| 1 | Geyser Material and labour for maintence of storage type electric water heater geyser capacity 25/35/50 litre comprising of the following activities:-(a) Inspection taking down, opening, dismantling , descaling, replacing unserviceable items brushing and cleaning of storage tank and examining of water tightness of storage tank after cleaning and descaling and refixing in position(b) Check and connect earth continuity of electric items(c) checking and adjustment of pressure release valves(d) Cleaning and maintainance and refixing thermostat and its functioning(e) Checking of dead weight, cleaning and seal and ensuring that vent hole is not fuctioning(f) Visual examination of fuseibie plug ((g) Testing of geyser after repair Note:- The items requires replacement will be measured and paid seapartely under relevant items as supply only |
| 2 | Supply only heating element ofgeyser ISI Marked any type (Triangular/Rond cup , square etc. as per sample) 2 KW Capacityof INCOLOY material (petty item such as nut ,bolt, clamps etc are deemed to be included in unit rate) ; Complete all as specified and directed by Engineer-in-charge. |
| 3 | Supply only heating element ofgeyser ISI Marked any type (Triangular/Rond cup, square etc as per sample.) 1.5 KW Capacityof INCOLOY material (petty item such as nut ,bolt, clamps etc are deemed to be included in unit rate) ; Complete all as specified and directed by Engineer-in-charge. |
| 4 | Supply only thermostat as per sample ISI marked for geyser any capacity ; Complete all as specified and directed by Engineer-in-charge. |
| 5 | Supply only thermal cut out as per sample ISI marked for geyser any capacity ; Complete all as specified and directed by Engineer-in-charge. |
| 6 | Supply only indicator lamp as per sampleto geyser of any size and shape ; Complete all as specified and directed by Engineer-in-charge. |
| 7 | Supply and Fixing in replacement of GI hexa nipple (set of two) of size 15 mm having screwed both ends wit fine thread ; Complete all as specified and directed by Engineer-in-charge. |
| 8 | Supply only inner shell as per sample of suitable size made of stainless steel sheet ofFe 305 22 SWG ISI Marked can bear pressuure upto 0.8 MPa suitable for geyser of any type/Make and 25/35 litres capacity complete with all suitable accessories such as thermal insulation etc ; Complete all as specified and directed by Engineer-in-charge. |
| 9 | Supply only inner shell as per sample of suitable size made of stainless steel sheet ofFe 305 22 SWG ISI Marked can bear pressuure upto 0.8MPa suitable for geyser of any type/Make and 50 litres capacity complete with all suitable accessories such as thermal insulation etc ; Complete all as specified and directed by Engineer-in-charge. |
| 10 | Supply onlyinner base assembly as per samplecomplete with inlet ,outlet, thermostat pipes with drain plug and screw including clamps for holding the elements, nuts, bolt ,washer etc, ISI Marked for geyser of any type/Make and 25/35/50 litres capacity ; Complete all as specified and directed by Engineer-in-charge. |
| 11 | Supply and Fixing in replacement of copper wire, 3 core, flexible type of size 2.5 sqmm etc complete all as specified and directed by the Engineer-in-Charge. |
| 12 | Supply only bottom cover plate (two halves) and Fixing with new bottom cover plate with matching colour of geysers of any type/Make and capacity ; Complete all as specified and directed by Engineer-in-charge. |
| 13 | Taking down existing unserviceable Non return valve and supply and dixing in poisition with new multifunction valve(NRV)ISI marked made of cast copper alloy screwed both ends internallysuitable for iron pipe of size 15mm ; Complete all as specified and directed by Engineer-in-charge. |
| 14 | Supply only safety pressure valvewith vent to geyser as per latest ISI specification ; Complete all as specified and directed by Engineer-in-charge. |
| 15 | Material and labour for PVC connection suitable for hot waterof size 15 mm x 600mm long superior quality for geyser complete with brass adopter for geyser ofany capacity ; Complete all as specified and directed by Engineer-in-charge. |
| 16 | Supply only of neoprene seal (bottom ring)for 25/35/50 ltr capacity geyser of superior quality; Complete all as specified and directed by Engineer-in-charge. |
| 17 | Material and Labour for painting the outer surface of geysers of 25/35/50 itrs as per original shade with two coats of synthetic enamel paint over one coat of primer by spray gun after scrapping the existing paint, denting, filling depression with putty etc and refixing the geyser in position including water/electric connection and testing, ; Complete all as specified and directed by Engineer-in-charge. |
| 18 | Material and Labour for Brazing / welding of innertank at leaking spots up to five leakage of geyser of capacity 25/35/50 ltrs of any type and make of tank after checking up worn out nuts bolts and washerscomplete all as specified and directed by Engineer - in - charge. |
| 19 | Supply and Fixingin replacement of brass chormium plated angle valve, fancy typeof size 15mm dia screwed down for high pressure, ; Complete all as specified and directed by Engineer-in-charge. |
| 20 | Supply and Fixing in replacement of sheet metal enclosure (industrial type DB) complete in 2P+E configuration with plug andsocket complete with one MCB SP B Curve type of capacity 20 Amp 10 KA ; Complete all as specified and directed by Engineer-in-charge. |
| 21 | Material and labour for grouting of nuts & Tee bolts as directedfor Fixing of 50/35/25 Itrs capacity geyser including cement work and colour matching on existing wall ; Complete all as specified and directed by Engineer-in-charge. |
| 22 | Supply and Fixing inreplacement of 3 pin socket suitable for sheet metal enclosure (industrial type DB) 20A complete all as speicified and directed |
| 23 | Supply and Fixing inreplacement of 3 pin plug suitable for sheet metal enclosure (industrial type DB) 20A complete all as speicified and directed |
| 24 | Supply and Fixing in Replacement of 16Amp plug top with indicator; Complete all as specified and directed by Engineer-in-charge. |
| 25 | Supply and Fixing Socket 16Amp multipurpose shutter type fixed on laminated sheet top cover; Complete all as specified and directed by Engineer-in-charge. |
| 26 | Supply and Fixing Switch 16Amp fixed on laminated sheet top cover ; Complete all as specified and directed by Engineer-in-charge. |
| 27 | Supply and Fixingin replacement Brass chromium plated fancy type bib tabs of size 15 mm diabore short body, screwed downfor GIpipeor for brass ferruleand fixed ; Complete all as specified and directed by Engineer-in-charge. |
| 28 | Supply and Fixing in replacement MCB B Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA as specified and25 to 32 Amps ; Complete all as specified and directed by Engineer-in-charge. |
| 29 | Material and Labour for sub main wiring with 1100 volt grade two single core PVC insulated and unsheathed cable with stranded copper conductor 4.0 sqmm drawn into and including electrical grade PVC conduit medium gradenot less than 20 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for Fixing conduit and making good the disturb surfaces of wall as per existing including 2.5 sqmm multi - stranded copper conductor as earth wire in green colour ; Complete all as specified and directed by Engineer-in-charge. |
| 30 | SOLAR WATER HEATING SYSTEM Disconnecting electrical connection of solar heating device carefully dismantling solar panel with water tube (copper assembly/ETC tube) rubber gasket; nut bolt; biding aluminum channel and glass carefully and servicing/Descaling/cleanning with acid & water circulation and wire brush and brazing of cooper tube checking of leakageif any . After servicing reassemble the same and testing of solar water heater.; Complete all as specified and directed by Engineer-in-charge. |
| 31 | Supply and Fixing in replacement of gas kit set for ETC tube ; Complete all as specified and directed by Engineer-in-charge. |
| 32 | Supply and Fixing in replacement of ETC tube holder without cups .; Complete all as specified and directed by Engineer-in-charge. |
| 33 | Supply and Fixing in replacement of solar evacuated tube of solar water heater as per existing suitable for 300/ 500 LPD ,complete with washer etc ; Complete all as specified and directed by Engineer-in-charge. |
| 34 | Supply and Fixing rotational moulded polythelene water storage tanks(Triple layer) capacity 500 litres(cylindrical vertical with closed top), with and including 20mm dia float valve with brass fittings hoisted, fixed in position and making connection including dismantling of existing unserviceable tank ; Complete all as specified and directed by Engineer-in-charge. |
| 35 | Supply and Fixing in replacement of aluminium foil forsolar collector ; Complete all as specified and directed by Engineer-in-charge. |
| 36 | Supply and Fixing in replacement of rubber grommet (for collector). ; Complete all as specified and directed by Engineer-in-charge. |
| 37 | supply and Fixing in replacement of MS dead flange. ; Complete all as specified and directed by Engineer-in-charge. |
| 38 | Supply and Fixing in replacement of heatpipe for collector ; Complete all as specified and directed by Engineer-in-charge.. |
| 39 | Supply and Fixing in replacement of round clamp for hose pipe. ; Complete all as specified and directed by Engineer-in-charge. |
| 40 | Supply and Fixing in replacement of brass flange. ; Complete all as specified and directed by Engineer-in-charge. |
| 41 | Supply and Fixing in replacement of Toughened/ tempered glass for solar collectorhaving 4 mm thickness transmissivity more than 85 %.as per existing size ; Complete all as specified and directed by Engineer-in-charge. |
| 42 | Material and labour for coolant/ Food Grade propylene glycol/ etylene glycol for solar heating system ; Complete all as specified and directed by Engineer-in-charge. |
| 43 | Supply and Fixingin replacement of heating element INCOLOY type for water heating system 3 KWas per sample ISI Marked with rubber gasket of suitable Size.; Complete all as specified and directed by Engineer-in-charge. |
| 44 | Supply and Fixingin replacement of thermostate ISI marked suitable for solar heater; Complete all as specified and directed by Engineer-in-charge.. |
| 45 | Dismantling the complete assembly of solar hot water tank in replacement of supply and Fixing 500 ltrs pre insulated hot water storage tank with stand (inner tankSS 304 ) removing insulated Fixingtures including all inlet outlet connections testing the leakages with compressed air, reshaping the squeezed portion of its original shape,filling of leak points with brazing /organ welding and reclading,connecting the removed water lines,testing of solar hot water tankAll as specified and directed by Engineer-in- Charge |
| 46 | Dismantling the complete assembly of solar hot water tank in replacement of supply and Fixing 300 ltrs pre insulated hot water storage tank with stand (inner tankSS 304 ) removing insulated Fixingtures including all inlet outlet connections testing the leakages with compressed air, reshaping the squeezed portion of its original shape,filling of leak points with brazing /organ welding and reclading,connecting the removed water lines,testing of solar hot water tank All as specified and directed by Engineer-in- Charge |
| 47 | Supply and Fixing GI Pipe size25 MM dia med grade galvanised with all fitting ; Complete all as specified and directed by Engineer-in-charge. |
| 48 | Supply and Fixing GI Pipe size20 MM dia med grade galvanised with all fitting complete; Complete all as specified and directed by Engineer-in-charge. |
| 49 | Supply and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of size 20 mm dia ; Complete all as specified and directed by Engineer-in-charge. |
| 50 | Supply and Fixing CPVC Pipe size25 MM dia suitable for hot water with all fitting ; Complete all as specified and directed by Engineer-in-charge.. |
| 51 | Supply and Fixing gate valve gun metal with iron wheel head, screwed both ends for iron pipe and fixed size 25 mm dia ; Complete all as specified and directed by Engineer-in-charge. |
| 52 | Supply and Fixing gate valve gun metal with iron wheel head, screwed both ends for iron pipe and fixed size 20 mm dia ; Complete all as specified and directed by Engineer-in-charge. |
| 53 | RO SYSTEMDisconnecting electrical connection/water connection of RO System carefully dismantling and change the defecting part and reassembling and testing after changing the defects parts. All as specified and directed by Engineer-in- Charge |
| 54 | Supply and Fixing in replacementRO membrane in welded housing ; Complete all as specified and directed by Engineer-in-charge. |
| 55 | Supply and Fixingin replacement of filter housing; Complete all as specified and directed by Engineer-in-charge. |
| 56 | Supply and Fixing in replacement of SMPS 2.5A 24V DC ADAPTOR with incoming and outgoing wires; Complete all as specified and directed by Engineer-in-charge. |
| 57 | Supply and Fixing in replacement sediment filter ; Complete all as specified and directed by Engineer-in-charge. |
| 58 | Supply and Fixingin replacement activated carbon filter ; Complete all as specified and directed by Engineer-in-charge.. |
| 59 | Supply and Fixing needle control valve assembly ; Complete all as specified and directed by Engineer-in-charge. |
| 60 | Supply and Fixing plastic pipe 1/4 \" blue ; Complete all as specified and directed by Engineer-in-charge. |
| 61 | Supply and Fixing plastic pipe 1/4 \" white ; Complete all as specified and directed by Engineer-in-charge. |
| 62 | Supply and Fixing elbow PL0404 for 1/4\" pipe ; Complete all as specified and directed by Engineer-in-charge. |
| 63 | Supply and Fixing in replacementSolenoid valve 24V DC ; Complete all as specified and directed by Engineer-in-charge. |
| 64 | Supply and Fixingin replacement FRT-800ML ; Complete all as specified and directed by Engineer-in-charge. |
| 65 | Supply and Fixingin replacement LP &HP switch ; Complete all as specified and directed by Engineer-in-charge. |
| 66 | Supply and Fixing in replacement ofDiaphragm Pump 150GPD ; Complete all as specified and directed by Engineer-in-charge. |
| 67 | CENTRAL AC PLANTMaterial and labour for maintenance of central AC plant (chiller unit01x 39 TR) with complete decsaling with the help of pressure motor and decsaling material ; Complete all as specified and directed by Engineer-in-charge. |
| 68 | Material and labour for maintenance of Air handling unit with complete cleaningwith the help of pressure motor and oil and greasing to all bearings; Complete all as specified and directed by Engineer-in-charge.. |
| 69 | Repair / replacement of Air handling unit fine filters suitable for ICUs all asper existing sample; Complete all as specified and directed by Engineer-in-charge. |
| 70 | Repair / replacement of Air handling unit wire mesh filters suitable for ICUs all asper existing sample ; Complete all as specified and directed by Engineer-in-charge. |
| 71 | Supply and Fixing Fan beltNo- A1382 Lp/A53 for AHU motor; Complete all as specified and directed by Engineer-in-charge. |
| 72 | Supply and Fixing Fan beltNo- A1433 Lp/A53 for AHU motor; Complete all as specified and directed by Engineer-in-charge. |
| 73 | Supply and Fixing Fan beltNo- B 1618 Lp/B62 for AHU motor; Complete all as specified and directed by Engineer-in-charge. |
| 74 | Supply and Fixing Cooling tower fan assembly (1200 mm)blade as per sample; Complete all as specified and directed by Engineer-in-charge. |
| 75 | Supply and Fixing digital wall mounted temp and humidity meter ISI marked; Complete all as specified and directed by Engineer-in-charge. |
| 76 | Supply and Fixing Pressure guage of 100 psi kg/ cm sq for condencing and chiller water pipe line; Complete all as specified and directed by Engineer-in-charge. |
| 77 | Supply and Fixing line operated three phase ACmonoblock motor 7.5 HP, 1450 RPM of BRG: DE/NDE 6208 2Z/6208 2Z, IP -55, IE2, ISI mark of cat No- MHCITHS405X5 ( Havells ) for AHU of capacity 8000CFM; Complete all as specified and directed by Engineer-in-charge.( Note :- Old Unsv motor will be deposited to E/M store yard ) |
| 78 | Supply and Fixing line operated three phase ACmonoblock motor 5 HP, 1450 RPM of BRG: DE/NDE 6206 2Z/6206 2Z, IP -55 ,IE2 ,ISI mark of cat No- MHCITHS403X7 ( Havells ) for AHU of capacity 4000 /4500 CFM ; Complete all as specified and directed by Engineer-in-charge.( Note :- Old Unsv motor will be deposited to E/M store yard ) |
| 79 | Material and Labour for charging of refrigerant Gas R-407 C complete all as specified after carrying out leak test and arresting the leakage ; Complete all as specified and directed by Engineer-in-charge. |
| 80 | Supply and Fixing in replacement heating element of capacity4 KW suitable for hot water generator all as per sample ; Complete all as specified and directed by Engineer-in-charge. |
| 81 | Material and Labour for cleaing of cooling tower complete all as directed incl removal of all dust and replament of Nylon Jali as per sample and; Complete all as specified and directed by Engineer-in-charge. |
| 82 | Material and Labour for servicing of Condensor / chiller pump of capacity 5 HP complete incl oiling greasing of bearing , replacement of shaft seal of Pump setcomplete; Complete all as specified and directed by Engineer-in-charge. |
| 83 | Supply and Fixing in replacementbutterfly valve ISI marked 100 mm dia; Complete all as specified and directed by Engineer-in-charge. |
| 84 | Supply and Fixing in replacementbutterfly valve ISI marked 150 mm dia; Complete all as specified and directed by Engineer-in-charge. |
| 85 | Supply and Fixing in replacement chiller sensor all as per make and sample ; Complete all as specified and directed by Engineer-in-charge. |
| 86 | Attending day to day emergency complaints for geysers shock, sparking in geyser wiring , geyser not working etc ; Complete all as specified and as directed by Engineer-in-Charge.Notes for Sl Item No.86(i) Contractor has to take the complaint at MES power house (E/M) from Concern JE E/M Daily Basis (Except Sunday & holiday).(ii) Contrcator has to attend the complaint within 24 Hrs after recived from JE E/M.(iii) Contrctor has to provide the Mobile no so that massges can be send on the same mobile No.(iv) For non collection of complaits from JE E/M Rs.500/- per day will be charged. (v) For Non attendence of complaints in 24 Hrs Rs.200/- per day per complaint will be charged(vi) Contractor has to return the complaint duly signed from the user with time & date. |