Tender For Soil Investigation And Structural Design In R/O Provisioning Of Additional Room With Attached Toilet At M-7 Transmitter Room At Dinjan, Dinjan-Assam
TDR : 45342931
Tender Notice
BOQ
Expired
Dinjan
Assam
Tender For Soil Investigation And Structural Design In R/O Provisioning Of Additional Room With Attached Toilet At M-7 Transmitter Room At Dinjan
Name of Work:Provisioning of additional room with attached toilet at M-7 Transmitter room at Dinjan
Sl. No.
Item Description
1
Carrying out soil investigation as given below :-Boring through sand/clay/soft strata with 150mm pipe from ground level to 10 mtr depth.(a)Subsurface investigation :-(i) Grain size analysis, specific gravity, unit weight and natural moinsture content of soil.(ii)Liquid limit, plastic limit & swelling index.(iii) Consolidated tests for consolidation properties.(iv) Shear strength tests for shear strength parameters.(v)Chemical tests for soluble chloride and sulphate based in local information and experiences.(vi) Shear characteristic from un distrubed sample using direct shear/tri axial shear test.(vii) Field tests as per Appx \"C\" of IS 1892.(viii) Plate load tests at recommended depth of foundation.(ix) CBR values (Soaked & unsoaked) & K value for strata.(x)Depth of water table if found in bore holes shall to be reported to GE.(b)The report to include clearly the following parameters :-(i) Layout of trial pits & bore holes on proposed site plan.(ii)Record of boring as per Appx \"D\" of IS 1892.(iii) Soil/Rock properties as per detailed exploration (Table 3 of IS 1892).(iv) Soil properties basd on field tests.(v)Estimation of safe bearing pressure based on safe bearing capacity as per shear criteria and settlement criteria for rectangular.It also include detailed calculation of SBC.Note : In case low bearing capacity recommendation may include bearing capacity calculation SBC & Settlement calculation for raft foundation. (vi) Recommendation for pile with pile capacity in case weaker strata in encountered.(vii)Other relevant recommendation for foundation and improvement of soil if necessary.(viii) Recommendation of existing soil for backfill purpose.Notes for item No 1 : (ii) all the reports/results will be got vetted from any of the IIT\"s or Govt Engineer College\"s after approval from GE/Engineer-in-Charge.
2
Preparation of structural design and architectural drawing for Provision of Additional Room with attached Toilet at M-7 Transmitter Room at AF Stn Dinjan under GE (AF) Mohanbari (Room size 5.64m x 5.64m, Toilet size 1.80M x 1.50M) clear height 3.20M (Plinth area 31.80 Sqm) as per line plan attached.Note :(a)Architectural Drawing, Structural Design and drawing included Design claculation folder shall be vetted by IIT/Govt Engg college in original.(b)Bidder shall have to submit 5 (Five) copies of drawing in A3 size and soft copy in CD.(c)Completion duration 30 (thirty) from the day issue of Job Order.
3
Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.