Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #45520026

Tender For Repair/Replacement Of Street Lights Poles Automatic Switches Connection, Cables Allied Works At Phase Ii Chindit Top Tenga Ledge Goc Camp Area Of Age E/M Under Ge Tenga

Issued by Statutory Bodies & Commissions/Committees · Tenga Valley, Arunachal Pradesh
Tender Value
45 Lakhs
Estimated cost
Bid Submission
22 Oct 2024
0 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tenga Valley → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Repair/Replacement Of Street Lights Poles Automatic Switches Connection, Cables Allied Works At Phase Ii Chindit Top Tenga Ledge Goc Camp Area Of Age E/M Under Ge Tenga

BOQ

Nature of Work: REPAIR/REPLACEMENT OF STREET LIGHTS, POLES, AUTOMATIC SWITCHES, CONNECTION, CABLES & ALLIED WORKS AT PHASE II (CHINDIT TOP, TENGA LEDGE, GOC CAMP AREA) OF AGE E/M UNDER GE TENGA.
Sl. No. Item Description
1Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 16 sqmm 4 core including taking down of old unserviceable UG cable/service wires.
2Description all as per item No 01 above but of size 16 Sqmm 2 core
3Supply and laying galvanised tube light gradeISI marked of size 40 mm dia incl all fittingsin trenches/fixed on pole/wall/floor or laid in positioncomplete all as specified and directed.
4S&F in replacement kiosk box for luminaires ,weather proof made out of HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded andcover with hinged door, pole mounting type comprising of four pole copper connectors of 16 Amps capacitywith 6 Amp MCB single pole , of minimum size 300x200x105mm,fixed on pole with MS, clamps 30 x 5mm with necessary nuts, washer and incl applying two coats of synthetic enamel paint over ared oxide primer on steel surface/clamps complete all as directed. . Make- Sintex/Supreme/Hensal
5S & F in replacement of GI brackets for fixing LED street light fitting fabricated out of GI tubing 32 mm dia, medium grade,1.2 mtr long , bend to 120 degree shape by cutting, welding and well finishing including MS clamp of flat iron of size 32 x 4 mm -02 Nos complete for steel polesas per site requirement with nut, bolt & washers for fixing of GI bracket complete all as specified and directed.
6M&L for replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 35 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable street light any type/any capacity as specified and directed.
7Description all as per item No 06 above but of capacity 60 Watt
8Description all as per item No 06 above but of capacity 90 Watt
9M&L for replacement of new generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 70 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable street light any type/any capacityall as specified and directed.
10Description all as per item No 09 above but of capacity 200 Watt
11S&F in replacement of battery 12 volt lead acid suitable for solar street light having capacity 150 AH including all fitting arrangements all as specified & directed. Make:- Exide/Amaron/Luminous
12S&F in replacement of battery 12 volt lead acid suitable for solar street light having capacity 120 AH including all fitting arrangements all as specified & directed. Make:- Exide/Amaron/Luminous
13Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP-31) 9 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided withtwo coats of aluminium paint overone coat of red oxide primer and incl taking down existing old unserviceable poles complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.) Note :- Excavation incl earth work and PCC foundation will be measured and paid separately.
14S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated stranded aluminium conductor one twin core cable flat or circular of size 4 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections complete all as specified and as directed
15S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated stranded aluminium conductor one twin core cable flat or circular of size 10 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections complete all as specified and as directed
16Supply , fixing and testing of 3 phase automatic street light switch using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is ‹ 30 Lux and for switching OFF › 10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 54 degree of ingress three phase 12 KW lightning load capacity including mounting bracket , cable glands, openable doors with lock complete all as specified and directed. The contactor MCB and circuit wiring should suitable enough to take load of 12 KW equally distributed over three phase and street light timer should be comprising of following:- (a). Input MCB (3 Nos) rating 40 Amps (b).Contactor MCB (3 Nos) rating 40 Amps(c).Out put MCB (3 Nos) rating 40 Amps(d).Three phase circuit wiring minimum 10 Sqmm multistranded copper wire.Make & Model -SWADEEP -02EC12 KW3P ofKakatiya Energy Systems Ltd
17Supply & fixing of single phase automatic street light switch using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is ‹ 30 Lux and for switching OFF › 10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 54 degree of ingress single phase 8KW lightning load capacity including mounting bracket , cable glands, front openable doors fitted with hinges & locking arrangment complete all as specified and directed. The contactor MCB and circuit wiring should suitable enough to take load of 8 KW equally distributed over three phase and street light timer should be comprising of following:-(a). Input MCB rating 40 Amps (b).Contactor MCBrating 40 Amps(c).Out put MCBrating 40 Amps(d).Single phase circuit wiring minimum 10 Sqmm multistranded copper wire. (e)Model No :- SWADEEP -02EC5 KW1P. Make :- Kakatiya Energy Systems Ltd
18M&L PCC in mix 1:4:8 type D2 with 40 mm graded aggregate for poles / filling in mass concrete
19M&L for PCC 1:3:6 Type C2 for erection of pole in base with 40 mm gradede coarse agreegete complete all as specified and as directed.
20Excavationin trenches in any type of soilnot exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out Soft & loose soil complete all as specified and as directed.
21Excavationin trenches in any type of soil not exc 1.5 mtrs wide and not exc 3 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out Soft & loose soil complete all as specified and as directed.
22Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
23Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
24M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particalsin trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shallbe measured 18 cm after punning.
25Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection , laid flatie length of cable cover shall be laid across the cable, complete casted with PCC 1:2:4 Type B1 using 20mm graded crushed stone aggregateall as specified and directed
26M & L for road cutting incl necessary excavation 45 cm wide and90 cm in depth as in trenches in any type of soils/rock for laying LT UG cable throughpipeafter laying /through the cable trenches will be fillingtop withM&L PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm bolders 100 mm dia over filled and rammed earth to make good the disburbedsurface etc complete all as specified and directed.
27Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge.

AI Tender Summary

OUR REF NO 45520026
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 22-10-2024
Authority
Authority Name Military Engineer Services
Work Description Tender For Repair/Replacement Of Street Lights Poles Automatic Switches Connection, Cables Allied Works At Phase Ii Chindit Top Tenga Ledge Goc Camp Area Of Age E/M Under Ge Tenga
Basic Detail
Tender No 8645/E8
Bidding Type Tender
Location
City Tenga Valley
State Arunachal Pradesh
Key Dates
Publish Date 01 Oct 2024
Submission Date 22 Oct 2024
Open Date 23 Oct 2024
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
BOQ_757817.xls
tender65.pdf
186b97a4-c023-4940-a1b6-01625f688f56.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 23, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_757817.xls

pdf

tender65.pdf

html

186b97a4-c023-4940-a1b6-01625f688f56.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail