| 1 | Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified. |
| 2 | Material & labour for 75mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in hard standing ,plinth protection/path etc,laid in suitable panels not exceeding 3.00 m length finished even and smooth without using extra cement with contraction(Dummy)joints 65mm deepx10mm wide Joints filledwithbituminous sealing compound of grade ‘A’/bitumen mastic filler/sealant complete all as specified and directed by Engineer-in-Charge. |
| 3 | Dismantling brick tiles in floor or in roofs laid dry and pointed in cement mortar all as specified. |
| 4 | Demolition ofMud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof roof complete all as specified and directed by Engineer-in-Charge. |
| 5 | M & L for 40mm thick cement concrete type B0 1:2:4 (12.5mm graded aggregate) as in, surface finished even and smooth without using extra cement . |
| 6 | Material and labour for Preparing surface of top roof slab including sides of parapits and cleaned of all foreign materials such as fungues, moss, dust, loose particle etc by wire brushing, sprinkling water on the surface and ensure water does not stand anywhere. If it is so, the roof surface shall be leveled with cement mortar and after that surface shall be painted with one coat of cold applied bituminous primer @ 0.40 ltr per sqm, applied over primed surface APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application, torching with overlaps as recommended by the manufacturer complete all as specified and as directed by Engineer-in-charge. |
| 7 | M&L 40mm thick brick tiles laid/beded including screed bed 15mm thick in cement mortar (1:6) on existing lime concrete sufaces of roof,joints grouted flush in cement mortar (1:3) mixed with liquid WPC @ as per manufacturer instruction per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and directed by Engineer - in - Charge. |
| 8 | M&L 40mm thick brick tiles( old serviceable tiles obtained from demolition/desmantled item shall be reused) laid/beded including screed bed 15mm thick in cement mortar (1:6) on existing lime concrete sufaces of roof,joints grouted flush in cement mortar (1:3) mixed with liquid WPC @ as per manufacturer instruction per bag of cement of 50kg and including flush pointing as work proceed with same material complete all as specified in clause 11.27.3 of MES Sch Part-I (2009) complete all as specified and directed by Engineer - in - Charge. |
| 9 | Dismantlingof reinforced cement concrete (by chisel or mechnical cutter) of any description and in any position as in roofs, floors (other than ground floor), beams, landing, chajjas and similar suspended work. |
| 10 | Reinforced cement concrete M-25Design mix, type using 20mm graded stone aggregate in slab supported on walls,beams and columns in floors,roofs,landings,balconiies,deck slabs and in shelves and the like all as specified and directed. (form work & reinforcement measured separately). |
| 11 | M & L mild steel TMT bars 10mm dia or over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as in column, beam etc . |
| 12 | M&L for Form work to soffits of suspended slabs such as roof slabs,floor slabs,landings and similar work not exc.200 mm thick(horizontal or sloping)rough finish surface of concrete flat all as specified and directed. |
| 13 | M&L forFormwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etcall as specified and directed. |
| 14 | M&L for precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in cover slab of drain/manhole set in cm (1:6). ( Note : Cost of Form Work is deemed to be inclusive of unit rate quoted by the contractor & reinforcementshall be measured & paid Separately.) |
| 15 | Taking down chowkatsor frame with shutters(without taking off shutters from the frame not exceeding 1.50 sqm each & removing to store all as specified. |
| 16 | Taking down chowkatswith shutters(without taking off shutters from the frame exceeding 1.50 sqm each but not exceeding 4 sqm) |
| 17 | Supply and fixingfactory made pressed steel frames of size 125 x 60mm (thickness of sheet shall be 1.25mm) for doors with one or more rebates including necessary lugs and lock strike plate, etc. , includingbutt hinges suitable Nos as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. |
| 18 | M&L Cement concrete 1:3:6 type C-1 for filling of pressed steel frame and hold fast blocks etc complete all as specified and directed by Engineer - in - Charge. |
| 19 | S & F Factory made Plain framed, panelled shutter IInd class hardwood rail and style 35 mm thickness (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer - in - Charge. |
| 20 | S & F Factory made 35mm thick IInd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part – I, Section – 8, clause 8.20 (a) ; supplied and fitted to chowkats complete all as specified and directed by Engineer - in - Charge. |
| 21 | Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and choppedmat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer andas per directions of Engineer-in-charge.Make- \"Fiber ways, Slected and equivalent. |
| 22 | Supply and fixing 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate forpanels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge.Make- \"Fiber ways, Slected and equivalent. |
| 23 | S & F100 mm Butt hinges, stainless steel Butt hinges,,and fixed with steel scerws for wooden doors, complete all as specified and directed by Engineer - in - Charge. |
| 24 | S & F tower bolt 200 mm of aluminum complete all as specified and directed by Engineer - in - Charge. |
| 25 | S & F door handle D type 150 mm of aluminum complete all as specified and directed by Engineer - in - Charge. |
| 26 | S & F Aluminium alloy, anodised, sliding door bolt 300mm with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudedsections or cast-aluminium alloy and fixed |
| 27 | S&F Floor door stopper of aluminum allow body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floor. |
| 28 | S & F mild steel 300mm ordinary rat rail rod pattern spring inluding roller and roller plate complete all as specified. |
| 29 | S& FStainless steel curtain rod 25 mm dia , including fancy type brackets and pair of decorated end knobs (finials), stop roller etc.as per site requirement, fixed to wall with fixing accessories,including taking down old existing curtain rods any description complete all as specified and directed by Engineer - in - Charge. |
| 30 | S&F steel ventlators with top hung shutters including box type hinges, steel peg stay complete |
| 31 | S & FSteel windows with side hung shutters including box type hingeswith steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded (Glazed steel window) |
| 32 | S &F steel windows with side hung shutters including box type hinges , steel handle with fixing arrangement for wire gauge windows etc complete (wire gauge steel window) |
| 33 | Supply only stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18 mm all as specified. |
| 34 | S & F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18 mm all as specified. |
| 35 | S & F 4 mm thick sheet glass ordinary quality and glazing within square not exceeding 0.50 sqm including aluminium cleat/rubber beading in each pane complete all as specified and directed by Engineer - in - Charge. |
| 36 | S & F figured glass 4 mm thick pin head type and glazing withnot exceeding 0.50 Sqmincluding aluminium cleat/rubber beading in each pan complete all as specified and directed by Engineer - in - Charge. |
| 37 | Material and labour for machine cut 16 to 18 mm thick, Kota stone slab (size of slab not less than 500x550mm for flooring and in single piece for treads of staircase), laid over and including 20 mm thick bedding layer in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish) andpolishing by machine, including machine cutting to make it square or rectangular as per site complete all as specified and as directed by Engineer-in-Charge. |
| 38 | Material and labour for machine cut 16-18mm thick, Kota stone slab as in skirting, dado and on pillar, laid over and including 10 mm thick bedding layer in cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish ) and polishing by machine, including machine cutting to make it square or rectangularcomplete all as specified and as directed by Engineer-in-Charge. |
| 39 | Taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc. |
| 40 | M & Lfor rendering 15mm thik on fair faces of brick work in cement mortar 1:6 finished even & smooth without using extra cement. |
| 41 | M & Lfor rendering 15mm thick on fair faces of brick work in cement mortar 1:4 finished even & smooth without using extra cement. |
| 42 | M&L rendering10 mm thick in cement mortar 1:3 on fair faces of concrete surfaces of ceiling finishing even and smooth without using extra cement. |
| 43 | M&L Integal water proofing compound |
| 44 | M&L for two coat of cement base paint over a coat of alkali resistant cement primeron newly plastered surface including preparation of undecorated surface complete all as specified and as directed |
| 45 | M&L preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling. |
| 46 | M & L Preparation of newly plastered surfaces andapplying two coats of Acrylic distemper over one coat of cement primer including all as specified by mechanical method i.e. spray gun all as specified and directed by Engineer-in-charge. |
| 47 | M & L providing two coats of synthetic enamel paint over new steel surfaces and a coat of red oxide primer onincluding preparation of surface of any description not exceeding 10 cm width or girth complete all as specified and directed by Engineer -in -charge. |
| 48 | M & L providing two coats of synthetic enamel paint over new wooden surface including preparation of surface withprimer all as specified. |
| 49 | M&L for preperationof old steel surface and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer -in -charge. |
| 50 | Shotcreting 25MM thick in RCC columns, beams and slabs, Chajja etc in layers with approved design mix (minimum cement content of 350 Kg/Cum on M-25) concrete having the specified minimum characterristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of certering and shuttering at edges and corners etc as directed by Engineer-in-Charge including Chipping of unsound /weak concrete material 25 mmaverage thickness from slabs,beams, columns etc with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with Dr Fixit epoxy zinc primer@ 6sqm/ltr at DFT of 100microns as per specifications and disposal of debries for all lead and lifts all complete as per direction of Engineer-in-Charge. |
| 51 | S&FHard drawn steel wire fabric not exc 4Kg/Sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemntall as specified & directed by Engineer-in-Charge. |
| 52 | M & L 5mm thick rendering in Cement Mortar 1:3 on fair facesof brick work or concrete surfaces of ceiling finished even and smooth without using extra cementcomplete all as specified and directed by Engineer - in - Charge . |
| 53 | Dismantling of cast iron pipes jointed in cement mortar and taking out from trenches walls etc upto 100 mm bore all as specified and directed by Engineer - in - Charge . |
| 54 | S & F PVC(SWR) 110 mm bore Pipes single socketed in any length with rubber ring joints,laid in trenches or in floorsIS 4985-2000 in pressure rating 6Kgf/sq.cm and complete all as specified and directed by Engineer - in - Chargeall as specified and directed by Engineer - in - Charge. |
| 55 | S&F PVC (SWR)branch pieces single /double (equal or unequal) ordinary or inverted with parallel branches 110mm boreIS 4985-2000 in pressure rating 6Kgf/sq.cm and complete all as specified and directed by Engineer - in - Charge |
| 56 | S&F PVC(SWR) bend ( any radius) dimenshing pieces or tappers ( large bore measured) 110mm boreIS 4985-2000 in pressure rating 6Kgf/sq.cm and complete all as specified and directed by Engineer - in - Charge |
| 57 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc . |
| 58 | M&L for Brick work using fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge. |
| 59 | Labour only forBrick work built in CM (1:6) with subclass \"B\" bricks, straight or curved on plan exceeding 6m mean radiuswith Reusing the old bricks obtained fromitem no 5 . |
| 60 | S & F of Collapsible steel gates, top hung, consisting of channel pickets, pivotedflat bars, top and bottom runners, brass handles etc., as specified, erected inposition and securing runners with holdfasts and brackets, complete |
| 61 | Taking downAluminium door/Aluminium partation wall ,(size of each exceeding 2.00 sqm to 10.00 sqm ) Refixing in the same opening after tightening/ screwingof members ,refixing with RCC column / Brick wall inludingrubber bedding & adjusting oftop and botom member of the door/ Aluminium partation wall complete. |
| 62 | M&L for 100 mm thick Sand stone slabs in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cementmortar 1:4. complete |
| 63 | Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and rubbish off the permices. |
| 64 | M &L for Double charged Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match 15 mm thick screed bed in CM 1:4 . |
| 65 | M & L Rendering 15 mm thickon fair faces of brick work or concrete surfaces, in cement mortar (1:4),in two layers of 10+5mm thick with using water proofing compoundas per manufacturer\"s instructions,surfaces finished even and smooth without using extra cementcomplete all as specified. |
| 66 | M & L 15mm thick rendering in Cement Mortar 1:3 on roof surfaces finished even and smooth without using extra cement complete all as specified. |
| 67 | M & L Preparation of newly plastered surfaces by applying two coats of interior grade wall putty and making it smooth with sand paper by mechanical method i.e. with hand electric grinder then applying two coats of Acrylic distemper over one coat of cement primer including all as specified by mechanical method i.e. spray gun all as specified and directed by Engineer-in-charge. |
| 68 | M&L for preparation ofnewly plastered surfaces two coats of exterior grade wall putty each coat 1mm thick and making it smooth with sand paper by mechanical method then applying one coats of weather proof exterior emulsion over a coat of exterior primer complete all as specified and as directed by Engineer-in-Charge. |
| 69 | M&L for preparation of old distempered surfaces of walls by washing, rubbing down, stopping nail holes, fillings cracks with putty etc and applying one coat of Acrylic distemper on walls. |
| 70 | M & L Preparation of Old plastered surfaces by removing old treatment and applying two coats of interior grade 1mm wall putty and making it smooth with sand paper by mechanical method i.e. with hand electric grinder then applying two coats of Acrylic distemperover one coat of cement primer including all as specified by mechanical method i.e. spray gun all as specified and directed by Engineer-in-charge. |
| 71 | M&L for complete removal of existing treatment including filling depression of scraped surface with wall putty two coats 1.5 mm thick each on Old external wall surfaces of any desciption , prepratio of surface by Mechanised sander having suction vaccum Bag using Smart periodical methodology , complete all as specified and applying the following :-(a) M&L two coats of exterior acylic emulsion by using Airless spray / Roller over and incl a coat of acrylic emulsion external primer complete all as specified Note : Contractor may use manual scraping tools for complete removal and surface prepration with prior approval of Engr-in-chrge in case of where using of Mechanical equiment are not posiible |
| 72 | S&F Aluminium handle cast type anodized 125 mm long |
| 73 | M&L Granite 16 mm thick(of any type)machine cut , bedded and jointed with grey cement slurry and pointed with white cement with admiture of pigment to match the shade of granite stone including 15 mm thick screed bed1:4 grinding and polishingcomplete. including PCC , B-2 type (1:2:4) as sub base of granite. |
| 74 | S & Fvitrous china ovalwash hand basin white of small size 550x400 mm including brackets 300mm long PVC connection with brass nuts, 40mm dia waste coupling including cutting for and pinning in end of brackets or erecting stand etccoloured top bowl type screwed shank fly nut flange end including cutting for and pinning in granite slab of hole including 32 mm dia chromium plated waste coupling and bottle trap all as specified .(MAKE- Hindwareor equivalent in Parryware) |
| 75 | S&F15mm bore bib taps,chromium plated, fancy type,cast copper alloy with crutch or butterfly handle , screwed down, secrewed for iron pipe or for brass ferrule complete all as specified and directed by Engr-in- charge. |
| 76 | S & F 15mm bore Angle cockchromium plated fancy type , high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified . |
| 77 | S&F 15 mm bore stop valve coppper alloy screwed down high pressure, with crutch or buttrtfly handle , screwed both ends for iron pipe or for iron pipe or for union and fixed , but fancy concealedtype, chromium plated |
| 78 | S & F 15mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor all as specified. |
| 79 | M&L for taking down carefully point wiring complete including fixture and fittings from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. and making good to disturbed area all as specified |
| 80 | M&L for Point wiring complete with ISI marked 1.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through concealed in wall/ceiling surface and its accessories includingPVC rigid concealed conduit heavy duty suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switchs, sockets, fan regulator etc covered with 3 mm thick plastic laminated Hylem top cover sheet of required color fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer includingfixing and 1.5 sqmm copper conductor as earth continuity to connect common earth dolly completed for the following all as specified |
| 81 | (a) One light point/Fan point/Exhaust controlled byone way switch |
| 82 | (b) One 5 pin socket out let 5 amps on the same board with other switches |
| 83 | (c) One 5 pin, 5A socket outlet point on independent board with other switches. |
| 84 | All as per item no. 80 here-in-before but with 2.5 sqmm cable for 1No 16 amps socket outlet point on independent board including 2.5 sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor all as specified |
| 85 | S&F Piano type switch single pole 1 way 5/6 amps 230 volt AC supply complete all as specified |
| 86 | S&F Socket two in one 6/5 Pin 5 Amps230 volt AC supply complete all as specified. |
| 87 | S&F Piano type switch single pole 1 way 15/16 amps 230 volt AC supply complete all as specified |
| 88 | S&F Socket two in one 6/5 Pin 15/16 Amps230 volt AC supply complete all as specified |
| 89 | S&F Ceiling rose surface type, 65mm x 50mm three terminals, 3 phase / PVC / polycarbonate isolated body all as specified |
| 90 | S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with LED bulb 09 watt complete all as specified |
| 91 | Supply and fixing LED lights fitting 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 92 | Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete.Make COMPACT |
| 93 | S&F sheet metal enclosure for DB\"s SPN 230 volts 8 way with 200 amps rated bus bar neautral link, earth bar double door complete all as specified |
| 94 | Supply and fixing 415V 10KA \"B\" curve miniature circuit breaker (MCB) of cap 40 to 63 amps single poles and current carrying capacity in the DB complete with connection testing and commissioning. |
| 95 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified |
| 96 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN 40 to 63 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified |
| 97 | M&L forsubmain wiring comprising single core , 2 Runs of 2.5 sqmm nominal cross sectional areamulti stranded copper conductor cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including appropriate dia. in surface/recessed PVC conduit and its fittings completeincluding provision of 1X2.5 sqmm nominal cross sectional areamulti stranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earthwire and using color code as per IS and specified and making good all disturbed work to match the existing complete incl taking down old UNSV sub main complete all as specified and directed by Engr-In-charge.( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 98 | Earthing complete with galvanised steel earth plate electrode of size 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 m below normal GL connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washersand earth strip protected by 15 mm dia GI pipe medium grade and connected to main distribution board panel/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completionincluding taking down old Unserviceable earthing any type all as specified |
| 99 | M &L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 X 16 sq. mm |
| 100 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) |
| 101 | S&F Exhaust fans (Heavy duty) 300 mm sweep230/240 volts single phase with self closing louvers GI off mode protection against birds etc and provision of cutting of walls suitabully for fixing exhaust fan and necessary plastering and making good the disturbed surface to match with existing complete all as specified. |
| 102 | Supply & fix Pedestal fans AC single phase 230/ 240 V of size 450 mm sweep with louver .Make : Bajaj |
| 103 | Excavation in trenches any type of soil , n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shaft, well, cesspits , manholes , pier hole etc n exc 1.5 m in depth and getting out for laying of cable complete all as specificed and directed. |
| 104 | Returning , filling in including, spreading , levelling , wateringand well reamming in layers not exc. 25 cm within the 1 mtr strech complete all as specificed and directed. |
| 105 | M & L for sand cushioning with dry coarse sand to under ground cable 23 cmthick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment. |
| 106 | M&L for Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 107 | Boring of holes under road, pavement, hard standing by trenchless technology usingn ultra sound technique and necessary machine including HDPE/GI pipe of 100 mm dia suitable for 0.4 mpa working pressure |
| 108 | M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat. |