| 1 | S/F of 100Amp. 415V metal clad TPN HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect. |
| 2 | S/L of aluminim conductor PVC insulated armored, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by Engineer-In-Charge, complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. (i)185sqmm 3.5core |
| 3 | S/L of aluminim conductor PVC insulated armored, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by Engineer-In-Charge, complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 50sqmm 3.5core |
| 4 | S/L of aluminim conductor PVC insulated armored, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by Engineer-In-Charge, complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 25sqmm 3.5core |
| 5 | S/L of aluminim conductor PVC insulated armored, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by Engineer-In-Charge, complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 10sqmm 2core |
| 6 | Dismantling of Existing Damage 9.5 Meter Long steel tubular pole complete in all respects.(Only Labour Rate) |
| 7 | S/F of steel tubular pole 9.50 Meter long designated 410 SP-36 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respects. |
| 8 | S/F of 100mmX110mm shackle insulator /100mmx80mm pin insulator including G.I. bolts spindle nuts etc. complete in all respects. |
| 9 | S/F of 230mmx32mmx1.5mm galvanized steel strips including holes for shackle insulators pins and bolts etc. complete in all respects. |
| 10 | Supply and erection of ‘D’ clamps of 50mmx6mm flat iron on steel tubular poles/steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminum paint. |
| 11 | Dismantling of existing overhead line ACSR conductor from poles/service bracket complete in all respects (Only Labour Rate) |
| 12 | (627LR) Refixing of existing overhead line ACSR conductor from poles/service bracket complete in all respects (Only Labour Rate) |
| 13 | S/E of overhead line with ACSR conductor on poles/service bracket including binding etc. complete in all respects |
| 14 | Supply and erection of overhead line with G. I. wire No. 8 to 4 SWG on poles/ service bracket including binding etc. complete in all respects. |
| 15 | S/E of stay set at least 3.5 Meters away from the pole complete with galvanized 19 mm dia x 1.80 Meter long stay rod, 30cm x 30 cm x 6.3mm anchor plate, thimble stay clamps, stay insulator 19mmx600mm double screw tightener 7/3.15mm G.I. stay wire etc. in 1:3:6: cement concrete completein all respects. |
| 16 | Painting of the electric pole with 2 coats of aluminum paint over red oxide primer complete in all respects. |
| 17 | S/B of 600mm x 600mm x 6.0mm GI plate vertically for ear thing with its top at least 3 meters below ground level complete with 20mm dia G.I. pipe and funnel for watering and one ear thing leadof one no. 8 to 10 SWG GI wire in15mm dia G.I. pipe up to switch board (from apron to switch board the coast of G. I. pipe and GI wire will be extra) 30 cm square C.I frame with hinged cover masonry housing alternate layers of charcoal /coke and salt at least 150 mm thick all-round etc. as per directions of engineer-in-charge complete in all respects as per drawing (this will apply for ear thing of poles also) |
| 18 | S/fixing of one number 8 to 6 SWG G.I. Wire in 15mm dia. G.I. Pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sandlabour. T and P other material required for proper completion of the work as directed at site. |
| 19 | S/F of LED Street Light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 110 to 130 watt confirming to IP 66 Protection having company logo engraved complete in all respects including labourCat AAA, 12100 - 14300 system lumins high power LED with lenses, > 110 LM/watt, PF > 0.95, PHD<10% at full load, CRI>70, potted driver set not circuitory, face to face protection at 440 Volt and > 300 volt auto cut and restart feature, with 5 year warranty. |
| 20 | Cement concrete with 2 cm gauge grit, ballast approved coarse sand and cement in the proportion of 4:2:1 including suppy of all materials, labour and T&P etc. required for proper completion of work. |
| 21 | (App) S/F of LED street light potted driver set suitable for 110W to 130W complete in all respect. |
| 22 | (App) S/F of Surge Protection Device (SPD) for LED lights. |
| 23 | (1424LR) Labour charges for dismantelingof LED street light. |
| 24 | (1424LR) Labour charges for refixing of LED street light. |
| 25 | S/F of surface mounting round 24watt to 32 watt LED down lighter having powder coated die cast aluminium housing with extended heat sink, diffuser/reflector and driver set complete in all respects. Cat AAA |
| 26 | Providing and fixing of gun metal gate valve with CI wheel of approved quality 80mm nominal bore |
| 27 | Providing and fixing of 80mm dia MS pipe including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. |
| 28 | S/F of surface / flush mounting 4 ways SPN distribution board with additional metal door without MCBs complete in all respects and as directed at site. |
| 29 | S/F of 20 Amp. MCB (10KA) .c curve |
| 30 | S/F of 6 to 32 Amp. DP MCB (10KA) . |
| 31 | Supply and fixing of 32 Amp. 415 V metal clad S.P.N. rewireable type switch fuse unit on Angle Iron Bracket complete with all respects. |
| 32 | (Jal Nigam) Drilling of 150 mm dia T/W bore suitable for 110mm dia pipe/200mm dia T/W bore suitable for 140 mm dia pipe all complete with labour T/P as per direction of engineer incharge |
| 33 | (Jal Nigam) Supply and lowering of 110 mm dia 6kg/cm2 PVC pipe/140mm dia 10kg/cm2 with plastic net cover slots of pvc pipe by UPIN(phenolex or app by E/I) all complete (ISI mark only) SOR 2017-18 |
| 34 | (Jal Nigam) Supply and pouring of pee gravels suitable for T/W bore all complete as per direction of engineer incharge |
| 35 | (Jal Nigam) S/F of 110mm PVC pipe adopter |
| 36 | (Jal Nigam) Supply of 1HP submersible pump set with starter UPIN 65m head (Pluga/Crompton Greeves /KSB) |
| 37 | (Jal Nigam) Supply and fitting of 4sqmm 3 core copper wired cable (ISI mark) complete in all respect |
| 38 | (Jal Nigam) Supply and lowering of 40 mm dia ribbed screen Ashirvad PVC pipe (ISI marked)/ 32 mm dia G.I. Pipe by UPIN and fixed with boat site threaded SS nipple all complete. |
| 39 | (Jal Nigam) Supply and hosting of sintax or equivalent high density polythylene seamless of piece mould tank complete in all respect |
| 40 | (Jal Nigam) Transportation of all material T&P etc to the site of work, loading, unloading and proper stacking at the site including return cartage of unused material with the diging the pit of boring work including supply all labour T&P with with arrangement of water required etc all complete. |
| 41 | (Jal Nigam) Installation of 1.0 HP submersible motor pump with 32mm G.I. Lowering, submersible cable 4sqmm & installation of starter including supply of labpur, T&P etc complete in all respect |
| 42 | (Jal Nigam) Development of bore hole till the discharges of water become free from sand and turbidity by compression and disinfection of bore including supply of all labour T&P |
| 43 | (Jal Nigam) Chemical & bacteriological testing of water sample |
| 44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall- 15mm |
| 45 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall- 20mm |
| 46 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall- 32mm |
| 47 | S/L of 6 Sqmm 2 Core Al Conductor PVC insulated armoured sheathed cable 1100 Volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M. clamps etc. of suitable size or as directed the Engineer- incharge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |