Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #45385036

Tender For (A) Spl Repairof Bldg No P-2/01 To 08 (Or Md Accn) Atrobert Barrack ( Grover Enclave) Of Mh Jabalpur (B) Provision Of 63 Kva Gen Set (Silent Type) For 1 Wts, 10 Mtr Air Rifle & Pistol Range, It & Officers Of 1 Mtr , 1Stc Jabalpur(C) Provn Of 0

Issued by Statutory Bodies & Commissions/Committees · jabalpur, Madhya Pradesh
Tender Value
83 Lakhs
Estimated cost
Bid Submission
21 Oct 2024
0 days left
EMD
1.49 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jabalpur → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

(a) SPL REPAIROF BLDG NO P-2/01 to 08 (OR MD ACCN) ATROBERT BARRACK ( GROVER ENCLAVE) OF MH JABALPUR (b) PROVISION OF 63 KVA GEN SET (SILENT TYPE) FOR 1 WTS, 10 MTR AIR RIFLE & PISTOL RANGE, IT & OFFICERS OF 1 MTR , 1STC JABALPUR(c) PROVN OF 01 X 100 KVA SILENT DIESEL GENR SET FOR RECORD OFFICE COMPLEX (BLDG NO P-254) OF JAK RRC(d) PROVN OF 01X125 KVA DG SET AND ALLIED SERVICES WITH CONNECTIVITY ALONGWITH SHED FOR POWER BACKUP OF TECH LABS & SIMULATOR LABS FOR AGNIVEER IN1 STC UNDER GE (WEST) JABALPUR.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Oct-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-Oct-2024
2 16-Oct-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-Oct-2024

BOQ

Name of Work: (a) SPL REPAIROF BLDG NO P-2/01 to 08 (OR MD ACCN) ATROBERT BARRACK ( GROVER ENCLAVE) OF MH JABALPUR (b) PROVISION OF 63 KVA GEN SET (SILENT TYPE) FOR 1 WTS, 10 MTR AIR RIFLE & PISTOL RANGE, IT & OFFICERS OF 1 MTR , 1STC JABALPUR(c) PROVN OF 01 X 100 KVA SILENT DIESEL GENR SET FOR RECORD OFFICE COMPLEX (BLDG NO P-254) OF JAK RRC(d) PROVN OF 01X125 KVA DG SET AND ALLIED SERVICES WITH CONNECTIVITY ALONGWITH SHED FOR POWER BACKUP OF TECH LABS & SIMULATOR LABS FOR AGNIVEER IN1 STC UNDER GE (WEST) JABALPUR.
Sl. No. Item Description
1Taking down cement plaster etc on brick walls/ concrete (ceiling) surfaces of any descriptions including racking out joints, hacking for keys, scrubbing down with water and disposal of unserviceable materials to out side of MD land complete all as specified & directed.
2M&L for 15mm thick rendering in CM ( 1:6) oninternal surfaces of wall, finished even and smooth without using extra cement complete all as specified & directed.
3M&L for rendering 15 mm thick in cement mortar (1:4) on external surfaces of wall, mixed with liquid water proofing compoundas per manufacturer\"s instructions and finished the surfaces even and smoothwithout using extra cement completeall as specified and directed(Note:Liquid WPC will be measured and paid separately as \"supply only\".)
4Demolition of cement concrete of any description (unreinforced) in ground floors and paving not exceeding 15 cm in thickness (below or above ground level) including removal of debris to out side MD land complete all as specified & directed.
5M&L for 25 mm thick cement concrete(1:2:4) Type B-0, using 12.50 mm gradedcrushed stone aggregate as in sub-basecomplete all as specified andas directed.
6M&L for non skid ceramic coloured joint free tiles , area of each tile exceedeing 0.18 sqm but n.exc 0.38 sqm (600x600), as in vertical surfaces such as skirting / dado etc,set and jointed in neat cement slurry and pointed in white cement, laidover and including 10 mm thick backing in CM (1:4)complete all as specified and directed.
7M&L for non skid ceramic coloured joint free tiles, area of each tile exceedeing 0.18 sqm but n.exc 0.38 sqm (600x600), in floors, set and jointed in neat cement slurry and pointed in white cement, laidover and including 15 mm thick screed bed in CM (1:6)complete all as specified and directed.
8M&L for joint free non skid ceramic colouredtiles 7 to 8 mm thick(square / rectangular) area of each tile exc 0.11 sqm and not exceeding 0.18 sqm in floors etc, set & jointed in neat cement slurry and pointed with white or coloured cement to match with the shade of tiles, laidover and including 15 mm thick screed bed in CM (1:6)complete all as specified and directed.
9Material and labour forGlazed ceramic tiles of size 350x 250x 7mm/ 450X 350X 7mm thick in vertical surfaces such as dado/ skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles, laid over and including 10mm thick rendering in CM 1:4complete all as specified and directed.
10Taking down Chowkhats or frame with shutter (without taking off shutter from the frame) area n.exc 1.50 sqm each and removal complete all as specified & directed.
11Taking down Chowkhats or frame with shutter (without taking off shutter from the frame) area exc 1.50 sqm but n.exc 4 sqm each and removal complete all as specified & directed.
12S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or weldedcomplete all as specified and directed.
13S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete withoutglazing bars, dovetailed or weldedcomplete all as specified and directed.
14M&L for IInd class (Indian Sal, Bijasal, Hollock or Benteak) hardwood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified & directed.
15M&L for mild steel work conforming to Fe-290 Gde -165 as in hand rail, holdfast,half round or other steel section or core for wooden hand rail strait portion, drilled and countersunk for balusters running bars for doors, nosing to steps including embedingin concrete and screwing etc, wind ties for roof including securing bolts, posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified and directed.
16M&L for factory made second class (Indian Sal, Bijasal, Hollock or Benteak) hardwood glazed and skeleton shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) and fitted to chowkats complete all as specified & directed.Notes:- (i) glazing will be measured and paid for separately. (ii)Butt hinge will be measured and paid for separately .
17S&F 30mm thick flush shutters, solid core construction with block board core and plywood face panels commercial type on one face and other side covered with decorative face veneer with liping/frame to match complete all as specified.( Note : The unit rate quoted by the Bidder is deemed to include for provision of suitable blocks for taking mortice locks, latches , or other fittings)
18S&F, 1mm thick wood grain printed PVC sheet fixed or laid on to flush doors by using rubber used adhesive, supplying & fixing at site as per specification
19Supply & fix 300mm long aluminium alloy, anodised sliding door bolts with hasp & staple (bolt type) & fixing clips of sheet, cast or extruded section and fixing bolts & sliding bolts of extruded section or cast aluminium alloy complete all as specified & directed.
20Supplying & fixing 300mm size ordinary rat tail rod pattern springs of mild steel including roller and roller plate complete all as specified & directed.
21Supplying & fixing 100mm size butt hinges, extruded aluminium alloy with galvanized mild steel hinge pin, anodized, type C-21 complete all as specified & directed.
22Supplyand Fixaluminium handles 150mm size, cast type, anodised complete all as specified & directed.
23Supply and fix 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified & directed.
24S&F in repair 18 mm thick ply , PVC sheetcoloured Prelaminated on one side with approved texture as in kitchen cabinet ( with shelves and partition ) including necessary fittings & fixtures as per manufacturer\"s instructionscomplete all as specified and directed
25S&F continuous (piano) hinges, mild steel bright finish or electro galvanised width of flaps (when open)30mm complete all as specified and directed.
26S& F for Solid PVC mouldeddoubledoor frame of size 50mm x 95mm made out of 5mm Plain colour PVC sheet reinforced with M.S. tube, suppling & fixing in opening but single prelam PVC sheet used instead of Plain colour PVC sheetcomplete all as specified and as directed
27S&F Factory Made Solid PVC Moulded Door Shutters with wood free EPS 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face with particle board core, supplying & fixing in frame at sitecomplete all as specified and as directed
28Taking up or down steel tubing and connections, including cleaning for refixing or removing to store of size 15mm bore of pipe complete all as specified and as directed.
29Taking up or down steel tubing and connections, including cleaning for refixing or removing to store of size 20mm bore of pipe complete all as specified and as directed.
30Taking up or down steel tubing and connections, including cleaning for refixing or removing to store of size 25mm bore of pipe complete all as specified and as directed.
31S&F 25mm bore tubes medium grade galvanized with all fitting such as socket, elbow, Tee tee, union and short length etc. and fixed complete to walls and ceilings or laid in floors of any length all as specified and directed by Engr-in-charge.
32Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorsfor 16mm bore of pipe including Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor and all necessary fittings etc complete all as specified and directed.
33Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorsfor 20mm bore of pipe including Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor and all necessary fittings etc complete all as specified and directed.
34S&F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160mm complete all as specified and directed.
35S&F in repair PVC low level flushing cistern of capacity 10 litres complete with siphon handle, lever, float valve and PVC bend including connecting to ITWC/ ETWC, PVC connection 450 mm long and fixing on wall bracket completeall as specified and directed by Engr-in-charge.
36Stainless steel plate rack, 0.56mm thick of standard pattern, 31”x36” size including fixing to wall with 4 Nos 50mm long screws & PVC rawl plugs complete all as specified.
37S & FDoor Seal rubber etc, complete all as specified and directed.
38S&F PVC bath cabinet with mirror of size 400x500mm ofapproved colour complete all as specified & directed.
39S&F in repair 5 mm thick looking mirror 600 x 450 mm selected quality glass mounted on 6 mm thick commercial plywood, with aluminium beading and fixed to wall with brass screws, cups and washers complete as specified and directed.
40S&F in repair vitreous China squatting pan of pattern Orissa Pattern , size 580 x440 mm white with P or S trap , front or backinlet and integral foot rests any pattertn (excl flushing cistern and flush pipe) complete incl provn of lime concrete bedding connection to flush pipe , trap etc & making good complete all as specified and directed
41S&F vitreous china wash basin white flat back size 550 x 400mm excluding taps, waste, chain & plug and porcelain stopper but including brackets, PVC connections 450 mm long all as specified and directed by Engr-in-charge.
42S&F in repairbrass chromium platedshower rose 125 mm size with or without swivel joint complete all as specified and directed.
43S & F in repair 15 mm bore brass chromium plated Wall Mixture three in one including Provn of OH shower fancy type screwed down to GI pipe with CP brass cup complete all as specified and directed.
44S & F in repair 15 mm bore brass chromium plated Wash Basin Mixture for hot & cold water with long shank and fly nut complete all as specified and directed.
45S & F in repair 15mm bore brass chromium plated stop cock/angle cock fancy type long body with CP brass cup and screwed down to GI pipecomplete all as specified and directed.
46S&F in repair 15mm bore bib tap fancy type chromium plated long body cast copper alloy screwed down for iron pipes or for brass ferrule complete all as specified and directed by Engr-in-charge.
47S&F in repair stainless steelwire cloth 0.36 mm nominaldia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples beads or in steel/wooden window complete all as specified and directed by Engr-in-charge.
48S&F Soap Dish,Chromium plated fancy type with brass screws and wooden/plastic cleats complete all as specified and all as directed.
49Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats(Minimum weight 300gms).
50S&F 3mm thick sheet glass ordinary quality and galzing with oil putty or wooden beads in squares of any size complete all as specified and directed by Engr-in-charge.
51S&F 3mm thickfigured glass pin head type and glazing with oil putty or wooden beads in squares n exc 0.50 Sqmtr each pane complete all as specified and directed by Engr-in-charge.
52S & F for CP Towel Ring as approved by GE, fixed in repairs, complete all as specified and directed.
53S&F brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and directed.
54M & L forGranite (Black/Ruby Red ) work (table rubbed and polished)20 mm thick in cooking platforms includingedge moulding & cutting holes for gas pipe through drill machineand jointed with grey cement slurry and pointed to match withthe shade of granite stone including grindingand polishing, laid over andincluding screed bed 15 mm thick in CM 1 : 6etc all complete.all as specified and as directed.
55M&L for rounding to edges ofgranite stone slabs one edge, such as in cooking platform, and other similar situations complete all as specified and as directed.
56M&L for machine cut cudappahstone slab as in cooking platform/ shelf , 20-25mm thick over & including 15mm thick cement screed bed in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to matchwith the shade of the slab including rubbing andpolishing complete all as specified & directed.
57Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, head, shoes, bends, swan-necks atc., includingcleaning or refixing or removal to store (measured overall as fixed along the centre line over fittingsand accessories) complete all as specified & directed
58S&F, PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in wallscomplete all as specified and directed.
59S&F, in repair PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in wallscomplete all as specified and directed.
60S&F PVC (SWR) bends ISI marked any radius of 110 mm borewithaccess door complete all as specified and directed.
61S&F PVC (SWR) bends ISI marked any radius of 75 mm borewithaccess door complete all as specified and directed.
62S&Fin repairs PVC (SWR) junction single, (single T) equal or un equal of 110 mm bore of pipe complete all as specified and directed
63S&Fin repairs PVC (SWR) junction single, (single T) equal or un equal of 75 mm bore of pipe complete all as specified and directed
64M&L 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in floor sub base and finished even and fair completeall as specified and directed.
65M&L for Machine pressed precast cement concrete rubber moulded interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, laid over and including 50mm thick sand cushioning completeall as specified and directed.
66M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate, 75mm thick in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed.
67M&L for PCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses etc and similar work including necessary form work complete all as specified and directed.
68M&L for Precast Reinforced cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 complete all as specified and directed.( Note : Reinforcement shall be measured and paid for separately against relevant items of this BOQ.)
69M&L for mild steel TMT bars10 mm dia and overas in reinforcement for concrete, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
70M&L for Complete removal of existing water proofing treatment from roof and providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberanecomprising of the following for Non approachable roofs-(i)Cleaning and sweeping and washing down with water to remove all dust etc from plastered roof surfaces / walls and filling of crack with sealing compound etc(ii)Bituminous based primer conforming to IS: 3384 – 1965 @ 0.3 Kg/Sqm (iii) One layer of super thermo APP modified water proofing memberane with non polyester reinforcement . (iv)3mm thick and minimum Weight @3.50Kg/Sqm,laid with gas torch and pasted on roof surfaces with roller. The over laps shall be sealed by flame including vertical surface after cutting necessary grooves and making good with PCC gola 1:2:4 type- B1 etc adhere to bitumen all as per manufactures instructions. (v)Applying two coat of aluminium paint @ 0.20 Kg / Sqmover bituminouspolymeric membrane as per manufacturer instruction . ( (Note : Application including sides lap,over laps shall be provided not less than 10 cm and joint sealed with torch as per manufactureer\"s instructions.)
71M&L for 10mm thick screed bed or bedding layer in CM (1:3) mixed withliquid water proofing compound as per Manufacturer\"s instructions,on concrete roof surface, finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed ( Note : Liquid WPC shall be measured & paid for separately as \"Supply only\".)
72S&F fancy type draphery rods with two way wooden/brass brackets 20-25mm bore cut to length as reqd of colour as selected , approved by GE & as directed by Engr-in -Charge.
73S&Fmild steel framed work such as grills,gratings etc with ends of bars shouldered and/ or riveted,or forged into spikes, framed guard bars and similar work conforming to Fe- 290 ( Gde-E-165)complete all as specified and as directed.Note: The unit rate quoted by contractor is deemed to be inclusive of cutting to dead lenth where required, notching, drilling, fitting, rivetting and/or welding or connecting with bolts and nuts (including rivets or bolt and nuts).No claim whatso ever shall be entertained by Govt on this account.
74Dismantling of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles complete all as specified and directed.
75M&L for brick work with sub class \"B\"fly ash bricks, straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified & directed.
76Cutting holes in brick walls, Exc. half brick but not exc. one brick in cement mortarfor inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 TypeB-1 as required complete all as specified & directed.
77S&F PVC connection 15mm size with brass nuts of length 450mm all as specified and directed by Engr-in-charge.
78S&F Chromium plated mild steel hat pegs, solid body, 175mm to 250mm, complete all as specified & directed.
79M&L for preparation of new surfaces of iron/ steel of any description over 10 cm width or girth and applyingtwocoat of synthetic enamel paintover a coat of red oxide primer as approved by GE complete all as specified & directed.
80M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coat synthetic enamel paint of colour as approved by GE over and including a coat of pink primer complete all as specified & directed.
81M&L for preparation of old painted surfaces of wood or wood based materials of any description over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified & directed.
82M&L for preparation of old painted surfaces of steel of any description over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified & directed.
83M&L for preparing new plastered or un-plastered surfaces of walls and applyingtwo coats ofoil bound distemper with 2 mm thick wall care puttyin two layers over a coat of chalk whitining on walls complete all as specified and directed.
84M&L for preparation of old decorated surfaces of walls by complete removal of existingtreatment and applyingtwo coats ofoil bound distemper over 2mm thick birla wall care putty on walls in two layerscomplete all as specified and directed.
85M&Lfor applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and directed.
86M&Lfor complete removal of old painted surface applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over oldsurfaces. complete all as specified and directed.
87Preparation of old surfaces of ceiling and applying two coats of white wash completeall as specified and directed.
88M&L for preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
89Surface excavation n.exc 30cm deep and averaging 15cm deep and getting outin soft /loose soil.complete all as specified and as directed.
90Excavation over areas, n exc 1.5m deep & getting out and getting out in Soft/loosesoil complete all as specified and directed.
91M & L excavation in post holes (or similar holes) each n. exc 0.5 cum, getting out in soft/loose, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
92Removing excavated material (soil) obtained from excavation to a distance100 metre and depositing where directed at a level not exceeding 1.5 meter above the starting point.
93M & L moorum filling in floors or pavings, laid in layers n exc 15 cm thick , spread, levelled and rammed including wateringcomplete all as specified and directed..
94M&L for Hardcore of guage n exc 63mm of broken stone aggregate, deposited,spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
95M&L 100 mm thick PCC 1:2:4 ,Type B2 ,using 40 mm graded aggregate as in paving /path, finished fair and even complete all as specified and directed.
96Supply and fix rolled mild steel sections conforming to Fe- 410-W (Gde E-250) quality-A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails & guides for sliding doors, fixed with angle cleats or other connecting plates etc complete all as specified & directed.
97S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
98S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe- 290 (Gde E-165) complete all as specified and directed.
99M&L for 20 to 25 mm dia mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,not exc 30 cmlong complete all as specified & directed.
100S&F of pre-painted galvalume aluminium zinc coating GI based 0.50mm thick(AZ-150) plain steel sheet of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip and straight flashings (length & girth as fixed) fixed with self tapping screws complete all as specified & directed.
101S&F of pre-painted galvalume aluminium zinc coating GI based 0.50mm thick(AZ-150) plain steel sheet of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip and straight flashings (length & girth as fixed) fixed with self tapping screws complete all as specified & directed.
102M&L for mild steel work conforming to Fe-290 Gde E-165 as in hand rail, holdfast,half round or other steel section or core for wooden hand rail strait portion, drilled and countersunk for balusters running bars for doors, nosing to steps including embedingin concrete and screwing etc, wind ties for roof including securing bolts, posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified and directed.
103M & L for preparation of new or previously untreated surfaces of steel of any description, n.exc 10cm in width or girth whenunconnected with other painting or when painted in a different tint and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed..
104M&L for prepration of new plastered surfaces of walls and applying two coats of cement base paint over & including a coat of cement base primer complete all as specified & directed.
105Taking down carefullyany typepoint wiring (light, fan, socket bell or power) , complete with fitting such as switches ceiling roses,lamp holders sockets,regulators,call bell light fitting with PVC conduit surface /concealed or wooden pattens including sunken cast iron /pressed steel terminal boxes etc completeall as specified and directed by Engineer in charge.
106Taking down carefully Main switch and Distribution boards any make and size completeall as specified and directed by Engineer in charge.
107Taking down the ceiling fan in situ repairing overhauling painting fans and refixing it after rectifying all defectscomplete all as specified and directed.
108Taking down carefully Old unserviceableany typesub main wiring with wooden batten/PVC surface conduit of any sizecomplete all as specified and directed by Engineer in charge.
109M&L for provision of sub main wiring with tworuns of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 25mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 6 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed.Notes:- (i) Finished sub main wiring withtworuns of 6.0 sqmm cable & one run of 6 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid as one unit length.(ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.(iii) Colour coding for wiring/ bus bar/ main connection shall be followed .
110M&L for provision of sub main wiring with tworuns of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 4 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed.Notes:- (i) Finished sub main wiring with tworuns of 4.0 sqmm cable & one run of 4 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid as one unit length.(ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.(iii) Colour coding for wiring/ bus bar/ main connection shall be followed .
111M&L for Point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor cable 1100 volts grade drawn into and including concealed PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of antirorrrosive paint outside and two coats of aluminium paint inside, 2.8mm thick hylam brand laminated white bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer in charge.
112One light point/Bell point controlled by one switch 5/6 Amp.
113One fan point controlled by one switch 5/6 Amp.
114One socket point controlled by one switch 5/6 Amp on same board.
115One socket point controlled by one switch 5/6 Amp on Independent board.
116Description all as per item No 111 here in beforebut with 1100 volts grade copper standard conductor cable of size 2.5 Sqmm with 2.5 Sqmm solid copper conductor PVCfor 3 pin switch socket outlet15 Amp on independent board complete all as specified and directed by Engineer in charge .
117S & F in repair forbell ding dong AC 230 voltssingle pole one way complete all as specifiedand directed by Engineer in charge.
118S & F in repair for Switchpiano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed by Engineer in charge.
119S & F in repair for Socket outlet 3 pin,5 Amps andAC 230 volts flush type complete all as specified and directed by Engineer in charge
120S & F in repair for switch socket combination3 pin5 and 16 Amps AC 230 volts flush type complete all as specified and directed by Engineer in charge
121S & F in repair for Ceiling rose surface bakelite 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified and directed by Engineer in charge
122S & F in repair fan regulator Step typeof polycarbonate complete all as specified and directed by Engineer in charge.
123Supply anf fixingin repairLED lamp rotary type/holder type of 12 watt complete all as specified and directed by engr-in-charge.
124Supply and fixing in replacement of decorative wall light fitting WITH LAMPS 9 WATTmade up of Polycarbonate , City-1 , Cylindrical shape , with LED lamp 9 Watt complete with fixing arrangements on wallcomplete all as specified and directed.
125Supply & Fixing Smart bright Batten Series, LED luminaire using LED 22 watt 110 Lumens/watt with diffuser which ensures uniform distribution and comfort, batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminium housing, Energy efficient, Flicker free start Inbuilt driver unit, Suitable for wall and ceiling mounting using bracketswith and including the luminairetesting on completion as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl),complete all as specified and directed.
126S & F, in repair, LEDDecorative /mirrorlight fitting12 watt along with fixtureSurface mounted suitable for indoor aplication , connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three coreflexibleflexible copper conductor cable suitable size complete all as specified and directed by Engineer in charge.
127S&F in repair Bulk head endura LED light fitting complete with10 watt LED and making necessary electric connection to ceiling rose with copper conductor of suitable size & length complete all as specified & directed.
128Supply & fix in replacement ofLED Security Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos ofpole fitting clamps made out of MS flat , nutsand boltsand painting with aluminium paint. complete all as specified and as directed.
129S&Fin replacement of sheet steel enclouser distribution boards, double door factory madeTPN 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulatedcopper jumpers of suitable sizeof suitable rating all as specified and directed.
130S & F MCB TPN 25 to 63 Amps, 240 Volts, minimum 10 KA, \"C\" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed . (Note :- Proper and suitable size cable copper lugs to be fixed with MCBs are included in unit rate of each MCB of any rating)
131Supply and fixingSingle phaseceiling fan1200 mm permanent magnet brushless DC(BLDC) Motor 230 v 50 Hz single phase 26-30watt rated current 0.16 amp,pf 0.98 370/360 rpm air delivery 220m3 rated service value 629m3/min/watt no of blades three type of blade leaf 1.05 mm thick aluminium sheet remote control radio frequency 5 speed +off timer option speed regulation class of insulation two nos bearings including connecting wire complete with all as required and directed at site by eng in charge.
132Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 8 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.
133S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed.
134S & Ffor MCB Single pole rated capacity 5 to 40 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed.
135Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed.
136M&L for earthing complete with galvansided steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron wire 4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15mm bore GI pipe medium grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear including 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth wire alongwith protection pipe and testing on completion complete all as specified and directed.Note:- GI wire and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
137S & F, in repair, bell push piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed by Engineer in charge.
138Supply and fixingSingle phase propeller type ventilating ( Exhaust fan) heavy duty AC 230 volts 300 mmsweep, metallic body complete with Metaliclouversincluding making holes of suitable size and making good the disturbed surface and shutters including electric connection with pvc flexible twin core copper wire from ceiling rose to Exhaust fan,nut & boltcomplete all as specified and as directed.
139Supply and fixingSingle phase propeller type ventilating ( Exhaust fan) heavy duty AC 230 volts 300 mmsweep PVC body complete , including making holes of suitable size and making good the disturbed surface and shutters including electric connection with pvc flexible twin core copper wire from ceiling rose to Exhaust fan,nut & boltcomplete all as specified and as directed.
140Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 25 sqmm, 4 core including jointing materials such as cable glands & lugs etc Complete all as directed.
141Supply,laying & fixing Double Wall Corrugated (DWC) pipes made of High Density Polyethylene (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc..complete allas specified and asdirected , outer dia50 mm andinner dia 38 mm, complete all as specified and directed
142Dismantling of water tank of any description of capacity exc. 500 litres but not exc. 1000 litres, removing to store or from the site complete all as specified and as directed.
143Supply and fix500 ltrs capacity rotational moulded polyethylene water storage tank double layered (cylindrical vertical with closed top), ISI Marked,hoisted and fixed in position complete all as specified & directed.
144S & F ball brass valve high pressure with polythene float and flynut complete, screwed for iron ferrule and fixed of size 20 mm completeall as specified and directed
145Supply and fix Gun metal globe/gate valve, with iron wheel head, screwed both ends for iron pipe and fixed of size 20 mm dia completeall as specified and directed
146Supply & fix 15mm bore medium grade galvanised steel tubes with all fittings and fixed complete to walls and ceilings or laid in floor complete all as specified & directed.
147Supply & fix 20mm bore medium grade galvanised steel tubes with all fittings and fixed complete to walls and ceilings or laid in floor complete all as specified & directed.
148Supply and fix Bib taps Chromium plated with crutch or butterfly handle, screwed down, fancy typescrewed for iron pipe or for brass femule and fixedcomplete all as specified and directed
149Supply, installation, testing and commissioning static silent (Sound proof enclosure) Diesel Engine Driven Generating set capable of delivering 46.8 KW (58.5 KVA output), at prime mover rating at 0.85 load factor as per ISO-8528 (Part-I), 415 Volts (AC three phase, 4 Wire system of supply) 50 Hz at 0.80 minimum power factor. The DG set shall consist of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with AMF control panel standardized by Manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe including all mounting accessories as required/ suitable for installation at 1MTR,1STC Jabalpur (MP) complete including, anti vibration pads, including all features to comply with latest CPCBIV + emission compliant norms/guidelines and comprising of the followings: Note:-Capacity of engine, alternators shall be worked out after taking all derating factors into consideration.
150(a) ENGINE (prime mover): Diesel engine 1500 RPM, direct injection, minimum 3 cylinders, in line with Mechanical governer, engine, well designed air handling system with dry type, replaceable paper element air cleaner with restriction inductor, air to air after cooling, optimised turbocharger for increased altitude capabilities, best in class fuel economy with bosh HPCR fuel system with A1 class electronic governing, duel fuel filter system, pre filter including water separator and water in fuel (WIF) sensor and main filter, Electrical lift pump for faster response, standrd intergral set mounted radiator system, designed and testedfor50°C temp, hospital grade silencer suitably optimised to meet stringent noise emission standards laid down by MOEF/CPCB, completeexhaust pipe with clading as per site requirement, comforming to ISO 3046/BS5514, to drive alternator capable of delivering 50KW (58.5 KVA) at outdoor atmoshpheric conditions at 1MTR 1STC Jabalpur (MP), 12V (as per manufactuerer\"s recommendations) eletric battery start, completewith dynamic balanced fly wheel, all standard fittings/fixtures as per Manufacturer\"stechnical instructions, with and including suitable panel with techometer, lub oil temp, pressure gauze and Freqequencymeter and also incld self starter system , dynamo, fuel electric control panel with electronic governor (ECPG) and engine protection systems ( shut down, high water tempature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other comsumables items etc cmplt
151(b) Alternator: Brushless AC alternator, 3 phase 415 Volts, 4 wire rated for output of 58.5 KVA 46.8 kW, minimumn power factor 0.8, 1500 RPM, IP25 protection class enclosure, insulation class \"H\", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match with the engine as specified above.
152(c) BASE PLATE: Made of structural steel as per Manufacturer\"s |recommended design/specifications complete.
153(d) Accoustic Enclosure : Sheet metal fabricated cope type, powder coated silent enclosure manufactured on CNC machines as per letest CPCB norms complete. (Note: Enclosure shall be designed for reducing the sound level as under with following conditions as laid down in GSR No. 371 (E) dt 15 Aug 2008: (i) 75 DB at a distance of 1.0M at 75% load under field condition. (ii) 70 DB at 3.0M from Gen set when DG set is working at full load along with testing conformance, labelling certificaton, etc)
154(e) AMF Control Panel : Factory made powder coated, cubicle outdoor type, floor mounted LT Panel board made out of MS angle iron legs not less than 40x40x5mm in section and 3.15 mm thick CRCA outer sheet, front openable with electrolytic grade copper bus bar of 1000 Amp capacity for four poles with all standard switchgear and contactor and protection including necessary internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of the followings: (i) MCCB 415 Volts, 200 Amp, rating 4 pole 25 KA rupturing capacity, adjustable type 70%-100% -2 Nos. (ii) Digital Ammeter 0-200 Amps, flush type ISI marked with in-built selector switch 3 way and current transformers 200/5 A-01 Set.(iii) Digital Voltmeter 0-500 volts flush type ISI marked with in-built selector switch 3 way-01 set. (iv) Phase indicating lamps LED type (R-Y-B) -1 set. (v) All standard relays, circuits and protection required for automatic operation of Gen set. (v) By pass arrangement of suitable capacity complete.
155(f) Foundation/Plinth/Base: PCC platform of size extended 0.50M all round of DG set (outer dimensions), 0.60M above GL and 0.30M below GL in PCC 1:2:4 type B2 using 40mm graded stone aggregate, foundation 150mm thick and 150mm extending on all sides of PCC platform in PCC 1:4:8 type D2 using 40mm graded stone aggregate including necessary excavation & earth work, formwork and plaster/ rendering in CM (1:4) on all sides of PCC platform upto 15cm below from GL and two coats of white wash on plastered surfaces including prepration of surfaces complete all as directed.
156(g) Diesel storage tank - capacity adequate for storage of diesel for 12 hours operation of Gen set in addition to one No of capacity 200 Ltr Steel/GI Tank of make as approved by GE
157(h) Miscellaneous: Tool kit, operation and maintenance catalogue, spare parts list, overhauling manuals, guarantee card including genuiness certificate from Manufacturer etc shall be provided asper Manufacturer\"s standard practices as and when asked.
158General Notes for item No. 145.00: (i) The DG set shall be taken over only after it has been tested as per relevant IS specification/instructions by the contractor in the presence of an officer nominated by the Accepting Officer and signed copy of testing sheet should be provided by contractor as per MES procedure only after which completion will be given. (ii) All the expenses incurred on the above test including provision of testing apparatus,fuel required to carry out the above mentioned test shall be borne by the contractor without any extra cost to the Government. If the result of the test is not found satisfactory, the contractor shall at his own expenses, replace the defective equipments/ materials/ accessories or any part thereof as directed by the GE. Decision of Accepting Officer shall be final, conclusive and binding in this respect.
159Supply, installation, testing and commissioning complete of OEM manufactured, static silent (Sound proof enclosure) Diesel Engine Driven Generating set capable of delivering 80 KW (100 KVA output), at prime mover rating at 0.85 load factor as per ISO-8528 (Part-I), 415 Volts (AC three phase, 4 Wire system of supply) 50 Hz at 0.80 minimum power factor. The DG set shall consist of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with AMF control panel standardized by Manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe including all mounting accessories as required/ suitable for installation atJAK RRCunder GE(W) Jabalpur (MP) complete including, anti vibration pads, including all features to comply with latest CPCBIV + emission compliant norms/guidelines and comprising of the followings: Note:-Capacity of engine, alternators shall be worked out after taking all derating factors into consideration.
160(a) ENGINE (prime mover): Diesel engine 1500 RPM, direct injection, Min 3 cylinders, in line with electronic governer, engine, well designed air handing system with dry type, replaceable paper element air cleaner with restriction inductor, air to air after cooling, optimised turbocharger for increased altitude capabilities, best in class fuel economy with bosh HPCR fuel system with A1 class electronic governing, duel fuel filter system, pre filter including water separator and water in fuel (WIF) sensor and main filter, Electrical lift pump for faster response, standrd intergral set mounted radiator system, designed and testedfor50°C temp, hospital grade silencer suitable optimised to meet stringent noise emission latest standards laid down by MOEF/CPCB, complt exhaut pipe with clading as per site requirement, comfirming to ISO 3046/BS5514, to drive alternator capable of delivering 80 KW (100 KVA) at outdoor atmoshpheric conditions atJAK RRCunder GE(W) Jabalpur (MP), 12V(as per manufacturer recommendations) electric battery start, complt with dynamic balanced fly wheel, all standard fittings/fixtures as per manufacturer with and including suitable panel with techometer, lub oil temp, pressure guage and Freq meter and also incld self starter system , dynamo, fuel electric control panel with electronic governor (ECPG) and engine protection systems ( shut down, high water tempature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other comsumables items etc complete all as specified and directed.
161(b) Alternator: Brushless AC alternator, 3 phase 415 Volts, 4 wire rated for output of 100 KVA /80 kW, minimumn power factor 0.80, 1500 RPM, IP25 protection class enclosure, insulation class \"H\", salient pole, revolving field, single bearing automatic votage reulator coupled through flexible coupling with and to match with the engine as specified above.
162(c) BASE PLATE: Made of structural steel as per Manufacturer\"s make model. recommended design/specifications complete.
163(d) Acoustic Enclosure : Sheet metal fabricated cope type, powder coated silent enclosure manufactured on CNC machines as per latest CPCB IV norms complete.Note: Enclosure shall be designed for reducing the sound level as under with following conditions as laid down in GSR No. 371 (E) dt 15 Aug 2008:(i) 75 DB at a distance of 1.0M at 75% load under field condition. (ii) 70 DB at 3.0M from Gen set when DG set is working at full load along with testing conformance, labelling certificaton, etc
164(e) AMF Control Panel : Factory made powder coated, cubicle outdoor type, floor mounted LT Panel board made out of MS angle iron legs not less than 25x25x5mm in section and 3.15 mm thick CRCA outer sheet, front openable with electrolytic grade copper bus bar of 1000 Amp capacity for four poles with all standard switchgear and contactor and protection including necessary internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of the followings: (i) MCCB 415 Volts, 200 Amp, rating 4 pole 25 KA rupturing capacity, adjustable type 70%-100% -2 Nos. (ii) Digital Ammeter 0-200 Amps, flush type ISI marked with in-built selector switch 3 way and current transformers 200/5 A-01 Set. (iii) Digital Voltmeter 0-500 volts flush type ISI marked with in-built selector switch 3 way-01 set. (iv) Phase indicating lamps LED type (R-Y-B) -1 set.(v) All standard relays, circuits and protection required for automatic operation of Gen set. (vi) By pass arrangement of suitable capacity complete.
165(f) Foundation/Plinth/Base: PCC platform of size extended 0.50M all round of DG set (outer dimensions), 0.60M above GL and 0.30M below GL in PCC 1:2:4 type B2 using 40mm graded stone aggregate, foundation 150mm thick and 150mm extending on all sides of RCC platform in PCC 1:4:8 type D2 using 40mm graded stone aggregate including necessary excavation & earth work, formwork and plaster/ rendering in CM (1:4) on all sides of PCC platform upto 15cm below from GL and two coats of white wash on plastered surfaces including prepration of surfaces complete all as directed.
166(g) Diesel storage tank - capacity adequate for storage of diesel for 12 hours operation of Gen set in addition to one No of capacity 200 Ltr steel/GI tank of make as approved by GE
167(h) Miscellaneous: (i)Tool kit, operation and maintenance catalogue, spare parts list, overhauling manuals, guarantee card including genuiness certificate from manufacturer etc shall be provided asper Manufacturer\"s standard practices as and when asked.
168General Notes for item No. 146.00: (i) The DG set shall be taken over only after it has been tested as per relevant IS specification/instructions by the contractor in the presence of an officer nominated by the Accepting Officer and signed copy of testing sheet should be provided by contractor as per MES procedure only after which completion will be given. (ii) All the expenses incurred on the above test including provision of testing apparatus,fuel required to carry out the above mentioned test shall be borne by the contractor without any extra cost to the Government. If the result of the test is not found satisfactory, the contractor shall at his own expense, replace the defective equipments/ materials/ accessories or any, thereof as directed by the GE. Decision of Accepting Officer shall be final, conclusive and binding in this respect.
169Supply, installation, testing and commissioning complete of OEM manufactured, static silent (Sound proof enclosure) Diesel Engine Driven Generating set capable of delivering 100 KW (125 KVA output), at prime mover rating at 0.85 load factor as per ISO-8528 (Part-I), 415 Volts (AC three phase, 4 Wire system of supply) 50 Hz at 0.80 minimum power factor. The DG set shall consist of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with AMF control panel standardized by Manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe including all mounting accessories as required/ suitable for installation at HQ 1STC Under GE(W) Jabalpur (MP) complete including, anti vibration pads, including all features to comply with latest CPCBIV + emission compliant norms/guidelines and comprising of the followings: Note:-Capacity of engine, alternators shall be worked out after taking all derating factors into consideration.
170(a) ENGINE (prime mover): Diesel engine 1500 RPM, direct injection, Min 3 cylinders, in line with electronic governer, engine, well designed air handing system with dry type, replaceable paper element air cleaner with restriction inductor, air to air after cooling, optimised turbocharger for increased altitude capabilities, best in class fuel economy with bosh HPCR fuel system with A1 class electronic governing, duel fuel filter system, pre filter including water separator and water in fuel (WIF) sensor and main filter, Electrical lift pump for faster response, standrd intergral set mounted radiator system, designed and testedfor50°C temp, hospital grade silencer suitable optimised to meet stringent noise emission latest standards laid down by MOEF/CPCB, complt exhaut pipe with clading as per site requirement, comfirming to ISO 3046/BS5514, to drive alternator capable of delivering 100 KW (125 KVA) at outdoor atmoshpheric conditions at HQ 1STC Under GE(W) Jabalpur (MP), 12V(as per manufacturer recommendations) electric battery start, complt with dynamic balanced fly wheel, all standard fittings/fixtures as per manufacturer with and including suitable panel with techometer, lub oil temp, pressure guage and Freq meter and also incld self starter system , dynamo, fuel electric control panel with electronic governor (ECPG) and engine protection systems ( shut down, high water tempature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other comsumables items etc complete all as specified and directed.
171(b) Alternator: Brushless AC alternator, 3 phase 415 Volts, 4 wire rated for output of 125 KVA /100 kW, minimumn power factor 0.80, 1500 RPM, IP25 protection class enclosure, insulation class \"H\", salient pole, revolving field, single bearing automatic votage reulator coupled through flexible coupling with and to match with the engine as specified above.
172(c) BASE PLATE: Made of structural steel as per Manufacturer\"s make model. recommended design/specifications complete.
173(d) Acoustic Enclosure : Sheet metal fabricated cope type, powder coated silent enclosure manufactured on CNC machines as per latest CPCB IV norms complete.Note: Enclosure shall be designed for reducing the sound level as under with following conditions as laid down in GSR No. 371 (E) dt 15 Aug 2008:(i) 75 DB at a distance of 1.0M at 75% load under field condition. (ii) 70 DB at 3.0M from Gen set when DG set is working at full load along with testing conformance, labelling certificaton, etc
174(e) AMF Control Panel : Factory made powder coated, cubicle outdoor type, floor mounted LT Panel board made out of MS angle iron legs not less than 25x25x5mm in section and 3.15 mm thick CRCA outer sheet, front openable with electrolytic grade copper bus bar of 1000 Amp capacity for four poles with all standard switchgear and contactor and protection including necessary internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of the followings: (i) MCCB 415 Volts, 200 Amp, rating 4 pole 25 KA rupturing capacity, adjustable type 70%-100% -2 Nos. (ii) Digital Ammeter 0-200 Amps, flush type ISI marked with in-built selector switch 3 way and current transformers 200/5 A-01 Set. (iii) Digital Voltmeter 0-500 volts flush type ISI marked with in-built selector switch 3 way-01 set. (iv) Phase indicating lamps LED type (R-Y-B) -1 set.(v) All standard relays, circuits and protection required for automatic operation of Gen set. (vi) By pass arrangement of suitable capacity complete.
175(f) Foundation/Plinth/Base: PCC platform of size extended 0.50M all round of DG set (outer dimensions), 0.60M above GL and 0.30M below GL in PCC 1:2:4 type B2 using 40mm graded stone aggregate, foundation 150mm thick and 150mm extending on all sides of PCC platform in RCC 1:4:8 type D2 using 40mm graded stone aggregate including necessary excavation & earth work, formwork and plaster/ rendering in CM (1:4) on all sides of PCC platform upto 15cm below from GL and two coats of white wash on plastered surfaces including prepration of surfaces complete all as directed.
176(g) Diesel storage tank - capacity adequate for storage of diesel for 12 hours operation of Gen set in addition to one No of capacity 200 Ltr steel/GI tank of make as approved by GE
177(h) Miscellaneous: (i)Tool kit, operation and maintenance catalogue, spare parts list, overhauling manuals, guarantee card including genuiness certificate from manufacturer etc shall be provided asper Manufacturer\"s standard practices as and when asked.
178General Notes for item No. 147.00: (i) The DG set shall be taken over only after it has been tested as per relevant IS specification/instructionsin the presence of an officer nominated by the Accepting Officer and signed copy of testing sheet should be provided by contractor as per MES procedure only after which completion will be given. (ii) All the expenses incurred on the above test including provision of testing apparatus,fuel required to carry out the above mentioned test shall be borne by the contractor without any extra cost to the Government. If the result of the test is not found satisfactory, the contractor shall at his own expense, replace the defective equipments/ materials/ accessories or any, thereof as directed by the GE. Decision of Accepting Officer shall be final, conclusive and binding in this respect.
179M&L for earthingwith galvanized steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe medium grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed.Note:- GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor
180Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m all as specified and directed.
181S & F of DWC Pipe IS-16205, size inner dia 103 mm, outer dia 120 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at sitecomplete all as specified and as directed .
182S & F complete with totally enclosed self supporting structure / cubicle, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with sinle hinged door at front with suitable locking arrangement, structure treated under 7 - tank metal treatment process and duly powder coated all as specified and directed with following switch gear:-(a) MCCB four pole 160 Amps, adjustable type, 415 volts, 25 KA, 50 Hz AC supply - 02 Nos.(b) On load change over switch of capacity 200 Amps, 415 volts, 4 pole - 01 No.
183M & L for LT Cable route indicator with a welded/riveted disc of 4 inch dia and engraved with cable with cable route marker made out of angle iron 40 x 40 x4 mm thick dug in ground with in and incl PCC 1:3:6 type C1 using 20mm graded aggregate at approx distance 100 mtr including necessary earth work complete all as specified and directed.
184Cutting the tar macadam road / hard standings for laying cable and excavating not exe. 1.5 wide and 1.5m indepth and getting out all as directed including filing back and finishing it with PCC complete matching with the surroundings complete all as specified and directed.
185Supply and fix Galvanised iron strip 32x 6mm with and including saddles and fixing screws etc and jointing of strips with suitable size of nuts, bolts & washers; for roof conductors and down conductors above ground complete all as specified and directed.
186Supply, laying or fixing or passing through pipe, commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 corecomplete all asspecified & directed.(Note : Excavation and earthwork, sand cushioning and cable protection shall be measured and paid for separately.)
187Supply, laying or fixing or passing through pipe, commissioning and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core complete all as specified & directed. (Note : Excavation and earthwork, sand cushioning and cable protection shall be measured and paid for separately.)
188Excavationin trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any typeof soil complete all as specified and directed.
189Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
190Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
191Supply and laying sand cushioning with dry and clean washed sand over Jand under the under ground cable in trenches, ducts for cable protection 150 mm below & 80 mm above the cable as protection of cable complete as specified & directed. Note : Punned thickness of sand shall be measured & paid.
192S&F On load Manaul change over switch 415V in sheet metal enclosure 4 pole of capacity 200 Amps complete all as specified and as directed..
193S&F change over switch 4 pole 250 Amp, 415 Volts, On load type and front handle type with enclosure including connection and fixing accessories complete all as specified and directed.
194Material & labour for Best quality locally available, sub class B fly ash bricksfor cable protection cover, laid flat and dry in trenches over the cable perpendicular to the direction of the cable with width equal to the length of brick complete all as specified and as directed.
195Supplying and fixing/ laying of 50 mm bore dia GI pipe medium grade in trenches/ under roads/ along pole/ wall including all necessary fittings & clamps made out of 25x3mm flat iron as required for cable protection etccomplete all as specified and directed.
196M&L PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in coloumns, pillars and posts complete all specified and directed.
197S&F roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee angle, channel or flatsections) including distance pieces cleats etc conforming to Fe 410W (Gde 250) quality \"A\" completeall specified and directed.
198M&L for mild steel work conforming to Fe-290 Gde -165 as in nosing to steps including embedingin concrete and screwing etc, wind ties for roof including securing bolts, posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified and directed.
199M & L forprovidingcement concrete (1:2:4)type B1(20 mm gradedcrushed stone aggregate) asin roof kerbs or mud stops, rounded or chamfered on edgescomplete all as specified and directed.
200M&L 40mm thickPCC 1:2:4 type B1 (20mm graded crushed stone aggregate) as in floors finished even & smooth using extra cement in patchescomplete all as specified and directed.
201Schedule of credit amount ofRs. 63,478.00to be deducted during AOC

AI Tender Summary

OUR REF NO 45385036
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 83 Lakhs
LAST DATE 21-10-2024
Authority
Authority Name Military Engineer Services
Work Description (a) SPL REPAIROF BLDG NO P-2/01 to 08 (OR MD ACCN) ATROBERT BARRACK ( GROVER ENCLAVE) OF MH JABALPUR (b) PROVISION OF 63 KVA GEN SET (SILENT TYPE) FOR 1 WTS, 10 MTR AIR RIFLE & PISTOL RANGE, IT & OFFICERS OF 1 MTR , 1STC JABALPUR(c) PROVN OF 01 X 100 KVA SILENT DIESEL GENR SET FOR RECORD OFFICE COMPLEX (BLDG NO P-254) OF JAK RRC(d) PROVN OF 01X125 KVA DG SET AND ALLIED SERVICES WITH CONNECTIVITY ALONGWITH SHED FOR POWER BACKUP OF TECH LABS & SIMULATOR LABS FOR AGNIVEER IN1 STC UNDER GE (WEST) JABALPUR.
Basic Detail
Tender No 81003/E8
Bidding Type Tender
Location
City jabalpur
State Madhya Pradesh
Key Dates
Publish Date 16 Oct 2024
Submission Date 21 Oct 2024
Open Date 23 Oct 2024
Finance
Tender Value 83 Lakhs
Tender Fee 1000
EMD 1.49 Lakhs
Exemption Available
Document List
72839d8b-014f-470f-b633-26fe14ad00c8.html
BOQ_756224.xls
TENDERGRC.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 16, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 21, 2024
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 21, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 23, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

72839d8b-014f-470f-b633-26fe14ad00c8.html

xls

BOQ_756224.xls

pdf

TENDERGRC.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender