Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-10-2024 | Corrigendum 1 | Other | 28-10-2024 |
| Sl. No. | Item Description |
| 1 | Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge.excluding earth work)Note : Providing and fixing of all requisite specials as perdrawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately |
| 2 | 200 mm dia |
| 3 | 300 mm dia |
| 4 | Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in- charge.(excluding earth work)Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 5 | 100 mm dia |
| 6 | 150 mm dia |
| 7 | 200 mm dia |
| 8 | 250 mm dia |
| 9 | 300 mm dia |
| 10 | 350 mm dia |
| 11 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specificationsand direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M.HDPE PE-100PN-6 |
| 12 | 75 mm dia |
| 13 | 90 mm dia |
| 14 | 110 mm dia |
| 15 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications anddirection of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. |
| 16 | HDPE PE-100 PN-6 |
| 17 | 125 mm dia |
| 18 | 140 mm dia |
| 19 | 160 mm dia |
| 20 | 180 mm dia |
| 21 | 200 mm dia |
| 22 | 225 mm dia |
| 23 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.For Laying Pipe |
| 24 | 900 mm dia 9 mm thick |
| 25 | 300 mm dia 8 mm thickness |
| 26 | Providing and applying following Coating to the External surface of MS pipes, including preparation of surface by cleaning as per ISO 8502-3/ SSPC-SP10/ NACE No.2 near white blast cleaning and abrasive blasting to a finish to SA 2.5 as per ISO: 8501-1 and surface profile / anchor profile of 50-75 / 75-100 microns as per ISO: 8503-2, including field joint coating at site complete as per Technical specifications and direction of Engineer –in-charge: 3 LPE (3 Layer Polyethylene) / DFBE (Dual Layer Fusion Bonded Epoxy)/ PU (Polyurethane)/ Polyolefin Tape coating . |
| 27 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water |
| 28 | Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification. |
| 29 | 300 mm Dia 8 mm thick casing pipe with protective coating. |
| 30 | 400 mm Dia 8 mm thick casing pipe with protective coating. |
| 31 | 1100 mm Dia 16 mm thick casing pipe with protective coating. |
| 32 | Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.Note: The rates for DI double flanged pipes shall be reduced 5%, if used other than OHSR pipes. |
| 33 | 100 mm |
| 34 | 200 mm |
| 35 | 300 mm |
| 36 | Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. |
| 37 | 100 mm dia |
| 38 | 150 mm dia |
| 39 | 200 mm dia |
| 40 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.For Pump Piping |
| 41 | 100 mm dia 6.0 mm thick |
| 42 | 150 mm dia 6.0 mm thick |
| 43 | 200 mm dia 6.0 mm thick |
| 44 | 250 mm dia 6.0 mm thick |
| 45 | 300 mm dia 6.0 mm thick |
| 46 | 600 mm dia 8.0 mm thick |
| 47 | 700 mm dia 8.0 mm thick |
| 48 | 800 mm dia 10.0 mm thick |
| 49 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc. |
| 50 | In all types of Soils |
| 51 | upto 1.5 m |
| 52 | In Soft Rock |
| 53 | upto 1.5 m |
| 54 | In Hard Rock (Blasting Probihited) |
| 55 | upto 1.5 m |
| 56 | Above 1.5 mtr and up to 3.0 mtr. |
| 57 | Filling with locally available river sand at all levels including wateringramming consolidating and dressing complete including cost of sand. |
| 58 | Lead for carring material for average 5 KM |
| 59 | Sand, bazri,ballast, kankar |
| 60 | Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers androlling every 3rd and top- most layer with power roller of minimum 8-10 tonne capacity and dressing up in embankment for roads, flood banks marginal banks and guide banks or filling up ground depressions, lead up to 50 Mtr. and lift up to 1.5 Mtr.:All kinds of soil |
| 61 | upto 1.5 mtrs |
| 62 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, FloatLP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside .Fasteners - CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem. Sluice Valves as per (IS: 14846 amended upto date) PN 1.6 ratings. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work |
| 63 | Class PN 1.6 |
| 64 | 40 mm dia |
| 65 | 50 mm dia |
| 66 | 80 mm dia |
| 67 | 100 mm dia |
| 68 | Class PN 2.5 |
| 69 | 200 mm dia |
| 70 | Providing, fabricating and fixing of MS air valve Tee with chamber on main ms pipeline for installation of tamper proof kinetic air valves. the work includes excavations and disposal of surplus soil,providing & fixing of 200 mm dia. MS pipe 10 mm thick as Tee, 1500mm mm nominal dia.10mm thick Ms pipe barrel with 2 No. 250mm nominal dia. as vent pipes & openable ms lid 1/3rd fix & 2/3rd made of 3 mm thick ms steal plate with all complete necessary weldings, stiffers fasteres as per enclosed GAD, inside & outside epoxy paint minimum of 250 micro thickness. |
| 71 | Construction of RCC air valve pillar including GI pipes, flanges, bend, MS clamps, rubber sheet, nut bolts/jointing materials etc in M-20 grade cement concrete of 2m height from Natural Ground Level in required shape and size as per approved drawing in all types of soils/rock disposing of surplus excavated materials within a lead of 50 m as per approved drawing complete including all charges at appropriate location in pipeline as per specification mentioned in the scope of work and as per direction of Engineer In Charge. M.S pipes and fittings of dia. |
| 72 | Glycerine filled pressure gauges (0-10 kg) |
| 73 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 |
| 74 | 80 mm dia |
| 75 | 100 mm dia |
| 76 | 125 mm dia |
| 77 | 150 mm dia |
| 78 | 200 mm dia |
| 79 | 250 mm dia |
| 80 | 300 mm dia |
| 81 | 900 mm dia |
| 82 | Class PN 2.5, Manually Operated with Gear |
| 83 | 300 mm dia |
| 84 | Providing, lowering, aligning, fixing in position in pipe line at work site, DID/FResilientseated(softseated)SluiceValves(GateValves), Vacuumtight(bubbletight),straightandpocketlessbodypassageof approved make of following class & dia complete confirming to BS-EN- 1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of gradeGGG40/GGG50 asper DIN1693 orGR SG- 400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date)/Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxypowder(EP-P)/ Fusion bond epoxy( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside,DrilledasperIS1538.Nut-Boltconfirmingto IS:1363andIS: 1367 (Galvanisedsteel)InsersionrubberofblackEPDM6mmthick. Suitablesupport structure as per directions of EIC, Sluice valves includingalljointing&jointingmaterial,labour,testingand commissioning along with pipe line as per Technical Specifications and as perdirectionofEngineer-in-charge.Note:Ratesareexclusiveoftail piece/ dismantling joints and earth work.Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 |
| 85 | 100 mm dia |
| 86 | 150 mm dia |
| 87 | 200 mm dia |
| 88 | 250 mm dia |
| 89 | 300 mm dia |
| 90 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as persite requirement and department direction\"scompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 |
| 91 | 80 mm dia |
| 92 | 100 mm dia |
| 93 | 125 mm dia |
| 94 | 150 mm dia |
| 95 | 200 mm dia |
| 96 | 250 mm dia |
| 97 | 300 mm dia |
| 98 | 350 mm dia |
| 99 | Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel)as per site requirement specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. |
| 100 | 80 mm dia |
| 101 | 100 mm dia |
| 102 | 125 mm dia |
| 103 | 150 mm dia |
| 104 | 200 mm dia |
| 105 | 250 mm dia |
| 106 | 300 mm dia |
| 107 | 900 mm dia |
| 108 | Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel)as per site requiredment specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 2.5 |
| 109 | 300 mm dia |
| 110 | 900 mm dia |
| 111 | 700 mm dia |
| 112 | 600 mm dia |
| 113 | 800 mm dia |
| 114 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amendedup to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/316 & shaft bearings-bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.PN 1.6 |
| 115 | 100 mm dia |
| 116 | 150 mm dia |
| 117 | 200 mm dia |
| 118 | 250 mm dia |
| 119 | 350 mm dia |
| 120 | Class PN 2.5 Manually Operated |
| 121 | 600 mm dia |
| 122 | Class PN 2.5, Motorised Operated |
| 123 | 700 mm dia |
| 124 | 600 mm dia |
| 125 | 800 mm dia |
| 126 | 900 mm dia |
| 127 | Construction ofValve Chamber in required size and shape as per drawing including required excavation of earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in chargeFor Class-AA loading |
| 128 | 1200 x 900 x1450 mm upto 150 mm |
| 129 | 1500 mm x 1200 mm x 1550 mm (upto 350 mm dia) |
| 130 | 2000 mm x 2000 mm x 2300 mm (800- 1000 mm dia) |
| 131 | Construction of RCC Junction valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as directed by Engineer-in-Charge. |
| 132 | Junction valve chamber of size 3220 mm x 2970 mm |
| 133 | Construction of Scour Valve Chamber in required size and shape as per drawing including required excavation of earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge |
| 134 | 1700 mm x 1500 mm |
| 135 | SITC of Bulk Flow Meter with removable mechanism class \"B\" confirming to ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and makingconnection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 136 | 80 mm dia |
| 137 | 100 mm dia |
| 138 | 125 mm dia |
| 139 | 150 mm dia |
| 140 | Construction of Village Transfer Chambers |
| 141 | GSM Modem for SMS Facility-24 V DC operated bulk flow meter to transmit reading of flow meter to LCC/MCC Centre |
| 142 | Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. |
| 143 | Bituminous courses |
| 144 | Granular courses |
| 145 | Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. |
| 146 | Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. |
| 147 | Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work. |
| 148 | M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 149 | Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. M20 Grade nominal mix (with graded stone aggregate 20mm nominal size) |
| 150 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 151 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation in basements rafts, footings, straps beams, bases of columns etc. up to plinth level. |
| 152 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost ofplastizers( if required) excluding the cost of centering, shuttering and reinforcement.M20 grade Nominal Mix / Design Mix |
| 153 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (\"Original producers\" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) |
| 154 | Shuttering |
| 155 | MS pipe specials above 600mm dia(with minimum 6.3mm thickness sheet) |
| 156 | MS Bearing Plate 8mm thick |
| 157 | MS Wearing Plate 8mm thick |
| 158 | Provision for Cathodic Protection from Nasirabad to SR-7 having TEMPORARY CATHODIC PROTECTION SYSTEM (TCP SYSTEM) & PERMANENT CATHODIC PROTECTION SYSTEM (PCP SYSTEM): |
| 159 | Surge Protection Devices having Supply, Erection & Commissioning of Air Vessel Based Surge Control System (Air Receiver, Sensor Shell, Butterfly valve, isolation valves, air compressor, Header assembly / pneumatic control assembly consist of valves,Pneumatic pipes, pressure gauges, specials etc, liquid level sensing devices, air chamber control panel, related fabrication works, civil work and other miscellaneous work required |
| 160 | Interconnection of 900 mm dia piepline with Existing CWR |
| 161 | Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications:Body-Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030,Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 420/ Gr 1.4021Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318- LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, Bearing Bush - Bronze IS:318- LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2.Insersion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied bothinside and outside . Suitablesupport structure as per directions of EIC including jointing & jointing material,labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge.Note: Rates are exclusive of tail piece/ dismantling joints and |
| 162 | Plunger Type Flow Control Valve100 mm dia |
| 163 | Removing & Re-fixing of Precast concrete interlocking blocks by manual, stacking of severciable & un serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block, all lead and lift as per general specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) |
| 164 | 100 mm thick |
| 165 | SITC DOLStarter type LT Panel of followingrating, all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thickduly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Baklight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Netural Links , Sprial , Saddle & Packing Material ) etc. complete as per Technical Specifications and as per direction of Engineer-In-Charge. |
| 166 | DOL STARTER2.2 KW(3 HP)- :For 2 motors (1 W+ 1S) I/C -MCB 25A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 30/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3)and O/G-MCB 16A ,TP, 10 KA, C Curve (2), Power Cont 9A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (4-6A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 2 Kvar (2) |
| 167 | Supply, installation, testing and commissioning ofMNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation ofPV module on MS frame as per approved design and drawings. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. andsuitable provision shall be included in tender document. |
| 168 | SITC of Local Push Button station fabricated with 16 SWG CRCA sheet, painted with polyster Powder coated finish after chemical treatment with Folliwng items and accessories:-i Shrouded Type push button with 2 NO Contacts element for Start/forward-reverse. ii Lockable Mushroom head type push buuton with 2 NC Contact element. iii 2.5 Sqmm clipon type terminals as requried with 20% spares.iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 169 | Local Push Button Station |
| 170 | Providing Household Tap Connectionas per technical specification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid seperately. |
| 171 | For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. |
| 172 | Add Extra onBOQ 50.01 for providingPP mechanical Integrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , not exceeding the flow of 7 LPM at 2 bar and a compression elbow, moulded in single piece/ fusion welded in place of electrofusion saddle piece and gun metal ferrule in case of HDPE pipe line.The job includes Installation of precast cement concrete block of size (80cmx75cmx10cm) below the tap for placing bucket/pot (Complete job) |
| 173 | For connection with 20 mm dia MDPE/PPR-C pipe length up to 05mtr. |
| 174 | P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore. |
| 175 | Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge. |
| 176 | Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. |
| 177 | Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement. |
| 178 | Provision for extension of Pump house for accomdating (3W+3S) proposed pump set at Rampura Pump House |
| 179 | Provision for New Pump house for accomdating (2W+1S) proposed pump set at Nasirabad Pump House |
| 180 | Provision for New Pump house for accomdating (2W+2S) proposed pump set at Baghsuri Pump House |
| 181 | Construction of Switch Room for the online booster pumpof size (3mx3m) at 1 locations on CD and VD as per approved GA drawing, scope of work and technical specification complete work in all respect |
| 182 | Providing, installation, testing, trial run and commissioning of Horizontal Centrifugal Split Casting pump the following, as per specifications |
| 183 | IPS-NASIRABAD TO GRAVITY SR-7 route278 LPS / 130 m head\" (2W+1S)/3.3KV/1500RPM/CACA/Horizontal) |
| 184 | Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 185 | IPS-BORADA TO IPS RAMSAR route76 LPS / 40 m head/75 KW (1W+1S) |
| 186 | IPS-RAMSAR TO IPS-RAMPURA TO SCL-03-CHANDSEN TO SCL-06-KURARI TO SCL-02-TILANA route28 LPS / 75 m head/45 KW (1W+1S) |
| 187 | IPS NASIRABAD TO CPS-NANDLA route44 LPS / 30 m head/30 KW (1W+1S) |
| 188 | IPS- NANDLA TO CPS-BAGHSURI route26 LPS / 40 m head/22 KW (1W+1S) |
| 189 | BITHOOR PS TO SCL-34-BITHOOR TO SCL-34-PACHMATA TO SCL-31-NAYAGAON TO SCL-33-ANSARI ROUTE-2 route19 LPS / 70 m head/30 KW (1W+1S) |
| 190 | BAGHSURI PS TO SCL-20-2-RASOOLPURA TO SCL-20-NAHARPURA TO SCL-29-BAGHSURI TO SCL-28-AJBA KA BARIYA SCL-28-DHOLADANTA ROUTE-1 route25 LPS / 65 m head/37 KW (1W+1S) |
| 191 | Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at syncronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. |
| 192 | 2.2 KW (3.0 HP) |
| 193 | 5.5 KW (7.5 HP) |
| 194 | 7.5 KW (10 HP) |
| 195 | 9.3 KW (12.5 HP) |
| 196 | 11.0 KW (15 HP) |
| 197 | 15.0 KW (20.0 HP) |
| 198 | 18.5 KW (25.0 HP) |
| 199 | Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and direction of Engineer In-Charge. |
| 200 | 100 mm dia |
| 201 | 150 mm dia |
| 202 | 200 mm dia |
| 203 | 250 mm dia |
| 204 | Class PN 2.5 |
| 205 | 600 mm dia |
| 206 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 207 | 100 mm dia |
| 208 | 150 mm dia |
| 209 | 200 mm dia |
| 210 | 300 mm dia |
| 211 | Class PN 2.5 |
| 212 | 800 mm dia |
| 213 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions,Face to face dimensions as per IS 5312 (part -1):2004Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brasswith EPDM/NBR \"O \"ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel)Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 214 | 100 mm dia |
| 215 | 150 mm dia |
| 216 | PN-2.5 |
| 217 | 600 mm dia |
| 218 | Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valave of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 219 | 100 mm dia |
| 220 | 150 mm dia |
| 221 | 200 mm dia |
| 222 | 250 mm dia |
| 223 | Construction of Flow Meter Chamber in required size and shape as per drawing including required excavation of earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge |
| 224 | Supplying, erecting, testing & commissioning of ElectricallyOperated Travelling Crane (EOT) .Main girder & End Carriagefabricated from Rollled Steel Section, Gear Box for all motion,Electro Magnetic Friction Disc Type Brakes, all safety limit switches,LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor ofadequate rating (KW), duly painted mechanical cleaning and onecoat of primer and two coat of synthetic paint and as per thedirection of the Engineer. |
| 225 | 20 MT Capacity Span upto 10 .5M and Lift upto10 M (specification mentioned in quotation) |
| 226 | Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: - |
| 227 | a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. |
| 228 | h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
| 229 | Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 |
| 230 | Rampura PS-11 |
| 231 | Baghsuri PS-14 |
| 232 | Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - |
| 233 | a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j) Providing and fixing water level indicator (float type). |
| 234 | k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
| 235 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II18 M Staging |
| 236 | 100 KL, staging Height 18 m |
| 237 | 150 KL, staging Height 18 m |
| 238 | 200 KL, staging Height 18 m |
| 239 | Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II20 M Staging |
| 240 | 150 KL, staging Height 20 m |
| 241 | Providing and fixing of flanged/ plain ended MS special of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depth in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. |
| 242 | MS pipespecialsup to600mmdia (withminimum5mmthickness sheet) |
| 243 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC,600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 244 | Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints. |
| 245 | SITC ofUltrasonic Level Transmitter suitable for measuring water levelin reservoir, powered by solar panel with minimum 48 power back up or internal installed battery ( 5 years battery life with replacement warranty), with out put as GSM/GPRS + data logger , Sensor Material: PP, accuracy +/_ 0.2 %,as per detailed Technical specification, scope of work and direction of Engineer in charge.Measuring range 0.0 to 6.0 mtr |
| 246 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). |
| 247 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. |
| 248 | Providing & fabricating steel reinforcement for R.C.C. work including cutting, bending, palcing in position and binding complete including cost of binding wire in foundations, Raft footing step Beams base of column etc. upto plinth level. Hot rolles deformed (IS:1139)cold twisted (IS:1786) bars. |
| 249 | TRANSFORMERS |
| 250 | Supply,Installation,Testingandcommissioningofcopperwound Transformers33/3.3KV,ThreePhase,50Hz,DYN11,ONAN type , Standard required accessories with ON LOAD tap changer(+5% to -10% instepsof2.5%),winding/Top---temperatureriseof45°C/40°C firstfilloil,havingpermissibletotallossvaluesnotexceeding7.5% of the maximum total loss values for 11 KV as per energy efficiency Level- 2atbasicInsulation levelconferming to IS2026 (Part- I to part - II), latest ammended and IS 1180 Part-I : 2014. Transformersdescribedasaboveandasperthefollowing continuous ratingwith R.T.C.C. & AVRPanel. |
| 251 | 1600KVA (33KV/3.3KV) |
| 252 | NGR CONTROL PANEL FOR 33KV/3.3 KV POWER TRANSFORMER |
| 253 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer3.3/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardrequired accessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in steps of2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISI marked drain valves, Dial type temperature gauge, first fill oil, Epoxy Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito |
| 254 | 100 KVA (3.3KV/0.433KV) |
| 255 | Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating |
| 256 | 160KVA |
| 257 | Supply,Installation,Testing&CommissioningofHTmetering cubicalpanelasapprovedByDISCOMsfabricatedoutof14SWG CRCAsheetsteelintwocompartment&MSangleofsize 60mmX6mm having provision for Following: (i) Provision for fixing Trivector Meter (To be supplied by DISCOMs) (ii)ProvisionforfixingofcombinedCTPTSet(Tobesuppliedby DISCOMs) (iii)TT Block (iv) 6mm Bakelite sheet on all sides. |
| 258 | Supply,Installation,testingandcommissioningof33KVDouble Pole structure with Air Break Switch having following specifications. a) DP : Double Pole structure made of two nos. 11 meter long PCC poles(400Kg)&7nos.MSChanneleachofsize100x50x6mm complete with earthing of the structure as perREC standardsin all respect with nuts, springs washers, clamps as required. b)GO:Offloadtypegangoperated3-poleHorizontaltypeswitch suitable for 33KV, 800A, 3phase central post rotating double break isolatorcompletewithMSHardware,coppermoving&fixed contacts,assemblyof9Nos.PostInsulators,GIpipeofsuitable length for operation. c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set / DropOutfuseset,33KVbarrelfusesmountedon6Nos.Post insulators. e) LA: 3 piece non linear resistor type lightening arrestor of approved make suitable for 3 wire, 33KV OH line with rated voltage 30KV rms &nominaldischargecurrentratingof10KA&completewith galvanizedclampingarrangement,GIbolts,nuts,washersetc.as required. e)Jumpers:3Nos.ACSRDogConductormountedonpintype insulators as required. The GO shall be operated by hand operated liverproperlyearthedwithprovisionforlockingmountedat3’. Completeaspertechnicalspecificationsand/orasdirectedby engineer. |
| 259 | Supply,Installation,testingandcommissioningof11KVDouble PolestructureWithAirBreakSWITCHhavingfollowing specifications : (a)DP : Double pole structure made of two nos. 9 meter long PCC poles(400Kg)&7nos.MSChanneleachofsize100 mmx50mmx2500mmcompletewithearthingofthestructureasperREC standardsin all respect with nuts, springs washers, clamps as required. (b) GO:Off load type gangoperated 3-polevertical flute typeswitch suitable for 11KV ; 400A ,3 phase, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assemblyof9Nospininsulator,GIpipeofsuitablelengthfor operation. c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set / DropOutfuseset,33KVbarrelfusesmountedon6Nos.Post insulators. (c)DO:3nosVertical/Horizontalmounted11kvhorngapfuseset /drop out 11kv barrel fuses mounted on 6no pin insulators (d) LA:3 piece non linear resistortype. lighting arrestor of approved make suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. (e)JUMPERS:3no11kvacsrconductorsmountedonpintype insularors as required. GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’ |
| 260 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction |
| 261 | 3C x 2.5 sq.mm |
| 262 | 4C x 2.5 sq.mm |
| 263 | 8C x 2.5 sq.mm |
| 264 | 19C x 2.5 sq.mm |
| 265 | 8C x 1.5 sq.mm |
| 266 | Supply, Installation, Testing and Commissioning of floor Mounted Indoor Type IC-OG 33 KV, 630A, 31.5 KA / 3 Sec. 33KV HT VCB Panel with AL. Bus bar. Comprising of 33KV FIXED TYPE VCB, 630A, 31.5 KA 3 sec. with associated Protection duly fabricated with 2.0/2.5/3.0 mm CRCA Sheet, Powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP4X. Incoming cum Outgoing facility (IC-OG). Suitable for Indoor & Outdoor Application (IP 5X).Suitable for 30000 Operation. This Panel having Voltage Presence Indications, Local/Remote switch, MFM with RS 485 communication, BCS, Digital Ammeter & Voltmeter, Phase, Spring Charge, Fault & trip Indications. Panel having Numerical Protection MF relay O/C, S/C & E/F Relay with RS 485 Communication Port & also required Under/Over Voltage & Current relay with anti-PumpingRelay facility in the panel, Master Trip Relay, Restricted Earth Fault Relay. Also provide the Suitable CT with CL 0.5, 15VA, Resin Cast, Dual Core, 1 Phase & the PT with CL 0.5 100VA/50VA As per Connections, Resin Cast , Fixed Type. Panel having transformers Protection Auxiliary Relays with 2 Elements for WTI, OTI & BZ. Panel having suitable Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure for easy Installation on floor with required Cable Trench & bottom side Cable Entry & Terminations. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB, s) & Indication are provided. All Protection Relays shall be PLC & SCADA compatible. |
| 267 | Supply, Installation, Testing and Commissioning of floor Mounted Indoor Type IC-OG 11 KV, 630A, 21 KA for1 Sec. 11KV HT VCB Panel with AL. Bus bar. Comprising of 11KV FIXED TYPE VCB, 630A, 21 KA 1 sec. with associated Protection duly fabricated with 2.0/2.5/3.0 mm CRCA Sheet, Powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP4X. Incoming cum Outgoing facility (IC-OG). Suitable for Indoor & Outdoor Application (IP 5X).Suitable for 30000 Operation. This Panel having Voltage Presence Indications, Local/Remote switch, MFM with RS 485 communication, BCS, Digital Ammeter & Voltmeter, Phase, Spring Charge, Fault & trip Indications. Panel having Numerical Protection MF relay O/C, S/C & E/F Relay with RS 485 Communication Port & also required Under/Over Voltage & Current relay with anti-PumpingRelay facility in the panel, Master Trip Relay, , Restricted Earth Fault Relay. Also provide the Suitable CT with CL 0.5, 15VA, Resin Cast, Dual Core, 1 Phase & the PT with CL 0.5 100VA/50VA As per Connections, Resin Cast , Fixed Type. Panel having transformers Protection Auxiliary Relays with 2 Elements for WTI, OTI & BZ. Panel having suitable Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure for easy Installation on floor with required Cable Trench & bottom side Cable Entry & Terminations. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB, s) & Indication are provided. All Protection Relays shall be PLC & SCADA compatible. |
| 268 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating: |
| 269 | 110VDC |
| 270 | SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%, 50 Hz , 1-ǿ / 3 -ǿ Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlas required of following rating: |
| 271 | 25 A + 25 A |
| 272 | PlateEarthingasperIS:3043withcopperEarthplateofsize 600mmx600mmx3.0mmbyembodying3to4mtr.belowthe ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C.finishedchambercoveredwithhingedtypewithlocking arrangementC.I.Cover,C.I.Frameofsize300mmx300mm completewithalternatelayersofsaltandcoke/charcoal,testingof earth resistance as required |
| 273 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mmx6.0mmbyembodying 3 to 4mtr.below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andC.C.finished chamber covered with hinged type with locking arrangement C.I.Cover,C.I.Frameofsize300mmx300mmcompletewith alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 274 | S & Laying following size earth wire/stripin horizontal or vertical run inground/surface/recessincludingriveting,soldering,saddles, making connection etc. as required. |
| 275 | 50mm x 6mm copper strip |
| 276 | 50mm x 6mm G.I. ( Hot Dipped) Strip |
| 277 | 32mm x6mm G.I. ( Hot Dipped) Strip |
| 278 | 25mm x 3mm G.I. ( Hot Dipped) Strip |
| 279 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage33 K.V.EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx150cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
| 280 | 3 core 240.0 Sq.mm |
| 281 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPE insulated33KVcable,withrequiredcomponents,preprationof cable ends, testing etc. as required of following sizes. |
| 282 | INDOOR |
| 283 | 3 core 240/300 /400 Sq.mm |
| 284 | OUTDOOR |
| 285 | 3 core 240/300 /400 Sq.mm |
| 286 | Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size. |
| 287 | 3 core 120.0 Sq.mm |
| 288 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
| 289 | Indoor |
| 290 | 3 core 120/150/185 Sq.mm |
| 291 | Outdoor |
| 292 | 3 core 120/150/185/225 Sq.mm |
| 293 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge. |
| 294 | 120 SQMM,3.5 core |
| 295 | 70 SQMM,3.5 core |
| 296 | 95 SQMM,3 CORE |
| 297 | 50 SQMM, 3 CORE |
| 298 | 35 SQMM, 3 CORE |
| 299 | 25 SQMM, 3 CORE |
| 300 | 16 SQMM, 3 CORE |
| 301 | 10 Sq.mm x 3 Core |
| 302 | 4.0 Sq.mm x 3 Core |
| 303 | 4.0 SQMMx 3 CORE |
| 304 | Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required. |
| 305 | Hot Dipped Galvanized |
| 306 | 450mm x 50mm x 2.0mm |
| 307 | Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required. |
| 308 | Hot Dipped Galvanized |
| 309 | 100mm x 50mm x 1.6mm |
| 310 | 150mm x 50mm x 1.6mm |
| 311 | 300mm x 50mm x 1.6mm |
| 312 | SFofrubbermattingwithonesidecorrugatedasperIS specifications 15652/2006 |
| 313 | 33 KV,30 mm thick, |
| 314 | 11 KV,25 mm thick, |
| 315 | 415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalcompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc. |
| 316 | Incommerfeeder(drowouttype)fortransformer630A/800A,50KA, ACB3pole,AlBusBars,DigitalMultifunctionmetercompatableto SCADA,metering,ProtectionCT\"s,IDMT3-O/C&1-E/F,indicating lamps,controlfuse,wiringetc.completeinallrespectofthesize appxo 900(D)X.2400(H)X1000(D) |
| 317 | Bus Coupler Feeder (drowout type ), 630/800 A ACB, 50KA, 3 Pole withoutreleasewithAlBusBars,IndicatingLamps,ControlFusesandwiringetc.completeinallrespect.Size:900(W)x2400(H)x 1000 (D) |
| 318 | 400 A MCCB Incomer (Fixed type )with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS, IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 319 | 250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D) |
| 320 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 321 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 322 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 323 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 324 | 400AMCCB(Fixedtype)asoutgoingCT\"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)X900(H)X1000(D) |
| 325 | 250AMCCB(Fixedtype)asoutgoingCT\"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)600(H)X1000(D) |
| 326 | MCCB up to 100A(Fixed type ) as outgoing CT\"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D) |
| 327 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. |
| 328 | 75KW |
| 329 | 45KW |
| 330 | 37KW |
| 331 | 30KW |
| 332 | 22KW |
| 333 | S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ControlMCBwithpanelwithallaccessorieswithfollowingrating |
| 334 | 7.5KW TO 9.3 KW |
| 335 | 15KW |
| 336 | 11KW |
| 337 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
| 338 | 433V APFC Panel in cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 339 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 340 | Local Push Button Station |
| 341 | SupplyanderectionofOctagonalpoleoffollowing lengthand dimensionas per table-3 withbaseplateon thecementconcretefoundationofM-15/M-20grade (1:1.5:3)withthehelpofanchorboltsofgrade6.8(IS 1367PIII).ThepoleshallbemadeofS-355JOgrade steelsheet,foldedlengthwisetoobtainedOctagonal shape,havingsinglelongitudinalseamweldandhot dippedgalvanisedinternally&externallyinaccordance withIS2629.Thepoleshallhaveaweatherproofflush doorandlockingarrangements.Thecompletework shallbesupervisedandcertifiedbythemanufacturers forsatisfactorysupply,erection,testingand commissioning. |
| 342 | 7 Mtr. |
| 343 | Supply,ErectionandFixingofhotdippedgalvanised Overhang (60 X 3.25 mm) with cap (250 x 137.9 x 4.05 mm) over the poles |
| 344 | Single arm overhang |
| 345 | P/FIP-65/IP-66protectedstreetlightluminarieson bracket / Arm.Fixturemadefrompowdercoated singlepiecepressurediecastaluminumhousingwith heat dissipation fins on housing with high power LEDs . Diffuser/glasscoverforensuringIP-65protectionfor lampandcontrolgearcompartment,systemlumen outputof100lum/watthighpowerLED.Integrated drivershallbehighefficiencyhavingefficiencymore than 85 % and in compliance to IEC standards. System lifeof50000burninghourswith70%ofinitiallumens maintained. Fixture shall be in CE compliance. IP-65 protected LED street light luminaries |
| 346 | LED street light fixture 80-90 watt |
| 347 | P&FIP-65protectedintegralfloodlightluminaire suitableforHPSV/Metalhalidelampcomprisingof powdercoateddiecastaluminiumhousing, electrochemicallybrightenedandanodizedstippled aluminium reflector, covered with suitably gasketed heat resistant and toughened glass, porcelain holder, integral controlgearboxhavingcopperballast,capacitor, electronicignitorprewiredwithpvcinsulatedcopper conductoruptoterminalblockincludingmaking connection testing etc. |
| 348 | 1 X 250 Watt |
| 349 | P&FHighpressuresodiumvapour/Highpressure mercuryvapour/Metalhalide/Halogenlampas required. HPSV tubular lamp normal output. |
| 350 | 250 Watt |
| 351 | Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 352 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D) |
| 353 | Heavy Duty suitable size of AL & CU Lugs, suitable size of Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, PG Glands, Anchor Fasteners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical, 4.5 Kg. CO2 type portable fire extinguisher, Fire buckets with floor / wall mounting stand, 11KV & 33KV Hand Gloves ect. Required hardware & accessories for Each Pump House. |
| 354 | 11 KV Switchyard Civil work for Transformers Foundation M25 Grade , GI Chain Link Fancying , MS Gate , 40mm Gravels, Earthing Chambers with Covers, Cable Trench for HT & LT with Pre-Cast Covers & Cable Tags & Markerect. |
| 355 | 33 KV Switchyard Civil work for Transformers Foundation M25 Grade , GI Chain Link Fancying , MS Gate , 40mm Gravels, Earthing Chambers with Covers, Cable Trench for HT & LT with Pre-Cast Covers & Cable Tags & Markerect. |
| 356 | DISTRIBUTION TRANSFORMERS SHIFTING FROM PH TO REQUIRED PUMP HOUSE. |
| 357 | Supply of indoor type floor mounted metal clad, incoming 3.3 KV VCB panel equipped with following switchgears and accessories. 3.3 KV digital type Voltmeter with selector switch for voltmeter and protection fuses/MCB for HT metering up to 7 KV on incomers, Ammeter digital type with selector switches for ammeters. Set of dual core dual ratio 3CTs of suitable ratio with sec of 1 A of 15 VA burden and accuracy Class –0.5 for metering and class 5P10 for protection, Multifunction Meters with RS 485 communication.Incomers up to 630 Amp. VCB, Fixed Type, 21KA for 1 Sec, with associated Protection duly fabricated with 2.0/3.0 mm CRCA Sheet, Powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP4X. This Panel having Local/Remote switch, BCS, Phase, Spring Charge, Fault & trip Indications. Panel having Numerical Protection MF relay O/C, S/C & E/F Relay with RS 485 Communication Port & also required Under/Over Voltage & Current relay with anti-PumpingRelay, Restricted Earth Fault Relay facility in the panel, Master Trip Relay. Panel having suitable Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure for easy Installation on floor with required Cable Trench & bottom side Cable Entry & Terminations. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB, s) & Indication are provided. All Protection Relays shall be PLC & SCADA compatible. FOR INCOMERS |
| 358 | Supply of indoor type floor mounted metal clad, incoming 3.3 KV VCB panel equipped with following switchgears and accessories, Incomers up to 630 Amp. VCB, Fixed Type, 21KA for 1 Sec, with associated Protection duly fabricated with 2.0/3.0 mm CRCA Sheet, Powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP4X. This Panel having BCS, Phase, Spring Charge, Fault & trip Indications. FOR BUS COUPLER |
| 359 | Supply of indoor type floor mounted metal clad, incoming 3.3 KV VCB panel equipped with following switchgears and accessories. 3.3 KV digital type Voltmeter with selector switch for voltmeter and protection fuses/MCB for HT metering up to 7 KV on incomers, Ammeter digital type with selector switches for ammeters. Set of dual core dual ratio 3CTs of suitable ratio with sec of 1 A of 15 VA burden and accuracy Class –0.5 for metering and class 5P10 for protection, Multifunction Meters with RS 485 communication.Incomers up to 630 Amp. VCB, Fixed Type, 21KA for 1 Sec, with associated Protection duly fabricated with 2.0/3.0 mm CRCA Sheet, Powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP4X. This Panel having Local/Remote switch, BCS, Phase, Spring Charge, Fault & trip Indications. Panel having Numerical Protection MF relay O/C, S/C & E/F Relay with RS 485 Communication Port & also required Under/Over Voltage & Current relay with anti-PumpingRelay, Restricted Earth Fault Relay facility, Motor Protection Relay in the panel, Master Trip Relay. Panel having suitable Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure for easy Installation on floor with required Cable Trench & bottom side Cable Entry & Terminations. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB, s) & Indication are provided. All Protection Relays shall be PLC & SCADA compatible. FOR OUTGOINGHT MOTORS |
| 360 | Supply of indoor type floor mounted metal clad, incoming 3.3 KV VCB panel equipped with following switchgears and accessories. 3.3 KV digital type Voltmeter with selector switch for voltmeter and protection fuses/MCB for HT metering up to 7 KV on incomers, Ammeter digital type with selector switches for ammeters. Set of dual core dual ratio 3CTs of suitable ratio with sec of 1 A of 15 VA burden and accuracy Class –0.5 for metering and class 5P10 for protection, Multifunction Meters with RS 485 communication.Incomers up to 630 Amp. VCB, Fixed Type, 21KA for 1 Sec, with associated Protection duly fabricated with 2.0/3.0 mm CRCA Sheet, Powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP4X. This Panel having Local/Remote switch, BCS, Phase, Spring Charge, Fault & trip Indications. Panel having Numerical Protection MF relay O/C, S/C & E/F Relay with RS 485 Communication Port & also required Under/Over Voltage & Current relay with anti-PumpingRelay facility, Restricted Earth Fault Relay in the panel, Master Trip Relay. Panel having transformers Protection Auxiliary Relays with 2 Elements for WTI, OTI & BZ. Panel having suitable Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure for easy Installation on floor with required Cable Trench & bottom side Cable Entry & Terminations. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB, s) & Indication are provided. All Protection Relays shall be PLC & SCADA compatible. FOR OUTGOING DISTRIBUTION TRANSFORMERS |
| 361 | 3.3 KV HT FMCA Digital Soft Starter Panel with Motor Protection Relay &Reactor for min 557 KW HT VT Motor ,--Indoor Type, Metal enclosed compartmentalized, Short Circuit withstand & duration (Sec.) - 9kA for 1Sec, Rated 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X, Control & Protection Supply - 110VDC, 10KV for 1min power frequency, 2 Pole Vacuum Contactor 400A, Bus Bar - Copper, FMCA Coils type - Air Core as per IEC 60076-6,Insulation - Class F, Temp. rise limited to class B. Coil material - Copper conductor is wound on Fiberglass bobbin, No of Tapping’s - 5 nos., Single Power cable Based. Soft starters shall be FCMA type as per IEC-60076-6 standard (or IS 5553 Part-3) designed, manufactured and tested at manufacturer’s works to ensure smooth and reliable operation for the site conditions. Staring current shall be limited to 3.0 to 3.5 times the full load of the motor with power factor improvement capacitors and shall reduce it to less than 3.0 Ifl if motor torque speed and pump torque speed allows so. The three phase windings of the FCMA Soft Starter shall be made of copper insulated winding with insulation class F and Max. Temperature of winding shall be limited to that of class B. FCMAplus Soft Starter coils should be air core type air Cooled and mounted in dust and vermin proof panel suitable for indoor mounting. The three phase coils must be separately available for repairs in future. Each coil must be wound on epoxy bobbin. Making a common epoxy casting for three coils is strictly not acceptable since it avoids thermal dissipation and also any repair to one coil makes all the three coils assembly useless. All coils should be vacuum pressure impregnated. Vendor should demonstrate temperature rise test- Motor starting current i.e. DC currentof amplitude equal to (Motor full load current x 3.5) shall be injected into all three coils for duration of 2 consecutive start time (2 x starting time). Temperature will be monitored by the temperature sensors embedded inside the coil. Temperature rise shall be less than Class B as per specification, Starting of motor shall be from either Soft Starter panel located near to motor or shall be from PLC.Necessary wiring diagram shall be provided, considering staring interlock, trip circuit, staring and running mode signal and terminated suitably. Design calculation must be submitted along with the tender. Manufacturer must also design the winding such that maximum temp rise after the two consecutive starts should be less than ‘class B’. Design calculation for temp. rise must be submitted. Suitable Thermistor / RTD should be embedded in to all 3 windings with digital temperature scanner for protection. There should be audio-visual alarm in case of the temperature of soft starter coils are higher or any such soft starter failure. Bypass Vacuum Contactor shall be closed, when the Motor starting current is reduce to Motor no load current (Motor has reached the full speed), PLC provided shall monitor the starting current continuously and PLC shall give the bypass command once the motor current reached the motor no load current, i.e closed loop control arrangement for bypass switching. Manufacturer must provide a Current transducer to sense the starting current and monitoring leakage current after the bypass is switched ON. Current transcoder shall sense the leakage current and trip the Main VCB. |
| 362 | 3.3 KV/ min 350 KVARHT APFC Panel for 557KW HT Motor ,- 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X,Control & Protection Supply - 110VDC, Connection - Line side ( Shunt Connection) , Air Cooled, Bus Bar 400A Copper, Metal enclosed compartmentalized.PF improvement for HT motors for a targeted PF of 0.95 lag to be provided.Each bank shall be rated for KVAR rating at 3.3KV with 0.2% series reactors. The inductance value will control amplitude and frequency of the inrush current at back-to-back switching. Over-current & Earth fault protection: Over current and earth fault Protection to cover bus faults between the capacitor banks and its controlling circuit breaker. Combination of two IDMT relays having 50-200% settings and one E/F relay of IDMT characteristic with 20-80% setting shall be used with suitable current transformer.ii. The HV capacitors connected on HV bus shall discharge through directly connected discharge device from the residual voltage value to 50 volts or less within 5 minutes after the capacitor is disconnected from the source of supply.iii.HT Capacitors for transformers shall be protected against over current by means of suitable breaker with adjustable over current relays, which are adjusted to interrupt the circuit, when the current exceeds the permissible limit. The impregnate should be non-PCB (NPCB). Voltage rating of non-PCB capacitor is to be suitable for better life.a. The reactor should be air cooled dry type aluminum wound. The reactor shall be suitable for Indoor duty and the Inrush Current Limit coil shall be connected on Line. The reactors shall be suitable to carry 130% of the rated current of the capacitor bank. Series reactor coils shall be air cored coils.b. The reactor shall be duly insulated with insulation, vacuum pressure impregnated to withstand the rated voltage. Insulation class F. The maximum temperature of reactor shall be limited to that of Class B. The reactor modules must be all weather and vermin proof epoxy coated.HRC Fuse – 1. Nominal System Voltage: suitable for capacitor Application. 2. Applicable standard IEC 60282-1 (IEC 282-1). 3. HRC fuse links should have a zone between the minimum melting current and the minimum breaking current where the fuse links can fail to interrupt.ISOLATORS -The PF capacitor panel shall comprise of 1 No. of HV suitable rating 25 kA for 1 sec, 3-Pole off-Load type manually operated Isolator Switch. |
| 363 | Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPE insulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes . |
| 364 | 3 core 120/150/185 Sq.mm |
| 365 | 3 core 240/300 Sq.mm |
| 366 | 3 core 120/150/185/225 Sq.mm |
| 367 | Providing & Laying XLPE insulated as per IS:7098/II/85H.T.cable as per PWD specification for electrical Works for working voltage 3.3 K.V.(UE)inexistingRCC/Hume/Stoneware/PVCpipe/open duct/cabletrenchwithfillingofexcavatedearthintrench,on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size as per points (a), (b), (c) mentioned below:-(a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I (b)conductorshallhaveelectrolyticaluminiumconfirmingtoIS 8130, IS 3975-1999for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c)OEMMusthaveISO9001&14001certificationsforquality assuarance&itsowninhouseNABLlabsetupforalltesting facilities forcables .All above as per pre approved by Engineer in charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure \"A\" attached with this BSR . |
| 368 | 3.3KV (UE) , 3 core 240.0 Sq.mm |
| 369 | 3.3KV (UE) , 3 core 185.0 Sq.mm |
| 370 | 3.3 KV (UE) , 3 core 185.0 Sq.mm |
| 371 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI –92 num DO – 92 num AI –16 num AO – 8 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 30 num Selector Switch - 15 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer – 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 30 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 372 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 76 num DO – 76 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 15 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer – 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 1 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 373 | Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheet completewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 60 num DO – 60 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 10 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer- 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 20 num Wiring + TB etc – 1 lot Hardware – 1 lot |
| 374 | HIM Display, Colour, 12\" having Ethernet Port, USB Port ect. |
| 375 | Operator cum Engg. StationPC includes,Corei5processor,8GB DDR-3RAM,1TBSSD,DVDRWDrive,RS-232/485Ports,1ParallelPort,4nos.USBPort,2x EthernetCards,Keyboard,opticalmouse,32\"\"LED monitor, Latest Original window, MS Office, Anti Virus ect.Make - HP/DELL/ LENOVA |
| 376 | Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface. |
| 377 | Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank. |
| 378 | 1 KVA |
| 379 | 2KVA |
| 380 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelArmouredoverallPVCsheathed(ST-1) overallscreenedCoreArmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 381 | 1 SQMM, 24 Core |
| 382 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 383 | 1 SQMM, 2 Pair |
| 384 | ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction. |
| 385 | 4C x 2.5 sq.mm |
| 386 | 4C x 1.5 sq.mm |
| 387 | Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66 |
| 388 | 0-5M |
| 389 | Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2\"NPT(M)/Accuracy:0.15%Protection: IP67 |
| 390 | 1/2\" M (NPT) |
| 391 | Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material ofsensorandotherwettedparts:SStype316,Housing:Diecast aluminum,Switchtype:Microswitch,Repeatability:±1%ofspan, Switch Contacts: 2 NO + 2 NC |
| 392 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum |
| 393 | Modular RTU complete with DI, DO, AI and modbus communication ports and power supply 12/24 VDC or for variable power supply using batteries, rechargeable batteries, solar or 10.8 V DC to 28.8 V DC with integrated modem; connection to control center via Communicationprotocols,on-board I/Os min. (4 DI, 2 DQ, 2 AI), configuration and diagnostics per webinterface,RJ45port,mobilecommunicationsantenna (GSM/UMTS),MiniSIMcard,withadapterMicroSIMcardalso, GPRS (Multi-slot Class), 35 mm DIN rail mounting, TCP/IP, Open VPN-Client. Panel Enclosure for Modular RTU Location, wall/floormountedalongwithwiringandrelatedaccessoriesand arrangement of mounting of RTU, Modem having IP-5X Protection. |
| 394 | Programming and Troubleshooting software for RTUs |
| 395 | Supply, installation, testing and commissioning ofMNRE approved off GridSolar Panels with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS fabricated structure 120 micron hot dip galvanized iron , showing arrangement of panel in available space and installation ofPV module of minimum 15W-20W on frame structure. The Frame Structure needs to be mounted on top of Water Tank such that minimum height of lower edge of panel shall be 0.5 Mtr from top of Water Tank to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be bolted. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr. The system should include a 12V Battery Charger with over charging protection, surge protection & auto cutoff facility including a 12V Battery of minimum 7-10AH capacity. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structureandsuitable provision shall be included in tender document. |
| 396 | Supply, installation, testing and commissioning of GSM /GPRS/ Cloudbased data transmitter for Bulk Flowmeter (woltman Magnetic Pulse Output only ), Battery Powered -3VDC to12VDC ,Model no- CT-DL-V1.0-100784, battery life 3-5 Years, Inbuild Memory fuction upto 2gb micro SD card supportedto stroe the data in the absense of availabe mobile network,(1 no Data transmit in aday on cloud system), Encloser- ABS Protection-IP67/68,Operating tempreature -50-55 Deg. C. The VTC Inlet Flow Data shall be transmitt to the Respective MCC ROOM. |
| 397 | 1.5 Tons Split Type Air Conditioners with auto switch over circuit. |
| 398 | LocalDataLogger-PCbasedDataAcquisitionSystemwithSAM WILicenseSoftwaresuitableforStoring,Logging,Reporting, PrintingdatafromaboveofferedAnalysers.PCwithspecifications asunder:PentiumDualCore2Processor,2GBRAM,250GB HDD,CD/DVDComboDrive,19\"TFTMonitor,2serial&1parallel ports, Standard WINDOWS, Operating System,standard keyboard, mouse with pad and Color Laser printer. |
| 399 | CentralDataLogger-PCbasedDataAcquisitionSystemwithXR PremiumLicenseSoftwaresuitableforStoring,Logging,Reporting, Printingdata,Validationandcommunicatingwithabove offeredLocalDAS.PCwithspecificationsasunder:PentiumDual Core 2 Processor, 2 GB RAM, 250GBHDD, CD/DVD Combo Drive, 19\"TFTMonitor,2serial&1parallelports,Standard WINDOWSOperatingSystem,standardkeyboard,mousewithpad and Color Laser printer. |
| 400 | UPS, Capacity 5 KVA, 230 VAC, 50 Hz. with 1 hr battery backup for all the Analysers only |
| 401 | SITCof55\"\"FlatScreenHDLEDTVwithremotecontrolandwall mountunit/floorstandcompletewithmakingconnectionsetc.as required Sony/ Samsung/Panasonic) |
| 402 | Cost for basic service charges, Administration and Management, running of office, staff quarters, comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, IEC activities as per scope of work, cost of material required for maintenance & repairs, cost of lubricants, saltf for producing chorine, consumables spare parts (if the spare parts supplied to PHED are used in emergency) as per scope of work & items & conditions of contract no, amt will be paid for O&M in DLP |
| 403 | For the 1st year of O&M after DLP |
| 404 | For the 2nd year of O&M after DLP |
| 405 | For the 3rd year of O&M after DLP |
| 406 | For the 4th year of O&M after DLP |
| 407 | For the 5th year of O&M after DLP |
| 408 | For the 6th year of O&M after DLP |
| 409 | For the 7th year of O&M after DLP |
| 410 | For the 8th year of O&M after DLP |
| 411 | For the 9th year of O&M after DLP |
| 412 | For the 10thyear of O&M after DLP |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy