Tender For Additional / Alternator To Officer Mess And Air Force School Bldg No P 322 Alongwith Allied Works At Afs Kumbhirgram
Tender Overview
Project Description
Tender For Additional / Alternator To Officer Mess And Air Force School Bldg No P 322 Alongwith Allied Works At Afs Kumbhirgram
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-Oct-2024 | Amendments in BOQ | BOQ | 12-Oct-2024 |
| 2 | 12-Oct-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 19-Oct-2024 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches n exc 1.5m wide and n exc 1.5mtr in depthfor foundation etc n exc 10 sqm on plan and getting out in soft / loose soil.complete all as specified and as directed. |
| 2 | Material and labour for Plain Cement concrete 1:3:6 type C2 using 40mm aggregate as in foundations,filling and mass concrete complete all as specified and as directed. |
| 3 | M&L for RCC (M-25) 20 mm graded aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and as directed. |
| 4 | M&L for RCC (M-25) 20 mm graded aggregate Columns, pillars, piers, posts and struts all as specified and directed. |
| 5 | &L for Flat Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter all as specified and as directed. |
| 6 | M&L for Flat Formwork to sides of pillars, posts, struts, piers, columns and stanchions with fair finished surfaces all as specified and as directed. |
| 7 | M&L for Mild steel bars 10mmdia and over(TMT bars FE-500 grade), cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed. |
| 8 | Ditto, but 6mm to 8mm diaas in stirrups, spacers and binders all as directed |
| 9 | M&L for Plates (plain or chequered) Fe- 290 (Gde E- 165) quality-A channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment all as specified and as directed. |
| 10 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm and n exc 10cm, (dia of neck 11 to 15mm) all as specified and directed. |
| 11 | S & F steel work in tubular trusses including special shaped washer etc complete using ERW or inductionbutt welded tubes conforming to IS 1161-1998 grade St- 240 all as specified and directed |
| 12 | M&L for two coats of synthetic enamel paint over a coat of red oxide zinc chromeof new steel Surfaces of any description, over 10cm in width or girth,not otherwise described all as specified and directed. |
| 13 | M&L for Excavating over areas in soft soil, n exc 1.5 m deep and getting out all as directed and specified. |
| 14 | M & L brick work with sub class \"B\" brick straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 15 | Materials and labour for 15 mm thick rendering in cement mortar (1:4) on brick/concrete surface finished even and fair without using extra cement , complete all as specified and as directed. |
| 16 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 17 | M&L for Hardcore of gauge of broken stone or bouldersn exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and as directed. |
| 18 | M&L Cement Concrete(1:2:4) type B2 using 40mm grade stone aggragete in flooring complete all as specified and as directed. |
| 19 | S&F pre- painted galvalume aluminum zinc coating GI Based corrugated steelsheeting 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, chajjas,fixedwith self tapping screws complete all as specified & directed |
| 20 | S&F pre- painted galvalume aluminum zinc coating GI Basedplan corrugated steelsheeting 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, chajjas,fixedwith self tapping screws complete all as specified & directed |
| 21 | M&L Fiber Frp Faisal Lite Transparent Roof Sheet, Thickness: 1mm - 6mm thick Transparent / milky White light transmitting construction material, offering light transmittance over 85% made of the thermosetting plastic reinforced plastic sheet which is resistant to aging, corrosion, wearing, and high temperatures etc complete all as specified and directed by Engr-in-Charge. Make : Kana Advanced Composite Industries , Gujarat or equivalent all as specified and directed by Engr-in-Charge. |
| 22 | M&L 75mm thick PCC 1:2:4 type B2 using 40mm graded stone aggregate Finishing cement concrete surface even and smooth as in sub base floor all as specified. |
| 23 | Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm thickness and removing rubbish from the site of work complete all as specified and as directed |
| 24 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc all as specified and as directed. |
| 25 | M&L for 25mm thick PCC 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregate) as in sub floor under tiles complete all as specified and as directed. |
| 26 | M&L for Non-skid ceramic white tiles 7-8mm thick area of each tile exceeding 0.18Sqm but n.ec 0.38Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified and directed. |
| 27 | Demolition ofRCC Column and removal of debris to a distance n.exc. 50 mtrs and spreading complete all as specified and as directed. |
| 28 | Demolition of brick work built in cement mortar in any position and removal of debris to a distance n.exc. 50 m and spreading complete all as specified and as directed. |
| 29 | M&L for RCC (M-25) 20 mm graded aggregate Beams, cantilevers, lintels, columns pillars, piers, posts, struts, chullah hoods, stair case, arches, domes, vaults, shell roofs, arch ribs, folded plates, slabs,balconies, canopies, deck slabs etc. or in similar articles upto 5th floor level all as directed and specified |
| 30 | M&L for RCC (M-25 Design Mix) 20 mm aggregate Beams, cantilevers, bressummers, lintels over 1.5m span |
| 31 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. |
| 32 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in, built in cm 1:4 complete all as specified and directed. |
| 33 | All as per per Item No 26 above but in skirting |
| 34 | Materials and labour for rendering 15mm thick cement plaster on in two layers each of 10+5mm thick in Cement Mortar (1:4) with LW + @ 200ml/50Kg of cement on fair faces of brick work completeallas specified and directed.(Note :Integral water proofing compound shall be measured and paid separately under respective item of BoQ) |
| 35 | Supply only LW + confirming to relavent IS MAKE : Dr. Fixit of M/s PIDILITE INDSTURIES or equivalent |
| 36 | Materials and labour for 10 mm thick rendering in cement mortar (1:6) on brick/concrete surface finished even and smooth without using extra cement , complete all as specified and as directed. |
| 37 | Materials and labour for preparing of New surfaces of wallsand applying two coat of oil emulsion paint (interior grade) on the same after complete removing the existing treatment and preparation of internal wall surfaces and appying one coat of primer, all complete as specified and as directed. |
| 38 | Supply and fixing in repairs PVC Eaves board size 250 mm wide and 18mm thick, over lapping with solvent cement and fixing by stainless steel screw with suitable washers complete all as specified and as directed. |
| 39 | S&F Mild steel sheet eaves gutters thick ness 1.25 mm and dia 150 mm, galvanised class 3, half round with rounded edges all as directed and specified |
| 40 | M&L framed work such as grills, gratings, gate etc with ends of barssouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railing, frame work of water tanks and similar work conforming to Fe-290, Gde E-165 complete all as specified and directed. |
| 41 | Supply and fixing PVC (SWR) rain water pipe 110 mm bore in any length with rubber joints , ISI marked fixed to wall complete all as specified and as directed. |
| 42 | S&F 110 mm PVC (SWR) bends any radiusall as specified and directed. |
| 43 | S&F for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 44 | Supply and fix anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed. Make: HINDALCO/JINDAL |
| 45 | S&F 5.5 mm Sheet glass,ordinary quality and glazing with oil putty in square but exc 0.5 sq. m in each pane including solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers all as specified and as directed. |
| 46 | S&F10 mm PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawingall as specified and directed. |
| 47 | S&F for Rolled sections Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. |
| 48 | S&F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connectedto common rafters and running rails and guides for sliding doors; fixedwithangle cleats or other connecting platesFe 410 -W (GdeE- 250) qualityA |
| 49 | S&F Plates (plain or chequered) Fe 410 -W(Gde E- 250)quality A channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, with riveted, bolted or welded attachment as directed |
| 50 | M&L for MS Screw bolts wqith hexagonal or square heads at aone end and screwed other or screw bo th ends n exc 5 cm long or as directed and specified |
| 51 | Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap eading, screws etc. complete all as specified |
| 52 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperure 1.40 mm and fixedwith stainless steel wire staples fixed complete all as specified and directed. |
| 53 | Supply and fixing 4 mm thick, AC plain building boards fixed to timber frame work with screws as in ceiling complete all specified. |
| 54 | Supply and fix GI frame work for seamless ceiling605x605 mm grid comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centreand including6mm dia GI hanger (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and as directed. |
| 55 | Material and labour for 50 mm thick cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in sub base floor,or in hard standing, finished even and rough complete all as specified and as directed. |
| 56 | Materials and labour for pre polished chequered cement concrete tiles 30cm x 30cm x 20mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment with screed bed or bedding layer of cementmortar 1:6in 15 mm thick for laying floor finishes complete all as specified and as directed. |
| 57 | Supply and fixing in replacement ofLED luminaire chandelier crystal ceiling lights decorative glass pendent hight 2 feet suitable with 5 x 7.5 W LED lamp with mild steel albaster glass shade finish complete all as specified and as directed.Make: Havells Item code LHFHACCATB1K040 / Jaquar and equivalent |
| 58 | Supply and fix Water Mist Fan 26 inch dia Domestic Big Spray Mist Fan 6.5 Ft130 Degre Oscillating fan 45 ltr tank capacity 3 blade complete all as specified & directed. Make: Eurokart/ Usha/Havai |
| 59 | Taking down carefully copper/ Aluminum point wiring (light, fan socket or power) complete incl. (fitting such as switches, ceiling roses, pendants, regulators, sockets, boards, light fittings etc), removing materials and making good disturbed surfaces of walls, floors etc, complete all as specified and directed |
| 60 | M & L for point wiringwith FRLS insulated unsheathed 1100 volt grade multi strandedCopper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core FRLS insulated 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly terminated into PVC modular box of required sizeforone light point or one fan point controlled by one, one way switch on modular white cover plate with frame of required size (modular white cover plate with frame measured saperately) for mounting of switch complete all as specified and directed.(i) For One light /Fan Fan point controlled by one switch 6/5 Amp. |
| 61 | One 3 pin 6/5 Amp socket outlet controlled by one switch on indep board. |
| 62 | One 3 pin 6/5 Amp socket outlet controlled by one switch on same board. |
| 63 | M&L for point wiringfor Power point contolled by one 15 Amp switch independent with PVC insulated and unsheathed multistranded FRLS single core 4 Sqmm (nominalarea) cable using approved colour code as per IS drawing in and incl heavy duty PVC casing caping and its fittings, ISI markedincluding providingPVC modular box of required sizeforpower point controlled by one way switch on modular white cover plate with frame of required size (modular white cover plate with frame measured saperately) for mounting of Switch Socket complete alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cableof size 4 Sqmm as continous earth wire connected to common earth and earth dolly complete all as specified and as directed |
| 64 | Supply and fix modular Switchsingle pole, one way 5 Amp complete all as specified and directed. |
| 65 | Supply and fix modular Switchsingle pole, one way 15 Amp complete all as specified and directed. |
| 66 | M & L for concealed sub main wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including heavy duty PVC conduitsize with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces all as specified and directed. Note: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. |
| 67 | M&L Sub main wiring usingtwo runs of FRLSH grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 4.0 Sqmm and one run of 4.0 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and includingPVC casing caping / canduit complete all as specified and directed.Note :Two runs of 4.0 Sqmm copper wire,one run of 4.0 Sqmm wire & one run PVC casing caping shall be measured as one unit. |
| 68 | M&L Sub main wiring usingtwo runs of FRLSH grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 6.0 Sqmm and one run of 6.0 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including 25x12 mm size PVC casing caping complete all as specified and directed. (For TPN DB to SPN DB)Note :Two runs of 6.0 Sqmm copper wire,one run of 6.0 Sqmm wire & one run PVC casing caping shall be measured as one unit. |
| 69 | Supply and fix modular Socket 5 Amps, 230 volts, complete all as specified and as directed. |
| 70 | Supply and fix modular socket, 16 amps, complete all as specified and directed. |
| 71 | Supply and fix modular fan regulator complete all as specified and directed. |
| 72 | S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed. |
| 73 | S&F modular white cover plate with frame of 3 module complete all as specified and as directed. |
| 74 | S&F modular white cover plate with frame of 6 module complete all as specified and as directed. |
| 75 | S&F modular white cover plate with frame of 8 module complete all as specified and as directed. |
| 76 | S&F modular Metal flush box of 3 module complete all as specified and as directed. |
| 77 | S&F modular Metal flush box of 6 / 8 module complete all as specified and as directed. |
| 78 | Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 79 | Supply and fixing LED lights fitting 1x 10 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed |
| 80 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed |
| 81 | Supply and fixing LED luminaire Decorative wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 2 x 7.5 W LED lamp with nikel finish complete all as specified and as directed. Make: Havells item Code LHFOAHC2TZ1K040 equivalent in Jaquar |
| 82 | Dismenteling and servicing ofmetal body wall mounted fan / Ceiling of size any sweep sweep after removing and fix it at orginal position complete all as specified and as directed |
| 83 | Supply and fixing of sheet metal encloser box including Plug and socket with 20 Amps MCB (SP) complete all as specified. |
| 84 | S&F MCB DB CRCA sheet powder coated vertical type TPN 8 way double door factory made suitable for incorporating MCB as out going and MCCBs as incomingcomplete all as specified and as directed. |
| 85 | Supply and fix sheet metal enclosure MCB DB 8 waysingle pole with neutral for 240 V, fixed flushed on walls including necessary wall cuttingand making good disturbed surfaces and blanking plate as per requirementcomplete all as specified and directed |
| 86 | S&F MCCB 4P, AC, 415 volts IP-43 of 63 Amps capacityand making connections incl taking down unsv one complete all as specified & directed. |
| 87 | S&F miniature circuit breaker (MCBs) SPN , 240 Volt, 6-32 Amps, \"C\" series,10 KA breaking capacity, complete all as specified and directed |
| 88 | S&F MCB, SP, AC, 240 volts IP-43 of 05 to 32 Amps capacity \"C\" series and making connections incl taking down unsv one complete all as specified & directed. |
| 89 | S&F Test point terminal block made of gum metal or phosphorus bronze 75x75x25 mm drilled and screwed including 3 Nos 8 mm long hexagonal Head screw complete all as specified and directed. |
| 90 | M&L for Earthing complete with galvanized steel earth plate electrode 600 x600 x 6 mm, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the of plate not less than 1.5m below ground level connected to galvanized earth wire 4 mm by means of bolt, nut, check nut and washer of galvanized iron or steel earthing lead to be protected by galvanized iron pipe of 40 mm bore light grade and other end connected to earthing test point or main controlling switch as directed including providing funnel with 20 mm bore galvanized iron pipe medium grade for watering wire mess, charcoal or coke and common salt in alternative layers of 15 cm (compacted thickness) all around the earth electrode, concrete earth pit in PCC(1:3:6) type CI, 50mm thick precast RCC (1:2:4) type B1cover slab reinforced with 8mm dia TMT bar @ 15cm C/C both ways and suitable handle made out of 10mm dia , including necessary excavation and earth work, returning filling and disposal of surplus soil to a distance n. exc 50m and testing on completion complete all as shown in electrical plate No 3 SSR Part-I and as directed |
| 91 | M & L for point wiring with PVC insulated and unsheathed multistranded FRLS insulated unsheathed 1100 volt grade multi strandedCopper conductor cable of size 1.5 sqmm drawn in and including PVC concealed conduitof required size with all fittings and accessories alongwith one single core FRLS insulated 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly terminated into MS modular pressed steel box / PVC modular box of required size flushed in wall or on surface on faulse wall for light or Fan point controlled by one, one way switch 6/5 amp on modular white cover plate with frame of required size (modular pressed steel box, modular white cover plate with frame measured saperately) for mounting of switch complete all as specified and directed |
| 92 | M&L for 3 pin 6 Amp socket outlet point wiring on independent board with PVC insulated and unsheathed multistranded FRLS insulated unsheathed 1100 volt grade multi stranded Copper conductor cable of size 1.5 sqmm drawn in and including PVC concealed conduitof required size with all fittings and accessories alongwith one single core FRLS insulated 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly terminated into MS modular pressed steel box / PVC modular box of required size flushed in wall or on surface on faulse wall controlled by one switch 6 amp on modular white cover plate with frame of required size (modular pressed steel box, modular white cover plate with frame measured saperately) for mounting of switch socket complete all as specified and directed |
| 93 | M&L for 16 Amp socket outlet point wiring on independent board with PVC insulated and unsheathed multistranded FRLS insulated unsheathed 1100 volt grade multi stranded Copper conductor cable of size 4 sqmm drawn in and including PVC concealed conduitof required size with all fittings and accessories alongwith one single core FRLS insulated 1100 volt grade multi stranded FRLS Copper conductor cable of size 4 sqmm as earth lead and connected to earth dolly terminated into MS modular pressed steel box / PVC modular box of required size flushed in wall or on surface on faulse wall controlled by one switch 16 amp on modular white cover plate with frame of required size (modular pressed steel box, modular white cover plate with frame measured saperately) for mounting of switch socket complete all as specified and directed |
| 94 | M & L for concealed sub main wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including heavy duty PVC conduitsize with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces all as specified and directed. Note: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. |
| 95 | Supply and fixing LED luminaire 600 mm x 600 mm,40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 96 | Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and directed. |
| 97 | S&F MCB DB CRCA sheet powder coated vertical type SPN 8 way single door factory made suitable for incorporating MCB as out going and incomingalong with blank plate complete all as specified and as directed. (Note : MCB and DB should be of same make) |
| 98 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating with ISEER as per latest Ministery of Power notificationdt 10 Nov 2023 of coolingcapacity 6000 K Cal per hour (1.5 TR ) complete all as specified and directed.Make: LG / Bluestar / Daiken |
| 99 | Material and labour forrandering with 15 mm on fair face of brick work with cement mortar 1:4, having platform of size 0.8 x 0.3 x 0.45 (LxBxH) mtr for keeping outdoor unit of split AC complete all as specified and directed. |
| 100 | Supply and fix 5.0 KVA wall/floor mounted type Electronic Voltage stabilizer for automatic operation, single phase naturally air colled indoor type & designed for input variation between 120 V to 280V with output voltage stabilized at 230 V with accuracy of (+/-) 2.5% complete all as specified and as directed.Make: Bluestar Model No VS515DTA-GT / V Guard / Microtech |
| 101 | Copper tube (extra if required) for fixing of split Air conditioning of size 1/2 inch with insulating material all as specified and directed |
| 102 | Copper tube (extra if required) for fixing of split Air conditioning of size 1/4 inch with insulating material all as specified and directed |
| 103 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core. |
| 104 | Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 m depth and getting out in soft /loose/dense/hard soil complete all as directed. |
| 105 | Supply and spreading dry coarse sand in trenches as in sand cushioning for cable protection spread to uniform 23 cm thick and punch down gently to 18 cm after laying cable in trenches complete all as specified and directed. (Note: Compacted thickness shall be measured and paid) |
| 106 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm all specified and directed |
| 107 | Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and as directed. |
| 108 | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed |
| 109 | Supply and fixing of MCCB 4 pole100 Amps ,50 HZ of breaking capacity 25 KA with electro magnetic releaseas complete.Make: L&T / Havells / Legrand |
| 110 | Dismantling structural steel work in cluding doors, gates but excluding framed truss etc. all as specified and directed. |
| 111 | Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. |
| 112 | Demolition of Concrete of any description and in any position not otherwise specifically provided for |
| 113 | M&L for Cement concrete in foundations, filling and mass concrete Type B2 1:2:4, 40mm graded aggregate all as directed and specified |
| 114 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions |
| 115 | M&L for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as directed and specified. |
| 116 | All as per Item No.7 here in before but 5mm dua and over upto 10mm dia in stirrups spcers and binders all as directed and specified. |
| 117 | M&L for brick work with sub class ‘B’ (modular size bricks) straight or curved on plan exc 6 m mean radius, built in cm 1:4 complete all as specified and directed. |
| 118 | Materials and labour for 15 mm thick rendering in cement mortar (1:4) on brick/concrete surface finished even and fair without using extra cement , complete all as specified and as directed. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender