| 1 | Supply and fix in repairsthe following fittings for street light complete all specified and as directed as under :-Make - Philips/Crompton Greaves/ Havells |
| 2 | (a)Ballast for HPSV/MH - 400 Watts |
| 3 | (b)Ballast for HPSV/MH - 250 Watts |
| 4 | (c)Metal halide lamp 400 Watts |
| 5 | (d)Metal halide lamp 250 Watts |
| 6 | (e) Ignitor for HPSV/MH lamp |
| 7 | (f) capacitor 33/42 mfd |
| 8 | (g) Porcelain holder E40 type |
| 9 | Excavation in trenches not exc. 1.5 m wide and not exc.1.5 m deep for laying of cable, pipe and for erecting of steel tubular swaged pole etc, and getting out in hard/dense soil complete all as specified and directed. |
| 10 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 11 | Removing excavated material not exc 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting points in soil all as directed by Engineer-in-Charge. |
| 12 | Spreading and compacting of riddled earth obtained from trenches for cable ducts / trenches for cable cushion on both top and bottom of cable, including ramming complete as specified and directed by Engineer-in-Charge.(Note :- Punned thickness only will be measured) |
| 13 | Supply and laying burnt bricks for cable protection of sub class \"B\" standard size in trenches complete as specified and directed |
| 14 | Grass cutting near MES E/M installation under GE Tvl, area as directed by Engr-in-charge, manually or using grass cutting machine complete all as specified and directed.Note : Payment for Grass cutting machine and necessary T & P including POL will be deemed to be included in the unit quoted rate. |
| 15 | Trimming of trees, touching LT/HT OH line, of girth upto 63mm and depositing upto 50 mtr distancecomplete all as specified and directed.Note : Payment for tree cutting machine and necessary T & P for tree cutting will be deemed to be included in the unit quoted rate. |
| 16 | Supply and laying/erection steel water tubing galvanised medium grade 50mm for light fixing complete all as specified |
| 17 | Supply and laying steel water tubing galvanised light grade 50mm for protection of cable complete all as specified |
| 18 | Supply and laying LT UG cable, 1100 volts grade, XLPEinsulated and sheathed, armoured, multistranded, heavy duty electric cable with aluminium conductor laid in trenches, ducts, on poles, walls, through pipes etc complete for the following sizes including cable glands on both side terminations where necessary etc., complete including taking down the existing cable all as directed.Note: Earthwork, excavation, sand cushioning and cable protection shall be measured andpaid for seperately. |
| 19 | (a) 2 core 6 Sqmm |
| 20 | (b) 2 core 10 Sqmm |
| 21 | (c) 4 core 10 Sqmm |
| 22 | (d) 4 core 16 Sqmm |
| 23 | Supply and fix Post top lantern fitting LED type with 40 Wattmade in cast aluminium spigot housing with decorative opal acrylic diffuser and IP 65 protection including 3 core flexible conductor cable for light connection all as specified and as directed. |
| 24 | Supply and fix LED flood light luminarie, 100 W, 12000lumen output with toughned glass and individual LED with secondry lens optics with IP 66 ingress protection, 4 KV inbuilt surge protection with lumen efficiency 120 lm/W, made out of pre die cast housing, with manufacturers name embossed in body including 3 core flexible conductor cable for light connection complete all as specified and directed. |
| 25 | Supply and fix LED flood light luminarie, 200 W, 12000lumen output with toughned glass and individual LED with secondry lens optics with IP 66 ingress protection, 4 KV inbuilt surge protection with lumen efficiency 120 lm/W, made out of pre die cast housing, with manufacturers name embossed in body including 3 core flexible conductor cable for light connection complete all as specified and directed. |
| 26 | Supply and fix LED street light luminarie, 45 W, with presmatic polycarbonate modular secondry lens optics with IP 66 ingress protection, 4 KV inbuilt surge protection with lumen efficiency 120 lm/W, made out of pre die cast housing, with manufacturers name embossed in body including 3 core flexible conductor cable for light connection complete all as specified and directed. |
| 27 | Supply and fix LED street light luminarie, 60 W, with presmatic polycarbonate modular secondry lens optics with IP 66 ingress protection, 4 KV inbuilt surge protection with lumen efficiency 120 lm/W, made out of pre die cast housing, with manufacturers name embossed in body including 3 core flexible conductor cable for light connection complete all as specified and directed. |
| 28 | S & F in repairs search light 400 W, high intensity long range wather & dust proof with highly polished stainless steel reflector toughned frontglass recessed on the flanged of the body, Aluminium housing, focussing arrangement, fitted with MS cradle and bolts, suitable for fixing on roof with arrangement of verticle and horizontal operation control from inside including control box and its associated wiring, fixing arrangement complete all as specified and directed. |
| 29 | Supply and fix in repairs 32 mm dia light grade GI tube bracketof length 1.2 mtr, bend to required shape including MS clamp made out of30 mm x 6 mm MS flat ironandfix on steel tubular poles with necessary GI bolts, nuts and washers - 2 sets for each fittings complete set all as specified and directed by Engineer-in-Charge. |
| 30 | Supply and fix street light timer distribution box of suitable size by sheet metal enclosure factory made pre fabricated for outdoor installation with 40 Amp MCB TPN including provisioning with analog/astronomical timer of 24 hr dial with 32 Amp contactor, with IP 54 degree of protection complete all as specified and directed. |
| 31 | Supply and fix LED bollard with opal acrylic diffuser floor mounted 9 W,warm white, 3000 K, IP 66 degree of protection including excavation, foundation and PCC work complete all as specified and directed. |
| 32 | Supply and fix in repairs 3 pole power contactor, MNX 40 type, AC 440 Volts, 3 phase, coil voltage 440 volts, 40 Amps in the existing street light control switch boxcomplete all as specified and directed. |
| 33 | Supply and fix in repairs 3 pole power contactor, ML3 type, 40 Amp, AC 440 Volts, 3 phase, coil voltage 440 volts, 40 Amps in the existing street light control switch box complete all as specified and directed. |
| 34 | Supply and fix Analog/digital Timer Switch with 24 hrs timing type with current capacity 16 A complete all as specified and directed |
| 35 | Supply and fixing IP 66 modular box made of FRP / inpact resistance plastic & heat resistant materialsof size 205x255x112 mm, connector terminal block 4 pole 16 A capacity including 06 Amp MCB SP and fixing to the street light or post top light pole with suitable sizes of clamps, nuts and bolts complete all as specified and directed. |
| 36 | M & L for preparing surface ofsteel tubular poles,9/11 mtr long with cross arms, clamps etc and applying one coat of aluminium paint incl numbering the poles with white colour paints over black back groundetc complete all as specified and as directed by Engr-in-Charge. |
| 37 | Material and labour forproviding cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate cast in situ asin copings and the like including weathering, slightly rounded or chamfered or chamfered angles as directed including use of form work as necessary complete all as specified and as directed. |
| 38 | M & L for PCC 1:4:8 type D2 with 40 mm Cement concrete in foundations,filling and mass concrete complete all as specified and as directed. |
| 39 | Trenchless boring of road, pavement, hard standing without damaging outer surface including making good distrubed surface with cement mortar complete all as specified and directed.. |
| 40 | M & L for checking, testing for serviceability of street light/ flood light at Pole, removing oxide from contacts of OH/ connectors, refresh the connection of street light supply, replacement of connecting cable including checking serviceability, changing of time of street light timer as per specified with respect to seasons, checking for fault of UG cable/ OH/ light fitting with help of required tools all as specified and directed. |