Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #45278087

Tender For Repair / Maint Of Day To Day Complaints Of Perimeter Street Lights, Area Lights, High Mast Lights, Solar Lights And Certain E/M Works At Af Stn Sulur

Issued by Statutory Bodies & Commissions/Committees · sulur, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Oct 2024
0 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
sulur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

REPAIR / MAINT OF DAY TO DAY COMPLAINTS OF PERIMETER STREET LIGHTS, AREA LIGHTS, HIGH MAST LIGHTS, SOLAR LIGHTS AND CERTAIN E/M WORKS AT AF STN SULUR

BOQ

Name of Work: REPAIR / MAINT OF DAY TO DAY COMPLAINTS OF PERIMETER STREET LIGHTS, AREA LIGHTS, HIGH MAST LIGHTS, SOLAR LIGHTS AND CERTAIN E/M WORKS AT AF STN SULUR
Sl. No. Item Description
1SCHEDULE A BOQ
2M & L for disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the 25/ 35 sqmm 3.5 core size of LT underground armoured cablescomplete all as specified and directed.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted.
3S & F GI tubing 40/50 mm bore light grade 1.2 mtr long bent to shape as required with clamps for fixing of street light on poles/ walls including nuts, bolts, washers clamps of suitable size including taking down existing onecomplete all as specified and directed.
4S & F Singlepole MCB 6 to 32 Amps, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996including taking down existing one complete all as specified and directed.
5Supply and fixing in repairs LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
6Supply and fixing in repairsTPN, MCB 40 to 63 amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996 completeall as specified and directed
7Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out completeall as specified and directed
8Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as per specified and as directed. .
9Note for item No 8 :- In case sufficient sand not obtained from excavation, the rate is deemed to be inclusive for additional qty of sand requiredto be obtain from out side MD land as directed by the Engineer-in-Charge
10Removing excavated materials not exceeding 50m distance and depositing where directed at level not exceeding 1.5 m above the starting point complete all as per specified and as directed.
11S&F Fly ash bricks using modular bricks as in cable protection cover including taking down existing bricks of any size complete all as per specified and as directed.
12Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil all as specified and as directed.
13S&F XLPEinsulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.
14Note for item No 13 :- Excavation and earth work shall be measured and paid seperately.
15S & F in repair Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armored aluminium conductor cable of size 10 sqmm to 16 sqmm all as specified and directed.
16M & L for cutting existing road/PCC/Drain for laying of DI/GI or any typeof pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mmcomplete all as specified and directed.
17Note for item No 16 :-The tenderer shall take into consideration for following points while quoting his rate for this item andthe unite rate is deemed be included for :-
18(i) Earth work excavation in any type of soil
19(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
20(iii) Removing excavated material to out side MD land
21(iv)Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
22(v)150 mm thickPCC 1:2:4 type B1 as inany type of road
23(vi) GI pipe requiredfor cable protection shall be measured and paid separately under respective item. But labour required for take the cable through GI pipe and laying in trench shall deemed to beincluded in the rate quoted.
24Supply only GI pipe 50 mm bore medium grade for cable protection completeall as specified and as dierced by Engr-in-Charge.
25M & L for disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the 10/16 sqmm 4 core size of LT underground armoured cablescomplete all as specified and directed..
26Note for item No 25 :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted.
27M & L for cleaning vegetation around the LT pole completely root out from soil and clean the surface onemtr around the pole of street lights complete all as specified and as directed.
28Note for item No 27 :- Removing of accumulated earth depth upto 15cm cleaning / Cutting the grass with hand operated petrol/ kerosene driven grass cutting machine andremoving thegrass waste to outside MD land is deemed to be included in quoted rate.
29S&F Powercontactors 40 Amps, 4 pole,415V, including taking down old item complete all as specified and as directed. Make : Cat No 412553 of Legrand or equivalent in approved make in PS
30M & L for preparing surfaces by removing exisiting faded sky blue and white straps on PCC poles and applying a coat of sky blue/white straps painting with synthentic enamel paint, eachsky blue/white straps of 30 cm height up to 1.5 mtr from top of PCC coating, writing pole no with white paint on black base of PCC pole by sentensile measure includingapplaying one coat of synthetic enamel paint to clamps/cross arm/street light GI bracket fixed on pole complete all as specified and as directed
31Supply & fix in repairs PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed.
32M&L Sub main wiring for circuit complete with 2 runs of 1.5 sqmm single core PVC insulated, unsheathed FRLS1100 Volt grade multi stranded copper conductor cable drawn through and incl suitable size non metalic PVC Conduit and accessories complete fixed surface to wall/roof/ceiling etc and 1 run of 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductoretc including taking down existing submain wiring complete all as specified and directed.
33Note for item No 32 :- Two runs of 1.5 sqmmpower cable , one run of 1.5 sqmm earth conductor and one run of PVC conduit will be measured as one length.
34(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
35M & L for removing steel swagedtubular pole 8.5/9 mtr long for providing suitable new bracket for fixingstreet lightand refixing the poleincluding necessary PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) for foundation of 50 x 50 x 45 cm and coping with 1:2:4, type B1 (using 20 mm graded stone aggregate) complete all as specifiedand directed by Engr-in-chrage
36S&F in repairs Connector suitable for fixing of Cable of size Cross sectional area 10 Sqmm to 25 Sqmm armoured/PVC for preventing of Short Circuiting of Cable in Junction Boxes, complete all as specified and as directed.
37M & L for preparing the existing painted steel surface and painting with one coat of aluminium paint on cross arms, clamps, MS flat and street light brackets if any on Steel / RCC pole for Doublecross Arm for three Phase4 wire system.
38Supply and fixing in repairs LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed..
39S&F XLPEinsulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.
40Note for item No 39 :- Excavation and earth work shall be measured and paid seperately.
41Supply, transporting to site, errecting and fixing in position, steel tubular swaged poles of 9mtr longtype 410 SP- 31 IS-2713 marked complete with CI/ MS base plate, finial taper plug, bolts, nuts, washers and screws as specified, drilling of necessary holes including painting with two coats of aluminium paint overa coat of red oxide primer on exposed surface and black bituminous paint on steel surface embeded in conrete externally and throughout internally and painting 03 nos of band /strips with fluorescent , PO box red synthetic enamel paint (30 cm wide each) at a distance of 30 cm from plinth block and number of poles including taking down existing one completeall as specified & directed by Engineer-in-Charge.
42Note for item No 41 :- Earth work excavation, PCC foundation, coping will be measured and paid separately. The rate for pole shall also be included painting to steel tubular pole (in side and out side).
43M&L cement concrete 1:4:8,type D2 (using 40mm graded stone aggregate ) including necessary form work for pole foundation complete all as specified and directed by Engr-in-Charge .
44M&L cement concrete 1:3:6 type C2(using 40mm graded stone aggregate) including necessary form work for pole foundation complete all as specified and directed by Engr-in-Charge .
45M&L PCC 1:2:4 type B-1 using 20mm graded stone aggregates as in pole coping ccompleteall as specified & directed
46S&F Powercontactors 63 Amps, 4 pole,415V, including taking down old item complete all as specified and as directed. Make : Cat No 412557 of Legrand or equivalent in approved make in PS
47M & L for preparing the painted steel surfaces of existing LT steel tubular pole including cross arms, clamps MS flats, steel light bracket if any etc and applying one coat of aluminium paint(above ground/coping level) not exc 8 mtr long including painting of strips of height 0.3mtr each (three nos sky blue and three nos white), writing pole no with black paint with letters/figures 7.5 cm high and tightening of cross arms, clamps and street light brackets complete all as specified and directed.
48S&F LED aviation obstruction light with IP 66 protection water clear poly carbonate UV stabilized dome neoprene rubber with bind spike with 302 Nos LED bulbs including necessary electric connections including 2.5 sqmm, 2 core, PVC copper cables fixed on wall with 20mm dia PVC conduit from DB to light fitting fixed in and including GI pipe 25mm dia 1 mtr long grouted with PCC complete/ binding with existing angle frame etc complete including taking down existing one complete all as specified and directed.Make : Bajaj Cat No - 110731 or equivalent inapproved make in PS
49Attending unserviceable/ non functional street light complaints (for street light/perimeter lights/high mast light/flood light etc of any type/size fitted on poles/walls/post/pillars etc)by deploying technically qualified and experinced techinicians to find out defective/taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws,nuts & bolts and insulation tap to insulate the LT joint etc and testing complete all as specified and as directed for domestic area of old kalpa colony, new kalpa colony, Mehra colony, MAP qrts, Akash enclave, Gulmohar enclave, Kiran enclave, MES colony, AFWWA, various connecting roads and other facilities such as shoping complex/ various institutes/ messes/ play ground, complete perimeter etc located in complete domestic area andtechnical area at AF Station Sulur
50Note for item No 49 :- The following items are deemed to be inclusive of quoted rate :-
51(a)The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced before commencement of work.
52(b)\"Supply only\" items to be delivered/ supplied to AGE E/M store yard as per qty asked by Engineer-in-Charge with in one calender month from the date of commencement of contract and these items will be issued from AGE E/M store yard for attending unserviceable/ defective street light complaints.
53(c)Contractor or his Authorised Representitive has to inspect all Street/ Security Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very Next day.
54(d) A Joint Inspection for Serviceability of all Street/Security Lights will be carried out from 7.00 PM to 9.00 PM on every MONDAY by Engineer-in-Charge/ JE (E/M)/ User alongwith Contractor or his authorised Representitive.
55(e) Contractor has to arrange own moveable Generatorof suitable capacity for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair.No Electricity shall be provided by the Department on this account.
56(f) Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Street/ Security Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipments to remove the breakdown. Fault will be intimated through Telephone/ SMS.
57(g)In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
58(h) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-in-Chargeshall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip.The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive.If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Chargeand the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforceabove as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.The decision of the Accepting Officer is this regards shall be final and binding.
59(j) Contractor has to ensure serviceability of all Street/ Security Lights of DOMESTIC & TECHNICAL AREA on Daily basis in any Weather Condition at their own arrangement.
60(k)Contractor shall provide conveyance to the deployed labour for maintaining the services without any extra cost to department.
61(l)Vehicle mounted ladder for maintaining services shall be provided by the contractor at no extra cost to department.
62(m) Materials requiredfor the repairing of the lights shall be measured and paid separately under respective item(s). But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the street lights fittings shall deemed to beincluded in the rate quoted.
63(n)Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.
64(o)All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor.Contractor will be solely responsible forfull safetyof the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part.
65(p)All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department.
66(q)Attending and repairing complaint for onelightof any type shall be measured and paid as one Job.
67(r)Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items.
68(s) The contractor shall maintain a record of all urgent work at and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
69(t)Contractor shall provide contact details of his responsible person(s) for any emergency.
70(u) Any Materials replaced which are not specified in SCHEDULE OF CREDIT will be deposited to MES STORE YARD without any extra Cost to the Department.
71Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 10 watt, complete all as specified and as directed.
72Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 20 watt, complete all as specified and as directed.
73Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 36 watt, complete all as specified and as directed.
74Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 45 watt, complete all as specified and as directed.
75Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 76 watt, complete all as specified and as directed.
76Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 120 watt, complete all as specified and as directed.
77Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 160 watt, complete all as specified and as directed.
78S & F Galvanised Iron Tubing/Pipe 40mm bore, light grade for Strip Protection, fixed in Walls/Floors with suitable type of Clamps, etc. including taking down old unserviceable one, complete all as specified and as directed.
79S & F in repairs Stainless steel screw/ nut and bolts (machine made) with hexagonal or square heads at one end and screwed the other each screwed end to be fitted with washers and one hexagonal or square nut of dia 5mm to 10mm, n. exc 25mm long complete all as specified.
80S & F Mild Steel Sheet of size approximate 300x200x1.6mm thick Sheet Egg type, Half round type, Rectangular type and Triangular type with welded 1ʺ (Inch) dia 2ʹ (Feet) long Mild Steel Pipe with duly different Synethic Enameled Paint cutting of Equipment Earth/ Lighting Arrester Earth/ Singnal Earth etc. complete as specified duly painted as specified and marking of Earth Plate Number/ Description of Earthing/Type of Earthing on Plate with White Paint including Earth Plate No. and Earthing Resistance with Earthing Check Date and Earthing Check Due Date including taking down old unserviceable one, complete all as specified and as directed
81S&F XLPEinsulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 10 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.
82Note for item No 81 :- Excavation and earth work shall be measured and paid seperately.
83Supply and fixin replacement of high power LED street light fittings energy saving luminaire with lens , capacity 45 watt with system efficacy (lm/w) shall be 100 lumenper watt or more lumens per watt, total system lumen not less than 3600 lumens, PF not less than 0.95, CRI not less than 70,colour temp. 5000K to 6500 K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housingIP-65/66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz ( + 5%), THD< 10% completeincluding taking down existing complete all as specified and directed.
84S&F XLPEinsulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 10 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.
85S&F XLPEinsulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 6 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed.
86Note for item No 84 & 85 :- Excavation and earth work shall be measured and paid seperately.
87Supply and fixin replacement of high power LED street light fittings energy saving luminaire with lens , capacity 90 watt with system efficacy (lm/w) shall be 100 lumenper watt or more lumens per watt, total system lumen not less than 3600 lumens, PF not less than 0.95, CRI not less than 70,colour temp. 5000K to 6500 K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housingIP-65/66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz ( + 5%), THD< 10% completeincluding taking down existing complete all as specified and directed.
88S & F synchronising electronic timer unit operated on AC 230 Volts, 24 hrs clock time for controling street lights including taking down old unserviceable timer switches complete all as directed. Make :-Cat Part No : 4126 41 of Legrand or equivalent in approved make in PS
89M & L cleaning of existing solar street light panels fixed above street light pole of approximate height 6 meter by using wet cloth dipped in soap water including the panel perimeter complete all as specified and directed.
90Note for Item No 89:- (i) The contractor shall be responsible for arrange necessary conveyance vehicle, Aluminium self supporting ladder/bamboo ladder, bucket, soap powder, cloths etc and the quoted rate shall be deemed to be inclusive for the above.
91(ij) Contractor has to ensure serviceability of solar street light panel of DOMESTIC & TECHNICAL AREA on Daily basis in any Weather Condition at their own arrangement.
92(iii)Contractor shall provide conveyance to the deployed labour for maintaining the services without any extra cost to department.
93(iv)Vehicle mounted ladder for maintaining services shall be provided by the contractor at no extra cost to department.
94(v)Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.
95(vi)All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor.Contractor will be solely responsible forfull safetyof the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part.
96Supply and fix IP 66 Thermoplastic PC- GFS Polycarbonate weatherproof Junction Box size 255L x 205B x 112D MM with plain walls for cable entries to be drilled individually, system voltage : 415V, 50hz,The plain side walls on the four sides can be drilled and customized for cable entries from any direction. Lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories.Cable terminal :- 25 Sq mm- 4 no with 10A SP MCB- 1 no, 6sq mm disconnected terminal- 1 no, The junction box shall fulfill the following standards Weather proof : UV resistant due to solar radiation, Rainwater proof, temperature resistant.Salt water proof & shall be suitable for off-shore applications. IEC 60670-22 : Particular requirements for connecting boxes and enclosures. IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 960 deg C. IEC 60529 : IP 66 / IP 67 / IP 69 degree of protectionincluding taking down existing all as specified and directed.Make of junction box shall be as per make mentioned in list of makes in PS.
97Taking down carefully hanger lights for repair/ replacement of defective spare parts such as ballast, etc including taking down old one of any capacity from 150 watts Flame Proof light including cleaning internally and externally fixing back the fitting in same position after repair and test complete all as specified and as directed.
98Note for Item No 97:-Following shall be part of job under this item :-
99(a)The above job shall be carried out by a trained electrician
100(b)All sort of petty T&P items such as PVC insulation table, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
101(c) Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, cranes etc. shall be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate
102(d)All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor.Contractor will be solely responsible forfull safetyof the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part.
103Supply and fix in repairs flame proof electronic LED driver suitable for flame proof flood light fitting 150W sun shelter down light/ flood light fitting complete all as specified and directed.
104M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and including suitable size steel conduit and all accessories fixed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed.
105Note for item No 104 :- (a)2 runs of 4 sqmm cable along with onerun of 4 sqmm cable for earth conductor and one run ofsteel conduit shall be measured as one length.
106(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
107M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and including suitable sizesteel conduit and all accessories fixed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed.
108Note for item No 107 :- (a)2 runs of 6 sqmm cable along with onerun of 6 sqmm cable for earth conductor and one run of steel conduit shall be measured as one length.
109(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
110S&F in repair Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
111Supply and fixing in replacement of switch flame proof switch socket and plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P + earth, complete all as specified and directed
112Supply and fixing in replacement of LUMINAIRE WELLGLASS LED ZONE I-Gr IIC LM6 Die cast Aluminium LM6 housing, 230V AC, 50 Hz Suitable for 150W LED fitting with 2 Nos of 0.75ET cable Entry, Neoprene gasket , Stainless steel Hardware, Epoxy powder coating light grey finish shed 631/IS-5 with cable gland, plug & lamp complete all as specified and directed. Make cat No FLPW-2595/II C/L of Sudhir, equivalent in approved make in PS
113S&F in replacement of cable tray perforated type of size 100 x50mm made out of 1.6mm thick GI sheet fixed in PEB structure by providing MS angle 40x40x5mm clamps etc including fittings like bend, tee and making good the disturbed portion and matching with existing surface complete all as specified and directed
114Supply and fix in repair high power LED street light fittings energy saving luminaire with lens , capacity 70 watt with system efficacy (lm/w) shall be >115 lumenper watt or more lumens per watt, Beam angle - Road Optic, total system lumen not less than 8200 lumens, PF not less than 0.95, CRI not less than 70,colour temp. 5700K, surge protection not less than 4 KV, high pressure die cast aluminium alloy LM6 housingIP-65 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50/60 Hz ( + 5%), THD< 10% complete all as specified. Make : Philips cat pat No. BRP409 LED82 CW M2 FG PSU OD40 P4498 or Equivalent approved make in PS
115Supply and fix in repair PVC insulated Copper Conductor Cable 2.5 Sqmm, 3 Core Round Flexible for connection of flood Light Fitting, complete all as specified and as directed.
116Supply and fix in repair GI tubing 40/50 mm bore light grade 1.2 mtr long bent to shape as required with clamps for fixing of street light on poles/ walls including nuts, bolts, washers clamps of suitable sizecomplete all as specified and as directed.
117Supply and fix in repair GI tubing 25 mm bore light grade (1.2+0.6 mtr long) bent to shape of \"Y\"for fixing two street lights in one bracket on wall in the area of low level lighting as required with clamps for fixing of street light on poles/ walls including nuts, bolts, washers clamps of suitable size complete all as specified and as directed.
118Supply, transporting to site, errecting and fixing in position, steel tubular swaged poles of 11 mtr longtype 410 SP- 55 marked complete with CI/ MS base plate, finial taper plug, bolts, nuts, washers and screws as specified, drilling of necessary holes including painting with two coats of aluminium paint overa coat of red oxide primer on exposed surface and black bituminous paint on steel surface embeded in conrete externally and throughout internally and painting 03 nos of band /strips with fluorescent , PO box red synthetic enamel paint (30 cm wide each) at a distance of 30 cm from plinth block and number of poles etcincluding taking down existing one completeall as specified & directed by Engineer-in-Charge.
119Note for item No 118 :- Earth work excavation, PCC foundation, coping will be measured and paid separately. The rate for pole shall also be included painting to steel tubular pole (in side and out side).
120Supply and fix in repair cross arm using standard mild steel sections like angle iron / MS pipe / flat iron / nut bolt and washers etc using steel of Fe 410-W (Gde E-250) quality - A including necessary welding suitable to fixing of flood lights on pole complete all as specified and directed by Engr in charge.
121Supply and lay GI pipe 40 mm bore light grade for cable protection including taking down existing pipe completeall as specified and as dierced by Engr-in-Charge.
122Supply and fixing in repair LED flood light fitting 75 Watts 240 Volts, (suitable for fixing on pole/ wall) with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 class of protection complete with control driver and all accessories with high quality lenses, reflector, and toughened glass, power factor > 0.95, Luminaire lumen output - 8200lm, operating voltage range from 140V to 270V at 50 Hz AC Frequency, Temperature range-40 to +70 deg Celsius, driver efficiency > 85%, THD<10%, CRI>70%, Colour temperature 5700K, Surge protection from overvoltages 4kV internal and 10kV external, 50000 burning hours, Luminaire efficacy-110 lm/w complete all as directed.Make : Philips CatNo BVP192 LED 82 CWHO NB FG GR PSU or Equivalent in approved make in PS
123Supply and fixing in repair LED flood light fitting 160 Watts 240 Volts, (suitable for fixing on pole/ wall) with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 class of protection complete with control driver and all accessories with high quality lenses, reflector, and toughened glass, power factor > 0.95, Luminaire lumen output - 17600lm, operating voltage range from 140V to 270V at 50 Hz AC Frequency, Temperature range-40 to +70 deg Celsius, driver efficiency > 85%, THD<10%, CRI>70%, Colour temperature 6500K, Surge protection from overvoltages 4kV internal and 10kV external, 50000 burning hours, Luminaire efficacy-110 lm/w complete all as directed.Make : Philips CatNo BVP192 LED 172 CWHO NB FG A1 GR PSU or Equivalent in approved make in PS
124Supply and fixing in repair LED flood light fitting 210 Watts 240 Volts, System wattage 195 W, (suitable for fixing on pole/ wall) with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 class of protection complete with control driver and all accessories with high quality lenses, reflector, and toughened glass, power factor > 0.95, Luminaire lumen output - 23500lm, operating voltage range from 120V to 277V at 50 Hz AC Frequency, Temperature range-40 to +70 deg Celsius, driver efficiency > 85%, THD<10%, CRI>70%, Colour temperature 5700K to 6500K, Surge protection from overvoltages 5kV internal and 10kV external, 50000 burning hours, Luminaire efficacy-160lm/w complete all as directed.Make : Philips CatNo BVP483 LED 235 CW AMB PSU GR or Equivalent in approved make in PS
125Supply and fixing in repair convetional type post topfitting with LEDPost tops lamp fitting 1x45 W LEDmade die cast aluminium with innovative glare free indirect lighting ditribution & IP 65 protectioninlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground complete all as specified and as directed.Make : CG Cat No. LPTO-40-CDL/Bajaj Cat Part No. BRIL 45 W LED NW or Equivalent in approved make in PS
126Supply and fixing in repair ALCOR LED flood light, 50 watts RGB colour changing light, 240 Volt, with high quality lenses & reflector, High grade aluminium pressure Die-Cast Housing with toughened glass cover, IP-66 class of protection, complete with control gear and all accessories including necessory PCC foundation for placing of flood lightcomplete all as specified and directed by Engr in charge. Make : Luker cat pat No. LFLR 50 or equivalent in approved make in PS
127Supply and fixing in repair pathway light decorative retrofit LED fitting with 9 W LED bulb including necessary excavation, PCC foundation, 1.5 mtr long GI pipe light grade 50 mm bore with base plate, cable junction box with 2 pole connector 32 A capacity including cable entry and exist knockouts, 1.5 mtr length 3 core 1.5 sqmm PVC insulated copper round cable from connector to light fitting, disposal of soil to outside MD land complete all as specified and directed by Engineer-in-Charge. Make / Model of Light fitting : Athena 3 (MOON) of Havells Cat Part No : LHDC11126099 or equivalent in approved make in PS
128Supply and fixing in repair convetional type boolard fitting with LED bollard light fittings suitable for 1x9 watt LEDbollard in rectangular shaped vicotria design with opal acrylic diffuser and IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed.Make /cat part No. CG cat no.LBLSN-10-CDL or equivalent in approved make in PS.
129Supply and fixing in repair Revolving search light 300 W LED High intensity, long range, weather proof, energy saving, instant glow, LED search light, beam range 700 meters (as per model), Single LED light, Efficiency >140 lm/w, PF >0.95, CCT ~ 6000K, Optical grade PMMA-PC lens, narrow beam 8 degree, die cast LM6 body with air fins, toughened front glass sealed with silicon gasket, fully powder coated, wide range of working voltage 90 - 300 AC, protection against over volt & under volts, reflector lens efficiency >90%, average lux level at 10 meter is approx. 2000 - 6000 lux (as per model) with circle of approx 1meter, confirming to LM79 & LM80. This search-light is ready to installed on rotating disc of auto revolving mechanism. Degree of protection : IP65 and the stand would be suitable for mounting of search lights on its rotating disk on top side. It is made of iron/steel with epoxy powder coating weather proof paint on surface. The stand has designed so that the search light can be rotate one full round horizontally and 30 degree vertically & can be locked at any position at any time. It would be 4 nos. high grade PVC castor wheels at bottom for easy movement on the platform with wheel locking arrangement. The height of tripod stand is generally 1 Meter above from the bottom. Make /cat part No:- KALIN ENGINEERING WORKS cat no.TRI - LRFLL25-PC30 or equivalent approved make.
130Supply and fixing in repair Integrated solar street light of less than 28W with 4500 lumen and system lumen efficiency of more than 170 lumen per watt. The luminaire shall use highly efficient microcontroller based integrated MPPT charge controller, both charger and driver to be on same board with more than 90% efficiency of both charger and driver. High grade aluminium die-cast housing to ensure good heat dissipation. The luminaire shall have flexi mount of 0 to 15 degree to adapt to certain geography diversity. The luminaire shall be with smart self-diagnosis feature with LED indicators alongwith battery charging and deep discharging out off indications. The system shall use long time maintenance free lithium Ferro Phosphate (Li Fe PO 4) battery with BIS certification. Battery capacity of minimum 170 wh for autonomy of 24 hrs with fully charged battery. The luminaire shall be with hybrid feature (integrated/ seperated)ON-OFF switch, Outer mounting diameter of 48-60 mm. Operating temp range for light engine is 0 to +35 Dep C. operating humidity shall be upto 95%. System lumen output should be atleast 12V DC, 2000 lm. Solar panel module capacity of 12V, 35W Peak Mono-crystalline. Solar cell efficiency with min 12%. LED burning hrs to be 50,000 hrs at L70. Rating of IP 65 and IK 08 to comply with UV stabilized poly carbonate front cover. Colour temp of 5700K and CRI > 70 including taking down existing one all as directed.Make : Philips Cat No BRP 710 LED 45 CW MR HY FDIM 50 Solaror equivalent in approved make in PSNote :- The unit rate is deemed to included for 6 mtr long MS/GI pipe of 50MM bore medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engr-in-Charge
131Notes for Item No 130:- (a)The contractor shall submit to Engr-in-Charge LM-80 and LM-79 reportincluding BIS certification. (b)The contractor shall submit warranty certificate from manufacturer for minimum 5 years.(c)The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.(d) The contractor shall also submit safety and performance standard compliance of IEC 60598-2-3 for road and street lights, IEC 62109-1 for power converters used in Solar Panel, EN 50530 for MPPT performance evaluation, IEC 61607 for EMC immunity, CISPR 15 for Radio disturbance characteristics, IEC 62133, IEC 61960 and UL 1642 for safety of lithium Ferro Phosphate battery and IEC 61730-1, 2 & IEC 61215 for safety of solar panel module. (e) The rates quoted deemed to be included 6 mtr long GI pipe of 50mm bore medium grade including necessaryexcavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engineer-in-Charge.
132Supply and fixing in repair Triglow rope light 18mtr length IP 65 water plug and play strip light for republic day and independence day celebration showcausing patriotism for India . Indian tricolour strip light - orange +whitw+green colour in single strip . Wattage -6W/Meter Lumen output 400lm/meter, input volt- 220V to 240V all as directed.

AI Tender Summary

OUR REF NO 45278087
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 08-10-2024
Authority
Authority Name Military Engineer Services
Work Description REPAIR / MAINT OF DAY TO DAY COMPLAINTS OF PERIMETER STREET LIGHTS, AREA LIGHTS, HIGH MAST LIGHTS, SOLAR LIGHTS AND CERTAIN E/M WORKS AT AF STN SULUR
Basic Detail
Tender No 8693/E8
Bidding Type Tender
Location
City sulur
State Tamil Nadu
Key Dates
Publish Date 17 Sep 2024
Submission Date 08 Oct 2024
Open Date 10 Oct 2024
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 90000
Exemption Available
Document List
21447c0c-6ddc-4b39-909a-cec5ed2aa5d9.html
8693TENDER.pdf
BOQ_754710.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 17, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 08, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 10, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

21447c0c-6ddc-4b39-909a-cec5ed2aa5d9.html

pdf

8693TENDER.pdf

xls

BOQ_754710.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders