| 1 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.Avg run 9 mtr. |
| 2 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works.On Board |
| 3 | Supply & Fixing of 415V, 25/36 KA, 160 A , 4 Pole MCCB with sheet steel enclosure with Cabaling Box 2 Nos.on flat iron/angle iron frame on wall with nuts & bolts etc .[For Main Switch] |
| 4 | Supply & Fixing of 415V, 25/36 KA, 100 A , 4 Pole MCCB with sheet steel enclosure with Cabaling Box 2 Nos.on flat iron/angle iron frame on wall with nuts & bolts etc . [For Floor wise Distribution] |
| 5 | Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991)4 bars - 415V, 200A, 4 x 50 x 5 mm, 500 x 150 mm |
| 6 | Supply & Fixing double door 8 Way Vertical TPN MCB Distribution board and MCCB incomming with IP -42/43 protection, as follow with vertical busbar system, on angle iron frame on wall & mending good damages to original finish incl. connection with suitable size of copper wire and neutrallink & provision for earthing attachment with both side cable end box as per direction of EIC. (Legrand)[For DG]Incomer:125 A, 35 kA, 4 pole MCCB -1 No. Outgoing:63 A , 10 kA , TP MCB - 5 nos.(Make - Legrand) |
| 7 | Supply & Fixing double door 8 Way Vertical TPN MCB Distribution board and MCCB incomming with IP -42/43 protection, as follow with vertical busbar system, on angle iron frame on wall & mending good damages to original finish incl. connection with suitable size of copper wire and neutrallink & provision for earthing attachment with both side cable end box as per direction of EIC. (Legrand)[For 2nd Floor, Outgoing Lines to TPNDB, AC & Geyser Points]Incomer:100 A, 35 kA, 4 pole MCCB -1 No. Outgoing:i) 63 A , 10 kA , TP MCB - 1 no.ii) 6A-32 A , 10 kA , SP MCB - 21 nos.(Make - Legrand). |
| 8 | Supply & Fixing double door horizontal 6 Way TPN MCB Distribution board with IP -42/43 protection, concealed in wall after cutting the wall & mending good damages to original finish incl. inter connection with suitable size of copper wire and neutrallink & provision for earthing attachment as per direction of EIC. (Legrand)[At 2nd Floor, Outgoing Lines to LDB-1, LDB-2 & Computer Points]Incomer:i) 63 A,10 Ka,4 pole MCB Isolator - 1 No.Outgoing:i) 6A -32A ,10 Ka, ‘ C’ curve SPMCB - 18nos. (Make - Legrand). |
| 9 | Supply & Fixing double door 2+12 way SPNMCB DB with IP -42/43 protection on wall as per direction of EIC. (Legrand)[At 2nd Floor as LDB-1 & LDB-2]Incomeri) 40 A, DP Isolator - 1 No. Outgoingi) 6A -32A ,10 kA, ‘ C’ curve SPMCB - 12 Nos.(Make - Legrand). |
| 10 | Laying of 1.1KV gr. XLPE Ar./Al. Cable by shaddling on wall with 2nos. 10 SWG G.I earth continuity wire.Laying of 4 Core 25 sq mm Cable (from VTPN DB to TPN DB) |
| 11 | Laying of 3.5 Core 50 sq mm Cable(from Energy Meter to Main BasBar through Main Switch) |
| 12 | Supply & Fixing of compression type cable gland complete with Al. socket finishing the ends of the following cables by crimping method as perdirection of EIC as below:For 4 Core 25 sqmm XLPE cable |
| 13 | For 4 Core 50 sqmm XLPE cable |
| 14 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[For Seperate Power Plug Points] |
| 15 | Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[For Seperate Plug Points] |
| 16 | Supplying & Fixing GI Modular Switch Board of 2 Module complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works[For Geyser Points] |
| 17 | Supply & Fixing 240 V 16 A Modular type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required. [For Geyser Switch] |
| 18 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [For Geyser Point] |
| 19 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 20 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch (make- Anchor, Vinay, havells) with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required as directed by EIC. |
| 21 | Supply & Fixing 240 V, 1no. 25 A, AC starter (suitable for 1.5 to 2 ton AC) with 25A DP MCB and 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc. as per direction of EIC. [for AC point] |
| 22 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), incl. 240V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy.connections with PVC Cu wire and earth continuity wire etc. as per direction of EIC. [For AC Socket] |
| 23 | Supply & Laying 20mm PVC rigid conduit \"FR\" (Precision make) on wall, ceiling with saddling & other accessories as reqd. & mending good the damages to building works. |
| 24 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required2X6 sqmm +1x 4 sqmm [TPNDB to SPNDB] |
| 25 | 2 x 4 sqmm + 1 x 2.5 sqmm [ VTPNDB to AC points & Geyser points] |
| 26 | 2 x 2.5 sqmm + 1 x 1.5 sqmm [TPNDB to Power plug points & Computer plug points] |
| 27 | 2 x 1.5 sqmm + 1 x 1.5 sqmm [for 5A separateplug point & call bell point] |
| 28 | Fixing only ceiling fan complete with blades, canopy, fork, rubber, bush etc. including S&F connecting wire for down rod up to 30cm including painting the rod with approved paint and making necessary connection as required by 2x1.5 sq.mm flexible copper wire. |
| 29 | Fixing Only single /twin fluorescent light fitting complete with all accessories directly on wall /cilling/HW round block on wall with suitable size. |
| 30 | Fixing only single / twin fluorescent light fitting suspended 25cm below the ceiling with 2nos. 20mm dia E.I. conduit (14 SWG) supports fixed with \"L\" type MS clamp whose one side fixed on ceiling with suitable size 4nos. fastener & other side connected with the conduit with suitable size of bolts & nuts incl. S&F E.I. conduit, \"L\" type MS clamp & connecting the length of PVC insulated wire & mending good the damages to original finish & painting etc. by 2x24/0.20mm (1.5 sqmm) flexible copper wire of 1.10mt. length. |
| 31 | Fixing angular batten holder (Anchor) With 18 W LED Lamp. on 75mm dia PVC round block / round bakelite on wall / ceiling |
| 32 | Extra for suspension exceeding 25cm with S&F additional 2nos. 20mm dia E.I. conduit (14 SWG) supports & necy. PVC insulated wire & painting etc. as reqd. by 2x24/0.20mm (1.5 sqmm) flexible copper wire of 1.10mt. length. |
| 33 | Fixing only exhaust fan 240V 300 mm sweep 920 rpm heavy duty after making good damages & smooth cement finish etc. as practicable as possible & providing necy. length of PVC insulated wire & making connection for exhaust fan incl. S&F Al. louver shutter on wall with necy. bolts & nuts (6mm dia x 62mm long). |
| 34 | Supply & Fixing 250V AC/DC superior type Call Bell (Anchor) on HW board incl. S&F HW board. |
| 35 | Supply & Fixing of Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level. (ISI medium G.I. pipe) |
| 36 | Supplying and fixing 415V, 125A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc [Make - L&T] |
| 37 | Supply & Fixing earth busbar of galvanized (Hot Dip) MS flat 25mm x 6mm on wall having clearance of 6mm from wall incl. providing drilled holes on the busbar complete with G.I. bolts, nuts, washers, spacing insulators etc. as reqd. |
| 38 | Add GST @ 18% |
| 39 | Add Labour Welfare Cess @ 1% |