Educational and Research Institute Statutory Bodies & Commissions/Committees Closing in 0 days TDR #45322714

Tender For Infrastructural Development Of Lighthouse School Complex (Lsc) - Government Higher Secondary School (Ghss) Tuensang Under Tuensang District

Issued by Statutory Bodies & Commissions/Committees · tuensang, Nagaland
Tender Value
18.08 Crore
Estimated cost
Bid Submission
25 Oct 2024
0 days left
EMD
18.08 Lakhs
Bank guarantee accepted
Document Fee
15000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tuensang → Nagaland
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Infrastructural Development Of Lighthouse School Complex (Lsc) - Government Higher Secondary School (Ghss) Tuensang Under Tuensang District

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Oct-2024 Corrigendum for LSC GHSS Tuensang under Tuensang District Date 25-Oct-2024

BOQ

Name of Work: Infrastructural Development of Lighthouse School Complex (LSC)- Government Higher Secondary School (GHSS) Tuensang under Tuensang District
Sl. No. Item Description
1ACADEMIC GROUND FLOOR CIVIL
2Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
3All kind of Soil
4Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
5Ordinary Rock
6Diluting and Injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)
7Treatment of soil under existing floors using.chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor.
8With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
10Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with comShamator burnt clay non-modular bricks:
111:4 (1 cement: 4 coarse sand)
12Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
131:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
14Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:
15Cement mortar 1:6 (1 cement : 6 coarse sand)
16Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous aggitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
17All works upto Plinth level
18All works above Plinth level upto floor V level
19Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 Cement 2 coarse sand 4 graded stone aggregate 12.5mm nominal size).
20Centering and shuttering including strutting, propping etc. anc removal of form work for:
21Foundations, footings, bases of Columns
22Centering and shuttering including strutting, propping etc. and removal of form for
23Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers
24Centering and shuttering including strutting, propping etc. and removal of form for
25Columns, Pillars, Piers, Abutments, Posts & Struts
26Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete above plinth level
27Hot Rolled deformed bars
28Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
29With F.P.S (Non Modular) bricks
30Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
31Cement mortar 1:4 (1 cement : 4 coarse sand)
32Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
33Second class teak wood
34Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-in charge and panelling with panels of: (Note: screws shall be paid separately) Butt hinges and necessary
3512 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
36Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-Charge. (Note: Butt hinges and necessary screws shall be paid separately)
37Second class Teak wood
3835mm thick shutters
39Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge.
40Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
4135 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
42Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
43100x75x4 mm
44Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
45250x16 mm
46Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
47200 * 10mm
48Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
49125 mm
50Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
51Twin rubber stopper
52Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
53Fixed to Opening / wooden frames with rawl plugs screws etc
54Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse)
5525 mm thick
56Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades.
578mm thick (mirror polished and machine cut edge)
58Granite stone of any colour and shade
59Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with:
60Udaipur green marble
61Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).
62Dark shade pigment using ordinary cement
63Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
64Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
65Size of Tile 600x600 mm
66Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
67Size of Tile 600x600 mm
68Providing Zinc Aluminium Alloy Galavanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto pitch of 60 degrees) excluding the cost of purlins, rafters and trusses.
690.50 mm thick
70Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
71Hot finished welded type tubes
7212 mm cement plaster of mix:
731:6 (1 cement :6 Coarse sand)
7420 mm cement plaster of mix:
751:6 (1 cement :6 Coarse sand)
766 mm cement plaster of mix:
77(1 cement: 3 fine sand)
78Applying priming coat
79With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood)
80Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant.
81Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
82With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
83Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
84Painting with synthetic enamel paint of approval brand and manufacture to give an even shade es
85Two or more coats on new work
86Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:
87New work ( Two or more coats) over and including priming coat with water thinnable cement primer
88Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content less than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.
89Two Coats
90Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
91Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately)
92For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for separately)
93Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
94Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
95Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item)
96With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
97Providing 10mm thick plaster of Paris (gypsum anhydrous) ceiling upto a height of 5m above floor level, over first class kail wood strips 25x6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be pald separately):
98Flat surfaces
99Providing expansion joints with 25mm thick bituminous pad as per detailed drawings etc. complete
100ACADEMIC FIRST FLOOR CIVIL
101Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous aggitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable seperately)
102All works above Plinth level upto floor V level
103Centering and shuttering including strutting, propping etc. and removal of form for
104Lintles, Beams, Plinth beams, Girders, Bressumers & Cantilevers
105Centering and shuttering including strutting, propping etc. and removal of form for
106Columns, Pillars, Piers, Abutments, Posts & Struts
107Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
108Hot Rolled deformed bars
109Brick work with comShamator burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
110With F.P.S (Non Modular) bricks
111Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
112Cement mortar 1:4 (1 cement : 4 coarse sand)
113Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
114Second class teak wood
115Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary
11612 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthtic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
117Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-Charge. (Note: Butt hinges and necessary screws shall be paid seperately)
118Second class Teak wood
11935mm thick shutters
120Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-
121Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
12235 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
123Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
124100x75x4 mm
125Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
126250x16 mm
127Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
128200 * 10mm
129Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
130125 mm
131Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
132Twin rubber stopper
133Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
134Fixed to Opening / wooden frames with rawl plugs screws etc
135Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse)
13625 mm thick
137Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades.
1388mm thick (mirror polished and machine cut edge)
139Granite stone of any colour and shade
140Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with:
141Udaipur green marble
142Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
143Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorbtion less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
144Size of Tile 600x600 mm
145Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
146Size of Tile 600x600 mm
147Providing Zinc Aluminium Alloy Galavanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto pitch of 60 degrees) excluding the cost of purlins, rafters and trusses.
1480.50 mm thick
149Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
150Hot finished welded type tubes
15112 mm cement plaster of mix:
1521:6 (1 cement :6 Coarse sand)
15320 mm cement plaster of mix:
1541:6 (1 cement :6 Coarse sand)
1556 mm cement plaster of mix:
156(1 cement: 3 fine sand)
157Applying priming coat
158With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood)
159Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant.
160Applying priming coatwith primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
161With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
162Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
163Painting with synthetic enamel paint of approval brand and manufacture to give an even shade es
164Two or more coats on new work
165Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:
166New work ( Two or more coats) over and including priming coat with water thinnable cement primer
167Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.
168Two Coats
169Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
170Providing and fixing aluminium work for doors, windows, ventilators and partitions with extrudued built up standard tubular sections/ appropiate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately)For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
171For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
172Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
173Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item)
174With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
175Providing 10mm thick plaster of paris (gypsum anhydrous) ceiling upto a height of 5m above floor level, over first class kail wood strips 25x6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be pald separately):
176Flat surfaces
177Providing expansion joints with 25mm thick bituminous pad as per detailed drawings etc. complete
178ACADEMIC SECOND FLOOR CIVIL
179Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous aggitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable seperately)
180All works above Plinth level upto floor V level
181Centering and shuttering including strutting, propping etc. and removal of form for
182Lintles, Beams, Plinth beams, Girders, Bressumers & Cantilevers
183Centering and shuttering including strutting, propping etc. and removal of form for
184Columns, Pillars, Piers, Abutments, Posts & Struts
185Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
186Hot Rolled deformed bars
187Brick work with comShamator burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
188With F.P.S (Non Modular) bricks
189Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
190Cement mortar 1:4 (1 cement : 4 coarse sand)
191Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
192Second class teak wood
193Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary
19412 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthtic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
195Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-Charge. (Note: Butt hinges and necessary screws shall be paid seperately)
196Second class Teak wood
19735mm thick shutters
198Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-
199Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
20035 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
201Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
202100x75x4 mm
203Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
204250x16 mm
205Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
206200 * 10mm
207Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
208125 mm
209Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
210Twin rubber stopper
211Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
212Fixed to Opening / wooden frames with rawl plugs screws etc
213Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse)
21425 mm thick
215Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades.
2168mm thick (mirror polished and machine cut edge)
217Granite stone of any colour and shade
218Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with:
219Udaipur green marble
220Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
221Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorbtion less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
222Size of Tile 600x600 mm
223Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
224Size of Tile 600x600 mm
225Providing Zinc Aluminium Alloy Galavanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto pitch of 60 degrees) excluding the cost of purlins, rafters and trusses.
2260.50 mm thick
227Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
228Hot finished welded type tubes
22912 mm cement plaster of mix:
2301:6 (1 cement :6 Coarse sand)
23120 mm cement plaster of mix:
2321:6 (1 cement :6 Coarse sand)
2336 mm cement plaster of mix:
234(1 cement: 3 fine sand)
235Applying priming coat
236With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood)
237Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant.
238Applying priming coatwith primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
239With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
240Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
241Painting with synthetic enamel paint of approval brand and manufacture to give an even shade es
242Two or more coats on new work
243Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:
244New work ( Two or more coats) over and including priming coat with water thinnable cement primer
245Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.
246Two Coats
247Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
248Providing and fixing aluminium work for doors, windows, ventilators and partitions with extrudued built up standard tubular sections/ appropiate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately)For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
249For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
250Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
251Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item)
252With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
253Providing 10mm thick plaster of paris (gypsum anhydrous) ceiling upto a height of 5m above floor level, over first class kail wood strips 25x6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be pald separately):
254Flat surfaces
255Providing expansion joints with 25mm thick bituminous pad as per detailed drawings etc. complete
256COMPOUND WALL PART A
257Earth work in excavation by mechanical means (Hydraulic excavator/Manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m. All Kinds of soil
258All kind of Soil
259Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
2601:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
261Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous aggitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
262All works upto Plinth level
263All works above Plinth level upto floor V level
264Centering and shuttering including strutting, propping etc. an removal of form work for:
265Foundations, footings, bases of Columns
266Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
267Hot Rolled deformed bars
268Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
269With FPS( Non Modular) bricks
270Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
271Second class teak wood
272Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary
27312 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthtic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
274Providing and fixing aluminium work for doors, windows, ventilators and partitions with extrudued built up standard tubular sections/ appropiate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ satinless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately)
275For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
276Anodised aliminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
277Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of alimunium snap beading shall be paid in basic item)
278With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
27915 mm cement plaster on the rough side of single or half brick wall of mix:
2801:4 (1 cement :4 fine sand)
281Applying priming coatwith primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
282With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
283Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.Two Coats
284Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
285Hot finished welded type tubes
286COMPOUND WALL PART B
287Earth work in excavation by mechanical means (Hydraulic excavator/Manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m.
288All Kinds of soil
289Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous aggitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable seperately)
290All works upto Plinth level
291Providing and fixing G.I Chain Link Fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-Charge
292Made of G.I wire of dia 4mm
293Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete
294Providing and Fixing Barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete.
295W.B.M ROAD
296Excavation in Soil using Hydraulic Excavator and Tippers with Disposal upto 1000 metres. Unit Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and across sections, and transporting to the embankment location within all lifts and lead upto 1000m
297Compacting Original Ground Arounds Loosening of the ground upto a level of 500 mm below the sub grade level, watered, graded and compacted in layers to meet the requirement of table 300-2 for sub-grade construction
298Compacting Original Ground supporting sub-grade
299Compacting Original Ground supporting Embankment
300Construction of granular sub-base by providing granular material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory power roller to achieve the desired density, complete as per clause 401
301By Mix in Place Method
302Granular Sub-Base Grading-I Material
303Granular Sub-Base Grading-II Material
304Granular Sub-Base Grading-III Material
305Water Bound Macadam
306Providing, laying, spreding and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/binding materials to fill up the interstices of coarse aggregate, watering and compacting to required density
307By Manual Means
308Grading II
309Using Screening Crushable type such as Moorum or Gravel
310Grading III
311Using Screening Crushable type such as Moorum or Gravel
312Prime Coat
313Prime Coat over WMM / WBM
314Providing and applying primer coat with SS1 grade bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sum using mechanical means.
315Tack Coat
316Tack Coat on Bituminous surfaces
317Providing and applying tack coat with bitumen ernulsion using emulsion pressure distributor at the rate of 0.20 kg per sum on the prepared bituminous surface cleaned with mechanical broom.
318Bituminous Macadam Grading -I
319Providing and laying bituminous macadam with higher capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction
320Bituminous Macadam Grading -II
321Providing and laying bituminous macadam with higher capacity hot mix plant using crushed aggregates of specified grading ipremixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the reguired grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction
322Surface Dressing
323Providing and laying surface dressing as wearing course in single coat using crushed stone aggregates of specified size on a layer of bituminous binder laid on prepared surface and rolling with 8- 10 tonne smooth wheeled steel roller
32413 mm nominal chipping size
325Seal Coat Description Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats
326Type A
327Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:
328600mm dia R.C.C. Pipe
329Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
3301:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
331Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
332With FPS( Non Modular) bricks
33312 mm cement plaster finished with floating coat of neat cement of mix
3341:4 (1 cement :4 Fine sand)
335UNDER GROUND TANK 1
336Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
337All kind of Soil
338Extra for every additonal lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials.
339All Kinds of soil
340Extra for every additonal lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials.
341Ordinary or Hard Rock
342Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with comShamator burnt clay non-modular bricks:
3431:4 (1 cement: 4 coarse sand)
344Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
3451:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
346Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous aggitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
347All works upto Plinth level
348Centering and shuttering including strutting, propping etc. anc removal of form work for:
349Foundations, footings, bases of Columns
350Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
351Hot Rolled deformed bars
352Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
353Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) as per standard design.
354With 20 mm diameter round bar
355Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality.
356LD-2.5
357Rectangular shape 600x450mm internal dimensions
358UNDER GROUND TANK 2
359Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
360All kind of Soil
361Extra for every additonal lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials.
362All Kinds of soil
363Extra for every additonal lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials.
364Ordinary or Hard Rock
365Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with comShamator burnt clay non-modular bricks:
3661:4 (1 cement: 4 coarse sand)
367Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
3681:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
369Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous aggitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
370All works upto Plinth level
371Centering and shuttering including strutting, propping etc. anc removal of form work for:
372Foundations, footings, bases of Columns
373Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
374Hot Rolled deformed bars
375Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
376Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) as per standard design.
377With 20 mm diameter round bar
378Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality.
379LD-2.5
380Rectangular shape 600x450mm internal dimensions
381UNDER GROUND TANK 3
382Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
383All kind of Soil
384Extra for every additonal lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials.
385All Kinds of soil
386Extra for every additonal lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials.
387Ordinary or Hard Rock
388Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with comShamator burnt clay non-modular bricks:
3891:4 (1 cement: 4 coarse sand)
390Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
3911:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
392Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous aggitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
393All works upto Plinth level
394Centering and shuttering including strutting, propping etc. anc removal of form work for:
395Foundations, footings, bases of Columns
396Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
397Hot Rolled deformed bars
398Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
399Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) as per standard design.
400With 20 mm diameter round bar
401Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality.
402LD-2.5
403Rectangular shape 600x450mm internal dimensions
404LANDSCAPING WORK
405Planting of Trees and their Maintenance for one Year
406Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year
407Tree Guard with MS Angle Iron and Steel Wire
408Providing and fixing tree guard 0.60 metre square, 2.00 metre high fabricated with MS angle iron 30 x 30 x 3 mm, MS iron 25 x 3; mm and steel wire3 mm dia welded and fabricated as per design in two halves bolted together
409SEPTIC TANK 1
410Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
411All kind of Soil
412Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
413Ordinary Rock
414Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
4151:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
416Reinforced cement concrete work in walls (any thickness), Including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement.
4171:1.5:3 (1 Cement: 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size)
418Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
419Hot Rolled deformed bars
420Brick work with comShamator burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
421With F. P. S. (non modular) bricks
42212 mm cement plaster finished with floating coat of neat cement of mix
4231:4 (1 cement :4 Fine sand)
424Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
425Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
426Inside dimensions 600x850 mm and 45 cm deep for single pipe tine.
427With commom burnt clay F.P.S. (non modular) bricks of class designation 7.5
428SEPTIC TANK 2
429Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
430All kind of Soil
431Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
432Ordinary Rock
433Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
4341:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
435Reinforced cement concrete work in walls (any thickness), Including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement.
4361:1.5:3 (1 Cement: 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size)
437Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
438Hot Rolled deformed bars
439Brick work with comShamator burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
440With F. P. S. (non modular) bricks
44112 mm cement plaster finished with floating coat of neat cement of mix
4421:4 (1 cement :4 Fine sand)
443Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
444Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
445Inside dimensions 600x850 mm and 45 cm deep for single pipe tine.
446With commom burnt clay F.P.S. (non modular) bricks of class designation 7.5
447RAINWATER HARVESTING
448Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
449All kind of Soil
450Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
4511:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
45212 mm cement plaster finished with a floating coat of neat cement of mix:
4531:3 (1 cement :4 fine sand)
454Brick work with comShamator burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
455With FPS( Non Modular) bricks
456Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7mmconfirming to I.S. 13592-1992 including proper rainwater receiving recesswithP.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inludingfixingthepipeonwallusingapprovedwoodencleatsprojecting 25mmto40mmfromfaceofwallafixingwithclipsofapprovedqualityandOneNumber ,filingthejointusingrubbergasketwith solvent cement and properly resting the shoe of pipes onC.C. ormasonryblocks, includingnecessaryscaffoldingandmaintenance for3yrsforanyleakagesordislocationsofpipes.AlltheP.V.C.fittingsandadditional2 piece socket clips shall be got approved from engineer in charge etc. complete.
457Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and havingwall thickness of 2.2 to 2.7mmconfirming to I.S. 13592-1992 including proper rainwater receiving recesswithP.V.C. plug, bend, necessaryfittings, suchas, offsets, shoes, inludingfixingthepipeonwallusingapprovedwoodencleatsprojecting 25mmto40mmfromfaceofwallafixingwithclipsofapprovedqualityandOneNumber ,filingthejointusingrubbergasketwith solventcement and properly resting the shoe of pipes onC.C. ormasonryblocks, includingnecessaryscaffoldingandmaintenance for3yrsforanyleakagesordislocationsofpipes.AlltheP.V.C.fittingsandadditional2 piece socket clips shall be got approved from engineer in charge etc. complete.
458DEMOLITION AND RETROFITTING WORK OF EXISTING BLOCK
459Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
460Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge.
461In cement mortar
462Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:
463Of area 3 sq. metres and below
464Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, racking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish of the dumping ground, all complete as per the direction of Engineer-in-charge
465With cement mortar 1:4 (1 cement: 4 fine sand)
466Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
467For thickness of tiles 10 mm to 25 mm
468Brick work with comShamator burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
469With FPS( Non Modular) bricks
470Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
471Size of Tile 600x600 mm
472Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
473Size of Tile 600x600 mm
474Painting with synthetic enamel paint of approval brand and manufacture to give an even shade es
475Two or more coats on new work
476Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:
477New work ( Two or more coats) over and including priming coat with water thinnable cement primer
478Providing and laying insitu / ready mix M25 grade RCC jacketing work around the existing COLUMN, BEAM ,SLAB etc.complete. (with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer with fine agreegates of required specifications ( VSI sand finely washed etc ), height of 8 to 10 meter)
479Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
480Hot Rolled deformed bars
481PLUMBING GROUND FLOOR
482Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931
48315 mm nominal bore
484Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:
485White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
486Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
487W.C. pan with ISI marked black solid plastic seat and lid
488Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.1. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:
489Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
490Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
491White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
492Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.
493Rectangular shape 453x357mm dia.
494Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge
495Concealed work, including cutting chases and making good the walls etc.
49620 mm nominal outer dia Pipes
497Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge
498External work
49940 mm nominal outer dia Pipes
50050 mm nominal outer dia Pipes
501Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slottedvent, clamps etc. complete
502Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slottedvent, clamps etc. complete.
503Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.
504With commonburnt clay F.P.S( non modular )bricks of class designation 7.5
505Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore
506Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
507100x100 mm size P type
508With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
509PLUMBING FIRST FLOOR
510Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931
51115 mm nominal bore
512Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:
513White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
514Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
515W.C. pan with ISI marked black solid plastic seat and lid
516Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.1. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:
517Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
518Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
519White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
520Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.
521Rectangular shape 453x357mm dia.
522Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge
523Concealed work, including cutting chases and making good the walls etc.
52420 mm nominal outer dia Pipes
525Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge
526External work
52740 mm nominal outer dia Pipes
52850 mm nominal outer dia Pipes
529Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slottedvent, clamps etc. complete
530Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slottedvent, clamps etc. complete.
531Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
53215 mm nominal bore
533Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
534PLUMBING SECOND FLOOR
535Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931
53615 mm nominal bore
537Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:
538White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
539Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
540W.C. pan with ISI marked black solid plastic seat and lid
541Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.1. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:
542Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
543Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
544White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
545Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.
546Rectangular shape 453x357mm dia.
547Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge
548Concealed work, including cutting chases and making good the walls etc.
54920 mm nominal outer dia Pipes
550Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge
551External work
55240 mm nominal outer dia Pipes
55350 mm nominal outer dia Pipes
554Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slottedvent, clamps etc. complete
555Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slottedvent, clamps etc. complete.
556Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
55715 mm nominal bore
558Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
559FIRE FIGHTING GROUND FLOOR
560Supplying,installing,testingandcommissioningopticaltype smoke detector complete on box as per specification no.FFFAS/ SD
561Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
562ground floor to first
563SupplyingandinstallingwallmountingswingingHosereel drumfittedwith19mmdia.30meterhighpressure polypropylene(Polyhouse)longfittedwithnecessaryaccessoriescomplete as per specification no. FF-FFA/HV
564CO2 EXTINGUISHER
565ABC EXTINGUISHER
566Hooter
567Manual Call Point
568Fire Alarm Control Panel
569Fire Pump
570Butter fly valve
571FIRE FIGHTING FIRST FLOOR
572Supplying,installing,testingandcommissioningopticaltype smoke detector complete on box as per specification no.FFFAS/ SD
573Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
574SupplyingandinstallingwallmountingswingingHosereel drumfittedwith19mmdia.30meterhighpressure polypropylene(Polyhouse)longfittedwithnecessaryaccessoriescomplete as per specification no. FF-FFA/HV
575CO2 EXTINGUISHER
576ABC EXTINGUISHER
577Hooter
578Manual Call Point
579Fire Alarm Control Panel
580Butter fly valve
581FIRE FIGHTING SECOND FLOOR
582Supplying,installing,testingandcommissioningopticaltype smoke detector complete on box as per specification no.FFFAS/ SD
583Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
584SupplyingandinstallingwallmountingswingingHosereel drumfittedwith19mmdia.30meterhighpressure polypropylene(Polyhouse)longfittedwithnecessaryaccessoriescomplete as per specification no. FF-FFA/HV
585CO2 EXTINGUISHER
586ABC EXTINGUISHER
587Hooter
588Manual Call Point
589Fire Alarm Control Panel
590Butter fly valve
591INTERNAL ELECTRIFICATION GROUND FLOOR
592Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e providing and fixing anchor made 5A flush type switches and all other accessories
593a. Light point Short
594b. Light point Medium
595c. Light point Long
596d. Call bell Point Long
597e. Fan point medium
598f. Exhaust fan point medium
599Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc.
600a. Medium point
601b. Long point
602Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc.
603a. Medium point
604b. Long point
605Wiring for circuit/sub-main with pvc insulated copper cable core in surface casing capping etc.
606a. With 1.5 mm2 copper cable s/core
607b. With 2.5 mm2 copper cable s/core
608c. with 4 mm2 copper cable s/core
609d. With 6mm2 copper cable s/core
610e. With 10mm2 copper cable s/core
611f. With 1mm copper cable s/core for earth continuity
612Fixing & Providing, Drilling holes and connection etc
613a. MCB 10A
614b. MCB 16A
615c. MCB 20A
616d. Isolator 40 Amp 2 pole
617e. Isolator 63 Amp 2 pole
618f. MCB Box 10 ways
619g. MCB Box 12 ways
620i. Main Switch 100A
621j. Bus-Bar 100A 4 strips
622k. TPN 100A
623l. Change over Switch 100A
624m. Angle holder
625n. Bracket holder
626o. LED Double tube light fitting 2x40wx4 with all accessories
627q. Exhaust fan with all accessories
628s. LED bulb 9w
629t. Call Bell Ding Dong
630u. Bulk head fitting with all accessories
631Providing & fixing, drilling holes and connection etc.
632a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal,salt etc.as requiresd. The depth of the pit shall be atleast 3m or as per moisture availability.
633b. Copper wire 4sq.mm
634c. Lightning arrester
635d. Panel Board
636e.100 Sq.mm Al. LT. Power Cable
637Energy Meter
638Armed cablefor Main 4 core X 10 Sqmm for Building
639Armed cablefor Main 4 core X 4 Sqmm for Building
640Armed cablefor Main 4 core X 35 Sqmm for Building
641Water Purify
6425 KVA UPS
643INTERNAL ELECTRIFICATION FIRST FLOOR
644Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e providing and fixing anchor made 5A flush type switches and all other accessories
645a. Light point Short
646b. Light point Medium
647c. Light point Long
648d. Call bell Point Long
649e. Fan point medium
650f. Exhaust fan point medium
651Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc.
652a. Medium point
653b. Long point
654Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc.
655a. Medium point
656b. Long point
657Wiring for circuit/sub-main with pvc insulated copper cable core in surface casing capping etc.
658a. With 1.5 mm2 copper cable s/core
659b. With 2.5 mm2 copper cable s/core
660c. with 4 mm2 copper cable s/core
661d. With 6mm2 copper cable s/core
662e. With 10mm2 copper cable s/core
663f. With 1mm copper cable s/core for earth continuity
664Fixing & Providing, Drlling holes and connection etc
665a. MCB 10A
666b. MCB 16A
667c. MCB 20A
668d. Isolator 40 Amp 2 pole
669e. Isolator 63 Amp 2 pole
670f. MCB Box 10 ways
671g. MCB Box 12 ways
672i. Main Switch 100A
673m. Angle holder
674n. Bracket holder
675o. LED Double tube light fitting 2x40wx4 with all accessories
676q. Exhaust fan with all accessories
677s. LED bulb 9w
678t. Call Bell Ding Dong
679u. Bulk head fitting with all accessories
680Providing & fixing, drilling holes and connection etc.
681a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal,salt etc.as requiresd. The depth of the pit shall be atleast 3m or as per moisture availability.
682b. Copper wire 4sq.mm
683c. Lightning arrester
684d. Panel Board
685Water Purify
6865 KVA UPS
687INTERNAL ELECTRIFICATION SECOND FLOOR
688Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e providing and fixing anchor made 5A flush type switches and all other accessories
689a. Light point Short
690b. Light point Medium
691c. Light point Long
692d. Call bell Point Long
693e. Fan point medium
694f. Exhaust fan point medium
695Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc.
696a. Medium point
697b. Long point
698Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc.
699a. Medium point
700b. Long point
701Wiring for circuit/sub-main with pvc insulated copper cable core in surface casing capping etc.
702a. With 1.5 mm2 copper cable s/core
703b. With 2.5 mm2 copper cable s/core
704c. with 4 mm2 copper cable s/core
705d. With 6mm2 copper cable s/core
706e. With 10mm2 copper cable s/core
707f. With 1mm copper cable s/core for earth continuity
708Fixing & Providing, Drlling holes and connection etc
709a. MCB 10A
710b. MCB 16A
711c. MCB 20A
712d. Isolator 40 Amp 2 pole
713e. Isolator 63 Amp 2 pole
714f. MCB Box 10 ways
715g. MCB Box 12 ways
716i. Main Switch 100A
717m. Angle holder
718n. Bracket holder
719o. LED Double tube light fitting 2x40wx4 with all accessories
720q. Exhaust fan with all accessories
721s. LED bulb 9w
722t. Call Bell Ding Dong
723u. Bulk head fitting with all accessories
724Providing & fixing, drilling holes and connection etc.
725a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal,salt etc.as requiresd. The depth of the pit shall be atleast 3m or as per moisture availability.
726b. Copper wire 4sq.mm
727c. Lightning arrester
728d. Panel Board
729Water Purify
7305 KVA UPS
731EXTERNAL ELECTRIFICATION
732Fixing & Providing, Drilling holes and connection etc
733a. MCB 20A
734b. Isolator 63 Amp 2 pole
735c. Main Switch 100A
736d. Bus-Bar 100A 4 strips
737e. TPN 100A
738f. Change over Switch 100A
739g. 60 watt LED for street Light
740h. Pole
741i. Pole Arm
742a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal, salt etc.as required. The depth of the pit shall be at least 3m or as per moisture availability.
743b. Copper wire 4sq.mm
744c. Lightning arrester
745d. Panel Board
746e.100 Sq.mm Al. LT. Power Cable
747Supplying and installing Energy Meter
748Armed cablefor Main 4 core X 10 Sqmm for Street light
749Supplying and installing 30 KVA DG Set
750BOYS HOSTEL GROUND FLOOR CIVIL
751Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
752All kind of Soil
753Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
754Ordinary Rock
755Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)
756Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor. With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
757With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
758Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
759Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with common burnt clay non-modular bricks:
7601:4 (1 cement: 4 coarse sand)
761Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
7621:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
763Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
764All works upto Plinth level
765All works above Plinth level upto floor V level
766Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 Cement 2 coarse sand 4 graded stone aggregate 12.5mm nominal size).
767Centering and shuttering including strutting, propping etc. and removal of form work for:
768Foundations, footings, bases of Columns
769Centering and shuttering including strutting, propping etc. and removal of form for
770Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers
771Centering and shuttering including strutting, propping etc. and removal of form for
772Columns, Pillars, Piers, Abutments, Posts & Struts
773Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses.
7740.50 mm thick
775Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
776Hot finished welded type tubes
777Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
778Hot Rolled deformed bars
779Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
780With F. P. S. (non-modular) bricks
781Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
782Cement mortar 1:4 (1 cement : 4 coarse sand)
783Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
784Second class teak wood
785Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
78612 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
787Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-Charge. (Note: Butt hinges and necessary screws shall be paid seperately)
788Second class Teak wood
78930mm thick shutters
790Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge.
791Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
79235 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
793Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
794100x75x4 mm
795Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
796250x16 mm
797Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
798200 * 10mm
799Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
800125 mm
801Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
802Twin rubber stopper
803Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
804Fixed to opening/ wooden frames with rawl plugs screws etc.
805Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse 25 mm thick
80625 mm thick
807Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades.
8088mm thick (mirror polished and machine cut edge)
809Granite stone of any colour and shade
810Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with:
811Udaipur green marble
812Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
813Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
814Size of Tile 600x600 mm
815Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
816Size of Tile 600x600 mm
81712 mm cement plaster of mix:
8181:6 (1 cement :6 Coarse sand)
81920 mm cement plaster of mix:
8201:6 (1 cement :6 Coarse sand)
8216 mm cement plaster of mix:
822(1 cement: 3 fine sand)
823Applying priming coat
824With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood)
825Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant.
826Painting with synthetic enamel paint of approval brand and manufacture to give an even shade
827Two or more coats on new work
828Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
829Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
830With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
831Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.
832Two Coats
833Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
834Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately)
835For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
836Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
837Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item)
838With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
839Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
840BOYS HOSTEL FIRST FLOOR CIVIL
841Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
842All works above Plinth level upto floor V level
843Centering and shuttering including strutting, propping etc. and removal of form for
844Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers
845Centering and shuttering including strutting, propping etc. and removal of form for
846Columns, Pillars, Piers, Abutments, Posts & Struts
847Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
848Hot Rolled deformed bars
849Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
850With F. P. S. (non-modular) bricks
851Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
852Cement mortar 1:4 (1 cement : 4 coarse sand)
853Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
854Second class teak wood
855Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
85612 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
857Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge.
858Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
85935 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
860Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
861100x75x4 mm
862Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
863250x16 mm
864Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
865200 * 10mm
866Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
867125 mm
868Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
869Twin rubber stopper
870Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
871Fixed to opening/ wooden frames with rawl plugs screws etc.
872Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades.
8738mm thick (mirror polished and machine cut edge)
874Granite stone of any colour and shade
875Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with:
876Udaipur green marble
877Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
878Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
879Size of Tile 600x600 mm
880Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
881Size of Tile 600x600 mm
882Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses.
8830.50 mm thick
884Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
885Hot finished welded type tubes
88612 mm cement plaster of mix:
8871:6 (1 cement :6 Coarse sand)
88820 mm cement plaster of mix:
8891:6 (1 cement :6 Coarse sand)
890Applying priming coat
891With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood)
892Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant.
893Painting with synthetic enamel paint of approval brand and manufacture to give an even shade
894Two or more coats on new work
895Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
896Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
897With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
898Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.
899Two Coats
900Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately)
901For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
902Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
903Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item)
904With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
905Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
906BOYS HOSTEL SEPTIC TANK
907Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
908All kind of Soil
909Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
910Ordinary Rock
911Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
9121:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
913Reinforced cement concrete work in walls (any thickness), Including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.
9141:1.5:3 (1 Cement: 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size)
915Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
916Hot Rolled deformed bars
917Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
918With F. P. S. (non-modular) bricks
91912 mm cement plaster finished with floating coat of neat cement of mix
9201:4 (1 cement :4 Fine sand)
921Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
922Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
923Inside dimensions 600x850 mm and 45 cm deep for single pipe line.
924With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5
925BOYS HOSTEL GROUND FLOOR PLUMBING
926Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931
92715 mm nominal bore
928Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:
929White Vitreous China Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
930Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked black solid plastic seat and lid
931W.C. pan with ISI marked black solid plastic seat and lid
932Providing and fixing white vitreous China flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.1. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:
933Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
934Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
935White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
936Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.
937Rectangular shape 453x357mm dia.
938Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge
939Concealed work, including cutting chases and making good the walls etc.
94020 mm nominal outer dia Pipes
941Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge
942External work
94340 mm nominal outer dia Pipes
94450 mm nominal outer dia Pipes
945Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
946Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
947Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.
948With common burnt clay F.P.S( non-modular ) bricks of class designation 7.5
949Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore
950Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
951100x100 mm size P type
952With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5
953BOYS HOSTEL FIRST FLOOR PLUMBING
954Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931
95515 mm nominal bore
956Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:
957White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
958Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked black solid plastic seat and lid
959W.C. pan with ISI marked black solid plastic seat and lid
960Providing and fixing white vitreous China flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.1. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:
961Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
962Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.
963Rectangular shape 453x357mm dia.
964Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge
965Concealed work, including cutting chases and making good the walls etc.
96620 mm nominal outer dia Pipes
967Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge
968External work
96940 mm nominal outer dia Pipes
97050 mm nominal outer dia Pipes
971Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
972Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
973Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore
974Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
975BOYES HOSTEL GROUND FLOOR INTERNAL ELECTRIFICATION
976Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e. providing and fixing anchor made 5A flush type switches and all other accessories
977a. Light point Short
978b. Light point Medium
979c. Light point Long
980d. Call bell Point Long
981e. Fan point medium
982f. Exhaust fan point medium
983Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc.
984a. Medium point
985b. Long point
986Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc.
987a. Medium point
988b. Long point
989Wiring for circuit/sub-main with PVC insulated copper cable core in surface casing capping etc.
990a. With 1.5 mm2 copper cable s/core
991b. With 2.5 mm2 copper cable s/core
992c. with 4 mm2 copper cable s/core
993d. With 6mm2 copper cable s/core
994e. With 10mm2 copper cable s/core
995f. With 1mm copper cable s/core for earth continuity
996Fixing & Providing, Drilling holes and connection etc
997a. MCB 10A
998b. MCB 16A
999c. MCB 20A
1000d. Isolator 40 Amp 2 pole
1001e. Isolator 63 Amp 2 pole
1002f. MCB Box 10 ways
1003g. MCB Box 12 ways
1004h. Main Switch 100A
1005i. Bus-Bar 100A 4 strips
1006j. TPN 100A
1007k. Change over Switch 100A
1008l. Angle holder
1009m. Bracket holder
1010n. LED Double tube light fitting 2x40wx4 with all accessories
1011o. Exhaust fan with all accessories
1012p. LED bulb 9w
1013q. Call Bell Ding Dong
1014r. Bulk head fitting with all accessories
1015Providing & fixing, drilling holes and connection etc.
1016a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal, salt etc.as required. The depth of the pit shall be atleast 3m or as per moisture availability.
1017b. Copper wire 4sq.mm
1018c. Lightning arrester
1019d. Panel Board
1020e.100 Sq.mm Al. LT. Power Cable
1021Supplying and installing Energy Meter
1022Armed cablefor Main 4 core X 10 Sqmm for Building
1023Armed cablefor Main 4 core X 4 Sqmm for Building
1024Armed cablefor Main 4 core X 35 Sqmm for Building
1025Supplying and installing Water Purifier
1026BOY\"S HOSTEL FIRST FLOOR INTERNAL ELECTRIFICATION
1027Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e. providing and fixing anchor made 5A flush type switches and all other accessories
1028a. Light point Short
1029b. Light point Medium
1030c. Light point Long
1031d. Call bell Point Long
1032e. Fan point medium
1033f. Exhaust fan point medium
1034Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc.
1035a. Medium point
1036b. Long point
1037Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc.
1038a. Medium point
1039b. Long point
1040Wiring for circuit/sub-main with PVC insulated copper cable core in surface casing capping etc.
1041a. With 1.5 mm2 copper cable s/core
1042b. With 2.5 mm2 copper cable s/core
1043c. with 4 mm2 copper cable s/core
1044d. With 6mm2 copper cable s/core
1045e. With 10mm2 copper cable s/core
1046f. With 1mm copper cable s/core for earth continuity
1047Fixing & Providing, Drilling holes and connection etc
1048a. MCB 10A
1049b. MCB 16A
1050c. MCB 20A
1051d. Isolator 40 Amp 2 pole
1052e. Isolator 63 Amp 2 pole
1053f. MCB Box 10 ways
1054g. MCB Box 12 ways
1055h. Main Switch 100A
1056i. Angle holder
1057j. Bracket holder
1058k. LED Double tube light fitting 2x40wx4 with all accessories
1059l. Exhaust fan with all accessories
1060m. LED bulb 9w
1061n. Call Bell Ding Dong
1062o. Bulk head fitting with all accessories
1063Providing & fixing, drilling holes and connection etc.
1064GIRLS HOSTEL GROUND FLOOR CIVIL
1065Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
1066All kind of Soil
1067Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
1068Ordinary Rock
1069Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)
1070Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor. With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
1071With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
1072Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
1073Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with common burnt clay non-modular bricks:
10741:4 (1 cement: 4 coarse sand)
1075Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
10761:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
1077Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
1078All works upto Plinth level
1079All works above Plinth level upto floor V level
1080Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 Cement 2 coarse sand 4 graded stone aggregate 12.5mm nominal size).
1081Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:
1082Cement mortar 1:6 (1 cement : 6 coarse sand)
1083Centering and shuttering including strutting, propping etc. and removal of form work for:
1084Foundations, footings, bases of Columns
1085Centering and shuttering including strutting, propping etc. and removal of form for
1086Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers
1087Centering and shuttering including strutting, propping etc. and removal of form for
1088Columns, Pillars, Piers, Abutments, Posts & Struts
1089Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses.
10900.50 mm thick
1091Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
1092Hot finished welded type tubes
1093Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
1094Hot Rolled deformed bars
1095Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
1096With F. P. S. (non-modular) bricks
1097Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
1098Cement mortar 1:4 (1 cement : 4 coarse sand)
1099Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
1100Second class teak wood
1101Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
110212 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
1103Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-Charge. (Note: Butt hinges and necessary screws shall be paid seperately)
1104Second class Teak wood
110530mm thick shutters
1106Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge.
1107Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
110835 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
1109Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
1110100x75x4 mm
1111Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
1112250x16 mm
1113Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
1114200 * 10mm
1115Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
1116125 mm
1117Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
1118Twin rubber stopper
1119Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
1120Fixed to opening/ wooden frames with rawl plugs screws etc.
1121Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse 25 mm thick
112225 mm thick
1123Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades.
11248mm thick (mirror polished and machine cut edge)
1125Granite stone of any colour and shade
1126Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with:
1127Udaipur green marble
1128Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
1129Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
1130Size of Tile 600x600 mm
1131Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
1132Size of Tile 600x600 mm
113312 mm cement plaster of mix:
11341:6 (1 cement :6 Coarse sand)
113520 mm cement plaster of mix:
11361:6 (1 cement :6 Coarse sand)
11376 mm cement plaster of mix:
1138(1 cement: 3 fine sand)
1139Applying priming coat
1140With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood)
1141Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant.
1142Painting with synthetic enamel paint of approval brand and manufacture to give an even shade
1143Two or more coats on new work
1144Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1145Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
1146With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
1147Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.
1148Two Coats
1149Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
1150Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately)
1151For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
1152Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
1153Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item)
1154With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
1155Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
1156GIRLS HOSTEL FIRST FLOOR CIVIL
1157Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately)
1158All works above Plinth level upto floor V level
1159Centering and shuttering including strutting, propping etc. and removal of form for
1160Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers
1161Centering and shuttering including strutting, propping etc. and removal of form for
1162Columns, Pillars, Piers, Abutments, Posts & Struts
1163Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
1164Hot Rolled deformed bars
1165Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
1166With F. P. S. (non-modular) bricks
1167Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
1168Cement mortar 1:4 (1 cement : 4 coarse sand)
1169Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
1170Second class teak wood
1171Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
117212 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked
1173Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge.
1174Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
117535 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
1176Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
1177100x75x4 mm
1178Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
1179250x16 mm
1180Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
1181200 * 10mm
1182Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
1183125 mm
1184Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
1185Twin rubber stopper
1186Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
1187Fixed to opening/ wooden frames with rawl plugs screws etc.
1188Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades.
11898mm thick (mirror polished and machine cut edge)
1190Granite stone of any colour and shade
1191Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with:
1192Udaipur green marble
1193Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
1194Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete
1195Size of Tile 600x600 mm
1196Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
1197Size of Tile 600x600 mm
1198Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses.
11990.50 mm thick
1200Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
1201Hot finished welded type tubes
120212 mm cement plaster of mix:
12031:6 (1 cement :6 Coarse sand)
120420 mm cement plaster of mix:
12051:6 (1 cement :6 Coarse sand)
1206Applying priming coat
1207With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood)
1208Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant.
1209Painting with synthetic enamel paint of approval brand and manufacture to give an even shade
1210Two or more coats on new work
1211Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1212Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.
1213With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
1214Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.
1215Two Coats
1216Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately)
1217For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately)
1218Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15):
1219Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item)
1220With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
1221Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
1222GIRLS HOSTLE SEPTIC TANK
1223Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
1224All kind of Soil
1225Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge
1226Ordinary Rock
1227Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level
12281:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size)
1229Reinforced cement concrete work in walls (any thickness), Including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement.
12301:1.5:3 (1 Cement: 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size)
1231Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
1232Hot Rolled deformed bars
1233Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
1234With F. P. S. (non-modular) bricks
123512 mm cement plaster finished with floating coat of neat cement of mix
12361:4 (1 cement :4 Fine sand)
1237Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm)
1238Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
1239Inside dimensions 600x850 mm and 45 cm deep for single pipe line.
1240With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5
1241GIRLS HOSTEL GROUND FLOOR PLUMBING
1242Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:
1243White Vitreous China Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
1244Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked black solid plastic seat and lid
1245W.C. pan with ISI marked black solid plastic seat and lid
1246Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
1247White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
1248Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.
1249Rectangular shape 453x357mm dia.
1250Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge
1251Concealed work, including cutting chases and making good the walls etc.
125220 mm nominal outer dia Pipes
1253Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge
1254External work
125540 mm nominal outer dia Pipes
125650 mm nominal outer dia Pipes
1257Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
1258Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
1259Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.
1260With common burnt clay F.P.S( non-modular ) bricks of class designation 7.5
1261Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore
1262Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
1263100x100 mm size P type
1264With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5
1265GIRLS HOSTEL FIRST FLOOR PLUMBING
1266Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:
1267White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
1268Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked black solid plastic seat and lid
1269W.C. pan with ISI marked black solid plastic seat and lid
1270Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.
1271Rectangular shape 453x357mm dia.
1272Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge
1273Concealed work, including cutting chases and making good the walls etc.
127420 mm nominal outer dia Pipes
1275Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge
1276External work
127740 mm nominal outer dia Pipes
127850 mm nominal outer dia Pipes
1279Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
1280Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
1281Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore
1282Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
1283GIRLS HOSTEL GROUND FLOOR INTERNAL ELECTRIFICATION
1284Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e. providing and fixing anchor made 5A flush type switches and all other accessories
1285a. Light point Short
1286b. Light point Medium
1287c. Light point Long
1288d. Call bell Point Long
1289e. Fan point medium
1290f. Exhaust fan point medium
1291Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc.
1292a. Medium point
1293b. Long point
1294Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc.
1295a. Medium point
1296b. Long point
1297Wiring for circuit/sub-main with PVC insulated copper cable core in surface casing capping etc.
1298a. With 1.5 mm2 copper cable s/core
1299b. With 2.5 mm2 copper cable s/core
1300c. with 4 mm2 copper cable s/core
1301d. With 6mm2 copper cable s/core
1302e. With 10mm2 copper cable s/core
1303f. With 1mm copper cable s/core for earth continuity
1304Fixing & Providing, Drilling holes and connection etc
1305a. MCB 10A
1306b. MCB 16A
1307c. MCB 20A
1308d. Isolator 40 Amp 2 pole
1309e. Isolator 63 Amp 2 pole
1310f. MCB Box 10 ways
1311g. MCB Box 12 ways
1312h. Main Switch 100A
1313i. Bus-Bar 100A 4 strips
1314j. TPN 100A
1315k. Change over Switch 100A
1316l. Angle holder
1317m. Bracket holder
1318n. LED Double tube light fitting 2x40wx4 with all accessories
1319o. Exhaust fan with all accessories
1320p. LED bulb 9w
1321q. Call Bell Ding Dong
1322r. Bulk head fitting with all accessories
1323Providing & fixing, drilling holes and connection etc.
1324a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal, salt etc.as required. The depth of the pit shall be atleast 3m or as per moisture availability.
1325b. Copper wire 4sq.mm
1326c. Lightning arrester
1327d. Panel Board
1328e.100 Sq.mm Al. LT. Power Cable
1329Supplying and installing Energy Meter
1330Armed cablefor Main 4 core X 10 Sqmm for Building
1331Armed cablefor Main 4 core X 4 Sqmm for Building
1332Armed cablefor Main 4 core X 35 Sqmm for Building
1333Supplying and installing Water Purifier
1334GIRLS HOSTEL FIRST FLOOR INTERNAL ELECTRIFICATION
1335Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e. providing and fixing anchor made 5A flush type switches and all other accessories
1336a. Light point Short
1337b. Light point Medium
1338c. Light point Long
1339d. Call bell Point Long
1340e. Fan point medium
1341f. Exhaust fan point medium
1342Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc.
1343a. Medium point
1344b. Long point
1345Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc.
1346a. Medium point
1347b. Long point
1348Wiring for circuit/sub-main with PVC insulated copper cable core in surface casing capping etc.
1349a. With 1.5 mm2 copper cable s/core
1350b. With 2.5 mm2 copper cable s/core
1351c. with 4 mm2 copper cable s/core
1352d. With 6mm2 copper cable s/core
1353e. With 10mm2 copper cable s/core
1354f. With 1mm copper cable s/core for earth continuity
1355Fixing & Providing, Drilling holes and connection etc
1356a. MCB 10A
1357b. MCB 16A
1358c. MCB 20A
1359d. Isolator 40 Amp 2 pole
1360e. Isolator 63 Amp 2 pole
1361f. MCB Box 10 ways
1362g. MCB Box 12 ways
1363h. Main Switch 100A
1364i. Angle holder
1365j. Bracket holder
1366k. LED Double tube light fitting 2x40wx4 with all accessories
1367l. Exhaust fan with all accessories
1368m. LED bulb 9w
1369n. Call Bell Ding Dong
1370o. Bulk head fitting with all accessories
1371Providing & fixing, drilling holes and connection etc.

AI Tender Summary

OUR REF NO 45322714
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 18.08 Crore
LAST DATE 25-10-2024
Authority
Authority Name Directorate Of School Education
Work Description Infrastructural Development Of Lighthouse School Complex (Lsc) - Government Higher Secondary School (Ghss) Tuensang Under Tuensang District
Basic Detail
Tender No IN-DSE-450250-CW-RFB
Bidding Type Tender
Location
City tuensang
State Nagaland
Key Dates
Publish Date 15 Oct 2024
Submission Date 25 Oct 2024
Open Date 25 Oct 2024
Finance
Tender Value 18.08 Crore
Tender Fee 15000
EMD 18.08 Lakhs
Exemption Not Available
Document List
83334676-9f3a-48d0-a7cc-0f05ae1c27d6.html
BOQ_813.xls
GHSS_Tuensang_Sec_II.pdf
RFB_LSC_Tuensang.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 25, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 25, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 25, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

83334676-9f3a-48d0-a7cc-0f05ae1c27d6.html

xls

BOQ_813.xls

pdf

GHSS_Tuensang_Sec_II.pdf

pdf

RFB_LSC_Tuensang.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender