Defence Government Departments Closing in 0 days TDR #45463057

Tender For Repair And Maintenance Of Damaged Indo Bangladesh B S Fence In Aor Of 172 Bn Bsf Under Shq Bsf Jowai

Issued by Government Departments · jowai, Meghalaya
Tender Value
37.93 Lakhs
Estimated cost
Bid Submission
05 Oct 2024
0 days left
EMD
75861
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jowai → Meghalaya
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair And Maintenance Of Damaged Indo Bangladesh B S Fence In Aor Of 172 Bn Bsf Under Shq Bsf Jowai

BOQ

Name of Work: Repair and maintenance of damaged Indo Bangladesh B S Fence in AOR of 172 BN BSF under SHQ BSF JOWAI
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
2Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
3Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish , lead up to 50 m and lift up to 1.5All kinds of soil.
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
5Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
6Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete
7Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
8Applying priming coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron steel works
9Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
10Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent designmix)
11Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
12Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead.
13Supplying and fixing turn buckles and straining bolts for barbed wire fencing. each
14Providing and fixing barbed wire of size 2.5mm x2.0mm type lows type (weight to be not less then 108 gms per meter length) conforming to I.S code to I.S code 278 duly dipped in anticorrosive bitumastic paint (average thickness 45 micron) fixing to the existing M.S angle iron posts placed at 3.m c/c in 23 horizontal rows (16 rows in vertical portion and 7 rows in slanting portion and strechd with M.S hooks/tighting bolts and also properly inter woven with two sets of cross diagonals as per drawing (one on vertical portion and other on slanting portion) with G.I barbed wire of same sepecification, fixing each row of barbed wire to intermidate angle iron post between tightening bolts with spilt cotter pins of size 5x22 (conferming to IS-549 steel), including providing vertical standard of G.Ibarbed wire of same sepecification properly inter woven with horizontal raw of barbed wire at 150 C/C spacing up to height of seven rows of barbed wire above ground level, each vertical strand adequately tied at three staggered place with G.I barbed wire not less than 16 gauge, applying three coat of alkyd zinc phosphate primer / paint approve brand and manufacture ( first coat of red oxide colour, second coat in grey colour and top coat in black colour) on tightening bolts, hooks & cotter pins, nuts washers & bolts, all as per direction of Engineer-in-charge,(b) India side Row
15Providing and fixing G. I. barbed wire, of size 2.5mm x 2.0mm type a lowa Type (weight to be not less than 108 gms per meter length), conforming to I.S. code 278 duly dipped in anticorrosive bitumastic paint (average thickness 45 micron) fixing M.S. angle iron posts placed at 3.0 m c/c in 9 horixontal rows and stretched with M.S. Hooks/ tightening bolts, and also properly inter woven with one sets of cross diagonals as per existing pattern or vertical pottion with G.I. barbed wire of same specification, fixing each rwo of barbed wire to intermendiate angle iron post between tighterning bolts with split cotter pins of size 5x22 (conforming to IS-549 steel), including applying three coat of alkyd zinc phosphate primer/paint of approved brand and manufacture (first coat in red oxide colour, second coat in grey colour and top coat in balck colour) on tightening bolts, hooks & coter pins. nuts washers & bolts, all as per direction of Engineer-in-charge.a) Middle Row (old Pattern)
16Providing and fixing barbed wire of size 2.5mm x2.0mm type lows type (weight to be not less then 108 gms per meter length) conforming to I.S code to I.S code 278 duly dipped in anticorrosive bitumastic paint (average thickness 45 micron) fixing to the existing M.S angle iron posts placed at 3.m c/c in 23 horizontal rows (16 rows in vertical portion and 7 rows in slanting portion and strechd with M.S hooks/tighting bolts and also properly inter woven with two sets of cross diagonals as per drawing (one on vertical portion and other on slanting portion) with G.I barbed wire of same sepecification, fixing each row of barbed wire to intermidate angle iron post between tightening bolts with spilt cotter pins of size 5x22 (conferming to IS-549 steel), including providing vertical standard of G.Ibarbed wire of same sepecification properly inter woven with horizontal raw of barbed wire at 150 C/C spacing up to height of seven rows of barbed wire above ground level, each vertical strand adequately tied at three staggered place with G.I barbed wire not less than 16 gauge, applying three coat of alkyd zinc phosphate primer / paint approve brand and manufacture ( first coat of red oxide colour, second coat in grey colour and top coat in black colour) on tightening bolts, hooks & cotter pins, nuts washers & bolts, all as per direction of Engineer-in-charge,(a) Bangladesh side Row
17Providing and fixing galvanized punched tope concertina coil, 1050 mm dia ( when closed weighting not less than 15.2 kg each coil, having galvanized spring cold drawn steel coil wire of 2.5 mm dia, galvanzied punched tope of low carbon steel having series of sharp barbs uniformly punched along its length having 550 nos of barbs on periphery per revolution and crimped on steel spring core wire having G.I steel wire handles hocked to coil for handing & M.S square bars hoocked with coil having pointed face anchorage, duly dipped in anticorrosive bitumastic paint, including spreading each coil uniformly in 10 metre length, including adequately tying to the existing G.I barbed wire fencing with G.I wire of not less then 16 gauge at every 1m spacing, tying the handles of succeeding coil with preceding coil with G.I wire for not less than 16 gauge, proper anchoring of spikes at start and end of the coil with C.C block of size 200 mm x 200 mm in C.C 1:2:4 ( 1 cement 2 coare sand 4 graded stone aggregate 20 mm nominal size )as par direction of Engineer-in-charge

AI Tender Summary

OUR REF NO 45463057
AUTHORITY Government Departments
TENDER VALUE 37.93 Lakhs
LAST DATE 05-10-2024
Authority
Authority Name Border Security Force
Work Description Repair And Maintenance Of Damaged Indo Bangladesh B S Fence In Aor Of 172 Bn Bsf Under Shq Bsf Jowai
Basic Detail
Tender No 29/BSF/FTR/Megh/2024-25
Bidding Type Tender
Location
City jowai
State Meghalaya
Key Dates
Publish Date 26 Sep 2024
Submission Date 05 Oct 2024
Open Date 07 Oct 2024
Finance
Tender Value 37.93 Lakhs
Tender Fee Ref. Documents
EMD 75861
Exemption Not Available
Document List
83d55f36-4293-4618-a0d1-eabf626cf309.html
BOQ_870039.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 26, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 07, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

83d55f36-4293-4618-a0d1-eabf626cf309.html

xls

BOQ_870039.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders