| 1 | CIVIL WORKS |
| 2 | 15.2.2 Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix) |
| 3 | 2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 4 | 5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 5 | 50.6.1.4 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete |
| 6 | 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 7 | 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 8 | 13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 9 | 5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 10 | 10.25.2 Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 11 | 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 12 | 30.2.2 Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment). |
| 13 | 50.18.8.9.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 14 | 4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 15 | 5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size |
| 16 | 5.1.3 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 17 | 50.18.9.3.2 Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2 |
| 18 | 16.78.2 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBRValue-25 |
| 19 | 18.18.3 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore |
| 20 | od127518/2024_2025 Supplying and fixing of DUST BIN. External bin made of FRP material moulded with 3mm with Granite finish, Inner liner of FRP material to facilitate removal of garbage, Top lid made of FRP with 3mm thick. Chain to tie top cover with body of garbage bin. Approximately 3 feet or nearby height. |
| 21 | od127520/2024_2025 Operation and Maintenance of civil and electrical works such as street lighting system including maintenance of light fixtures & CCMS panel, communication charges, including labour, materials, cloud hosting charges etc. and maintenance of the places including pavements/footpaths, garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, herbs, hedge, flower beds, foliage, creepers etc. including cleaning, hoeing, weeding pruning etc.., removal of all kinds of wastes, and maintenance of other garden related works as directed by office-in-charge including cost of T & P material/articles shall be provided by the contractor and as per direction of officer in charge for a minimum of 3 years as per contract. |
| 22 | od127521/2024_2025 Providing & laying buffallo grass turf with existing ground prepared with proper level and ramming with tools wooden the the surface smoothen and light watering the same, with sprinkler and maintenance for 30 days or more till the grass established properly as per direction of officer in charge. |
| 23 | od127522/2024_2025 Supplying and fixing granite stone bollards 150 mm dia height 1100 mm fixed in cement concrete 1:2:4 ,900 mm above ground , (the size ,finish and designs of bollards to be approved by engineer in charge ) |
| 24 | od127523/2024_2025 Providing and fixing 40-50mm thick machine cut, rough natural finish, shell white colour Granite for stone seater/copping and similar locations, of size 60x30cm, laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, etc. complete at all levels. Area of slab over 0.50 sqm |
| 25 | od127524/2024_2025 :Providing and laying factory made anti skid stone finish, Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, of 60mm thickness & size/ shape of 455x455 mm , made by table vibratory method and PU coated, laid in required colour & pattern over 50mm thick compacted bed of 6 mm aggregate, compacting and proper embedding/laying of inter locking paver blocks into the aggregate bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. Paver block of M-35 grade with approved colour, design & pattern. |
| 26 | od127525/2024_2025 Providing and fixing 2x2x3 m Vendor Kiosk as per the Architectural detail drawing all complete as per the instruction of Engineer in charge |
| 27 | 10.28 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 28 | 13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 29 | od134985/2024_2025 Planting permanent hedges including digging of holes, 20 cm wide and 30 cm deep, refilling the holes with excavated earth mixed with farmyard manure, and supplying and planting hedge plants at 30 cm apart. Heliconia Psittacorum |
| 30 | od134987/2024_2025 Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 Cum per 100 Metres and supplying and planting hedge plants at 30 cm apart.- Rhoeo Plant and Ornamental Peanut |
| 31 | od134988/2024_2025 Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 Cum per 100 Metres and supplying and planting hedge plants at 30 cm apart.Maintenance of hedge for one year - Lorapetalum Plants (Red) |
| 32 | 30.2.3 Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. lead complete (sludge measured in stacks will be reduced by 8% for payment). |
| 33 | 30.2.4.1 Supplying and stacking at site dump manure from approved source, including carriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 20 mm |
| 34 | 30.2.8 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-incharge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 35 | 30.2.9 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-incharge |
| 36 | 30.2.13 Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). |
| 37 | od135184/2024_2025 :Providing and laying factory made antiskid stone finish , Cement Concrete cobble blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, of 60mm thickness & size/ shape of 100x100 mm , made by table vibratory method and PU coated, laid in required colour & pattern over 50mm thick compacted bed of 6 mm aggregate, compacting and proper embedding/laying of inter locking paver blocks into the aggregate bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. Cobble block of M-35 grade with approved colour, design & pattern. |
| 38 | od135204/2024_2025 Supply & Installation of animal sculptures of 1.2m height at play areas in cement concrete with suggested art including all cost of labours, materials, providing and fixing of scaffolding, finishing with white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete, painting with acrylic emulsion of approved brand and manufacture to give an even shade: two or more coat and finishing as directed by engineer in charge. |
| 39 | od135214/2024_2025 Supplying and fixing in position granite bench with back rest and two granite slab support ,fixed on ground with CC M15 (the quality of bench to be approved by Engineer in charge)with seat size 1500x450x75mm and leg size 450x75x600mm,Smooth and box cut granite required |
| 40 | 55.25 Lifting, conveying and fixing the newly casted RCC covering slabs of any thickness on top of drain in position including all labour charges and miscellaneous expenses etc complete |
| 41 | 2.1.1 Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 metres and earth filling in the depression/pit. Girth from 300 mm to 600 mm |
| 42 | 2.2 Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area |
| 43 | 13.5.F.P.1 Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M25 - Using concrete Mixer - Height upto 5m |
| 44 | od134961/2024_2025 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge) |
| 45 | 11.9 Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year |
| 46 | ELECTRICAL |
| 47 | od125635/2024_2025 Supply & Installation of 3M Height Architectural Post Top Pole along with Ornomental Cast Iron Components. The hot dip Galvanised pole should be provided with an inbuilt junction box to fix 32A connectors and 6A MCB, at the bottom - the inbuilt box should have a flush door of suitable size. The decorative pedastal to be mounted on a suitable size steel plate. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed RCC foundation. wind pressure calculation as per IS 875(part-3) & structural calculation report as per EN40 should be submitted to verify the pole design. Pole & it\"s parts are painted in 3 layer coating(coating thickness-100 microns minimum) in which 1st layer withetch primer, 2nd layer with epoxy primer & 3rd final layer with PU paint. |
| 48 | od125636/2024_2025 Supply, Installation, Testing, Commissioning of Post Top Mounting Type LED Decorative Luminaire having system wattage 40W. LED Chips of CREE/ NICHIA/ OSRAM/ SEOUL/ LUMILEDS make.The housing material should be spun Aluminium and polycarbonate protector, CCT of 3000K, CRI70, LED Life expectancy @L70 > 50000 hrs, IP66 ingress protection, Impact ressitance - IK09, Constant Current LED having Efficiency > 85%, Power Factor>0.95, THD< 10% Operature Temperature -10 deg C to + 50deg C. Systemwhich offers Protection against Short Circuit, Over- Voltage & Over- Current with in-built surge protection up to 4kv and an additional surge protection device of 10kV. LM report should be submitted from UL Authorised Laboratory. Sample should be submitted for approval from concerned engineer-in charge. |
| 49 | od125637/2024_2025 Supply and Installation of outdoor weather proof IP66 rated Junction Box including associated accessories of approved make |
| 50 | od125638/2024_2025 FEEDER PILLAR CUM 3phase CCMS PANEL FOR GROUP CONTROL Supplying, unloading at site, shifting to site, assembling, levelling, grouting, erecting, earthing Testing, & Commissioning of Street light Feeder Pillar boxes as per tender specification. The feeder pillar shall be for group control of LED with all hard wares for power, control and communication devices and required software. It Shall be a GPRS/GSM/ RF based remote street light monitoring system with capacity for self - protection from short circuit, over voltage and anti-theft alert, Latch relay is to be provided for switching operations. Auto MCB trip rectification should be there. Device capability for scheduling the on/off timings of lighting control switchgears based on the available sun-rise and sunset. Special emergency on/off facility with wireless control. System capability to capture and provide all electrical parameters at variable time intervals and live data collection timings. Enclosure should be mounted on pedestial stand and also Panel should have a water canopy and it should be IP 65 certified from NABL accrediated laboratory. Two Energy meters of ISI marking with 13779 standrads and accuracy class 1.0 specified by KSEB one for measuring energy consumption for revenue billing and another for IC4 inetgration data alerts and monitoring. |
| 51 | od125639/2024_2025 Supply, Installation, Testing and Comissioning of Nickel coated Copper bonded electrode made from low carbon steel. Earth rods and molecularly bonded with 99.9 % pure electrolytic copper with 250 micron coating, 17.2 mm dia with pressed contact including stainless steel nut, bolts and washers.Copper bonded rod of size (17.2mm x 2000mm) with 1 nos chemical bag of 25 kg. with all accessories. Approximate weight of copper electrode is 5.62 kg. The earth rod should be properly covered with UV resistant earth pit Chamber of top 300mm, bottom 400mm and height 280mm complied to IEC625615:2018 including boring of earth pit suitable for the earthing to be done as per the dimension of earth rod and it should be capable of holding 25kg electrafill compound. |
| 52 | 14.15.1 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal) |
| 53 | 5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earthelectrode, including connection/ termination with GI thimble etc. as required. |
| 54 | 90.12.5.38 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 4 sq mm |
| 55 | od125640/2024_2025 Supplying and making end termination with copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1KV grade as required for input and output of the cable 4 X 4 Sq.mm in flush terminal box of pole. |
| 56 | 1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 57 | 90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 58 | 90.12.5.40 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm |
| 59 | 9.1.32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |