVC) of approved quality, high or low preassure, with plastic floats complete 25 mm nominal bor complete in all respect. |
| 203 | Providing and fixing ball valve ( CPVC) of approved quality, high or low preassure, with plastic floats complete 50 mm nominal bor complete in all respect. |
| 204 | Supply of PVC insulation Tape |
| 205 | Supply of Single Phase kwh electronic energy meter 10-60A capacity class-1, counter/LCD display |
| 206 | Supply of Three Phase four wire kwh electronic energy meter 10-60A capacity class-1, direct base counter/LCD display. |
| 207 | Supply of SMF Battery Exide Make 12V, 18Ah. |
| 208 | Supply of socket set ( 17 socket + 6 Accessories)with box. |
| 209 | Supply of Double Ended Spanner Sets. size 1/8x3/16, 3/16x1/4, 1/4x5/16, 5/16x3/8, 3/8x7/16, 7/16x1/2, 1/2x9/16, 9/16x5/8, 5/8x3/4. Model DW-09 Taparia Make. |
| 210 | Supply of Allen Key Sets, 9 pics set (Size-1.5,2,2.5,3,4,5,6,8,10), model-KM9V make: Taparia |
| 211 | Supply of Hand Operated Crimping Tools 10-95mm |
| 212 | Supply of Hand Operated Insulation tester (up to 1000 Volt, 0-200 Mega Ohms), Eddy current dynamometer, Polycarbonate body, |
| 213 | Supply of Digital Earth Resistance Tester (0-10-1000 Ohms) |
| 214 | Supply of Electrical Seafty Rubber Insulating Hand gloves Full fingures, cuff length 6 to 10 inch upto 33 KV. |
| 215 | Supply ofdigital LED Emergency exit/ lift signage Board double side display. |
| 216 | Supply of High Di-electric strenth Insulating Rubber Chequered mat upto 33 kV , size 1 mtr x 2 mtr x 3 mm thick. |
| 217 | Supply of Combination Pliers minimum 165 mm length taparia make (Item code:1621-6). |
| 218 | Supply of Long Nose Pliers ( Flat or Round Nose. item code:1421-6N, 1431-6) minimum 165 mm length, Taparia Make. |
| 219 | Supply of Screw Driver Sets (6.0x0.8, 3.5x0.5 phillips 0 square poker, Phillips 1+Extension Rod. Taparia Make Item Code:840. |
| 220 | Supply of Line Testers Yellow/ Green, minimum Lenght 125 mm, Taparia Make Item code: 814. |
| 221 | Supply of screw Driver kits (Blister Packing) consisting of 8 screw drivers 713, 922, 725, 828, 912, 712, 937 I, P5 861 75. Taparia Make Item code 1013. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy