Educational and Research Institute Statutory Bodies & Commissions/Committees Closing in 0 days TDR #45322716

Tender For Infrastructural Development Of Lighthouse School Complex (Lsc) - Government Higher Secondary School (Ghss) Medziphema Under Chumoukedima District

Issued by Statutory Bodies & Commissions/Committees · medziphema, Nagaland
Tender Value
14.96 Crore
Estimated cost
Bid Submission
25 Oct 2024
0 days left
EMD
14.96 Lakhs
Bank guarantee accepted
Document Fee
15000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
medziphema → Nagaland
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Infrastructural Development Of Lighthouse School Complex (Lsc) - Government Higher Secondary School (Ghss) Medziphema Under Chumoukedima District

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Oct-2024 Corrigendum for LSC GHSS Medziphema under Chumoukedima District Date 25-Oct-2024

BOQ

Name of Work: Infrastructural Development of Lighthouse School Complex (LSC)- Government Higher Secondary School (GHSS) Medziphema
Sl. No. Item Description
1ACADEMIC GROUND FLOOR CIVIL
2Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
3All kind of Soil
4Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
5Ordinary Rock
6Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)
7Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor.
8With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
10Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with common burnt clay non-modular bricks:
111:4 (1 cement: 4 coarse sand)
12Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
131:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
14Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:
15Cement mortar 1:6 (1 cement:6 coarse sand)
16Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
17All works upto Plinth level
18All works above Plinth level upto floor V level
19Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 Cement 2 coarse sand 4 graded stone aggregate 12.5mm nominal size).
20Centering and shuttering including strutting, propping etc. and removal of form work for:
21Foundations, footings, bases of Columns
22Centering and shuttering including strutting, propping etc. and removal of form for
23Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers
24Centering and shuttering including strutting, propping etc. and removal of form for
25Columns, Pillars, Piers, Abutments, Posts & Struts
26Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete above plinth level
27Hot Rolled deformed bars
28Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
29With F.P.S (Non-Modular) bricks
30Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
31Cement mortar 1:4 (1 cement : 4 coarse sand)
32Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
33Second class teak wood
34Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-in charge and panelling with panels of: (Note: screws shall be paid separately) Butt hinges and necessary
3512 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
36Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-Charge. (Note: Butt hinges and necessary screws shall be paid separately)
37Second class Teak wood
3835mm thick shutters
39Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge.
40Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
4135 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
42Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
43100x75x4 mm
44Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
45250x16 mm
46Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
47200 * 10mm
48Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
49125 mm
50Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
51Twin rubber stopper
52Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
53Fixed to Opening / wooden frames with rawl plugs screws etc
54Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse)
5525 mm thick
56Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades.
578mm thick (mirror polished and machine cut edge)
58Granite stone of any colour and shade
59Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with:
60Udaipur green marble
61Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).
62Dark shade pigment using ordinary cement
63Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
64Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
65Size of Tile 600x600 mm
66Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
67Size of Tile 600x600 mm
68Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses.
690.50 mm thick
70Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
71Hot finished welded type tubes
7212 mm cement plaster of mix:
731:6 (1 cement :6 Coarse sand)
7420 mm cement plaster of mix:
751:6 (1 cement :6 Coarse sand)
766 mm cement plaster of mix:
77(1 cement: 3 fine sand)
78Applying priming coat
79With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood)
80Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant.
81Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
82With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
83Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
84Painting with synthetic enamel paint of approval brand and manufacture to give an even shade es
85Two or more coats on new work
86Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:
87New work ( Two or more coats) over and including priming coat with water thinnable cement primer
88Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content less than 50 gm/litre, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.
89Two Coats
90Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
91Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately)
92For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for separately)
93Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
94Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item)
95With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
96Providing 10mm thick plaster of Paris (gypsum anhydrous) ceiling upto a height of 5m above floor level, over first class kail wood strips 25x6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately):
97Flat surfaces
98Providing expansion joints with 25mm thick bituminous pad as per detailed drawings etc. complete
99ACADEMIC FIRST FLOOR CIVIL
100Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
101All works above Plinth level upto floor V level
102Centering and shuttering including strutting, propping etc. and removal of form for
103Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers
104Centering and shuttering including strutting, propping etc. and removal of form for
105Columns, Pillars, Piers, Abutments, Posts & Struts
106Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
107Hot Rolled deformed bars
108Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
109With F.P.S (Non-Modular) bricks
110Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
111Cement mortar 1:4 (1 cement : 4 coarse sand)
112Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
113Second class teak wood
114Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary
11512 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
116Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-Charge. (Note: Butt hinges and necessary screws shall be paid seperately)
117Second class Teak wood
11835mm thick shutters
119Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge
120Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
12135 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
122Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
123100x75x4 mm
124Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
125250x16 mm
126Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
127200 * 10mm
128Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
129125 mm
130Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
131Twin rubber stopper
132Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
133Fixed to Opening / wooden frames with rawl plugs screws etc
134Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse)
13525 mm thick
136Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with:
137Udaipur green marble
138Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
139Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
140Size of Tile 600x600 mm
141Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
142Size of Tile 600x600 mm
143Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses.
1440.50 mm thick
145Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
146Hot finished welded type tubes
14712 mm cement plaster of mix:
1481:6 (1 cement :6 Coarse sand)
14920 mm cement plaster of mix:
1501:6 (1 cement :6 Coarse sand)
1516 mm cement plaster of mix:
152(1 cement: 3 fine sand)
153Applying priming coat
154With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood)
155Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant.
156Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
157With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
158Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
159Painting with synthetic enamel paint of approval brand and manufacture to give an even shade es
160Two or more coats on new work
161Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:
162New work ( Two or more coats) over and including priming coat with water thinnable cement primer
163Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content less than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.
164Two Coats
165Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
166Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately)For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
167For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
168Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
169Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item)
170With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
171Providing 10mm thick plaster of paris (gypsum anhydrous) ceiling upto a height of 5m above floor level, over first class kail wood strips 25x6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be pald separately):
172Flat surfaces
173Providing expansion joints with 25mm thick bituminous pad as per detailed drawings etc. complete
174COMPOUND WALL PART A
175Earth work in excavation by mechanical means (Hydraulic excavator/Manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m. All Kinds of soil
176All kind of Soil
177Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
1781:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
179Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
180All works upto Plinth level
181All works above Plinth level upto floor V level
182Centering and shuttering including strutting, propping etc. and removal of form work for:
183Foundations, footings, bases of Columns
184Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
185Hot Rolled deformed bars
186Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
187With FPS( Non-Modular) bricks
188Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
189Second class teak wood
190Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary
19112 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
192Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately)
193For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
194Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
195Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item)
196With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
19715 mm cement plaster on the rough side of single or half brick wall of mix:
1981:4 (1 cement :4 fine sand)
199Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
200With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
201Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content less than 50 gm/litre, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.Two Coats
202Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
203Hot finished welded type tubes
204COMPOUND WALL PART B
205Earth work in excavation by mechanical means (Hydraulic excavator/Manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m.
206All Kinds of soil
207Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable seperately)
208All works upto Plinth level
209Providing and fixing G.I Chain Link Fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-Charge
210Made of G.I wire of dia 4mm
211Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
212Providing and Fixing Barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete.
213WATER BOUND MACADAM (W.B.M) ROAD
214Excavation in Soil using Hydraulic Excavator and Tippers with Disposal upto 1000 metres. Unit Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and across sections, and transporting to the embankment location within all lifts and lead upto 1000m
215Compacting Original Ground Arounds Loosening of the ground upto a level of 500 mm below the sub grade level, watered, graded and compacted in layers to meet the requirement of table 300-2 for sub-grade construction
216Compacting Original Ground supporting sub-grade
217Compacting Original Ground supporting Embankment
218Construction of granular sub-base by providing granular material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory power roller to achieve the desired density, complete as per clause 401
219By Mix in Place Method
220Granular Sub-Base Grading-I Material
221Granular Sub-Base Grading-II Material
222Granular Sub-Base Grading-III Material
223Water Bound Macadam
224Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/binding materials to fill up the interstices of coarse aggregate, watering and compacting to required density
225By Manual Means
226Grading II
227Using Screening Crushable type such as Moorum or Gravel
228Grading III
229Using Screening Crushable type such as Moorum or Gravel
230Prime Coat
231Prime Coat over WMM / WBM
232Providing and applying primer coat with SS1 grade bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sum using mechanical means.
233Tack Coat
234Tack Coat on Bituminous surfaces
235Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sum on the prepared bituminous surface cleaned with mechanical broom.
236Bituminous Macadam Grading -I
237Providing and laying bituminous macadam with higher capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction
238Providing and laying bituminous macadam with higher capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction
239Surface Dressing
240Providing and laying surface dressing as wearing course in single coat using crushed stone aggregates of specified size on a layer of bituminous binder laid on prepared surface and rolling with 8- 10 tonne smooth wheeled steel roller
24113 mm nominal chipping size
242Seal Coat Description Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats
243Type A
244Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:
245600mm dia R.C.C. Pipe
246Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
2471:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
248Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
249With FPS( Non-Modular) bricks
25012 mm cement plaster finished with floating coat of neat cement of mix
2511:4 (1 cement :4 Fine sand)
252UNDER GROUND TANK-1
253Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
254All kind of Soil
255Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials.
256All Kinds of soil
257Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials.
258Ordinary or Hard Rock
259Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with common burnt clay non-modular bricks:
2601:4 (1 cement: 4 coarse sand)
261Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
2621:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
263Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
264All works upto Plinth level
265Centering and shuttering including strutting, propping etc. and removal of form work for:
266Foundations, footings, bases of Columns
267Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
268Hot Rolled deformed bars
269Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
270Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) as per standard design.
271With 20 mm diameter round bar
272Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality.
273LD-2.5
274Rectangular shape 600x450mm internal dimensions
275LANDSCAPING WORK
276Planting of Trees and their Maintenance for one Year
277Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year
278Tree Guard with MS Angle Iron and Steel Wire
279Providing and fixing tree guard 0.60 metre square, 2.00 metre high fabricated with MS angle iron 30 x 30 x 3 mm, MS iron 25 x 3; mm and steel wire3 mm dia welded and fabricated as per design in two halves bolted together
280SEPTIC TANK 1
281Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
282All kind of Soil
283Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
284Ordinary Rock
285Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
2861:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
287Reinforced cement concrete work in walls (any thickness), Including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.
2881:1.5:3 (1 Cement: 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size)
289Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
290Hot Rolled deformed bars
291Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
292With F. P. S. (non-modular) bricks
29312 mm cement plaster finished with floating coat of neat cement of mix
2941:4 (1 cement :4 Fine sand)
295Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
296Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
297Inside dimensions 600x850 mm and 45 cm deep for single pipe line.
298With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5
299SEPTIC TANK 2
300Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
301All kind of Soil
302Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
303Ordinary Rock
304Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
3051:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
306Reinforced cement concrete work in walls (any thickness), Including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.
3071:1.5:3 (1 Cement: 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size)
308Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
309Hot Rolled deformed bars
310Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
311With F. P. S. (non-modular) bricks
31212 mm cement plaster finished with floating coat of neat cement of mix
3131:4 (1 cement :4 Fine sand)
314Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
315Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
316Inside dimensions 600x850 mm and 45 cm deep for single pipe line.
317With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5
318SEPTIC TANK 3
319Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
320All kind of Soil
321Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
322Ordinary Rock
323Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
3241:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
325Reinforced cement concrete work in walls (any thickness), Including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.
3261:1.5:3 (1 Cement: 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size)
327Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
328Hot Rolled deformed bars
329Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
330With F. P. S. (non-modular) bricks
33112 mm cement plaster finished with floating coat of neat cement of mix
3321:4 (1 cement :4 Fine sand)
333Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
334Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
335Inside dimensions 600x850 mm and 45 cm deep for single pipe line.
336With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5
337RAIN WATER HARVESTING
338Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
339All kind of Soil
340Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
3411:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
34212 mm cement plaster finished with a floating coat of neat cement of mix:
3431:3 (1 cement :4 fine sand)
344Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
345With FPS( Non-Modular) bricks
346Providing and fixing P.V.C. Rain water pipes of 160 mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, including fixing the pipe on wall using approved wooden cleats projecting 25 mm to 40 mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C.fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
347Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 mm to 40 mm from face of wall a fixing with clips of approved quality and One Number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 years or any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
348DEMOLITION AND RETROFITTING WORK OF EXISTING BLOCK
349Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge.
350Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge.
351In cement mortar
352Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:
353Of area 3 sq. metres and below
354Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, racking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish of the dumping ground, all complete as per the direction of Engineer-in-charge
355With cement mortar 1:4 (1 cement: 4 fine sand)
356Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
357For thickness of tiles 10 mm to 25 mm
358Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
359With FPS( Non-Modular) bricks
360Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
361Size of Tile 600x600 mm
362Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
363Size of Tile 600x600 mm
364Painting with synthetic enamel paint of approval brand and manufacture to give an even shade es
365Two or more coats on new work
366Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:
367New work ( Two or more coats) over and including priming coat with water thinnable cement primer
368Providing and laying in-situ / ready mix M25 grade RCC jacketing work around the existing COLUMN, BEAM, SLAB etc.complete. (with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer with fine aggregates of required specifications ( VSI sand finely washed etc ), height of 8 to 10 meter)
369Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
370Hot Rolled deformed bars
371PLUMBING GROUND FLOOR
372Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931
37315 mm nominal bore
374Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:
375White Vitreous China Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
376Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
377W.C. pan with ISI marked black solid plastic seat and lid
378Providing and fixing white vitreous China flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.1. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:
379Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
380Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
381White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
382Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.
383Rectangular shape 453x357mm dia.
384Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge
385Concealed work, including cutting chases and making good the walls etc.
38620 mm nominal outer dia Pipes
387Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge
388External work
38940 mm nominal outer dia Pipes
39050 mm nominal outer dia Pipes
391Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
392Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
393Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.
394With common burnt clay F.P.S ( non-modular )bricks of class designation 7.5
395Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore
396Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with watertight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
397100x100 mm size P type
398With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5
399PLUMBING FIRST FLOOR
400Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931
40115 mm nominal bore
402Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:
403White Vitreous China Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
404Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
405W.C. pan with ISI marked black solid plastic seat and lid
406Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
407White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
408Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.
409Rectangular shape 453x357mm dia.
410Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge
411Concealed work, including cutting chases and making good the walls etc.
41220 mm nominal outer dia Pipes
413Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge
414External work
41540 mm nominal outer dia Pipes
41650 mm nominal outer dia Pipes
417Providing and fixing 75mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
418Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
419Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
42015 mm nominal bore
421Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
422FIRE FIGHTING GROUND FLOOR
423Supplying,installing,testingandcommissioningopticaltype smoke detector complete on box as per specification no.FFFAS/ SD
424Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm Dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
425ground floor to first
426SupplyingandinstallingwallmountingswingingHosereel drumfittedwith19mmdia.30meterhighpressure polypropylene(Polyhouse)longfittedwithnecessaryaccessoriescomplete as per specification no. FF-FFA/HV
427CO2 EXTINGUISHER
428ABC EXTINGUISHER
429Hooter
430Manual Call Point
431Fire Alarm Control Panel
432Fire Pump
433Butterfly valve
434FIRE FIGHTING FIRST FLOOR
435Supplying,installing,testingandcommissioningopticaltype smoke detector complete on box as per specification no.FFFAS/ SD
436Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
437SupplyingandinstallingwallmountingswingingHosereel drumfittedwith19mmdia.30meterhighpressure polypropylene(Polyhouse)longfittedwithnecessaryaccessoriescomplete as per specification no. FF-FFA/HV
438CO2 EXTINGUISHER
439ABC EXTINGUISHER
440Hooter
441Manual Call Point
442Fire Alarm Control Panel
443Butterfly valve
444GROUND FLOOR- INTERNAL ELECTRIFICATION
445Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e. providing and fixing anchor made 5A flush type switches and all other accessories
446a. Light point Short
447b. Light point Medium
448c. Light point Long
449d. Call bell Point Long
450e. Fan point medium
451f. Exhaust fan point medium
452Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc.
453a. Medium point
454b. Long point
455Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc.
456a. Medium point
457b. Long point
458Wiring for circuit/sub-main with pvc insulated copper cable core in surface casing capping etc.
459a. With 1.5 mm2 copper cable s/core
460b. With 2.5 mm2 copper cable s/core
461c. With 4 mm2 copper cable s/core
462d. With 6mm2 copper cable s/core
463e. With 10mm2 copper cable s/core
464f. With 1mm copper cable s/core for earth continuity
465Fixing & Providing, Drilling holes and connection etc
466a. MCB 10A
467b. MCB 16A
468c. MCB 20A
469d. Isolator 40 Amp 2 pole
470e. Isolator 63 Amp 2 pole
471f. MCB Box 10 ways
472g. MCB Box 12 ways
473h. Main Switch 100A
474i. Bus-Bar 100A 4 strips
475j. TPN 100A
476k. Change over Switch 100A
477l. Angle holder
478m. Bracket holder
479n. LED Double tube light fitting 40w with all accessories
480o. Exhaust fan with all accessories
481p. LED bulb 9w
482q. Call Bell Ding Dong
483r. Bulk head fitting with all accessories
484s. Ceiling Fan with all accesorries
485Providing & fixing, drilling holes and connection etc.
486a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal, salt etc.as required. The depth of the pit shall be atleast 3m or as per moisture availability.
487b. Copper wire 4sq.mm
488c. Lightning arrester
489d. Panel Board
490e.100 Sq.mm Al. LT. Power Cable
491Supplying and installing Energy Meter
492Armed cablefor Main 4 core X 10 Sqmm for Building
493Armed cablefor Main 4 core X 4 Sqmm for Building
494Armed cablefor Main 4 core X 35 Sqmm for Building
495Supplying and installing Water Purifier
496Supplying and installing 5 KVA UPS
497FIRST FLOOR- INTERNAL ELECTRIFICATION
498Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e providing and fixing anchor made 5A flush type switches and all other accessories
499a. Light point Short
500b. Light point Medium
501c. Light point Long
502d. Call bell Point Long
503e. Fan point medium
504f. Exhaust fan point medium
505Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc.
506a. Medium point
507b. Long point
508Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc.
509a. Medium point
510b. Long point
511Wiring for circuit/sub-main with pvc insulated copper cable core in surface casing capping etc.
512a. With 1.5 mm2 copper cable s/core
513b. With 2.5 mm2 copper cable s/core
514c. with 4 mm2 copper cable s/core
515d. With 6mm2 copper cable s/core
516e. With 10mm2 copper cable s/core
517f. With 1mm copper cable s/core for earth continuity
518Fixing & Providing, Drilling holes and connection etc
519a. MCB 10A
520b. MCB 16A
521c. MCB 20A
522d. Isolator 40 Amp 2 pole
523e. Isolator 63 Amp 2 pole
524f. MCB Box 10 ways
525g. MCB Box 12 ways
526h. Angle holder
527i. Bracket holder
528j. LED Double tube light fitting 40w with all accessories
529k. Exhaust fan with all accessories
530l. LED bulb 9w
531m. Call Bell Ding Dong
532n. Bulk head fitting with all accessories
533o.Ceiling Fan with all accesorries
534Providing & fixing, drilling holes and connection etc.
535a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal,salt etc.as required. The depth of the pit shall be atleast 3m or as per moisture availability.
536b. Copper wire 4sq.mm
537c. Lightning arrester
538d. Panel Board
539Supplying and installing Water Purifier
540EXTERNAL ELECTRIFICATION
541Fixing & Providing, Drilling holes and connection etc
542a. MCB 20A
543b. Isolator 63 Amp 2 pole
544c. Main Switch 100A
545d. Bus-Bar 100A 4 strips
546e. TPN 100A
547f. Change over Switch 100A
548g. 60 watt LED for street Light
549h. Pole
550i. Pole Arm
551a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal, salt etc.as required. The depth of the pit shall be at least 3m or as per moisture availability.
552b. Copper wire 4sq.mm
553c. Lightning arrester
554d. Panel Board
555e.100 Sq.mm Al. LT. Power Cable
556Supplying and installing Energy Meter
557Armed cablefor Main 4 core X 10 Sqmm for Street light
558Supplying and installing 30 KVA DG Set
559BOYS HOSTEL GROUND FLOOR CIVIL
560Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
561All kind of Soil
562Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
563Ordinary Rock
564Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)
565Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor. With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
566With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
567Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
568Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with common burnt clay non-modular bricks:
5691:4 (1 cement: 4 coarse sand)
570Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
5711:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
572Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
573All works upto Plinth level
574All works above Plinth level upto floor V level
575Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 Cement 2 coarse sand 4 graded stone aggregate 12.5mm nominal size).
576Centering and shuttering including strutting, propping etc. and removal of form work for:
577Foundations, footings, bases of Columns
578Centering and shuttering including strutting, propping etc. and removal of form for
579Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers
580Centering and shuttering including strutting, propping etc. and removal of form for
581Columns, Pillars, Piers, Abutments, Posts & Struts
582Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses.
5830.50 mm thick
584Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
585Hot finished welded type tubes
586Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
587Hot Rolled deformed bars
588Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
589With F. P. S. (non-modular) bricks
590Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
591Cement mortar 1:4 (1 cement : 4 coarse sand)
592Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
593Second class teak wood
594Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
59512 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
596Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-Charge. (Note: Butt hinges and necessary screws shall be paid seperately)
597Second class Teak wood
59830mm thick shutters
599Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge.
600Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
60135 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
602Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
603100x75x4 mm
604Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
605250x16 mm
606Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
607200 * 10mm
608Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
609125 mm
610Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
611Twin rubber stopper
612Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
613Fixed to opening/ wooden frames with rawl plugs screws etc.
614Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse 25 mm thick
61525 mm thick
616Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades.
6178mm thick (mirror polished and machine cut edge)
618Granite stone of any colour and shade
619Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with:
620Udaipur green marble
621Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
622Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
623Size of Tile 600x600 mm
624Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
625Size of Tile 600x600 mm
62612 mm cement plaster of mix:
6271:6 (1 cement :6 Coarse sand)
62820 mm cement plaster of mix:
6291:6 (1 cement :6 Coarse sand)
6306 mm cement plaster of mix:
631(1 cement: 3 fine sand)
632Applying priming coat
633With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood)
634Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant.
635Painting with synthetic enamel paint of approval brand and manufacture to give an even shade
636Two or more coats on new work
637Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
638Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
639With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
640Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.
641Two Coats
642Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
643Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately)
644For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
645Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
646Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item)
647With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
648Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
649BOYS HOSTEL FIRST FLOOR CIVIL
650Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
651All works above Plinth level upto floor V level
652Centering and shuttering including strutting, propping etc. and removal of form for
653Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers
654Centering and shuttering including strutting, propping etc. and removal of form for
655Columns, Pillars, Piers, Abutments, Posts & Struts
656Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
657Hot Rolled deformed bars
658Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
659With F. P. S. (non-modular) bricks
660Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
661Cement mortar 1:4 (1 cement : 4 coarse sand)
662Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
663Second class teak wood
664Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
66512 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
666Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge.
667Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
66835 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
669Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
670100x75x4 mm
671Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
672250x16 mm
673Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
674200 * 10mm
675Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
676125 mm
677Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
678Twin rubber stopper
679Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
680Fixed to opening/ wooden frames with rawl plugs screws etc.
681Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades.
6828mm thick (mirror polished and machine cut edge)
683Granite stone of any colour and shade
684Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with:
685Udaipur green marble
686Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
687Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
688Size of Tile 600x600 mm
689Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
690Size of Tile 600x600 mm
691Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses.
6920.50 mm thick
693Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
694Hot finished welded type tubes
69512 mm cement plaster of mix:
6961:6 (1 cement :6 Coarse sand)
69720 mm cement plaster of mix:
6981:6 (1 cement :6 Coarse sand)
699Applying priming coat
700With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood)
701Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant.
702Painting with synthetic enamel paint of approval brand and manufacture to give an even shade
703Two or more coats on new work
704Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
705Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
706With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
707Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.
708Two Coats
709Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately)
710For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
711Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
712Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item)
713With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
714Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
715BOYS HOSTEL SEPTIC TANK
716Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
717All kind of Soil
718Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
719Ordinary Rock
720Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
7211:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
722Reinforced cement concrete work in walls (any thickness), Including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.
7231:1.5:3 (1 Cement: 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size)
724Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
725Hot Rolled deformed bars
726Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
727With F. P. S. (non-modular) bricks
72812 mm cement plaster finished with floating coat of neat cement of mix
7291:4 (1 cement :4 Fine sand)
730Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
731Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
732Inside dimensions 600x850 mm and 45 cm deep for single pipe line.
733With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5
734BOYS HOSTEL GROUND FLOOR PLUMBING
735Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931
73615 mm nominal bore
737Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:
738White Vitreous China Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
739Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked black solid plastic seat and lid
740W.C. pan with ISI marked black solid plastic seat and lid
741Providing and fixing white vitreous China flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.1. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:
742Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
743Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
744White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
745Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.
746Rectangular shape 453x357mm dia.
747Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge
748Concealed work, including cutting chases and making good the walls etc.
74920 mm nominal outer dia Pipes
750Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge
751External work
75240 mm nominal outer dia Pipes
75350 mm nominal outer dia Pipes
754Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
755Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
756Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.
757With common burnt clay F.P.S( non-modular ) bricks of class designation 7.5
758Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore
759Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
760100x100 mm size P type
761With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5
762BOYS HOSTEL FIRST FLOOR PLUMBING
763Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931
76415 mm nominal bore
765Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:
766White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
767Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked black solid plastic seat and lid
768W.C. pan with ISI marked black solid plastic seat and lid
769Providing and fixing white vitreous China flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.1. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:
770Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
771Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.
772Rectangular shape 453x357mm dia.
773Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge
774Concealed work, including cutting chases and making good the walls etc.
77520 mm nominal outer dia Pipes
776Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge
777External work
77840 mm nominal outer dia Pipes
77950 mm nominal outer dia Pipes
780Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
781Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
782Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore
783Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
784BOYS HOSTEL GROUND FLOOR- INTERNAL ELECTRIFICATION
785Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e. providing and fixing anchor made 5A flush type switches and all other accessories
786a. Light point Short
787b. Light point Medium
788c. Light point Long
789d. Call bell Point Long
790e. Fan point medium
791f. Exhaust fan point medium
792Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc.
793a. Medium point
794b. Long point
795Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc.
796a. Medium point
797b. Long point
798Wiring for circuit/sub-main with PVC insulated copper cable core in surface casing capping etc.
799a. With 1.5 mm2 copper cable s/core
800b. With 2.5 mm2 copper cable s/core
801c. with 4 mm2 copper cable s/core
802d. With 6mm2 copper cable s/core
803e. With 10mm2 copper cable s/core
804f. With 1mm copper cable s/core for earth continuity
805Fixing & Providing, Drilling holes and connection etc
806a. MCB 10A
807b. MCB 16A
808c. MCB 20A
809d. Isolator 40 Amp 2 pole
810e. Isolator 63 Amp 2 pole
811f. MCB Box 10 ways
812g. MCB Box 12 ways
813h. Main Switch 100A
814i. Bus-Bar 100A 4 strips
815j. TPN 100A
816k. Change over Switch 100A
817l. Angle holder
818m. Bracket holder
819n. LED Double tube light fitting 2x40wx4 with all accessories
820o. Exhaust fan with all accessories
821p. LED bulb 9w
822q. Call Bell Ding Dong
823r. Bulk head fitting with all accessories
824Providing & fixing, drilling holes and connection etc.
825a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal, salt etc.as required. The depth of the pit shall be atleast 3m or as per moisture availability.
826b. Copper wire 4sq.mm
827c. Lightning arrester
828d. Panel Board
829e.100 Sq.mm Al. LT. Power Cable
830Supplying and installing Energy Meter
831Armed cablefor Main 4 core X 10 Sqmm for Building
832Armed cablefor Main 4 core X 4 Sqmm for Building
833Armed cablefor Main 4 core X 35 Sqmm for Building
834Supplying and installing Water Purifier
835BOYS HOSTEL FIRST FLOOR- INTERNAL ELECTRIFICATION
836Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e. providing and fixing anchor made 5A flush type switches and all other accessories
837a. Light point Short
838b. Light point Medium
839c. Light point Long
840d. Call bell Point Long
841e. Fan point medium
842f. Exhaust fan point medium
843Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc.
844a. Medium point
845b. Long point
846Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc.
847a. Medium point
848b. Long point
849Wiring for circuit/sub-main with PVC insulated copper cable core in surface casing capping etc.
850a. With 1.5 mm2 copper cable s/core
851b. With 2.5 mm2 copper cable s/core
852c. with 4 mm2 copper cable s/core
853d. With 6mm2 copper cable s/core
854e. With 10mm2 copper cable s/core
855f. With 1mm copper cable s/core for earth continuity
856Fixing & Providing, Drilling holes and connection etc
857a. MCB 10A
858b. MCB 16A
859c. MCB 20A
860d. Isolator 40 Amp 2 pole
861e. Isolator 63 Amp 2 pole
862f. MCB Box 10 ways
863g. MCB Box 12 ways
864h. Main Switch 100A
865i. Angle holder
866j. Bracket holder
867k. LED Double tube light fitting 2x40wx4 with all accessories
868l. Exhaust fan with all accessories
869m. LED bulb 9w
870n. Call Bell Ding Dong
871o. Bulk head fitting with all accessories
872Providing & fixing, drilling holes and connection etc.
873GIRLS HOSTEL GROUND FLOOR CIVIL
874Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
875All kind of Soil
876Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
877Ordinary Rock
878Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)
879Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor. With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
880With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
881Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
882Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with common burnt clay non-modular bricks:
8831:4 (1 cement: 4 coarse sand)
884Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
8851:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
886Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
887All works upto Plinth level
888All works above Plinth level upto floor V level
889Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 Cement 2 coarse sand 4 graded stone aggregate 12.5mm nominal size).
890Centering and shuttering including strutting, propping etc. and removal of form work for:
891Foundations, footings, bases of Columns
892Centering and shuttering including strutting, propping etc. and removal of form for
893Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers
894Centering and shuttering including strutting, propping etc. and removal of form for
895Columns, Pillars, Piers, Abutments, Posts & Struts
896Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses.
8970.50 mm thick
898Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
899Hot finished welded type tubes
900Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
901Hot Rolled deformed bars
902Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
903With F. P. S. (non-modular) bricks
904Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
905Cement mortar 1:4 (1 cement : 4 coarse sand)
906Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
907Second class teak wood
908Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
90912 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
910Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-Charge. (Note: Butt hinges and necessary screws shall be paid seperately)
911Second class Teak wood
91230mm thick shutters
913Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge.
914Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
91535 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
916Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
917100x75x4 mm
918Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
919250x16 mm
920Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
921200 * 10mm
922Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
923125 mm
924Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
925Twin rubber stopper
926Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
927Fixed to opening/ wooden frames with rawl plugs screws etc.
928Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse 25 mm thick
92925 mm thick
930Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades.
9318mm thick (mirror polished and machine cut edge)
932Granite stone of any colour and shade
933Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with:
934Udaipur green marble
935Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
936Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
937Size of Tile 600x600 mm
938Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
939Size of Tile 600x600 mm
94012 mm cement plaster of mix:
9411:6 (1 cement :6 Coarse sand)
94220 mm cement plaster of mix:
9431:6 (1 cement :6 Coarse sand)
9446 mm cement plaster of mix:
945(1 cement: 3 fine sand)
946Applying priming coat
947With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood)
948Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant.
949Painting with synthetic enamel paint of approval brand and manufacture to give an even shade
950Two or more coats on new work
951Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
952Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
953With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
954Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.
955Two Coats
956Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
957Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately)
958For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
959Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
960Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item)
961With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
962Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
963GIRLS HOSTEL FIRST FLOOR CIVIL
964Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
965All works above Plinth level upto floor V level
966Centering and shuttering including strutting, propping etc. and removal of form for
967Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers
968Centering and shuttering including strutting, propping etc. and removal of form for
969Columns, Pillars, Piers, Abutments, Posts & Struts
970Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
971Hot Rolled deformed bars
972Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
973With F. P. S. (non-modular) bricks
974Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
975Cement mortar 1:4 (1 cement : 4 coarse sand)
976Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
977Second class teak wood
978Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
97912 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
980Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge.
981Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
98235 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
983Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
984100x75x4 mm
985Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
986250x16 mm
987Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
988200 * 10mm
989Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
990125 mm
991Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
992Twin rubber stopper
993Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
994Fixed to opening/ wooden frames with rawl plugs screws etc.
995Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades.
9968mm thick (mirror polished and machine cut edge)
997Granite stone of any colour and shade
998Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with:
999Udaipur green marble
1000Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
1001Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
1002Size of Tile 600x600 mm
1003Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
1004Size of Tile 600x600 mm
1005Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses.
10060.50 mm thick
1007Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
1008Hot finished welded type tubes
100912 mm cement plaster of mix:
10101:6 (1 cement :6 Coarse sand)
101120 mm cement plaster of mix:
10121:6 (1 cement :6 Coarse sand)
1013Applying priming coat
1014With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood)
1015Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant.
1016Painting with synthetic enamel paint of approval brand and manufacture to give an even shade
1017Two or more coats on new work
1018Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1019Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
1020With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
1021Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.
1022Two Coats
1023Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately)
1024For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
1025Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
1026Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item)
1027With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
1028Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
1029GIRLS HOSTELSEPTIC TANK
1030Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
1031All kind of Soil
1032Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
1033Ordinary Rock
1034Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
10351:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
1036Reinforced cement concrete work in walls (any thickness), Including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.
10371:1.5:3 (1 Cement: 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size)
1038Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
1039Hot Rolled deformed bars
1040Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
1041With F. P. S. (non-modular) bricks
104212 mm cement plaster finished with floating coat of neat cement of mix
10431:4 (1 cement :4 Fine sand)
1044Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
1045Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
1046Inside dimensions 600x850 mm and 45 cm deep for single pipe line.
1047With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5
1048GIRLS HOSTEL GROUND FLOOR PLUMBING
1049Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:
1050White Vitreous China Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
1051Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked black solid plastic seat and lid
1052W.C. pan with ISI marked black solid plastic seat and lid
1053Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
1054White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
1055Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.
1056Rectangular shape 453x357mm dia.
1057Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge
1058Concealed work, including cutting chases and making good the walls etc.
105920 mm nominal outer dia Pipes
1060Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge
1061External work
106240 mm nominal outer dia Pipes
106350 mm nominal outer dia Pipes
1064Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
1065Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
1066Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.
1067With common burnt clay F.P.S( non-modular ) bricks of class designation 7.5
1068Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore
1069Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
1070100x100 mm size P type
1071With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5
1072GIRLS HOSTEL FIRST FLOOR PLUMBING
1073Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:
1074White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
1075Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked black solid plastic seat and lid
1076W.C. pan with ISI marked black solid plastic seat and lid
1077Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.
1078Rectangular shape 453x357mm dia.
1079Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge
1080Concealed work, including cutting chases and making good the walls etc.
108120 mm nominal outer dia Pipes
1082Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge
1083External work
108440 mm nominal outer dia Pipes
108550 mm nominal outer dia Pipes
1086Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
1087Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
1088Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore
1089Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
1090GIRLSHOSTEL GROUND FLOOR- INTERNAL ELECTRIFICATION
1091Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e. providing and fixing anchor made 5A flush type switches and all other accessories
1092a. Light point Short
1093b. Light point Medium
1094c. Light point Long
1095d. Call bell Point Long
1096e. Fan point medium
1097f. Exhaust fan point medium
1098Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc.
1099a. Medium point
1100b. Long point
1101Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc.
1102a. Medium point
1103b. Long point
1104Wiring for circuit/sub-main with PVC insulated copper cable core in surface casing capping etc.
1105a. With 1.5 mm2 copper cable s/core
1106b. With 2.5 mm2 copper cable s/core
1107c. with 4 mm2 copper cable s/core
1108d. With 6mm2 copper cable s/core
1109e. With 10mm2 copper cable s/core
1110f. With 1mm copper cable s/core for earth continuity
1111Fixing & Providing, Drilling holes and connection etc
1112a. MCB 10A
1113b. MCB 16A
1114c. MCB 20A
1115d. Isolator 40 Amp 2 pole
1116e. Isolator 63 Amp 2 pole
1117f. MCB Box 10 ways
1118g. MCB Box 12 ways
1119h. Main Switch 100A
1120i. Bus-Bar 100A 4 strips
1121j. TPN 100A
1122k. Change over Switch 100A
1123l. Angle holder
1124m. Bracket holder
1125n. LED Double tube light fitting 2x40wx4 with all accessories
1126o. Exhaust fan with all accessories
1127p. LED bulb 9w
1128q. Call Bell Ding Dong
1129r. Bulk head fitting with all accessories
1130Providing & fixing, drilling holes and connection etc.
1131a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal, salt etc.as required. The depth of the pit shall be atleast 3m or as per moisture availability.
1132b. Copper wire 4sq.mm
1133c. Lightning arrester
1134d. Panel Board
1135e.100 Sq.mm Al. LT. Power Cable
1136Supplying and installing Energy Meter
1137Armed cablefor Main 4 core X 10 Sqmm for Building
1138Armed cablefor Main 4 core X 4 Sqmm for Building
1139Armed cablefor Main 4 core X 35 Sqmm for Building
1140Supplying and installing Water Purifier
1141GIRLSHOSTEL FIRSTFLOOR- INTERNAL ELECTRIFICATION
1142Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e. providing and fixing anchor made 5A flush type switches and all other accessories
1143a. Light point Short
1144b. Light point Medium
1145c. Light point Long
1146d. Call bell Point Long
1147e. Fan point medium
1148f. Exhaust fan point medium
1149Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc.
1150a. Medium point
1151b. Long point
1152Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc.
1153a. Medium point
1154b. Long point
1155Wiring for circuit/sub-main with PVC insulated copper cable core in surface casing capping etc.
1156a. With 1.5 mm2 copper cable s/core
1157b. With 2.5 mm2 copper cable s/core
1158c. with 4 mm2 copper cable s/core
1159d. With 6mm2 copper cable s/core
1160e. With 10mm2 copper cable s/core
1161f. With 1mm copper cable s/core for earth continuity
1162Fixing & Providing, Drilling holes and connection etc
1163a. MCB 10A
1164b. MCB 16A
1165c. MCB 20A
1166d. Isolator 40 Amp 2 pole
1167e. Isolator 63 Amp 2 pole
1168f. MCB Box 10 ways
1169g. MCB Box 12 ways
1170h. Main Switch 100A
1171i. Angle holder
1172j. Bracket holder
1173k. LED Double tube light fitting 2x40wx4 with all accessories
1174l. Exhaust fan with all accessories
1175m. LED bulb 9w
1176n. Call Bell Ding Dong
1177o. Bulk head fitting with all accessories
1178Providing & fixing, drilling holes and connection etc.

AI Tender Summary

OUR REF NO 45322716
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 14.96 Crore
LAST DATE 25-10-2024
Authority
Authority Name Directorate Of School Education
Work Description Infrastructural Development Of Lighthouse School Complex (Lsc) - Government Higher Secondary School (Ghss) Medziphema Under Chumoukedima District
Basic Detail
Tender No IN-DSE-450253-CW-RFB
Bidding Type Tender
Location
City medziphema
State Nagaland
Key Dates
Publish Date 15 Oct 2024
Submission Date 25 Oct 2024
Open Date 25 Oct 2024
Finance
Tender Value 14.96 Crore
Tender Fee 15000
EMD 14.96 Lakhs
Exemption Not Available
Document List
RFB_LSC_Medziphema.pdf
Tendernotice_1.pdf
1276cdee-1d89-4ded-bdf5-5228579097e9.html
BOQ_814.xls
GHSS_Medziphema_Sec_II.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 25, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 25, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 25, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

RFB_LSC_Medziphema.pdf

pdf

Tendernotice_1.pdf

html

1276cdee-1d89-4ded-bdf5-5228579097e9.html

xls

BOQ_814.xls

pdf

GHSS_Medziphema_Sec_II.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders