Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #45498926

Tender For Comprehensive Repair/Maint Of Lt Cable Lt Panel U/G Cables Security Lights Poles And Connected Works At At Ph-Ii Chindit Top Tenga Ledge Goc Camp Area Of Age E/M Under Ge Tenga

Issued by Statutory Bodies & Commissions/Committees · Tenga Valley, Arunachal Pradesh
Tender Value
45 Lakhs
Estimated cost
Bid Submission
21 Oct 2024
0 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tenga Valley → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Comprehensive Repair/Maint Of Lt Cable Lt Panel U/G Cables Security Lights Poles And Connected Works At At Ph-Ii Chindit Top Tenga Ledge Goc Camp Area Of Age E/M Under Ge Tenga

BOQ

Nature of Work: COMPREHENSIVE REPAIR/MAINT OF LT CABLE,LT PANEL, U/G CABLES, SECURITY LIGHTS, POLES AND CONNECTED WORKS AT AT PH-II (CHINDIT TOP,TENGA LEDGE, GOC CAMP AREA) OF AGE E/M UNDER GE TENGA.
Sl. No. Item Description
1Excavationin trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out hard & densile soil complete all as specified and as directed.
2Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
3Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
4M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particalsin trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shallbe measured 18 cm after punning.
5Supply and laying un-reinforced precast.concrete cable protection cover of class LV, type-1, flat size 250mm x 150mm x 40 mm,factory madeof specified make , complete all as specified and directed.
6Supply, installing, testing and commissioning, factory made and tested ,CPRI type testedLTfeeder pillar, outdoortype floor mounted ,suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hightand fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,both side openingtype, with aprons for cable entry,with double door shutter and locking arrangement and consisting of the followingall as specified including taking out oldfeeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following:- (a) Aluminiumbus barfour Nos1000 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulatedwithheat shrinkable sleeves in colour code - 04 Nos, Incoming:- (b) ACB,04 Pole, 630 Amps with ultimate breaking capacity Icu- 50 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 No(Ics=Icu=100%), Outgoing:- (c) MCCB,04 Pole, 200 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 03 No(Ics=Icu=100%), (d) MCCB,04 Pole, 160 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 04 No(Ics=Icu=100%), (e)Spare way for MCCB 200 Amp 4 pole - 01 Nos, (f) Digital type volt meter 0-630 volt with selector switch withHRC fuses/ MCBs - 1Set, (g) Digital type ammeter meter 630 Amp with selector switch withHRC fuses/ MCBs - 1Set. (h) LED phase indication lamps R,Y,BLEDtype with 3 Nos of 2A HRC Fuses – 1 set, (i) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminumstrips for MCCB\"s, (k) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel
7Supply, installing, testing and commissioning, factory made and tested ,CPRI type testedLTfeeder pillar, outdoortype floor mounted ,suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hightand fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,both side openingtype, with aprons for cable entry,with double door shutter and locking arrangement and consisting of the followingall as specified including taking out oldfeeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following:-(a) Aluminiumbus barfour Nos400 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulatedwithheat shrinkable sleeves in colour code - 04 Nos Incoming:- (b) MCCB,04 Pole, 250 Amps with ultimate breaking capacity Icu- 50 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 No(Ics=Icu=100%), Outgoing:- (c) MCCB,04 Pole, 100 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 04 No(Ics=Icu=100%), (d)Spare way for MCCB 100 Amp 4 pole - 01 Nos, (e) Digital type volt meter 0-300 volt with selector switch withHRC fuses/ MCBs - 1Set, (f) Digital type ammeter meter 400 Amp with selector switch withHRC fuses/ MCBs - 1Set, (g) LED phase indication lamps R,Y,BLEDtype with 3 Nos of 2A HRC Fuses – 1 set, (h) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminumstrips for MCCB\"s/SDFU, (j) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel
8S&F & testing commissioning of outdoor type bus bar panel pedestal type weather proof CPRI approved MS cubical panelboard outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos ofbus bar of 300 Amp capacity & MCCB 160 Amp capacity 4 pole (Ics = Icu = 100%) including one coat of red oxide and two coat of enamel paint powder coated, mounted on channels and PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. The panel shall be fixed over Angle iron frame (50 x 50 mm) of minimum height 75 cmNote :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel
9Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 150 sqmm 3.5 core including taking down of old unserviceable UG cable/service wires.
10Description all as per item No 09 above but of size 120 Sqmm 3.5 core
11Description all as per item No 09 above but of size 95 Sqmm 3.5 core
12Description all as per item No 09 above but of size 70 Sqmm 3.5 core
13Description all as per item No 09 above but of size 50 Sqmm 3.5 core
14Description all as per item No 09 above but of size 35 Sqmm 3.5 core
15Description all as per item No 09 above but of size 25 Sqmm 4 core
16Description all as per item No 09 above but of size 25 Sqmm 2 core
17Description all as per item No 09 above but of size 16 Sqmm 4 core
18Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 300 sqmm single core including taking down of old unserviceable UG cable/service wires.
19M&L for replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 60 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable street light any type/any capacity including replacement of twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from junction box to LED light throgh copper connectos all as specified and directed.
20Supply and laying galvanised tube light gradeISI marked of size 40 mm dia incl all fittingsin trenches/fixed on pole/wall/floor or laid in positioncomplete all as specified and directed.
21M&L for road cutting incl necessary excavation 45 cm wide and90 cm in depth as in trenches in any type of soils/rock for laying GI/PPR pipeafter layingGI pipe trenches will be filled up to road level with 15cm PCC 1:3:6 type C1 using 20mm grade stone aggregate over 15cm 63mm gauge boulders over 15cm 100mm size boulders over rammed/compacted earth all as per specified and directed by Engr-in-Charge.
22Supply and laying Double wall corrugated HDPE duct pipe 50mm outer dia confirming to IS: 14930 (Part-II) of approved colour with fittings for cable protection complete laid in trenches or fixed on walls with clamps of suitable size all as specified and directed by Engineer-in-charge.
23Supply and laying Double wall corrugated HDPE duct pipe 80mm outer dia confirming to IS: 14930 (Part-II) of approved colour with fittings for cable protection complete laid in trenches or fixed on walls with clamps of suitable size all as specified and directed by Engineer-in-charge.
24S & F in replacement of MCCB,04 Pole, capacity 63 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed.
25Description all as per item No 24 here in above but of capacity 125 Amps with ultimate breaking capacity 25 KA and ditto-
26Description all as per item No 24 here in above but of capacity 160 Amps with ultimate breaking capacity 25 KA and ditto-
27Description all as per item No 24 here in above but of capacity 250 Amps with ultimate breaking capacity 35 KA and ditto-
28Description all as per item No 24 here in above but of capacity 400 Amps with ultimate breaking capacity 36 KA and ditto-
29S & F in replacement of change over switch with advanced neutral,63 Amps, 4 pole, AC 415 Volt, manual Change over insheet metal enclosure including side operating handle conforming to IS:13947 (Part-3) complete all as specified and directed.
30Description all as per item No 29 here in above but of capacity 100 Amps and ditto-
31Description all as per item No 29 here in above but of capacity 200 Amps and ditto-
32M&L for earthing complete with galvanised steel earth plate electrode 60x60cmx6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, RCC pit cover , charcol, salt including provision of earth lead protected by 32 mm dia light grade GI pipe and 20 mm dia medium grade GI Pipe for watering complete.

AI Tender Summary

OUR REF NO 45498926
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 21-10-2024
Authority
Authority Name Military Engineer Services
Work Description Comprehensive Repair/Maint Of Lt Cable Lt Panel U/G Cables Security Lights Poles And Connected Works At At Ph-Ii Chindit Top Tenga Ledge Goc Camp Area Of Age E/M Under Ge Tenga
Basic Detail
Tender No 8648/E8
Bidding Type Tender
Location
City Tenga Valley
State Arunachal Pradesh
Key Dates
Publish Date 30 Sep 2024
Submission Date 21 Oct 2024
Open Date 22 Oct 2024
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
Tendernotice_1.pdf
BOQ_757506.xls
eed69c4b-a176-409c-8dfb-08d2e601a53d.html
tender48.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 21, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 22, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

xls

BOQ_757506.xls

html

eed69c4b-a176-409c-8dfb-08d2e601a53d.html

pdf

tender48.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders