}

Tender For Strengthening Of Distribution Lines, Repairing & Increasing Capacity Of Transformer And Its Associated Work In The Area Of Electricity Distribution Division, Ii Under Business Plan 2024-25.” Sl. No. Item Description 1 Safe Loading Carriag, hardoi-Uttar Pradesh

Madhyanchal Vidut Vitran Nigam Limited has published Tender For Strengthening Of Distribution Lines, Repairing & Increasing Capacity Of Transformer And Its Associated Work In The Area Of Electricity Distribution Division, Ii Under Business Plan 2024-25.” Sl. No. Item Description 1 Safe Loading Carriag. Submission Date for this Tender is 25-09-2024. Wall Construction Tenders in hardoi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

45311958
Tender For Strengthening Of Distribution Lines, Repairing & Increasing Capacity Of Transformer And Its Associated Work In The Area Of Electricity Distribution Division, Ii Under Business Plan 2024-25.” Sl. No. Item Description 1 Safe Loading Carriag
Tender
Indian
Uttar Pradesh
Hardoi
25-09-2024

Tender Details

tender for Strengthening of Distribution Lines, repairing & increasing capacity of Transformer and its associated work in the area of Electricity Distribution Division, II under Business Plan 2024-25.” Sl. No. Item Description 1 Safe loading Carriage & unloading of following material from store centre to pit site/JE dump store. 2 Top Channel with clamp(125x65x2240) mm 3 Dropper Channel with Clamp(100x50x2028)mm 4 T-off Channel with Clamp 5 Sub Station Base Angle(75x75x6x2028)mm 6 11 KV V Type Cross Arm 7 33 KV V Type Cross Arm 8 LT Shackle Insulator 9 25 KVA T/F 10 63 KVA T/F 11 100 KVA T/F 12 250 KVA T/F 13 400 KVA T/F 14 PCC Pole 8.5 Mtr. Long 15 STP Pole 09 Mtr. Long 16 STP Pole 11 Mtr. Long 17 STP Pole 13 Mtr. Long 18 LT XLPE Cable Alluminum 1x240 mm2 19 LT XLPE Cable Alluminum 3.5x150 mm2 20 LT XLPE Cable Alluminum 1x400 mm2 21 ABC Cable(3x50+1x70+1x16) mm2 22 ABC Cable(3x95+1x70+1x16) mm2 23 ABC Cable(3x120+1x95+1x16) mm2 24 G.I. Wire 6 SWG 25 G.I. Wire 8 SWG 26 G.I. Wire 10 SWG 27 11 KV Fuse Set 28 Stay Set Complete 29 Earthing Complete 30 ACSR Weasel Conductor 31 ACSR Rabbit Conductor 32 11 KV DISC Insulator With Fitting 33 11 KV Pin Insulator with G.I. Pin 34 11 KV C.J. Kit 3x185 mm2 I/D 35 11 KV C.J. Kit 3x185 mm2 O/D 36 11 KV C.J. Kit 3x120 mm2 O/D 37 Distribution Box 3-Phase 38 33 KV CJ Kit 3x300 mm2 O/D 39 33 KV CJ Kit 3x300 mm2 I/D 40 Polymeric 33 KV Pin Insulator 41 Polymeric 33 KV Disc Insulator 42 33 KV Stay Set 43 ACSR Dog Conductor 44 LT Fuse Set Complete 45 11 KV XLPE Cable 3x185 46 11 KV XLPE Cable 3x120 47 VCB Panel Incoming 600/300/5 48 VCB Panel Incoming 400/200/5 49 Battery Charger Set 24 Volt 50 Battery Set 24 Volt 51 Work 52 Erection of PCC Pole 8.5 meter long single pole with grouting & with all accessories. 53 Erection of PCC Pole 8.5 meter long Double pole with grouting & with all accessories. 54 Replacement of damaged PCC 8.5 m long on site for 11 kv or lt including grouting of new pole, uprooting of damaged pole & with fixing all necessary accessories. 55 Erection of STP Pole 09 meter long single pole with grouting & with all accessories. 56 Erection of STP Pole 11 meter long single pole with grouting & with all accessories. 57 Erection of STP Pole 13 meter long single pole with grouting & with all accessories. 58 Stringing & Sagging of three phase 11 kv XLPE Aluminum cable 1x240 mm2 as per resspo norm(nut& botls have to arrange by contractor only Cable provided by the deptt.) 59 Stringing & Sagging of three phase 11 kv XLPE Aluminum cable 3.5x150 mm2 as per resspo norm(nut& botls have to arrange by contractor only Cable provided by the deptt.) 60 Stringing & Sagging of three phase 11 kv XLPE Aluminum cable 1x400 mm2 as per resspo norm(nut& botls have to arrange by contractor only Cable provided by the deptt.) 61 ABC Cable (3x50+1x35+1x16)sq mm stringing sagging binding and jumpering of ABC with all accessories, except to cable, eye hook distribution box other required materials have to arranged by contractor only 62 ABC Cable (3x95+1x70+1x16)sq mm stringing sagging binding and jumpering of ABC with all accessories 63 ABC Cable (3x120+1x95+1x16)sq mm stringing sagging binding and jumpering of ABC with all accessories 64 Fixing of11 KV C.J. Kit 3x185 mm2 I/D 65 Fixing of11 KV C.J. Kit 3x185 mm2 O/D 66 Fixing of11 KV C.J. Kit 3x120 mm2 O/D 67 Fixing of Distribution Box 3-Phase 68 Fixing of 33 KV CJ Kit 3x300 mm2 O/D 69 Fixing of 33 KV CJ Kit 3x300 mm2 I/D 70 Installation of 33 KV Stay Set 71 Concreting and fixing of 33 KV Stay Set 72 Stringing & Sagging of three phase ACSR Dog Conductor as per resspo norm(nut n botls & other required materialshave to arrange by contractor only conductor arrange by the deptt.) 73 Concreting of 11 kv Stay Set Complete 74 Concreting of33 KV Stay Set 75 Installation and Fixing of 11kv Fuse Set (all Material arranged by the contractor except fuse set ) 76 Stringing & Sagging of 11 KV XLPE Cable 3x18 as per resspo norm(nut n botls & other required materialshave to arrange by contractor only conductor arrange by the deptt.) 77 Stringing & Sagging of 11 KV XLPE Cable 3x120 as per resspo norm(nut n bolts & other required materialshave to arrange by contractor only conductor arrange by the deptt.) 78 Installation,Fixing of 11 kv VCB Panel Incoming 600/300/5( rating may vary as per availability of material)(all Materail like control Cable , HT Tape,Lugs wiring and other asrequired arranged by the contractor except VCB Pannel. 79 Installation,Fixing of 11 kvVCB Panel Incoming 400/200/5 ( rating may vary as per availability of material)(all Materail like control Cable , HT Tape,Lugs wiring and other asrequired arranged by the contractor except VCB Pannel. 80 Installation of Battery Charger Set 24 Volt 81 Installation of Battery Set 24 Volt 82 Construction of T/F plinth of size 2x2x1.5 m on a padding 0.25M deep in ground 1:5:10 cement sand and brick ballast on the top of padding brick work Ist class brick of 0.95 mtr height & 0.35 mtr wall will be constructed. Rest wall should be 0.23 mtr thick. Brick work in ratio 1:4 cement & cores Sand in the hollow portion the sand should be filled from the ground level up to 15 centimeters below from the top of wall, Cement, sand & brick Ballasts should be filled up to 15 centimeter. Two no. of channel 100x50 in length 1500mm will be grouded.0.35 CM.RCC will be done with cores sand, cement and stone ballast in the ratio of 1:2:4.The T/Fs plinth should be plastered on all sides 12mm thick in ratio 1:6 by cement and cores sand.(All the material to be arranged by the contractor). 83 Earthing by way of Boring and lowering the B class GI pipe (Gindal ) of 50mm dia from ground upto water level not less than 20mtr as per standard practice 84 Construction of retaining wall, fabrication & erection of Wire mesh fencing of size 3 + 3 & 2.0M height around Transformer and Distribution Pillar Box with retaining wall & 1 no. gate with locking arrangement made of MS Angle iron of size 50x50x6 mm jointed with nuts and bolts. The panel must be supported with MS Flat of size 50x6 mm.Wire mesh of size 10 SWG rectangle type, as per norms of RESSPO.(All the material will be arranged by the contractor at his own cost). 85 Mobile Trolly Repairing completewith accessories 86 Supply of Mobile Trolly New Complete with all necessaryAccessory as per RESSPO norms. 87 Hoisting of 11 kv XLPE (3x120/3x 185 )sq.mm with the provision of G.I. Pipe of size 150 mm dia. 88 After removal ofconnected Lead safely. Safe Dismounting & Mounting of 25 KVAT/F on the main powerfrom pole by technical equipment like Hydra or Crane & energised them (Trolley, Hydra Or Crane arranged by the contractor at his own cost) 89 After removal ofconnected Lead safely. Safe Dismounting & Mounting of 63 KVAT/F on the main powerfrom pole by technical equipment like Hydra or Crane & energised them (Trolley, Hydra Or Crane arranged by the contractor at his own cost) 90 Placement of 11/0.4 KV T/Fs from dump place to newly constructed T/Fs plinth & installation, commissioning of 250/400 KVA T/Fs on T/FPlinth and including jumpering with the system ( Alltherequiredmartial for abovejob shall be provided by contractor except T/Fs) as per respo norms. 91 Dismantling of Old and Used Existing Infrastructure & Safe Loading Unloading from Site to JE Store/Center Store Hardoi 92 10 KVA T/F 93 16 KVA T/F 94 25 KVA T/F 95 63 KVA T/F 96 100 KVA T/F

Key Value

Document Fees
INR 5900 /-
EMD
INR 282000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail