Improvement and Development of culvert and drains at Qtr. No.13.17.19.69 in R. K. Puram Sec.5 in W.No.152/SZ.-Improvement/Development of culverts and drains by pdg brick work, plaster, RCC items, precast RCC Slab/Gratings fromQtr No.13 to Qtr No.17 and Qtr. No.19 to 69in R. K. Puram Sec-5 in Ward No-152/SZ., DSR DAR CIVIL-2018 and approved items; 1 Culvert and Drains 2 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 3 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 4 110.25.1:Excavation in nalla/drains in running condition including taking out and disposal of excavated silt/sludge/rubbish/earth mixed malba etc. from the drain, culvert and other similar conditions under sumberged/foul condition within 50 metre lead and 1.5 m lift, blocking drain in the required length by placing sand filled bags and pumping out water including removal of stone, brick bats, cloating material etc. before excavation. a) Open nalla 5 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 6 4.1.10A:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 10 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA) ) 7 6.1.2:Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 8 13.4.2:12 mm cement plaster of mix:1:6 ( 1 cement : 6 coarse sand) 9 13.18:Neat cement punning 10 4.1.3A:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand (zone-III) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) upto 25%) 11 5.1.2A:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) incuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size of Recycled Concrete Aggregate (RCA) upto 20% 12 5.9.3A:Centering and shuttering including strutting ,proppingetc.and removal of form for Suspended floors, roofs, landings,balconies and access platform 13 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 14 110.18:Providing and laying compacted bed of dry brick aggregate of 40/50 mm thick nominal size in required thickness including spreading, well ramming, consolidating and grouting with Jamuna sand including finishing smooth etc. complete as per direction of Engineer-in-charge (compacted thickness to be measure for the purpose of payment) 15 16.91.1:Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 16 16.93:Providing and placing in position 100mm thick factory made machine batched & ma chine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes,of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage ,all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge . 17 1.1.1_14:Disposal of materials by mechanical transportincluding loading ,unloading and stacking lime ,moorum, buildingrubbish for lead 14 km