| 1 | Taking down old treatment/cement or lime cement plaster on brick or stone or concrete walls and ceiling surface, etc. including raking out joints, hacking for key, scrubbing down with water, etc.completed including removing of waste material whereas directed by EIC |
| 2 | Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 |
| 3 | M&L for brushing neat cement slurry with 3.0kg of cement per sq. metre |
| 4 | M&L for dubbing out average 20mm thick on irregular face of walls with 1:4 cement plaster |
| 5 | M&L for rendering 15mm thick in CM 1:4 on roof surface and using 2% W.P. compound by weight of cement completed all as specified and directed by EIC. (W.P. compound measured and paid seperately) |
| 6 | Supply only Integral waterproofing compound all as specified and as directed by EIC (make: Dr. fixit,STP,IWL or equivalent). |
| 7 | M&L for Wire brushing and cleaning top surface of cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq. m, blinded with grit or pea size gravel @ 0.006 cu.m per sq.m, and lightly tampered |
| 8 | M&L for applying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. (APP membrane make: STP,IWL or equivalent) (test certificate required). |
| 9 | M&L for applying aluminium paint over surfaces of any description, over 10cm in width or girth,not otherwise described (make: asianpaints,berger,nerolac or equivalent) (test certificate required). |
| 10 | Demolition of brickwork or stone/ boulder masonry, built in cement or cement lime mortar including allquoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 11 | M&L for Brickwork with class designation 75 (Kgf/cm²), subclass ‘B’ bricks, straight or curved on plan to any radius inhalf brick thick walls built in 1:4 cement mortar |
| 12 | M&L for cleaning with epoxy cloth and exposed corroded re-bars by chiseling out enough cavity to access entire dia of corroded bars and applying anti corrosive chemical to the reinforcement. (Chemical manufacturer :- Sika/Pidilite/Fosroc or equivalent) (test certificate required). |
| 13 | M&L for epoxy based primer/bonding material for bonding old concrete surface to new mortar (Chemical manufacturer:-Sika/Pidilite/Fosroc or equivalent) (test certificate required). |
| 14 | M&L for 10mm thick cement mortar (1:4) using high flexural and high tensile strength polymer chemical as dubbing coat rough finished all as specified and directed (Chemical manufacturer:-Sika/Pidilite/Fosroc or equivalent) (test certificate required). |
| 15 | M&L for rendering 05mm thick plaster in cement mortar 1:3 on concrete surfaces in ceiling finished even and smooth without using extra cement complete as specified or directed |
| 16 | Dismantling boarding, any description, fixed in any position with all fittings including removal to store etc or as directed |
| 17 | M&L for applying 3mm thick wall care putty on wall including complete removing by Washing, rubbing down and stopping of old distempered and painted surfaces (make:- JK super, Aditya Birla, JK Laxmi or equivalent) |
| 18 | M&L for painting walls with two coats of interior plastic emulsion paint over old painted surfaces of any description over 10cm girth or width, not otherwise described including complete removal of old treatmentby rubbing/scraping/washing (make: Nerolac / Berger / Asian paints or euquivalent). |
| 19 | M&L for preparing of old plastered or unplastered surface of ceiling and applying two coats of white wash mixed with blue and gum all as directed on old decorated surface |
| 20 | M&L for preparing of new or previously untreated surface of ceiling and applying two coats of white wash mixed with blue and gum all as directed |
| 21 | Preparation of new plastered surfaces of wall, painting two coats of cement paint over a coat of chalk whiting primer all as directed. Make and shade approved by Engineer In Charge before use in the work. (Make Indigo, snowcem india Ltd or equivalent). |
| 22 | M&L for Providing and fixing Gypsum Board 12mm thick designer/plain ceiling fixed with screw as per manufacturers instructions in directives and approval of EIC (make:- Armstrong,Saint-Gobain,USG Boral or equivalent) (Test certificate to be provided) |
| 23 | M&L for applying 3mm thick wall care putty on ceiling surface of any description (make:- JK super,Aditya Birla,JK Laxmi or equivalent). |
| 24 | M&L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre ,specification of matrial should confirm to MES SSR part-1 |
| 25 | M&L for cutting holes superficial area n exc 150 sqcm into or through brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required |
| 26 | S&F 50mm dia Tubes, \"medium grade\" galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors etc as directed (make: jindal, tata or equivalent) (Test certificate required) |
| 27 | S&F for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165(Test certificate required) |
| 28 | S&F of Hangers 6 mm dia. G.I.(upto 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified or as perMES ssr part-1 specifications |
| 29 | S&F of Anodised aluminium snap grid frame work for false ceiling all as specified with grid size 605*605mm material should be conform to IS 733, IS 737, IS 1285 or as per MES SSR Part-01 2009(make: armstrong, alstrong, aludecor or equivalent) |
| 30 | M&L for providing and fixing of mineral fiber based tiles for false ceiling having minimum thickness 09mm ,suitable for fixing on 605X605 mm snapgrid as directed and approved by EIC (Make:- Armstrong,Aludecor or equivalent) (Test certificate required) |
| 31 | S&F for powder coated Anodised aluminium partition / frame work having minimum weightof section 0.75 KG/ RM including all necessary fittings for fixing like rebates joining cleats,EPDM neoprene rubber packing etc. all using 05 mm thick plain glass /04mm APP sheet having main section thickness is minimum 1.20mm as required and directedspecifications of material should conform to MES SSR Part-1 2009(Test certificate required)( make : - for aluminium sections Hindalco , Jindal, Tataor equivalent andfor ACP sheets Alstrong, Alstone, Eurobond or equivalent). |
| 32 | S&F of powder coated(minimum thickness of powder coating 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips,EPDM ruber neoprene packing,handles 2Nos in each door, hinges, powder coated anodised aluminum snap beading screws etc. complete all as specified and directed (aluminium sections Make:- Hindalco,Jindal, Tata or equivalent) (Test certificate required) |
| 33 | S&F of 5.5mm thick sheet glass, ordinary quality in squareexc 0.5 sq. m in each pane fixing complete with all necessary fittings as directed specification should match to MES ssr part-1 |
| 34 | S&F of 04mm thick aluminum composite panels to any framework with EPDM rubber neoprene packing (Make:- Alstrong, Alstone, Eurobond or equivalent). |
| 35 | S&F of solar control film 25 micron reflective type/designer as approved by EIC sticked to glass panes as per instructions of manufacturers |
| 36 | S&F of 140mm length cover plate floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed (make: godrej, harrison or equivalent). |
| 37 | S&F of 100 mm length bolt aluminium anodised, barrel tower bolts of extruded section (make: godrej, harrison or equivalent). |
| 38 | S&F of 04 Lvr aluminium mortice lock, vertical type, size 75 mm with handles 02no in each (Make:- godrej,link,harrison or equivalent). |
| 39 | S&F of aluminium (extruded section) body door closer hydraulicallyregulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed(Make:- godrej,doorway or equivalent). |
| 40 | Dismantling wrought iron or mild steel work of any description not otherwise provided or as directed including making good of walls after removal of windows/ doors or other ms work as directed |
| 41 | S&F of powder coatedanodised aluminium windows sliding type bombay pattern complete with all required fittings, Locking arrangement etc. including 05mm thick plain sheet glass and aluminium grill in one side of aperture/hole size 50mm X 50mm approx. and 3mm X 9mm wire sizehaving main section thickness minimum 1.20mm oras directed by EIC.(aluminium sections Make:- Hindalco,Jindal,Tata or equivalent). |
| 42 | Taking downChowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frame) and removal to stores |
| 43 | S&F of 1st class hardwood ( Teak Wood ) Plain, solid, straightchowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinnedat joints,suppliedandfixed all material should conform to MES SSR Part-01 specifications |
| 44 | S&F of 40mm Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides face is covered with deco rative face veneer with lipping/frame to matchwith 100 X 900mm , 05mm thick sheet glass strips as per drawing/design attached in directives of EIC |
| 45 | S&F of 40mm thick 1st class hardwood (Teak wood) Plain/designed, framed, panelled shutters (any number of panels), with panels of timber flat/designed on single side (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats (design to be approved by EIC before supply) |
| 46 | M&L for French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats (make : Asian, Berger, Pidilite, Nerolac or equivalent) |
| 47 | S&F of 125 mm Brass handles,cast type,polished bright design as approved by EIC(Make:- Godrej,Link,Harrison or equivalent). |
| 48 | S&F of 250mm bolt length Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed (Make:- Godrej,Link,Harrison or equivalent). |
| 49 | S&F of 200 mm Brass barrel tower bolts, with cast or sheet barreland rolled or cast bolts and fixed (Make:- Godrej,Link,Harrison or equivalent). |
| 50 | S&F of 150mm length cover plate floor door stopper ofbrass body and tongue with hard drawn steel spring , fixed (make: godrej, harrison or equivalent). |
| 51 | M&L for applying two coats of synthetic enamel paint over old wooden surfaces including prepration etc. for surfaces of any description,nototherwise described, over 10cm width or girth (Make:- asian,berger,nerolac or equivalent). |
| 52 | S&F for12 mm thick prelaminated particle boards for repairing etc., interior grade, prelaminated both side with decorative choice lamination, fixed with screws toframe work complete including all necessary fittings to walls etc. colour and design of board should match to existing or approved by EIC (Test certificate is required)(make:- greenply,century,action tesa or equivalent). |
| 53 | Removing building materials etc.to a distance of 500m , beyond the lead included in the rates, including loading, unloading and stacking at the destination whereas directed |
| 54 | S&F of 100mm Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, typeB-11 (Make:- Godrej,Link,Harrisons or equivalent). |
| 55 | M&L for laying cement polymer based adhesive over tiled surface or any other for fixing of vitrified/ceramic tiles in floors etc. as directed by EIC (Test certificate is required)(Make:- Kajaria,Johnson endura, Somany, Asianpaints or equivalent). |
| 56 | M&L for Virified Ceramic dark shade/double charged/ultracharged tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as directed by EIC (Test certificate is required)(make: Kajaria,Jonson,somany or equivalent) |
| 57 | S&F of coloured Glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match of(make Kajaria, Johnson, Somany as approved or equivalent). (Test certificate is required) |
| 58 | Taking down and refixing in same opening for Shutters of any description exc 1 sq m and n exc 2sq.m each after alterations as required |
| 59 | S&F for vitreous china urinals,half stall(back or corner wall type), by replacing existing complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe with grating and union for discharge pipe complete including waste pipe with coupling 32mm,15 mm dia.PVC angle stop valve & PVC connection etc. (Make:- Cera,Parryware,Roca,Jaquar or equivalent). |
| 60 | S&F Vitreous China wash basin, white, flat back,with stand size 630x450mm complete by replacing old existingincluding brackets & accessories as one 15 mm dia.PVC piller tap, 450 mm long 15 mm dia.PVC connection,15 mm dia PVC angle stop valve,32 mm dia CP waste fitting(Make:- Cera,Parryware,Roca,Jaquar or equivalent). |
| 61 | M&L for Point wiring for one light point or fan point controlled by one switch with 1.5sq.mm. stranded copper PVC single core, ISI marked, Make : ANCHOR/POLYCAB /V-Guard or equivalent, sheathed cable drawn in PVC conduit. |
| 62 | M&L for Point wiring for one 3 pin socket outlet 5Amps on the INDEPENDENT BOARD with other switches with cable 2.5 sq.mm ISI marked, Make : ANCHOR/POLYCAB/V-Guard or equivalent, drawn in PVC conduit wiring copper along with earthing. |
| 63 | M&L for Point wiring for one 3 pin socket outlet 15Amps on the INDEPENDENT BOARD with other switches with cable 4 sq.mm, ISI marked, Make : ANCHOR/POLYCAB/V-Guard or equivalent drawn in PVC conduit wiring copper along with earthing. |
| 64 | M&L for Point wiring for one 3 pin socket outlet 5Amps on the same board with other switches with cable 1.5 sq.mm, ISI marked, Make : ANCHOR/POLYCAB/V-Guard or equivalent drawn in PVC/MS conduit wiring copper along with earthing on SAME BOARD |
| 65 | S&F of Modular switch 1 way 16A, 1 module, ISI marked, Make : HAVELLS/ANCHOR/PHILIPS or equivalent |
| 66 | S&F of Modular switch 1 way 6A, 1 module, ISI marked, Make : HAVELLS/ANCHOR/PHILIPS or equivalent |
| 67 | Cutting chasesand pointing in cement mortar I:3 to ends or edges of landing, steps etc. for concealed conduit wiring , Cutting not exceeding 10 cm girth. |
| 68 | Taking down complete point wiring (old wiring) including light, fan, socket, switches, ceiling rose etc. and removing the material to store for keeping in safe custody and making good, disturbed wall, floors etc. |
| 69 | S&Ffor Modular Socket, 6A - 2/3 pin combined 2 module, ISI marked, Make : HAVELLS/ANCHOR/PHILIPS or equivalent. |
| 70 | S&F for Modular Socket 6A/16A - 2/3 pin combined 2 module,ISI marked, Make : HAVELLS/ANCHOR/PHILIPS or equivalent. |
| 71 | S&F Modular Plate White cover plate with frame, 6 moduleISI marked, Make : HAVELLS/ANCHOR/PHILIPS or equivalent. |
| 72 | S&F Modular Plate White cover plate with frame, 3 moduleISI marked, Make : HAVELLS/ANCHOR/PHILIPS or equivalent. |
| 73 | S&F of Modular Bell push 6A 1 moduleISI marked,Make : HAVELLS/ANCHOR/PHILIPS or equivalent. |
| 74 | S&F of Bell, AC, 230 volts, single pole ISI marked,Make : HAVELLS/ANCHOR/PHILIPS or equivalent. |
| 75 | M & L for ceiling rose pvc/policarbonate isolated body.Make Anchor/havells ISI marked |
| 76 | Hanging only ceiling fan (M.D.supply) and connecting up including provision of cable from ceiling rose or connector to fan. |
| 77 | S & F of earth continuty conductor4 mm dia galvanised steel wire including connection with GI nuts, bolts, washers and lugs etc. |
| 78 | S & F of modular Metal flush box 3 module, |
| 79 | S & F of modular Metal flush box 6 module |
| 80 | S& Fof wiring for circuit/submain wiring alongwith earth wire with the 2x2.5 sq. mm + 1x2.5 sq. mm earth wire earth wire of FR PVC insulated copper conductor , single core cable, ISI marked, Make : ANCHOR/POLYCAB/V-Guard or equivalent , in surface/ recessed as required in PVC conduit. |
| 81 | S& Fof wiring for circuit/submain wiring alongwith earth wire with the 2x2.5 sq. mm + 1x2.5 sq. mm earth wire earth wire of FR PVC insulated copper conductor , single core cable, ISI marked, Make : ANCHOR/POLYCAB/V-Guard or equivalent , in surface/ recessed as required in existing surface/ recessed steel/PVC conduct |
| 82 | S& Fof wiring for circuit/submain wiring alongwith earth wire with the 2*4.0 sq. mm + 1*4.0 sq.mm earth wire of FR PVC insulated copper conductor , single core cable, ISI marked, Make : ANCHOR /POLYCAB/V-Guard or equivalent, in surface/ recessed as required in PVC conduit. |
| 83 | S& Fof wiring for circuit/submain wiring alongwith earth wire with the 2*4.0 sq. mm + 1*4.0 sq.mm earth wire of FR PVC insulated copper conductor , single core cable, ISI marked, Make :ANCHOR /POLYCAB/V-Guard or equivalent ,in surface/ recessed as required in existing surface/ recessed steel/PVC conduct |
| 84 | S& Fof wiring for circuit/submain wiring alongwith earth wire with the 2*6.0 sq. mm + 1*6.0 sq.mm earth wire of FR PVC insulated copper conductor , single core cable, ISI marked, Make : ANCHOR /POLYCAB/V-Guard or equivalent ,in surface/ recessed as required in PVC conduit. |
| 85 | S& Fof wiring for circuit/submain wiring alongwith earth wire with the 2*10.0 sq. mm + 1*10.0 sq.mm earth wire of FR PVC insulated copper conductor , single core cable, ISI marked, Make : ANCHOR /POLYCAB/V-Guard or equivalent ,in surface/ recessed as required in PVC conduit. |
| 86 | S& Fof wiring for circuit/submain wiring alongwith earth wire with the 2*16.0 sq. mm + 1*16.0 sq.mm earth wireof FR PVC insulated copper conductor , single core cable, ISI marked, Make : ANCHOR /POLYCAB/V-Guard or equivalent ,in surface/ recessed as required in PVC conduit. |
| 87 | S&F of Fe 410-W(Gde-E- 250) quality-A of MS clamp including fabricationforfixing of Sheet Metal Enclosures with socket plug top & MCB& 4 way SPN DB on Pillers &to be usedClamp made of MS |
| 88 | Dismentling and taking down FTL |
| 89 | Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store ® |
| 90 | M&L for PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm 3.5 core, ISI marked, Make : POLYCAB /FINOLEX /DELTON /HAVELLS/ANCHOR/PARAMOUNT/POLYCAB or equivalent. |
| 91 | M&L for PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq. mm 3.5 core, ISI marked, Make : POLYCAB /FINOLEX /DELTON /HAVELLS/ANCHOR/PARAMOUNT/POLYCAB or equivalent. |
| 92 | Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete, ISI marked, Make : HAVELLS/ANCHOR/BAJAJ or equivalent. |
| 93 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), ISI marked, Make : HAVELLS/USHA/ORIENT/CROMPTON or equivalent. |
| 94 | S & F of Double door Sheet metal enclosure for TPN DB 6-way, 415V, ISI marked,Make : HAGER/SIEMENS/HAVELLS / Schneider/ ANCHOR/ LEGRAND or equivalent. |
| 95 | S & F of Double doorsingle polefor SPN DB 4-way, 240V AC, ISI marked, Make : HAGER/SIEMENS/HAVELLS/ Schneider / ANCHOR/ LEGRAND or equivalent. |
| 96 | S & F of Double doorsingle polefor SPN DB 8-way, 240V AC, ISI marked, Make: HAGER/SIEMENS/HAVELLS /Schneider / ANCHOR/LEGRAND or equivalent. |
| 97 | S & F of Double doorsingle polefor SPN DB 12-way, 240V AC, ISI marked, Make : HAGER/SIEMENS/HAVELLS/ Schneider / ANCHOR/ LEGRAND or equivalent. |
| 98 | S & F ofisolatorDP 40 Amps, 240V, ISI marked, Make : HAGER/SIEMENS/HAVELLS/ ANCHOR/LEGRAND or equivalent. |
| 99 | S & F ofisolatorDP 63 Amps, 240V, ISI marked,Make : HAGER/SIEMENS/HAVELLS/ ANCHOR/LEGRAND or equivalent. |
| 100 | S&F of MCB SPNsingle pole 40A ,240VISI marked,Make : HAGER/SIEMENS/HAVELLS / Schneider/ ANCHOR/ LEGRAND or equivalent. |
| 101 | S & F of MCB TPN100A , 415V, ISI marked, Make : HAGER/ SI EMENS/HAVELLS/ ANCHOR/Schneider / LEGRAND or equivalent. |
| 102 | S & F of MCB TPN 63A, 415V, ISI marked, Make : HAGER/ SIEMENS/HAVELLS/ ANCHOR/Schneider / LEGRAND or equivalent. |
| 103 | S&F of Sheet Metal Enclosures with socket plug top & MCB single Pole & Neutral enclosure with a 2 pin & earth plug & Sccket complete with one single pole MCB, 240V, ISI marked, Make : HAGER/SIEMENS/HAVELLS/ ANCHOR/Schneider / LEGRAND or equivalent. |
| 104 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker(MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning (i) SP 6 To 32 AMP |
| 105 | Taking down all old TPN DB, SPN DB, Switch Boards alongwith all old MS conduit in the work area allotedand during doing this work the genereated holes are to be filled by cement concrete work and making surface clear. |
| 106 | S&F ICTP Switch with ceramic fuse set , 200 A Make : Havells/Standard/C&F/Bajaj/Anchor or equivalent |
| 107 | Ceiling fan hanging MS pipe 15mm with MS clamp |