Tender For Provision Of Air Engineering Department/ Air Electrical Department And Advance Light Helicopter Hangar At Cgae (Pbr), Port Blair
Tender Overview
Project Description
Provision Of Air Engineering Department/ Air Electrical Department And Advance Light Helicopter Hangar At Cgae (Pbr), Port Blair Pprovision Of Air Engineering Department/ Air Electrical Department And Advance Light Helicopter Hangar At Cgae (Pbr), Port Blair
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Oct-2024 | CorrigendumNo1 | Other | 05-Nov-2024 |
| 2 | 23-Oct-2024 | CorrigendumNo2 | BOQ | 05-Nov-2024 |
| 3 | 29-Oct-2024 | CorrigendumNo3 | Date | 12-Nov-2024 |
| 4 | 04-Nov-2024 | CorrigendumNo4 | Date | 19-Nov-2024 |
| 5 | 08-Nov-2024 | CorrigendumNo5 | Date | 26-Nov-2024 |
| 6 | 19-Nov-2024 | CorrigendumNo6 | Date | 02-Dec-2024 |
| 7 | 19-Nov-2024 | CorrigendumNo7 | BOQ | 02-Dec-2024 |
| 8 | 20-Nov-2024 | CorrigendumNo8 | Other | 02-Dec-2024 |
| 9 | 27-Nov-2024 | CorrigendumNo9 | Other | 02-Dec-2024 |
| 10 | 02-Dec-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-Dec-2024 |
BOQ
| Sl. No. | Item Description |
| 1 | NOTE:Schedule ‘A’ Part-I is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6. |
| 2 | Schedule \"A\" Part-I (a) PEB HANGAR : Analysis, design, detailing and supply of detailed Architectural & Structural drawings, and construction of Hangar of PEB structure of size 45mx45m, of 12.5m minimum clear height from the bottom most part of the roof beam girder to FFL on either side. At centre height increases to achieve roof of 1 in 10 including Annexe (Admin/Tech Accn) on both sides of PEB Hangar in double / triple storey (all dimensions as per Architectural drawings), all as specified and as under:-(i) Pre Engineered Building Steel structure for Hangar of size 45mx45m and height as specified herein-before placed in between two annexes on RCC foundation (using RMC) based on soil investigation Report, anchor bolts, base plates and all structural steel items, rain water eaves-gutters and down take pipes, cable ducts, bird proofing of Aluminium alloy wire cloth net fixed with aluminium snap grid framework, etc., with electrically operated sliding doors (on front side of Hangar) with steel frame, etc, with Alu-Zinc colour coated profiled steel roofing sheets 0.5mm thick (TCT) and yield strength of 550 MPa in wall cladding and roofing (maximum of 15% roof / wall sheeting with semi transparent triple layer polycarbonate sheets of thickness 6mm), with synthetic fibres (only virgin) synthetic, monofilament polyster fibres cut length 12mm to 18mm, inert to concrete environment shall be used as a secondary reinforcement in cement based matrix and no recycled material shall be permitted. Excluding as per schedule \"A\" part-III and item No. 24 to 28 of this BoQ in hangar flooring but including epoxy flooring for entire hanger flooring area complete all as specified and as shown on drawings. |
| 3 | The rate includes the provisions of the following :-(a)Provision of necessary base plates including anchor bolts shall be deemed to be included in the unit rate. (b)Wall cladding on the building shall be provided as per drawings. Suitable eaves gutters and rainwater down take pipes as required shall be provided to divert rain water from the Hangar Roof to ground level.(c)Provision of Aluminium frame for fixing of bird proofing is required in hangar complete all as shown on drawings and specified. Rate shall be deemed to be included in the unit rate.(d)The rate is deemed to include the cost of design, fabricate and erect electrically operated (with manual option) sliding Hangar doors at frontside of Hangar. The rate is deemed to include the cost of providing one wicket door of size( 2.00 x 1.00) Mtr in one leaf of hangar door. The Electrical motors alongwith panel and connected items will be paid separately against the BOQ item No.61. The cost of rails above, below the hanger door, pulleys, rollers are deemed to be inclusive of quoted rates.(e)The design has to be done by standard software of latest version. The rate shall be deemed to include the cost of vetting of design of all structures (PEB hangar, RCC foundation as recommended, Structural design of Annexes) by IITs/IISc Bangalore/SERCs. The design (showing full design calculationsand details of complete STAAD soft and hard files in both format) and drawings duly vetted by IITs/IISc Bangalore/SERCs shall be submitted to the department as per time schedule communicated by the GE and as specified.(f) The RCC structure should be design as per IS-456 (2000) and IS-1893 (2002). Ductile detailing shall comply with provns as per IS-13920 and all relevant provn of seismic Zone-V area(g)Certificate from the vetting agency that the design is meeting all relevant codal requirments and design of building is structurally sound shall be furnished. |
| 4 | (h)All drawing for structural drawing, PEB structure incl the details of expansion joint, if any, details of structural members, junction, structural plans, sections required for execution of works etc shall be furnished in original tracing along with soft copy in CD and 5 Sets of Hard copy.(j)Details of quantities of following items shall be furnished :-(i) Steel - Section wise(ii) RCC - (Grade and location wise)(k) Surface and sub-surface drainage to be provided for Hangar floor to ensure the highest level of water tabel remains at least one meter below the bottom of subgrade in consultation by and duly vetted by IITs/IISc Bangalore/SERCs etc as approved under MES policies and regulations. Section 309 MORTH specification 2013.(l) Necessary foundation for the PEB structure and Annexes shall be followed as per Sch \"A\" notes.(m) Necessary excavation for the foundation.(n) Aggregates shall be used as specified under the respective schedules/PS. No extra claims whatsoever on this account shall be admissible.(o) ATT treatment under foundation of PEB hangar and side annexe including floors and plinth protection.(p) EOT crane is integral part of the Hangar and shall be measured and paid separately under BoQ srl item No 61 hereinafter. However, necessary PEB structural (substructure and superstructure) arrangement to fix the EoT crane shall be deemed to be included.(q) Any items which are essential and required to complete the Pre-Engineered Building for Hangar of size 45mx45m and height as specified herein-before including side annexes (Admin/Tech accn) and not found mentioned hereinbefore/after shall be deemed to be included in quoted rate. Nothing extra whatsoever shall be admissible.(r) The rate is deemed to include the cost of epoxy flooring 5mm thick (Epoxy Quartz screed 4mm thick plus top self levelling floor 1mm thick) including lines, dashes, arrows, numbering etc, in entire floor area of hangar. |
| 5 | (b) Admin/Tech accn for Hangar Annexes : Analysis, design, detailing and supply of detailing and supply of detailed Architectural and Structural drawings, (including constn of Annexexes (Admin/Tech Accn) on either side of Hangar (Dimension as per line plan) in double storey and triple as permanent structure with RCC framed construction. Internal Electrification, Internal Water supply etc complete all as specified and as shown on drawings.(i)Stilt Floor (Parking Area)(ii) Annex Bldg except Still Area (Double Storeyon one side and Triple Storey onother side)(iii) Reinforcement cement concrete of grade M-30 design mix water tank of 22000 ltrs capacity with partition wall for fire fighting and domestic purpose on both annexe each. The capacity of tank will be divided in two parts one of 20,000 ltrs for fire fighting and 2,000 ltrs for domestic purpose. There will be provn of over flow filling of domestic portion to keep fire fighting part always full of water. Total height should be within permissible limit of height of building. The rate includes the provisions of the following :-(i)Necessary foundation for the PEB structure and Annexes shall be followed as per Sch \"A\" notes.(ii)Necessary excavtion for the foundation.(iii) All types of joinery, building hardware and other items which are essential and required to complete the building in all respect as specified |
| 6 | GENERAL SUMMARYNOTE: Schedule ‘A’ Part - IA, II to XVIII are prepriced by MES under Ser No. 4.00to 21.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 7 | Lumpsum price worked out by the contractor for “BUILDINGS / STRUCTURES” as listed in Schedule ‘A’ Part - IA , inserted by MES |
| 8 | Lumpsum price worked out by the tenderer for \"EXCAVATION & EARTHWORK INCLUDING SITE CLEARANCE AND LAND DEVELOPMENT\" as listed in Schedule ‘A’ Part- II |
| 9 | Lumpsum price worked out by the tenderer for \"HANGAR FLOORING \" as listed in Schedule ‘A’ Part- IIINote :Main land aggregates shall be used. No extra claims whatsoever on this account shall be admissible. |
| 10 | Lumpsum price worked out by the tenderer for \"INTERNAL WATER SUPPLY \" as listed in Schedule ‘A’ Part-IV |
| 11 | Lumpsum price worked out by the tenderer for \"INTERNAL ELECTRIC SUPPLY\" as listed in Schedule ‘A’ Part- V |
| 12 | Lumpsum price worked out by the tenderer for\"ROADS AND HARD STANDING \" as listed in Schedule ‘A’ Part- VI |
| 13 | Lumpsum price worked out by the tenderer for \"SEWAGE DISPOSAL\" as listed in Schedule ‘A’ Part- VII |
| 14 | Lumpsum price worked out by the tenderer for \"AREA DRAINAGE\" as listed in Schedule ‘A’ Part- VIII |
| 15 | Lumpsum price worked out by the tenderer for \"EXTERNAL WATER SUPPLY\" as listed in Schedule ‘A’ Part- IX |
| 16 | Lumpsum price worked out by the tenderer for \"EXTERNAL ELECTRIC SUPPLY\" as listed in Schedule ‘A’ Part- X |
| 17 | Lumpsum price worked out by the tenderer for \"AIR CIRCULATOR & TURBO VENTILATOR\" as listed in Schedule ‘A’ Part-XI |
| 18 | Lumpsum price worked out by the tenderer for \"Hangar LIGHT\" as listed in Schedule ‘A’ Part-XII |
| 19 | Lumpsum price worked out by the tenderer for \"FIRE FIGHTING SYSTEM\" as listed in Schedule ‘A’ Part- XIII |
| 20 | Lumpsum price worked out by the tenderer for \"FIRE ALARM SYSTEM \" as listed in Schedule ‘A’ Part- XIV |
| 21 | Lumpsum price worked out by the tenderer for \"LIGHTENING PROTECTION\" as listed in Schedule ‘A’ Part- XV |
| 22 | Lumpsum price worked out by the tenderer for \"AIR CONDITIONING\" as listed in Schedule ‘A’ Part-XVI |
| 23 | Lumpsum price worked out by the tenderer for \"COOLING APPLIANCES\" as listed in Schedule ‘A’ Part-XVII |
| 24 | Lumpsum price worked out by the tenderer for \"TELEPHONE CONDUIT\" as listed in Schedule ‘A’ Part- XVIII |
| 25 | Subtotal |
| 26 | NOTE:Schedule ‘A’ Part - XIX \"MICELLANEOUSITEMS\" is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6. |
| 27 | HANGAR FLOORINGM&L for 125mm thick dry lean concrete (DLC), M-15 design mix with min cement content 180kg/cum, laidalternate bay using concrete paver including necessary use and removal of steel side formwork, finish rough. complete all as specified and as directed. Note : Main land aggregates shall be used. No extra claims whatsoever on this account shall be admissible. |
| 28 | M&L for 200MM thick pavement quality cocrete work in pavement of flexural strength 45Kg/Sqcm (lower control limit) in field as per mix design with min 400Kg of cement/cum with 20mm nominal size of graded aggregate and super palstiscizer if required as per design mix (As per IRC 5th revision) mixed with and including triangular/non circular synthetic fibre reinforcement @ 0.25% by weight of cement with min 12mm length, specified gravity 1.34 to 1.40 ( specification all as per IRC/MORTH ) spread and compacted by using slip from paver and all as specified and including necessary formwork, bull nosing, rounding of edges finishing by mechanical brooming/belting, curing etc, complete all as specified and as directed.Notes:(i) Forming construction joints, dummy (contraction) joints and expansion joints shall be measured and paid separately under respective items.(ii) Deduction shall be made in computing concrete quantity for expansion joints as per SSR preamble.(iii) Synthetic fibre and plasticizer are to be measured and paid separately under respective items.(iv) Belting are to be measured and paid separately.(v) initial curing compound of approved make shall be sprayed and cost of the same is deemed to be included in quoted rate.(vi) Expansion joint, contraction joint and dummy joint shall be provided as per drg No. CE/WD/S/2023/01, Sheet No. 1/1 anddated 18 dec 2023.(vii) Plasticizer of approved quality, mixed in cement concrete in accordance with design mix requirements. Rate shall be deemed to be included in the unit rate. |
| 29 | M&L for forming 25mm wide expansion joint filled with compressible synthetic filler board for complete depth of joint, i.e. the thickness of slab, provision of closed shall back up rod 30mm dia, filled with polyurethane sealant (min depth of sealant above back up rod shall be of 15mm), complying with BS 5212, BS 4254, and EN 41875-2003, priming the sides min MAF ± 30% with 10 years performance guarantee and applying masking tape on edge of joints to prevent accidental spillage of sealant on top surface to give neat finish to sealant and removing the masking tape after sealant is applied by mechanically all as shown on drawing on all as specified. |
| 30 | M&L for formingdummy joint 1/3 depth of slab and 8mm wide (using diamond cutter) providing polythene back up rod 10mm dia and sealed with polyurethane sealant (min depth of sealant 15mm), complying with BS 5212, BS 4254, and EN 41875-2003, priming the sides min MAF ± 30% with 10 years performance guarantee and applying masking tape on edge of joints to prevent accidental spillage of sealant on top surface to give neat finish to sealant and removing the masking tape after sealant is applied by mechanically all as shown on drawing on all as specified. |
| 31 | M&L for formingconstruction joints 25mm deep and 10mm wide (using diamond cutter) providing polythene back up rod 12mm dia and sealed with polyurethane sealant (min depth of sealant 15mm), complying with BS 5212, BS 4254, and EN 41875-2003, priming the sides min MAF ± 30% with 10 years performance guarantee and applying masking tape on edge of joints to prevent accidental spillage of sealant on top surface to give neat finish to sealant and removing the masking tape after sealant is applied by mechanically all as shown on drawing on all as specified. |
| 32 | INTERNAL ELECTRIC SUPPLYS&F wall mounted fan 400mm sweep, 230 Volt, 50Hz complete all as specified and as directed. |
| 33 | S&F LED Panel Luminaire 600mm x 600mm 24W, 220V AC Recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED Lamps suitable for false ceiling including connecting up with driver 3 core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 34 | S&F LED Batton light fitting mirror type with high out put diffuser 2 feet/ 1 feet, 9 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 35 | S&F Vertical TPN DB with MCCB incomer conforming as per IS 8623, IEC 61439-1&3 sheet steel factory made double door, powder coated and bus bar 200Amps copper bus bar fully insulated busbar IP 43, Neutral link, Earth bar, double door type TPN 4 way 415Volt, suitable for MCCB 63Amps as incomercomplete all as specified and as directed. |
| 36 | S&F Vertical TPN DB with MCCB incomer conforming as per IS 8623, IEC 61439-1&3 sheet steel factory made double door, powder coated and bus bar 200Amps copper bus bar fully insulated busbar IP 54, Neutral link, Earth bar, double door type TPN 4 way 415Volt, suitable for MCCB 63Amps as incomercomplete all as specified and as directed. |
| 37 | SEWAGE DISPOSALM&L for 150mm dia CI pipe (sand cast) in any length with (or) without ear laid in trenches and jointed in CM 1:1 complete all as specified and as directed. |
| 38 | EXTERNAL ELECTRIC SUPPLYSupply, install, test, commissioning of outdoor cubical typeLT panel dust andvermin proof, made out of 3.15 mm thick CRCA sheet and 50 x 50 x 5mm angle iron frame duly powder coated. The F.P. box shall be suitable for 3 phase 4 wire system, 440 Volts, 50 Hz duly prewiredfor MCCB\"s and single core PVC insulated multi-stranded copper conductor 1100 volts grade of suitable size for comprising of following items :- (Main LT Panel - Incoming from CGAIS Work):-(a) MCCB 4 Pole,250 Amp , 415 Volts, 50 Hz,25 KA (02No) (01- Incomer, 01- to AMF Panel ) (b) MCCB 3 Pole, 125 Amp , 415 Volts, 50 Hz,16 KA - 02 Nos (Out goingRH main supply Panel & Fire pump panel). (c) MCCB, 3 Pole, 100 Amp , 415 Volts, 50 Hz,25 KA - 1 No (Out Going L H main supply Panel)(d) MCCB, 3 Pole, 63 Amp , 415 Volts, 50 Hz,16 KA - 1 No (Spare)(e) MCB, TPN, 20Amp , 415 Volts, 50 Hz,10 KA - 2 No (Spare)(f) MCB, SPN, 16 Amp , 415 Volts, 50 Hz, 10 KA - 2 No (g) AluminiumBus bar - 1 Set(h) R Y B Indicators - 1 SetNote: The panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above embeded in ground, computer cut self-adhesive vinyl danger notice plate having conventional symbol of bone and skull be provided. |
| 39 | Supply, install, test, commissioning of indoor cubical typeLT panel dust andvermin proof, made out of 2 mm thick CRCA sheet and 40 x 40 x 5mm angle iron frame duly powder coated. The F.P. box shall be suitable for 3 phase 4 wire system, 440 Volts, 50 Hz duly prewiredfor MCCB\"s and single core PVC insulated multi-stranded copper conductor 1100 volts grade of suitable size for comprising of following items :-(LH Side Main Supply Panel - Incoming from Main LT Panel)(a)MCCB 4 Pole,100 Amp , 415 Volts, 50 Hz,16 KA - 01 No (Incomer) (b)MCCB 3 Pole,63 Amp , 415 Volts, 50 Hz,16 KA - 02 No (Out Going for crane, Spare) (c)MCB, TPN Pole, 40 Amp , 415 Volts, 50 Hz, 10 KA -05 No (VTPN DBs at each foolr, Hangar Door Motor Panel)(d) MCB, SPN, 20 Amp , 415 Volts, 50 Hz, breaking capacity 10 KA - 2 No (e) AluminiumBus bar,Volt meter, Ammeter,(f) Indicating lights R, Y, B andSelector switches - 01 Set.Note: The panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above embeded in ground, computer cut self-adhesive vinyl danger notice plate having conventional symbol of bone and skull be provided. |
| 40 | Supply, install, test, commissioning of indoor cubical typeLT panel dust andvermin proof, made out of 2 mm thick CRCA sheet and 40 x 40 x 5mm angle iron frame duly powder coated. The F.P. box shall be suitable for 3 phase 4 wire system, 440 Volts, 50 Hz duly prewiredfor MCCB\"s and single core PVC insulated multi-stranded copper conductor 1100 volts grade of suitable size for comprising of following items :- (RH Side Main Supply Panel - Incoming from Main LT Panel)(a) MCCB 4 Pole,125 Amp , 415 Volts, 50 Hz,16 KA - 01 No (Incomer) (b)MCCB 3 Pole,63 Amp , 415 Volts, 50 Hz,16 KA - 02 No (Out Going RH Wing DB) (c) MCCB 3 Pole,40 Amp , 415 Volts, 50 Hz,16 KA - 01 No (Spare) (c) MCB, TPN , 63 Amp , 415 Volts, 50 Hz, 10 KA -05 No (VTPN DBs at each floor, Hangar Door Motor Panel)(e) MCB, SPN, 20 Amp , 415 Volts, 50 Hz, breaking capacity 10 KA - 2 No (e) AluminiumBus bar,Volt meter, Ammeter,(f) Indicating lights R, Y, B andSelector switches - 01 Set.Note: The panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above embeded in ground, computer cut self-adhesive vinyl danger notice plate having conventional symbol of bone and skull be provided. |
| 41 | Supply, install, test, commissioning of indoor cubical typeLT panel dust andvermin proof, made out of 2 mm thick CRCA sheet and 40 x 40 x 5mm angle iron frame duly powder coated. The F.P. box shall be suitable for 3 phase 4 wire system, 440 Volts, 50 Hz duly prewiredfor MCCB\"s and single core PVC insulated multi-stranded copper conductor 1100 volts grade of suitable size for comprising of following items :-(RH Side DG Supply Panel - Incoming from DG AMF Panel) (a) MCCB 4 Pole,160 Amp , 415 Volts, 50 Hz,16 KA - 01 No (Incomer) (b) MCCB 3 Pole,63 Amp , 415 Volts, 50 Hz,16 KA - 01 No (For LH Wing DG supply Panel) (c) MCCB 3 Pole,40 Amp , 415 Volts, 50 Hz,16 KA - 05 No (For RH Wing DB, Terrace Pump) (d) MCB, TPN Pole, 25 Amp , 415 Volts, 50 Hz, 10 KA -01 No (e) MCB, SPN, 20 Amp , 415 Volts, 50 Hz, 10 KA - 2 No(f) AluminiumBus bar,(g) R, Y, B Indicator - 01 SetNote: The panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above embeded in ground, computer cut self-adhesive vinyl danger notice plate having conventional symbol of bone and skull be provided. |
| 42 | Supply, install, test, commissioning of indoor cubical typeLT panel dust andvermin proof, made out of 2 mm thick CRCA sheet and 40x40x5mm angle iron frame duly powder coated. The F.P. box shall be suitable for 3 phase 4 wire system, 440 Volts, 50 Hz duly prewiredfor MCCB\"s and single core PVC insulated multi-stranded copper conductor 1100 volts grade of suitable size for comprising of following items :-(LH Side DG Supply Panel - Incoming from RH Side DG Supply Panel)(a) MCCB 4 Pole,160 Amp , 415 Volts, 50 Hz,25 KA - 01 No (Incomer) (b) MCCB 3 Pole,100 Amp , 415 Volts, 50 Hz,16 KA - 01 No (For LH WingSecond Floor) (c) MCCB 3 Pole,63 Amp , 415 Volts, 50 Hz,16 KA - 3 No (LH Wing First & spare)(d) MCCB, 3 Pole, 40 Amp , 415 Volts, 50 Hz, 16 KA -01 No (terrace Pump) (e) MCB, SPN, 20 Amp , 415 Volts, 50 Hz, 10 KA - 2 No(f) AluminiumBus bar,(g) R, Y, B Indicator - 1 SetNote: The panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above embeded in ground, computer cut self-adhesive vinyl danger notice plate having conventional symbol of bone and skull be provided. |
| 43 | Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, including provision of GI earth strip 32x6 mm as earthing lead connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, provision of40mm dia GI pipe medium grade for GI strip protection connected from earth plate electrode to main switch board, provision of 20mm dia GI pipe medium grade for watering arrangement and PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, 50mm thick RCC 1:2:4 type B1 for earth pit cover with 6 Nos x8 mm dia high strengthdeformed steel TMT bars on both ways, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc. 50m, provision of charcoal and salt complete all as shown in electrical plate No.3 of Schedule Part-I 2009 all as specified and as directed. |
| 44 | AIR CIRCULATOR & TURBO VENTILATORSupply and fix air circulator fan 230 Volt single phase oscillating 450 mm sweep, 1440 RPM suitable for wall mounting complete all as specified of make Havells Cat No : FHACWSTSCL 18 or equivallent in crompton, Bajaj. |
| 45 | Supply and fix roof mounted Turbo Ventilator 600 mm sweep, including metal base plate with SS variable duct suitable for roof mounting. completed all as specified and directed. |
| 46 | Hangar LIGHT Supply & fix LED High bay light fitting of 130 W, PDC housing, toughened & shattered proof glass with fixing of bolts, nuts or screws as per the manufactures specifications on the roof cannels/ beams etc of Philips Cat No BY325P LED130S CW PSU GR FG NBxTFCL V1 or equivallent in Bajaj, Havells, Crompton, Wipro |
| 47 | S & F MCB SP 10 A 240 V, C-Curve complete all as specified and as directed. |
| 48 | S & F MCB SPN 40A 230 V, C-Curve complete all as specified and as directed. |
| 49 | FIRE FIGHTING SYSTEMSupply & Fix brass branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090 complete all as specified and as directed. |
| 50 | S & F fire Hydrant stand post of 63mm dia, suitable hight from the ground level as per the site requirement with provn of single outlet conforming to IS 908 complete all as specified and as directed. |
| 51 | Supply and fix Foot Valve conforming to IS 4038, 50 mm dia (JockeyPump -1) complete all as specified and as directed. |
| 52 | Supply and fix reflux Valve, with by-pass Arrangement, 100 mm dia (Diesel Pump-1,Electric Driven Prump-01) complete all as specified and as directed. |
| 53 | Supply & fix valve, reflux, with by-pass arrangements, 50 mm ( JockeyPump& PrimingPump) Valve complete all as specified and as directed. |
| 54 | Supply & fix valve, reflux, with by-pass arrangements, 150mm dia (6\") ( Diesel Pump-01, Electric Pump - 1) complete all as specified and as directed. |
| 55 | Supply, installation, testing and commissioning outdoor cubical feeder pillar box suitable for 3 phase, 4 wire, 415 volts to 50Hz supply system with suitable size free working space for maintenance and powder coating provided with suitable to make it dust/vermin proof. The panel shall be made with 3.15 mm thick CRCA sheet for outer shell and inner shell made out of 2mm thick CRCA sheet, double door with front and back openable with locking arrangement, provision of threaded earthing stud at bottom, inner shell completely vermin proof and to accommodate incoming / outgoing MCCB, MCBs and TPN aluminum bus and extension links of rating not less than 1.5 times the rated capacity of the respective MCCBs. The TPN busbar and extensions link shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on epoxy regin insulator. All control wires shall be with 2.5 sqmm multistandad copper conductor wire and shall be properly bunched, tied ferruled for proper identification and crimped with adequate size of lugs. The panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground level and 45cm embedded in ground, computer cut self adhesive vinyl danger notice plate having conventional symbol of bone and skull be provided. The panel shall be consist of the following accessories:- i)Busbar Aluminium TPN 400 Amps -1 Setii) MCCB FP 125 Amps 35 KA - 01 Nos (Incomer)iii) MCCB TP 125 Amps 25 KA - 01 Nos (Main Fire Pump)iv) MCCB TP 40 Amps - 01 Nos (jockey)v) Star Delta Starter for 75 HP Pump - 01 Nosvi)Star Delta Starter for 12.5 HP Pump - 01 Nos vii) Indicating Lamps LED Type-03 Nosviii) Battery Charger for Diesel pump - 1 Noix) Control circuit for automatic operation of Electric, Diesel & Jockey Pump - 1 Set |
| 56 | Supply and fix Automatic air release valve 50mm dia suitable for domestic water with 50mm gun metal stop valvecomplete all as specified and as directed. |
| 57 | FIRE ALARM SYSTEMSupply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded copper conductor of size 1.5 Sqmm 2 Corecomplete all as specified and as directed. |
| 58 | AIR CONDITIONINGSupply and install voltage stabilizer for automatic operation ,single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilizer at 230V with accuracy of +2.5% and capacity 4 KVA.complete all as specified and as directed. |
| 59 | Supply and install voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilizer at 230V with accuracy of +2.5% and capacity 5 KVA.complete all as specified and as directed. |
| 60 | COOLING APPLIANCESSupply and install voltage stabilizer for automatic operation ,single phase naturally air cooled indoor type & designed for input variation between 150V to 280V with output voltage stabilizer at 230V with accuracy of +2.5% and capacity 1KVAcomplete all as specified and as directed. |
| 61 | HANGAR DOOR MOTORS&F electric motor 3 phase ,440 Volts, 50Hz of capacity not less than 3 HP with gear box, chain & sprocketdriving system for opening & closing (forward & reverse motion) suitable for Hangar motorised door and baffle plate to drag following door, including door limit switches, cable from starter panel to motor complete with suitable size DOL starter with LT Panel/ switch , LT copper cable of suitable size etc. - one each side complete all as specified and as directed by Engineer -in Charge. Notes:(i)Approx dimensions of Hangar door 22.5mtr x 10mtr(ii)Operating mechanism including specifications of motor, gear box, pulleys etc. shall be designed by the contractor and get approved from department by Engineer-in-Charge before installation. |
| 62 | OBSTRUCTION LIGHTSupply and Fix aviation obstruction light LED type, 12 W diecast aluminium with red coloured ploy carbonate doomincluding mounting brackets and providing 3 core 1.5 sqmm wire in PVC conduit from light fitting to Socket/Switch box complete of Baja Cat No: BGAV 302 LED or equivallent havells, crompton, Philips complete all as specified and as directed. |
| 63 | HANGAR CRANEDesign, supply, install, testing and commissioning crane of capacity 3 tons, double girder, electrically operated OH complete with working span of 45 Mtr spanning from edge to edge (inner) of Hangar walls, and crane moves longitudinally along the length of Hangar 45 mtr, Hook height of the crane 8.5 Mtr from FFL & cross travel of the crane moves along the width of the hanger (45mtrs) complete all as specified and directed.(Technical specifications attached as Appx \"EC\")Make of Cranes: M/s Safex Energy Pvt Ltd, M/s Pioneer Cranes Elevators Pvt Ltd, M/s Dinesh Enterprises, M/s Tojym Steel ProductsNote: (i) The cost of the gantry girder and rail for the crane movement shall be deemed to be included in quoted rate.(ii) Design drawings of structural, electrical & mechanical components of crane specifications of components (motors, switchgear, controls etc.) of crane, design calculations etc. prepared by OEM shall be got approved by the accepting officer before installation of crane. |
| 64 | STAND BY POWER SUPPLYSupply, install, testing and commissioning of approved OEM factory assembled diesel generator set of totally enclosed and sound proof (with acoustic enclosure) of capacity 160 KVA, 3 phase, 4 wire, 415 volts, 1500 RPM, AC power supply with power factor 0.8, coupled directly to alternator mounted on common base plate complete with fuel tank, battery and standard accessories and fittings, vibration pads, PCC foundation complete all as specified and directed. The genset shall conform to CPCB norms for noise and emission limits and including the following : (a) Alternator :- Standard design alternator rated at 160 KVA net output at site after considering all derating factors, site conditions and at power factor 0.8, AC 3 phase, 4 wire 415 volts, 50 cycles, 1500 RPM, self excited, self regulated, screen protected, drip proof IP-23 enclosure, brushless design, insulating class H,voltage regulation +/- 1% operated voltage from no load to full load and shall be in position to generate supply with frequency regulation within +/- 3% tolerance, revolving field type.(b) DIESEL ENGINE: Adequate capacity diesel engine suitable to above alternator, radiator water cooled, to drive independently above alternator and after considering derating as per site conditions directly coupled to alternatormulticylinder, multistroke, direct injection, cold starting, 1500 RPM,with an overload cap of 10% for 1 hour and in any load for 12 hours continuous running complete with standard accessories all as specified and required for safe running and operation with accessories shall be as under:- (i) Flywheel(ii) Air cleaner wet/dry type |
| 65 | (iii) fuel Filter(iv) Fuel Injection system incl.injection pump, solenoid switch, nozzle as per manufacturer\"s specifications (v) Lubricating oil filter (vi) Lubricating oil pump(vii) Turbocharger(viii) Radiator(ix) 24 volts starting system consisting of batteries of capacity as recommended by manufacturer, battery connections with copper leads and with lugs of adequate size, initial charging of batteries, battery charger/ generator with regulator, starter motor, starter gear (x) Extension ofexhaust silencer complete with exhaust pipe of suitable dia from out side canopy to out side of bldg/shedall covered with glass wool wrapped with aluminium foil of 28 SWG adequate to create draft for safe exhaust without transferring vibrations to buildings / walls, flexible exhaust pipe complete.(xi) Microprocessor control electronic metering and module for indication of battery voltage, oil pressure, engine RPM, hour meter and protection against low oil pressure and over speed of engine including electronic governing.(xii) Battery charging system with suitable capacity battery charger complete with necessary connecting leads etc all as directed(xiii) Radiator cooling system comprising of radiator, radiator fan belt. |
| 66 | (xiv) Fuel hoses. (xv) In Built Fuel tankof 10 hours run on full load capacity of DG set(xvi) Air intake system(xvii) Common base frame of sturdy design suitable for antivibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions. (c) CONTROL PANEL :- CRCA Steel fabricated indoor type for controlling the above generating set. The control panel shall consisting of the following components:-(i) MCCB Four Pole 250 Volts, 35 KA of rated capacityas per OEM- 1 No(ii) Set of indicating lamps - 03 No (Load ON DG/Mains& Set Running)(iii) Set of instrument fuses- 01 Set, (iv) Set of current transformers- 01 Set (d) AMF Panel:-Control cubical fabricated from3.15 MM thick CRCA Sheet duly pretreated & powder coated finishwith iron angle base frame Support floor mounted with removable gland plates, hinged front & back openable door with locking arrangement and provision for connecting incoming and outgoing cable leads and the following accessories :(i) Copper bus, bar, 3 phase, 4 wire,400 Amps- 01 Set |
| 67 | (ii) AMF Controller including electrical wiring, Control MCB, Fuses etc- 1 Set(iii) MCCB 250 Amps, Four Pole, 35 KA, 415 Volts - 2 Nos (Mains Supply, DG Supply & Load)(iv)MCCB 160 Amps, Four Pole, 35 KA, 415 Volts - 2 Nos (Load RHS & LHS of Hangars) (v) Power contactor 4 pole 250 Amps - 03 Nos (Mains Supply & DG Supply and Spare)(vi) Auto Manual Selector Switch with wiring - 1 Set(vii) DG set ON/OFF Push Button - 1 Set(viii) Control ON/OFF Selector Switch - 1 No(ix) AC / DC relay & timers (x) O/L relay (xi) CTs Set of 3 - 1 Set(xii) Load on DG Indicator - 1 No(xiii) Load on Mains Indicator - 1 No(xiv) Mains ON Indicator - 1 No(xv) DG ON Indicator - 1 No(xvi) Digital VAFPAF meter : 01 Nos (xvii)Supply and lay Control cable LT 1100 Volt PVC insulated armoured heavy duty copper conductor of suitable size multicore from DG Set to AMF panel(xviii) Any other components/parts as per manufacturer instructions and as directed by GE required for entire completion of the item. |
| 68 | (e) Acoustic Enclosure:- Composite type made of CRCA sheet and structural/sheet metal base frame duly painted with air inlet louvers, including noise absorbent and fire-retardant grade acoustic insulation material, including removable gland plate at lower level of canopy for cable cable entry. Notes:-(i) Necessary PCC foundation as per manufacturer recommendations is deemed to be included in the quoted rate.(ii) The drg and specifications of the DG set & AMF Panel shall be got approved by the contractor from the accepting officer before procurement.(iii) The DG set after installation shallbe got tested at site by the rep nominated by the Accepting Officer and the records of the testing shall be signed by the rep of accepting officer, GE, Engr-in-Charge and the Contractor. (iv) Diesel, grease, engine oil, load bank and testing equipment\"s required for testing shall be provided by the contractor and cost of the same shall be deemed to be included in the contractor\"s quoted rates. |
| 69 | Subtotal |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-6 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-7 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-8 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-9 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-10 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender