}

Tender For Provision Of Deficient Omqs At Af Stn Sulur (Phase-I), sulur-Tamil Nadu

Military Engineer Services has published Tender For Provision Of Deficient Omqs At Af Stn Sulur (Phase-I). Submission Date for this Tender is 17-10-2024. Pump House Construction Tenders in sulur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

45316883
Corrigendum : Tender For Provision Of Deficient Omqs At Af Stn Sulur (Phase-I)
Open Tender
NCB
Tamil Nadu
Sulur
17-10-2024

Tender Details

Tender For Provision Of Deficient Omqs At Af Stn Sulur (Phase-I); 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part IA to XIII are prepriced by MES under Ser No. 1 to 8. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “Buildings or Works” as listed in Schedule ‘A’Part–IA 4 Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’Part–II 5 Lumpsum price worked out by the contractor for “Internal Electric Supply as listed in Schedule ‘A’Part–III 6 Lumpsum price worked out by the contractor for “Road / Culvert / Footpath as listed in Schedule ‘A’ Part IV . 7 Lumpsum price worked out by the contractor for Sewage Disposal as listed in Schedule ‘A’ Part V . 8 Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part – VI. 9 Lumpsum price worked out by the contractor for “Chain link fencing with gate” as listed in Schedule ‘A’ Part – VII. 10 Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part – VIII. 11 Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part – IX. 12 Lumpsum price worked out by the contractor for “Lift” as listed in Schedule ‘A’ Part – X. 13 Lumpsum price worked out by the contractor for “Solar Water Heater” as listed in Schedule ‘A’ Part – XI. 14 Lumpsum price worked out by the contractor for “Lightning Protection” as listed in Schedule ‘A’ Part – XII. 15 Lumpsum price worked out by the contractor for “Fire Fighting” as listed in Schedule ‘A’ Part – XIII. 16 Sch A Part - I : BUILDINGS OR WORKSDesign and Construction of Married Accommodation includinggarages in 5 storey (Ground+4 storey)framed construction with permanent specifications in RCC of grade as per structural drawings with AAC block masonry walls, ATT, PU based WPT, 25000 litre capacity RCC water tank on terrace, earthquake resistance as per latest IS and Green building norms with GRIHA star rating etc complete all as specified and as shown on drawings. Note: The quoted rate against is deemed to include for the provisions contained in Sch A Notes. Refer Sch A Notes complete before quoting these items. 17 Design and Construction of Pump house building single storey framed construction with permanent specifications in RCC of grade as per structural drawings with AAC block masonry walls, ATT, PU based WPT, earthquake resistance as per latest IS and Green building norms with GRIHA star rating etc complete all as specified and as shown on drawings. Note: The quoted rate against is deemed to include for the provisions contained in Sch A Notes. Refer Sch A Notes complete before quoting these items. 18 Sch A Part - XIV : Fittings / Fixtures & Misc items. INTERNAL WATER SUPPLYSupply and fix 15mm bore kitchen sink tap brass chromium plated dual flow pattern with silicon black flexible hose swivel type complete all as specified and as directed. 19 Supply and fix 15mm bore washing machine tap brass chromium plated complete all as specified and as directed. 20 INTERNAL ELECTRIC SUPPLY Supply and fix 9 watt LED Bulb complete in all respect all as specified and as directed by engineer in charge 21 Supply and fix wall mounting fan 400mm sweep, 70CMM, power consumption not more 50W etc complete in all respect all as specified and as directed by engineer in charge. 22 Supply and fix Modular TV Socket, one module etc complete in all respect all as specified and as directed by engineer in charge. 23 Supply and fix Modular Telephone socket, RJ-11, one module etc complete in all respect all as specified and as directed by engineer in charge. 24 M&L for Telephone Wiring with unarmoured Solid annealed bare copper industrial cablein concealed of size 0.5 mm, 3 pair with PVC Conduit 25 mm diaetc complete in all respect all as specified and as directed by engineer in charge . 25 M&L for TV Wiring with unarmoured coaxial cable, RG-11in concealedwith PVC Conduit 25 mm diaetc complete in all respect all as specified and as directed by engineer in charge. 26 M&L for Mild steel Box for Telephone wiring including blocks, Suitable for 35 Pair etc complete in all respect all as specified and as directed by engineer in charge. 27 Supply and fix Electric Chimney of size 60 CM, Air suction capacity not less than 1080 m3/Hr, Filterless and dry heatautomatic clean technology, Air pipe of size 150 mm dia etc complete in all respect etc complete in all respect all as specified and as directed by engineer in charge. 28 Material and labour for Aluminium ducting pipe of 150 mm dia all as specified and directed by engineer in charge including making necessary size hole in wall finishing to match with the surroundings etc complete in all respect all as specified and as directed by engineer in charge. 29 Supply, Install, testing & commissioning factory made wall mounted indoor type dust and vermin proof Feeder pillar LT panel board cubical double door hinged type compartmentalized of suitable size 415 volts, AC 50 Hz fabricated of CRCA sheet 3 mm thick machine pressed and angle iron frame 50mm x 50mmx 6mm grouted in PCC 1:2:4 type B1 (20mm grade stone aggregated) powder coated inside and outside complete including copper bus bar of 400A capacity mounted on porcelain insulators and enclosed in chamber made out of 2mm thick CRCA sheet machine pressed and connection from incoming cables and outgoing electric cable/sub main wiring with suitable size thimbles / lugs cable gland with open able shutters on both side and comprising of the following :-(i) incomingMCCB 250 Amp, 36 KA, 4 Pole 415 Volt - 01 Nos(ii) Out going TP MCB 40 Amp 4 pole 415 volt 16 KA - 19 Nos (18 Qtrs + 01 Nos spare) (iii) Copper bus bar for 3 Ph & Neutral 400 Amp- 01 Set(iv) Volt meter 0-500V (v) Ammeter with CTs 50 A rangeand selector switch(vi) Phase indicator neon lamps for 3 Ph -01 Set(vii) SP MCB 6-32 A - 03 Nos (For common area Lighting + 01 Spare ) 30 EXTERNAL WATER SUPPLYCutting cast iron of 150 mm dia bore and reducing to required length before laying pipes in position for insertion of new tees, branches of different sizes as per site requirement complete all as specified and as directed. 31 Supply and lay pipe ductile Iron , S/S including specials, Class “K-7”, 100 mm (4”) dia complete all as specified and as directed. 32 Supply and fix Valve, non return valve 50 mm dia complete all as specified and as directed. 33 Supply and fix Foot Valve conforming to IS 4038, 63 mm dia complete all as specified and as directed. 34 Construction of valve chamber with inner clear dimension 600mm x 600mm x 900mm suitable for 80mm sluice Valves with PCC (1:4:8) 150mm thick type D2 for foundation, Brick masonary 230mm wall in CM (1:4), PCC (1:2:4) 75mm type B1 for coping, rendering in CM (1:4) 15mm thick including provision of 3mm thick MS sheet cover and 25mm x 25mm x 3mm angle frame embedded in coping with two coats of synthetic enamel paint over a coat of redoxide primer with locking arrangements including necessary earth work complete all as specified and directed by Engr-in-charge 35 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 4 sqmm, 3 core, 1100 Volts grade complete all as specified and as directed. 36 S&F LT panel outdoortype made out of MS sheet 2 mm thick with locking arrangement and painting with following accessories suitable for incoming/outgoing arrangements:-(a)MCCB 100 AMP 25KA4 pole - 01 No(b)DOL startersuitable for 5 HP, 415 V AC- 02 Nos(c) MCB TPN 40 A - 03 No(d)MCB SPN 6-32 AMP, 10 KA- 02 Nos(e)DOL startersuitable for 10 HP, 415 V AC - 01 Nos(e)Aluminium bus bar200 Amp TPN- 01 Set(f)LCD multi function meter - 01 No(g) Indicating lamp set- 01 Set of three(h)CT of suitableratio100/5 A- Set of 3 Nos 37 M&L for DI fitting bend (any type, radius and angle) tapersany type (straight, bend, increasing, decreasing or double socket), Tee piece, connection pieces, collars, caps and plug etc complete all as specified and directed. 38 EXTERNAL ELECTRIC SUPPLYRiddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and directed. Note :- In case sufficient sand not obtained from excavation, the quoted rate is deemed to be inclusive for the required additional qty obtain from out side MD land as directed by the Engineer-in-Charge. 39 MM & L for Protection to cable with one layer of Fly ash bricks of size 23 x 10 x 10 cm laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable. 40 Supply and fixing 11KV, 3 phase 20KA/3sec, 50Hz totally gas insulated OUTDOOR compact ring main unit (Type:CCV+) consisting of 2 nos manual operated, fixed type (non draw out type) 630 A load break switches as incomers and 1 No manual operated fixed type (non draw out type) 630 A vaccum circuit breaker as out going complete in a 2.5mm/ more robotically welded stainless steel tank of IP 67/ more class of protection with 350 MVA rupturing capacity, overload & earth fault protection by350 MVA rupturing capacity, overload & earth fault protection by self tank powered relays (ASHIDA make ADR 1415/ABB make REJ 603/ or its equivalent. The panel should be with ring core as per the transformer rating 2.5 VA class 5P10) all as specified and as directed. 41 Shifting, installation & testing of copper wound transformerstep down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 of capacity upto 200 KVA from existing site to prop site (appx 3 KM away) complete all as specified and directed. 42 Material and labour for providing PCC (1:2:4) using 20mm graded aggregate platform including masonary work for transformer, size of 2m x 2m x 2m including fencing complete all as specified and as directed. 43 Supply Install, and commissioning LT feeder pillar(CPRI approved) Outdoor, type made out of 3.15 mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounting plate, frame and canopy, confirms to IEC61439-2 with following accessories suitable for incoming/outgoing arrangements:- (a)MCCB with extended rotary handle and spreader link 300 A 35kA4 pole - 01 No(b)MCCB with rotary handle and spreader link 160 AMP 25kA4 pole - 02 No(c)MCCB with rotary handle and spreader link 160 AMP 25kA4 pole - 01 No (d) MCCB with rotary handle and spreader link 40 AMP 25kA4 pole- 01 No (e) Digital panel meter for volt Amp/Volt/KWH&PF- 01 No(e) LED indicating lamp set- 01 Set of three (f)Timer Switch 20 Amps 44 M & L for GI bracket suitable for street light fittings bend to required shape made up of dia GI tubing 40mm dia medium grade of length 1.50 Mtr including clamps nuts bolts washers complete all as specified and as directed. 45 Supply and fix Synchronising electronic timer unit operated on AC 230 Volts, 24 hrs clock time for controlling street lights/ flood lights etc all as directed. Cat Part No : 4126 41 of Legrand or equivalent in L&T, ABB. 46 Supply and fix Powercontactors 63 Amps, 4 pole,415V etc all as directed . Make : Cat No 4125 57 of Legrand or equivalent of L&T/ Siemens 47 M & L for 02 Nos single core copper conductor PVC unarmoured cable of size 2.5 sqmm and 01 No. copper conductor cable of size 1.5 sqmm for earth 1100 Volts grade PVC insulated and PVC sheathed cable through wall/ pole etc including PVC conduit of 20 mm dia appx length 08 mtrs. 48 Supply and fix junction box size not less than 280x 170x 130mm made of UPVC with aluminium bus bar of 50Ams for phase and neutral on porclein based installation fixed on pole with help of MS nut bolts MS clamps 2 Nos not less than of size 40mm x 4mm fuse with one No MCB SP 6 Amp capacity mounted on rail inside box work also includes making suitable hole in pole to take out connection to fitting if required at site complete all as specified and as directed. 49 M & L for Removal of laid LT /HT cable complete including excavation and removal of bricks and making good the disturbed surfacecomplete all as specified 50 STAND BY POWER SUPPLYSupply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms - IV and foundation etc of capacity upto 40 KVA complete all as specified and as directed. 51 Supply, installation, commissioning and testingof Stainless steel Retro-fit Emission control equipment able to capture specified particulate matter (PM 2.5) emitted from 40 KVA stand by DG with capturing efficiency of minimum 90% and hold 5.5 kibipascal backpressure excerted by DG sets, with min operating Temperature (-) 15 Deg Celsius, Max operating Temperature 750 Deg Celsius, Operating Humidity up to 90% (Non - Condensing) corrosion resistive construction complete all as specified and directed. 52 AVIATION OBSTRUCTION LIGHTSupply and fix aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure complete all as specified and as directed. (Make Bajaj Cat No. BGAV 302 LED or equivalent in approved make) 53 Supply and fix DP MCB 6 A with enclosure complete all as specified and as directed. 54 Supply and fix time switches 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed. 55 LIFTSupply and fix 4 Pole MCCB63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and as directed. 56 Design supply, install, testing & commissioning of 884 KG 13 Passenger lift, speed 1.5 meter/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply , conforming to IS-14665 and as amended, suitable to serve G+04 upper floors with AC variable voltage & variable frequency drive (VVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3Dinfra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near ground floor landing door). Car flooring: 3 mm thick aluminum chequered plate flooring, Handrail : Round handrail in stainless steel finish provided on one side Car design : All car walls in 1.2mm thick stainless steel hairline finish, alarm button, car fan, door open and door close buttons in car operating panel, emergency light, infrared screen for car door, intercom, motor overheat protection, fire man switch, pit ladder other standard fittings and fixtures. Phase failure and phase reversal protection etc all as conforming to IS 14665 (part-1) 2000 complete in all respect all as specified and as directed by Engr-in-charge. Make of lift : OTIS / MITUSBISHI / HITACHI LIFTS / THYSSEN KRUPP 57 Note: The rate quoted shall deemed to include for provision of a simple toggle or two- button switch in glass fronted box adjacent to the lift at entrance level and provision of Ceiling Hatch for use in case of emergency so that the lift could be utilized as fire lift in case of fire as per NBC Code and CFEES recommendations complete in all respect all as specified and as directed by Engr-in-charge.General Notes for SI No 54 :“The contractor shall provide comprehensive AMC of the lift through OEM during Two years defect liability period including cost of all consumables, spares and services of skilled technician, testing by Govt approved lift inspector. Cost of these items is deemed to be included in the quoted rate and nothing extra shall be payable on any account what so ever etc)” 58 SOLAR WATER HEATERMaterial and labour for mild steel compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc built up from two or more beam or channel sections or angles with plates including all lattice bars, stiffeners, gusset plates etc conforming to Fe-290 (Gde E-165) complete all as specified and as directed. 59 LIGHTNING PROTECTIONSupply and fix epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc complete all as specified and as directed. 60 FIRE FIGHTINGS&F Clean Agent based stand alone automated Fire Suppression system HCFC123-10 KG complete all as specified and as directed. Make- Ceasefire/Model No.CF000771 or equivalent in approved make. 61 Supply, laying, testing and commissioning Terrace Pumping sets, centrifugal, electric driven, supply and Install complete capacity of 900 LPM and 3.5 KG/CM2inclusive of starter and PCC foundation complete all as specified and as directed. 62 Supply and install testing and commissioning of yard hydrant consisting of the following(a) 63 mm dia instantaneous pattern oblique hydrant with chain cap(b) 63 mm dia size controlled peculation hose of 2 Nos 15 mtr with gun metal female instaneous coupling as necessary(c ) Sheet steel fabricated hose cabinet of suitable size power coat painted to house the above accessories.(d) one st of branch pipe made of gun metal 63 Supply and lay PVC insulated PVC sheathed wire armoured with multi stranded copper conductor of size 4 Sqmm 4 core 1100 volts grade complete all as specified and as directed. 64 Supply and fix Dry Chemical Powder (ABC) 4 KG fire extinguisher complete all as specified and as directed 65 Supply and fix Light weight squeeze grip typeCO2 Type fire Extinguisher (IS: 15683) - 3 Kg capacity complete all as specified and as directed. 66 Supply and fix Fire Extinguisher water (Stored pressure type) 3 KG complete all as specified and as directed. 67 Supply and fixDry chemical powder extinguisher 9 KG complete all as specified and as directed. 68 Supply and fix Light weight squeeze grip typeCO2 Type Extinguisher (IS: 15683) - 4.5 Kg capacity complete all as specified and as directed. 69 Supply and fix Mechanical foam type Fire Extinguisher (IS: 15683) - 9 Ltrs capacity complete all as specified and as directed. 70 Supply and fix Fire Buckets-02 Nos (IS: 2546) including fire point made of PCC bed, MS pipe of 40mm dia, CGI sheet etc complete as specified and as directed 71 SMART PREPAID METER Design, installation, testing, commissioning, integrate and maintain the Advanced metering infrastructure (AMI) Comprising of following:-(a) Supply, installation, testing, commissioning of smart meter AC single phase, two wire, 240 volts, 50Hz, 10 to 60 amps of different makes (not more than 33% of a particular make to ensure interchangeability at a later date as per BIS 16444 with communication technology including GPRS / RF / Hybrid (GPRS+RF) any other advanced technology as per CEA/TRAI regulations).(b) Supply / planning / setup/ tuning of RF communication infrastructure including Network Management (NMS) & Head End system (HES) for the project area. AMI software and associated equipment should be capable of handling atleast 10000 number of meters of different makes as per BIS 16444 with 25% expansion without any additional infrastructure and cost implication to MES.(c) Supply and setup of Meter Data Management (MDM) System.(d) Integrationof different devices of different makes/equipment/software covered in scope of this project with each other as per functional requirement, including water charges, furniture and license fee. 72 (e) Integration/ interface of the AMI system with application system like metering/billing/collection, interface has to be provided in the proposed solution to upload and process meter data from these systems.(f) Server for housing and management of supplied software application with Standby server (OR) hosting the system to government community cloud in place of server for hosting and management of supplied software application with standby server.(g) Planning, deployment & tuning of communication system including cellular network (if required) to meet the performance requirements.(h) Business intelligence, Analytics and Reporting.(j) Taking down & Return of dismantled materials to MES Store.(k) Training and knowledge transfer.(l) All expenditure including periodic charges of telecom operator from installation till completion.(m) Comprehensive operation and maintenance of AMI system including project implementation & management, all expenditure including periodic charges of telecom operator, smart meter billing and maintenance, for a period of 10 years post completion of work.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 07-10-2024 Amendment No 01 Other 10-10-2024
2 10-10-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-10-2024

Key Value

Document Fees
INR 3000 /-
EMD
INR 1077500.0 /-
Tender Value
INR 15.05 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail