| 1 | Supply and fix anti-bird net UV black in colour made of materials polyfin all weather proof co-polymer of machine heat knotting using CNC machines with DSLS technology for antislip knotting heat setting shall be stream set for greater dimensional stability and knot firmness and dia meter of the mesh shall be 1 mm and the size of mesh 25mm x 25mm (± 2mm) and shall achieve twin strength of 16 Kg minimun mesh breaking str (MBS) 12kgf and KBS 22kgf minimum, fixed complete all as per manufactures instruction in trusses.Bird proof arrangment shall be fixed/tied to truss members with nylon wire as per manufacture\"s instructions.Makes: Leo Techonova India /pigeon control india(08048044740) or its equivalent as approved by the GENote : The fixing of Anti - Bird Net at heiht of 12.20 Mtr or above from ground level oras directed by GE, hence contractor may quote their rates considering this aspects. |
| 2 | M&L for preparation of old painted steel surfaces of any description,over 10 cm in width or girth, not other wise described and applying one coat of synthetic enamel paint ordinary tint complete all as specified and directed.Note: Rates includes for scaffolding and for execution of work at height of 12.20 Mtr or abovefrom the ground level as specified and directed hence contractor may quote their rates considering this aspects. |
| 3 | S&Fframed work such as grills, gratings etc with ends ofbar shoulders and /orriveted or forged into spikes framed guard bars, barred iron doors, ladders, framework of water tank and similar work withfe -290 Gde-E-165 complete all as specified and directed.Note : Rates include for execution of work at height of 12.20 mtr or above from the ground level asspecified and directed hence contractor may quote their rates considering this aspects. |
| 4 | M&L for preparation of new steelsurfaces of any description over 10 Cm in width or girth, not other wise described and applying two coats of synthetic enamel paint (ordinary tint) (each coat) over a coat of red oxide primer complete all as specified and directed. |
| 5 | Surface excavation n. exc 30 Cm deep and averaging 15 Cm deep and getting out in hard/dense soil complete all as specified and directed. |
| 6 | Excavating in post holes (or similar holes) each n exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed. |
| 7 | Excavation in trenches not exceeding 1.5 M wide and exceeding 1.5 M but not exceding 3.0 M depth for foundation etc and getting out in hard/ dense soil complete all as specified and directed. |
| 8 | Removing excavated material to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 9 | Material and labour for brick work built in cement mortar 1:6 straight or curved on plan exceeding 6 metre mean radius using sub class ‘B’ bricks (Old size bricks) complete all as specified and directed. |
| 10 | M & L for PCC1:3:6 type C2 (using 40mm graded stone aggregate) infoundation filling mass concrete complete all as specified and directed. |
| 11 | Material and labour for 15mm thick rendering in cement mortar 1:4 on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) etc complete all as specified and directed. |
| 12 | M&L for hard core of broken stone boulders of guage not exc 63mm deposited, spread and levelled in layers not exc 15cm thick watered and rammed to a true surfaces complete all as specified and directed. |
| 13 | M&L for 100 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specfied and directed. |
| 14 | M&L for machine pressed precast concrete interlocking paver block of any shape and size conforming to IS-15658-2006 of60mm thickness M-35m gradejointed with grey cement and pigment complete all as specified and directed. |
| 15 | Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 16 | M&L for plain cement concrete 1:2:4 type B1(using 20mm graded stone aggregate) as on roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 17 | S&F Pre-painted galvalume aluminum zinc coating trapezoidal/ corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 18 | S&F mild steel Fe-410-W(GdeE-250) quality-B Rolled sections as in Joist, channel, angle or tee sections, fixed independently, without connecting plates etc (cut to ordinary lengths i.e. within 20mm of the length indicated complete all as specified and directed. |
| 19 | S & F Steel work in Roof trusses (framed) trussed purlins, crane gantries purlins, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces cleats etc complete all as specified and directed. |
| 20 | M&L for painting to steel Surfaces of any description, over 10cm in width or grith with two coat of synthetic enamel paint over a coat of red oxide primer, not otherwise described complete all as specified and directed. |
| 21 | S&F mild steel Fe-410-W(GdeE-250) quality-B Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and directed. |
| 22 | M&L for preparation of newplastered surfaces of walland applying two coats of cement base paint complete all as specified and directed. |
| 23 | M & L for Point wiring with 1.5 Sq mm copper conductor single core PVC insulated unsheathed FRLS 1100 Volts multistranded drawn through and including rigid PVC casing & caping and its accessories of suitable size, high grade ISI markedin walls /roof and PVC boxes of suitable size including fixing/grouting sunken/ surface as per site requirement for mounting the switches / sockets/ regulators etc including running up of 1.5 Sq mm copper conductor flame retardant PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and directed. |
| 24 | One light/fan point controlled by one way switch 5/6 amps. |
| 25 | One socket out let 5/6 amps point on the same board |
| 26 | S&F switch piano flush type 5/6 amps single pole one way complete all as specified and directed. |
| 27 | S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed. |
| 28 | S&F in ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed. |
| 29 | S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range-140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and directed. |
| 30 | S&F of Bulk head luminaire suitable for 10 WattLED (or nearest next higher wattage) light IP66 grade, luminaire efficiency not less than 120 lumens/watts with and including 10 watt LED (or nearest next higher wattage) lamp and connecting up with and including PVC insulated3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified and directed. |
| 31 | S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 4 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, ertth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete all as specified and as directed. |
| 32 | S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA with and including taking down old unsv onecomplete all as specified and directed. |
| 33 | S&F MCB, Single pole, 5 to32 amps, 240 volts, ‘C’ curve, 10 KAcomplete with and including taking down old unsv one complete all as specified and directed. |
| 34 | Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, includig necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 3 of SSR Part- I including testing on completion complete all as specified and directed. |
| 35 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulatedPVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 10 sqmm 2 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete all as specified and directed.NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule \"A\". |
| 36 | Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / layingunder ground electric cable in soft/loose soil complete all as specified and directed. |
| 37 | Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and directed. |
| 38 | Supply and laying sub class B bricks of size 23cm x 11.50cm x 7.50cm (+/- 10% tolerance) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and directed. |
| 39 | M & L for horizontal boring across the existing road without disturbing the road surface for insertingGI pipe complete all as specified and directed. Note :- (i) Removal of surplus soil shall be deemed to be included in the unit Rate quoted for this item. (ii) GI pipe will be measured and paid separately under relevant item of this BOQ. |
| 40 | M&L for 32 mm bore GI tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and directed. |
| 41 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |