Housing Urban and Rular Development Government Departments Closing in 0 days TDR #45496977

Tender For Infrastructure Dev. Of Govt. Hr. Sec. School At Bana

Issued by Government Departments · East Kameng, Arunachal Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Oct 2024
0 days left
EMD
7.70 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
East Kameng → Arunachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Infrastructure Dev. Of Govt. Hr. Sec. School At Bana

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Oct-2024 Corrigendum1 Date 21-Oct-2024

BOQ

Name of Work:Infrastructure Dev. ofGovt. Hr. Sec. School at Bana
Sl. No. Item Description
1C/O Academic Cum Administrative Building
2Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t
3Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
4Providing and laying cement concrete 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth
5Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
6Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
7Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
8Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
9Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
10Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with 1 : 1.5 : 3( 1 cement:1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
11Reinforced cement concrete work in shelves up to floor two level excluding cost of centering and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
12Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete.
13c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
14d) Lintels, beams, girders, bressumers and cantilevers etc.
15e) Column, pillars, posts and struts etc.
16Reinforcement of RCC work including bending, binding and placing in position complete.b) Cold twisted bars.
17Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).
18Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth.
19Extra for half brick masonry in superstructure above plinth level and up to floor two level.
20Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
21Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws.a) 38 mm thick best available local wood, class - B I
22Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws.a) 38 mm thick best available local wood, class - B I
23Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.b) Ornamental grill.
24Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 300 x 16 mm
25Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete.a) 300 x 10 mm
26c) 150 x 10 mm
27Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a) 125 mm
28Providing and fixing in position collapsible steel shutters with vertical channels 20 mm x 0 mm x 2 mm and braced with fiat iron diagonals 20 mm x 5 mm size.with top and bottom rails of T iron 40 mm x 40 mm_ x 6 mm with 38 mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
29Steelworkinbuiltuptubulartrussesincludingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately).
30Providing and fixing Durasr,ine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet ridges fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutling hoisting and fixing complete, excluding the cost of purlins, rafters and trusses.Details of cost for 11.75m Laying and fixing 4 lenths of 3.05m each require Overall length of 4 x 3.05 plus 3% wastages = 12.566m After laping as per manufacturer\"s specification, effective Measurable length wi be (4 x 3.05) - (3 Q..15) = 11.75m
31Providing ridges or hips 60 cm overall in plain G.I. sheet fixed with galvanised iron J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete.
32Providing and fixing 12 mm thick insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately).
33Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling.a) Best local approved quality wood.
34Extra for chamfered edges in beading
35Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) including grouting the joints with white cement and matching pigments etc, complete.d) size of tiles 1000x1000mm
36Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 course sand) including grouting the joints with white cement and matching pigments etc, complete.d) size of tiles 1000x1000mm
37White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.
38Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
39Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
40Chequered terrazzo tile_s 22 mm lhick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete:a) Light shades using white cement
4112 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
42Painting two coats with oil type wood preservative of approved brand and manufacture on new work.
43Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
44Applying one coat of distemper primer of approved brand and manufacture on wall surface.
45Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give even shade
46Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade
47Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).
48Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
49Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.
50Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a) 15 mm nominal bore
51b) 20 mm nominal bore
52Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a) 15 mm nominal bore
53b) 20 mm nominal bore
54d) 32 mm nominal bore
55Providing and fixing brass bib cock of approved quality.a)15 mm nominal bore
56Providing and fixing brass stop cock of approved quality.a) 15 mm nominal bore
57Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required.a) Long Pan patten WC Pan
58Providing and fixing white vitreous china pedestal type (European type WC pan) water closet with seat and lid with CP brass hinges and rubber buffers, 12.5 Litres white vitreous china low-level flushing cistern with fittings and brackets 40 mm white porcelain inenamelledflushband,20mmoverflowpipewithspecialsandmosquitoproof coupling of approved municipal design complete including cutting and making good the walls and floors where required.a) WC pan with white plastic seat and lid.
59Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required.b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality.
60Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC.a) 250 x 130 x 30 mm
61Providing and fixing 12.5 litres high level CI flushing cistern of approved make with integral fittings such as ball valve, bell, lever, GI chain and pull complete.
62Providing and fixing 100 mm sand PVC grating for gulley, floors or nahni trap.
63Providing and fixing sand UPVC/PVC (spun) soil, waste and vent pipes.a) 100 mm dia
64c) 50 mm dia
65Providing and fixing UPVC/PVC heel rest sanitary bend.a) 100 mm dia
66Providing and fixing PVC single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.a) 100 x 100 x 100 mm
67Providing and fixing PVC trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.c) 100 mm inlet and 50 mm outlet
68Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:
69Add Carriage Charges
70External service connection
71Cost for internal electrification
72Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
73Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
74Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
752 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
762 X 4 sq. mm +1 X 4 sq. mm earth wire
772 X6 sq. mm + 1 X 6 sq. mm earth wire
784 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire
794 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
804 X 4 sq. mm + 2 X 4 sq. mm earth wire
814 X 10 sq. mm + 2 X 6 sq. mm earth wire
824 X 16 sq. mm + 2 X 6 sq. mm earth wire
83Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
8425 mm
8532 mm
86Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
87Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
88Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
89Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
90Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
91Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as reqd.
92Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mm X 75mm)
93Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
94Cat6 RJ45 socket outlet
95Supply & fixing of telephone tag blocks with gas tight connecton with self- cleaning \"KRONE\" terminal connectors fixed in minimum 1.2mm thick powder coated, hinged, lockable door, sheet steel dust proof indoor enclosure including mounting frame and label holder including civil work such as chase cutting, fixing / concealing the box and making good as required including terminations:10 pair tele tag block
96Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable
972 run of cable
983 run of cable
99Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
100Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)12 way (4 + 36), Double door
101Supplying and fixing 5A to 32A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
102Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
103Supplying and fixing 40 A to 63 A rating, 415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
104Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
105Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 12 way, Double door TPN MCBDB
106Supplying and fixing of 160A Four Pole MCCB, 415 V, Breaking capacity of 16 kA (Ics= 100%Icu), Compact sized Din mountable, snap fitted Moulded Case Circuit Breaker (MCCB) with inbuilt adjustable Overload settings, conforming to IS/IEC: 60947-2 and IEC 60947-2, in the Enclosure complete with connections, testing and commissioning etc. as required.
107SUPPLY OF LIGHT FIXTURES AND FANS: Note:-The model numbers specified below are only for references for Shape of the product requirement. The product shall supplied, must match the technical specifications. The technical data sheets shall be arranged before the material dispatch and got approved from engineer-in- charge.Supply of 20W 1200mm LED fitting batten light.
108Supply of 12W round surface sleek LED fitting .
109Supply of 1200mm dia ofceiling fan complete withdouble ball bearing, motor,blades,downrod,canopy,capacitoretc.suitableforoperationon 230 volt, 50 Hz, A.C. supply complete as required.
110Supplying, installation and fixing of 250mm sweep energy saving PVC exhaust fans with low power consumption etc complete with base frame and mounting arrangement with lovers complete as required.
111INSTALLATIONS OF LIGHT FIXTURES AND FANS:Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
112Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
113Installation of exhaust fan upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc as required.
114Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
115EARTHING SYSTEM:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
116Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
117Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
118FIRE DETECTION AND ALARM SYSTEM ( CONVENTIONAL):Supplying, installation, testing & commissioning ofsmoke detector with builtin LED and mounting base complete with all connections etc. as required.
119Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
120Supplying, installation, testing & commissioning of response indicator on surface/recesss MS box having two LEDs metallic cover complete with all connections etc. as required.
121Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
122Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.6 Zone
123Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
124Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
125BUSBAR BOXBUBASR BOX-WALL MOUNTEDBusbar 200Amp, 4P, 25kA, Aluminium busbarsOutgoing4 Nos. Holes in 3 phase and Neutral busbar with hardwares suitable for outgoing cable connections upto 4Cx16 Sqmm Al Arm Cable.BUBASR BOX-WALL MOUNTED as described above and shown in SLD.
126Add Septic Tank(150 User)
127Earth work in excavation by mechanical means (Hydraulic excavator) I manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.0.00-1.50m
128Earth work in excavation by mechanical means (Hydraulic excavator) I manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.1.50-3.00m
129Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
130Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
131Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
132Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns, etc. for mass concrete.
133Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12mm thick.
134Edges of slabs and breaks in floors and walls.Under 20 cm wide
135Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars.
136Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in:Cement mortar 1:6 (1 cement :4 coarse sand)
13762 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume. Hardening compound is mixed @ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
138Cement plaster 1:4 (1 cement: 4 coarse sand) finished with a floating coat of neat cement. 20mm cement plaster
139Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved qualitySquare shape 450 mm internal dimension
140Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
141Providing and fixing soil, waste and vent pipes100 mm dia.Centrifugally cast (spun) iron socketed pipe as per IS: 3989.
142Making soak pit 2.5 m diameter 3.0 metre deep with 45 x45 cm dry brick honey comb shaft with bricks of class designation 75 and S. W. drain pipe 100 mm diameter, 1.8 m long complete as per standard designWith F.P.S. bricks
143Add Carriage Charges
144Sub-Head: Const. of Kitchen
145Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t
146Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
147Providing and laying cement concrete 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth
148Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
149Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
150Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
151Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
152Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
153Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with 1 : 1.5 : 3( 1 cement:1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
154Reinforced cement concrete work in shelves up to floor two level excluding cost of centering and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
155Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete.
156b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
157c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
158d) Lintels, beams, girders, bressumers and cantilevers etc.
159e) Column, pillars, posts and struts etc.
160Reinforcement of RCC work including bending, binding and placing in position complete.b) Cold twisted bars.
161Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).
162Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth.
163Extra for half brick masonry in superstructure above plinth level and up to floor two level.
164Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
165Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws.a) 38 mm thick best available local wood, class - B I
166Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws.a) 38 mm thick best available local wood, class - B I
167Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.b) Ornamental grill.
168Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 300 x 16 mm
169Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete.a) 300 x 10 mm
170c) 150 x 10 mm
171Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a) 125 mm
172Steelworkinbuiltuptubulartrussesincludingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately).
173ProvidingcorrugatedG.I.sheetroofingfixedwithgalvanisedironJorL hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpetwashers filledwith whiteleadcomplete,excludingthecost of purlins, rafters and trusses.(a) 0.63 mm thick GI sheet
174Providing ridges or hips 60 cm overall in plain G.I. sheet fixed with galvanised iron J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete.
175Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately).First floor
176Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling.a) Best local approved quality wood.
177Extra for chamfered edges in beading
178Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) including grouting the joints with white cement and matching pigments etc, complete.b) size of tiles 600x600mm
179Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 course sand) including grouting the joints with white cement and matching pigments etc, complete.b) size of tiles 600x600mm
180White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.
18112 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
182Painting two coats with oil type wood preservative of approved brand and manufacture on new work.
183Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
184Applying one coat of distemper primer of approved brand and manufacture on wall surface.
185Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give even shade
186Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade.
187Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).
188Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.
189Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.
190Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a) 15 mm nominal bore
191b) 20 mm nominal bore
192Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a) 15 mm nominal bore
193b) 20 mm nominal bore
194d) 32 mm nominal bore
195Providing and fixing brass bib cock of approved quality.a)15 mm nominal bore
196Providing and fixing brass stop cock of approved quality.a) 15 mm nominal bore
197Providing and fixing white vitreous china pedestal type (European type WC pan) water closet with seat and lid with CP brass hinges and rubber buffers, 12.5 Litres white vitreous china low-level flushing cistern with fittings and brackets 40 mm white porcelain inenamelledflushband,20mmoverflowpipewithspecialsandmosquitoproof coupling of approved municipal design complete including cutting and making good the walls and floors where required.a) WC pan with white plastic seat and lid.
198Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required.b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality.
199Providing and fixing 12.5 litres high level CI flushing cistern of approved make with integral fittings such as ball valve, bell, lever, GI chain and pull complete.
200Providing and fixing kitchen sink including making all connection excluding cost of fittings.a) White glazed fire clay sink size 600x450x150 mm
201Providing and fixing 100 mm sand cast iron grating for gulley, floors or nahni trap.
202Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.a) 100 mm dia
203c) 50 mm dia
204Providing and fixing sand cast iron heel rest sanitary bend.a) 100 mm dia
205Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.a) 100 x 100 x 100 mm
206Providing and fixing sand cast iron trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.c) 100 mm inlet and 50 mm outlet
207Add Internal electrification
208Add Carriage Charges
209ASSEMBLY SHED
210Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t
211Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
212Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
213Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
214Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
215Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete.
216d) Lintels, beams, girders, bressumers and cantilevers etc.
217e) Column, pillars, posts and struts etc.
218Reinforcement of RCC work including bending, binding and placing in position complete.b) Cold twisted bars.
219Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).
220Steelworkinbuiltuptubulartrussesincludingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately).
221ProvidingcorrugatedG.I.sheetroofingfixedwithgalvanisedironJorL hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpetwashers filledwith whiteleadcomplete,excludingthecost of purlins, rafters and trusses.(a) 0.63 mm thick GI sheet
222Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately).First floor
223Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling.a) Best local approved quality wood.
224Extra for chamfered edges in beading
225Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) including grouting the joints with white cement and matching pigments etc, complete.b) size of tiles 600x600mm
226Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).
227Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.
228Add Carriage Charges
229Entrance Gate with Guard Room & Boundary wall
230Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t
231Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
232Providing and laying cement concrete 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
233Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
234Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
235Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
236Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
237Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete.
238c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
239d) Lintels, beams, girders, bressumers and cantilevers etc.
240e) Column, pillars, posts and struts etc.
241Reinforcement of RCC work including bending, binding and placing in position complete.b) Cold twisted bars.
242Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).
243Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth.
244Extra for half brick masonry in superstructure above plinth level and up to floor two level.
245Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
246Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws.a) 38 mm thick best available local wood, class - B I
247Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 300 x 16 mm
248Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete.a) 300 x 10 mm
249Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a) 125 mm
250Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) including grouting the joints with white cement and matching pigments etc, complete.b) size of tiles 600x600mm
25112 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
252Painting two coats with oil type wood preservative of approved brand and manufacture on new work.
253Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
254Applying one coat of distemper primer of approved brand and manufacture on wall surface.
255Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give even shade
256Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade.
257Steel work riveted or bolted in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint.b) In Tees, Angles, Flats and Channels
258Add Internal electrification
259Add Carriage Charges
260BOUNDARY WALL
261Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t
262Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
263Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
264Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
265Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
266Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete.
267d) Lintels, beams, girders, bressumers and cantilevers etc.
268e) Column, pillars, posts and struts etc.
269Reinforcement of RCC work including bending, binding and placing in position complete.b) Cold twisted bars.
270Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).
271Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth.
272Extra for half brick masonry in superstructure above plinth level and up to floor two level.
273Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.b) Ornamental grill.
27412 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
275Applying one coat of distemper primer of approved brand and manufacture on wall surface.
276Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give even shade
277Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade.
278Add Carriage Charges
279Repairs & Maintenance including paiting works of existing school structure
280Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removalofstumps,roots,stacking of serviceable material with all lift sand up to a lead of 1000 mtrs and earth filling in the depression/pit.)(i) Girth from 300 mm to 600 mm
281Repairs to plaster in patches of 2.50 Sq.m. and under including cutting the patch to proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead.a) With cement mortar 1 : 4 (1 cement : 4 fine sand)
282Fixing door chowkhat in existing opening including embedding chowkhats in floor, cutting masonry for hold fasts, embedding hold fasts in cement concrete blocks with cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm shingle size), painting two coats of coal tar to sides of chowkhats and making good the damages to wall and floors complete including disposal of rubbish to thedumpinggroundwithin50 m lead.
283Fixing window chowkhats in existing openings including cutting masonry for hold fasts, embedding hold fasts in cement concrete blocks with cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm single gauge), painting two coats of coal tar to sides of chowkhats and making good the damge to walls complete including disposal of rubbish to the dumping ground within 50 m lead.
284Providing and fixing wooden cleats to doors and windows with approved fittings including removal of old cleats where necessary including painting, polishing or bees-waxing to match the existing shades.a) 1st class teak wood cleats with iron hinges and screws
285Supplying and fixing glass panes with putty and nails including removal of broken glass panes where necessary.b) Glass panes 3 mm thick and area 0.1 Sq.m. each
286Renewing wooden beams (not exceedng 4 m in length) in roofs including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 m lead.a) Timber Plank Class A - IV
287Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., completeb) Size of Tile 600x600 mm
288Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses.a) 0.80 mm thick GI sheet
289Extra for straight cutting and waste in CGI sheet roofing for making opening of area exceeding40 Sq.dm. for chimney stacks, sky lights etc.a) 0.80 mm thick sheet
290Providing and fixing 12 mm thick insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately)
291White washing with lime on old work to give an even shade.a) In two or more coats
292Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.
293Wall painting (one or more coats) with plastic emulsion paint of approved brand and manufacture on old work to give an even shade.
294Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
295Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade
296Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screwsa) Plain grill
297Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work.
298Painting two or more coats on GI sheets with superior ready mixed paint of approved brand and manufacture in white, grey or green shades on new work to give an even shade
299Painting one or more coats on GI sheets with superior ready mixed paint of approved brand and manufacture in white, grey or green shades on old work to give an even shade
300Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete
301Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a) 15 mm nominal bore
302Providing and fixing brass bib cock of approved quality.a)15 mm nominal bore
303Providing and fixing brass stop cock of approved qualitya) 15 mm nominal bore
304Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where requireda) Long Pan patten WC Pan
305Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x430x265 mm sizes respectively with CI automatic flushing cistern with fittings, RS or CI brackets standard size galvanized steel flush pipe and spreaders with brass unions and GI clamps complete including painting of cistern and fittings, cutting and making good the walls and floors where required.a) One urinal basin with 5 Litres CI automatic flushing cistern
306Providing and fixing kitchen sink including making all connection excluding cost of fittingsa) White glazed fire clay sink size 600x450x150 mm
307Add Carriage Charges

AI Tender Summary

OUR REF NO 45496977
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 21-10-2024
Authority
Authority Name Urban Development And Housing Department
Work Description Infrastructure Dev. Of Govt. Hr. Sec. School At Bana
Basic Detail
Tender No CEUD/PLG/MS-403/2023-24
Bidding Type Tender
Location
City East Kameng
State Arunachal Pradesh
Key Dates
Publish Date 12 Oct 2024
Submission Date 21 Oct 2024
Open Date 21 Oct 2024
Finance
Tender Value Ref. Documents
Tender Fee 5000
EMD 7.70 Lakhs
Exemption Not Available
Document List
c2b26c4f-eb0d-49e9-bc01-75f0a3c886c8.html
Tendernotice_1.pdf
BOQ_2084.xls
SBD.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 12, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 21, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 21, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 21, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

c2b26c4f-eb0d-49e9-bc01-75f0a3c886c8.html

pdf

Tendernotice_1.pdf

xls

BOQ_2084.xls

pdf

SBD.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender