| 1 | ROAD WORK |
| 2 | (i) Construction of HPC Culvert on Budhwara to Kalesara road (VR 347) Ch 0/750 |
| 3 | Earthwork in excavation in foundation trenches etc. not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil 3m. Clear from the edge of excavation and subsequent filling around hume pipes/masonry in 15cm layers with compaction including disposal of all surplus soil as directed within a lead of 1000 metres.[MoRTH Specification : Clause 301,304].Ordinary Soil |
| 4 | Providing and laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5 metres below ground level and 1.50 metres above Ground/Bed level as per MoRTH Specification : Clause 1000 & 1700 P.C.C. 1:4:8 mix with crushed stone aggregate 20 mm nominal size. |
| 5 | ProvidingandlayingPlaincement concrete mix with stone aggregate 20 mm nominal size mechnicallymixedandvibrated in foundationup toadepthof1.50 metresbelow ground leveland/or1.50 metres aboveground/bed level as per MoRTH specification : clause 1000 & 1700. with all lead R.C.C. grade M-20 in superstructure upto 4.5 mtr. from ground level excluding cost of steel reinforcement but including the cost of centering & shuttering |
| 6 | Providing & fabricating steel reinforecemnt for RCC work including cutting, bending, placing in position and binding complete including cost of binding wire as per MoRTH Specification : Section 1000 & 1600 TMT Steel reinforcement |
| 7 | Providing, laying & fixing in position RCC spun or hume pipes ISI marked with proper jointing in required slope packed in the gasket of hume or spun yarn and neatly finished with rich grout of cement moratar 1:3 or having flexible rubber ring joint made with prefectly air and water tight including testing of joints as per MoRTH Specfication : Clause : 1000 & 2900 NP - 3 1200 mm dia |
| 8 | ProvidingandlayingPlaincement concrete mix with stone aggregate 20 mm nominal size mechnicallymixedandvibrated in foundationup toadepthof1.50 metresbelow ground leveland/or1.50 metres aboveground/bed level as per MoRTH specification : clause 1000 & 1700. with all lead P.C.C. grade M-15 in superstructure upto 4.5 mtr. from ground level |
| 9 | Providing and laying granular sub-base material having P.I.not more than 6, including compacted thickness and consolidation by 8-10 tonne power roller at OMC to achieve desired density to required camber and grade including cost of water and hire charges of machinery, including T&P and all lead of material from quarry (compacted thickness to be measured). Grading as per MoRTH specification : Table 400-1,400-2 with CBR value not less than 15. To achieve 100% Proctor density |
| 10 | Construction of dry lean cement concrete sub- base over a prepared sub - grade with coarse and fine aggregate conforming to IS : 383, the size ofcoarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15 : 1, aggregate gradation after blending to be as per Table 600 -1, cement content not to be less than 150 Kg/Cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at7 days, mixed in a batching plant as per mix design, transported to site, laid with a hydrostatic paver with electronic sensor, compacting with 8 -10 tonne vibratory roller, finishing and curing complete as per MoRTHspecification clause 601. |
| 11 | Construction of un-reinforced, dowel jointed, plain cement concrete pavement M-30, over a prepared sub-base with 43 grade cement @ 400 Kg per cum, coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrance, sealant primer, joint sealant, debonding strip, admixtures as approved, curing compound, finishing to lines and grades as per drawing complete as per MoRTH specification clause 602. |
| 12 | Providing A.C pipe Weep holes 150mm dia in Masonry/Plain Concrete/.Reinforced Concrete abutment, wing wall/return wall complete as per drawing and technical specfication as per MoRTH Specification Clause 2205 |
| 13 | (ii) Construction of Box Culvert on Hatoondi Tabiji Daurai Road in Km 9/200 |
| 14 | Earthwork in excavation in foundation trenches etc. not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil 3m. Clear from the edge of excavation and subsequent filling around hume pipes/masonry in 15cm layers with compaction including disposal of all surplus soil as directed within a lead of 1000 metres.[MoRTH Specification : Clause 301,304].Ordinary Soil |
| 15 | Providing and laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5 metres below ground level and 1.50 metres above Ground/Bed level as per MoRTH Specification : Clause 1000 & 1700 P.C.C. 1:4:8 mix with crushed stone aggregate 20 mm nominal size. |
| 16 | ProvidingandlayingPlaincement concrete mix with stone aggregate 20 mm nominal size mechnicallymixedandvibrated in foundationup toadepthof1.50 metresbelow ground leveland/or1.50 metres aboveground/bed level as per MoRTH specification : clause 1000 & 1700. with all lead R.C.C. grade M-20 in superstructure upto 4.5 mtr. from ground level excluding cost of steel reinforcement but including the cost of centering & shuttering |
| 17 | Providing & fabricating steel reinforecemnt for RCC work including cutting, bending, placing in position and binding complete including cost of binding wire as per MoRTH Specification : Section 1000 & 1600 TMT Steel reinforcement |
| 18 | Providing and laying Precast reinforced cement concrete Box culvert section of M-40 grade designed for \"AA\" class loading as per IRC specifications including to effect of impact, EQ etc. complete on form base of 200mm thick lean concrete of M-10 grade with aggregate of size 40mm nominal of following internal size the work includes required safety measures construction of drain for diversion of flowing water cost of design of RCC Precast Box and its proof checking from IIT/MNIT Jaipur complete in all respect as per specifications Size 1.50 M x 1.50 M |
| 19 | ProvidingandlayingPlaincement concrete mix with stone aggregate 20 mm nominal size mechnicallymixedandvibrated in foundationup toadepthof1.50 metresbelow ground leveland/or1.50 metres aboveground/bed level as per MoRTH specification : clause 1000 & 1700. with all lead P.C.C. grade M-15 in superstructure upto 4.5 mtr. from ground level |
| 20 | Providing and laying granular sub-base material having P.I.not more than 6, including compacted thickness and consolidation by 8-10 tonne power roller at OMC to achieve desired density to required camber and grade including cost of water and hire charges of machinery, including T&P and all lead of material from quarry (compacted thickness to be measured). Grading as per MoRTH specification : Table 400-1,400-2 with CBR value not less than 15. To achieve 100% Proctor density |
| 21 | Construction of dry lean cement concrete sub- base over a prepared sub - grade with coarse and fine aggregate conforming to IS : 383, the size ofcoarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15 : 1, aggregate gradation after blending to be as per Table 600 -1, cement content not to be less than 150 Kg/Cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at7 days, mixed in a batching plant as per mix design, transported to site, laid with a hydrostatic paver with electronic sensor, compacting with 8 -10 tonne vibratory roller, finishing and curing complete as per MoRTHspecification clause 601. |
| 22 | Construction of un-reinforced, dowel jointed, plain cement concrete pavement M-30, over a prepared sub-base with 43 grade cement @ 400 Kg per cum, coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrance, sealant primer, joint sealant, debonding strip, admixtures as approved, curing compound, finishing to lines and grades as per drawing complete as per MoRTH specification clause 602. |
| 23 | Providing A.C pipe Weep holes 150mm dia in Masonry/Plain Concrete/.Reinforced Concrete abutment, wing wall/return wall complete as per drawing and technical specfication as per MoRTH Specification Clause 2205 |
| 24 | Dismantling upto 1.5m in foundation and/or 1.5m above ground level including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material, and stacking serviceable material withina lead of 1000m. [MoRTH Specification clause 202] Concrete Cement Concrete plain 1:3:6 mix. |
| 25 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered or concrete surface as per MoRTH specification clause 803 |
| 26 | P& F Mukhya Mantri Sadak Yojana logo for roads funded by State road fund having M.S. Definition plate of 1.6mm thickness frame to steel hollow dsection of 75mm x 75mm, 2.5m long stove enamelled paint with hold fast including paint logo as per approved design and colours. The logo shall be made out of 1.6mm thick circular plate fix on 1200mm x 150mm rectangular steel base plate 1.6mm thick, the base of circular shall be plain at the junction of base plate. The size of definition plate shall be 1500x600mm and embedding the posts by M-15 mix C.C. block 300x300x600 mm including lettering / writing and painting etc. complete in all respect |