| Sl. No. | Item Description |
| 1 | CIVIL WORK -Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete. |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 metre) By Mechanical Means |
| 3 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material up to a distance of 50 metres beyond the building are a and stacking as directed, including dewatering, preparing the bed for the foundation and necessary backfilling with available earth/murum, ramming, watering including shoring and strutting etc. complete.(Lift from 1.5 metre to 3.0 metre) By Mechanical Means |
| 4 | Excavation for foundation in Hard-rock by blasting including trimillimetre ing and leveling the bedby chiselling where necessary and removing the excavated material and stacking it in measurable heaps within adistance of 50 metres from the building area including dewatering and backfilling with available earth/murum watering, ramming etc.complete. (Lift from 3.0 metre to3.5 metre) By Mechanical Means For building works for the excavation beyond 3.0 metre depth, following increase in basic rate of an item shall be made:- 3.0 metre to 4.50 metre depth add 20 % |
| 5 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper. |
| 6 | Providing soling using 80 millimetresize trap metal in 15centimetre layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. |
| 7 | Filling in plinth and floors with approved excavated material in 15centimetreto 20centimetreLayers including watering and compacting etc. complete. |
| 8 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15centimetre to 20centimetre including watering and compaction etc. complete. |
| 9 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricks incement mortar1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. |
| 10 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer)etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI)Grade) |
| 11 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trapmetal for Reinforced cement concretework in foundations like raft, strip foundations, grillage and footings of Reinforced cement concretecolumns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer)etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI)Grade) |
| 12 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trapmetal for Reinforced cement concretecolumns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer)etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI)GradeStilt Floor |
| 13 | Ground Floor |
| 14 | First Floor |
| 15 | Terrace Floor |
| 16 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap metal for Reinforced cement concretebeams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer)etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI)Grade) Stilt Floor |
| 17 | Ground Floor |
| 18 | First Floor |
| 19 | Terrace Floor |
| 20 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap metal for Reinforced cement concretepardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer)etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI)Grade) Stilt Floor |
| 21 | Ground Floor |
| 22 | First Floor |
| 23 | Terrace Floor |
| 24 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trapmetal for Reinforced cement concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer)etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI)Grade) Stilt Floor |
| 25 | Ground Floor |
| 26 | First Floor |
| 27 | Terrace Floor |
| 28 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap metal for Reinforced cement concreteslabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer)etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI)Grade) Stilt Floor |
| 29 | Ground Floor |
| 30 | First Floor |
| 31 | Terrace Floor |
| 32 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trapmetal for Reinforced cement concreteWaist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface withcement mortar1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based Programmable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer)etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI)Grade) Stilt Floor |
| 33 | Ground Floor |
| 34 | First Floor |
| 35 | Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced cement concretechajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller (PLC)with Supervisory Control And Data Acquisition (SCADA) enabled ConcreteBatchMixPlant(Panmixer)etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI)Grade) (Stilt Floor )Stilt Floor |
| 36 | Ground Floor |
| 37 | First Floor |
| 38 | Terrace Floor |
| 39 | Providing and fixing in positionThermo Mechanically Treated (TMT)- FE - 500 bar reinforcement of various diameters for Reinforced cement concretepile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Stilt Floor |
| 40 | Ground Floor |
| 41 | First Floor |
| 42 | Terrace Floor |
| 43 | Providing and fixing during laying in Reinforced cement concreteSlab rectangular 2 millimetrethick Mild steelsheet fan hook box of size 180x100 millimetrewith required depth with holes or notches as required, bottom and top sides of 1.6 millimetreMild steelsheet fixed with 3.5 millimetrediameterround headed screws together with 12 millimetrediameterMild steelbar bent to shape with hooked ends for fan hook and painting to exposed surfaceStilt Floor |
| 44 | Ground Floor |
| 45 | First Floor |
| 46 | Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225)millimetrein extra fine jointing mortar of fixoblock of in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete. Stilt Floor |
| 47 | Ground Floor |
| 48 | First Floor |
| 49 | Terrace Floor |
| 50 | Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625x 240x100)millimetrein extra fine jointing mortar of fixoblock of in half brick thick wall including 2 hoop iron strips 25millimetrex 1.6millimetreat every third course,properly bend and bonded at ends scaffolding racking out joints and watering complete. Stilt Floor |
| 51 | Ground Floor |
| 52 | First Floor |
| 53 | Providing internal cement plaster 20 millimetrethick in Single coats in cement mortar 1:4 with out neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete (Stilt Floor)Stilt Floor |
| 54 | Ground Floor |
| 55 | First Floor |
| 56 | Terrace Floor |
| 57 | Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.Stilt Floor |
| 58 | Ground Floor |
| 59 | First Floor |
| 60 | Terrace Floor |
| 61 | Providing internal cement plaster 12 millimetrethickin single coat incement mortar 1:4 with out neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Stilt Floor |
| 62 | Ground Floor |
| 63 | First Floor |
| 64 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetrethick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetrethick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Stilt Floor |
| 65 | Ground Floor |
| 66 | First Floor |
| 67 | Terrace Floor |
| 68 | Providing and fixing chicken mesh of 22 gauge, with about 30centimetre width at the junction of Reinforced cement concretemembers and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Stilt Floor |
| 69 | Ground Floor |
| 70 | First Floor |
| 71 | Terrace Floor |
| 72 | Water proofing treatment to new terrace by using chlorinated paraffinated talcum polyurethane (CPTP)elastomeric membrane as approved by Engineer incharge, followed by average 112mm thick brick bat coba covered with 40mm thick IPS. The procedure includes filling of cracks on the RCC slab with high performance polyurethane (liquid applied)membrane. Clean the entire surface thoroughly and over this prepared surface, apply a primer coat of high performancepolyurethane (liquid applied)membrane as approved by Engineer incharge. Apply the primer by roller. Extend the coating to parapet walls including the top of parapet. Allow the primer coat to set for 24 hrs. After the primer coat is set, apply two coats of chlorinated paraffinated talcum polyurethane (CPTP)elastomeric membrane as approved by Engineer incharge on surface. Ensure that pinholes are touched up properly. While the second coat of high performance polyurethane (liquid applied)membrane is wet and tacky, sprinkle coarses and over the surface to make it rough and provide mechanical key for further treatment. Provide and lay average 15mm thk protective coat of CM in 1:4 over the surface and allow to set and cure. Provide and lay 112mm thk BB coba in average thickness in cement mortar 1:5 with one pouch of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents-which is based on special cements, aldehyde based polymers, shrinkage compensating agents and selected sands having high abrasion resistance as approved by Engineer incharge per 50 Kg bag of cement and finishing with 40mm thick IP Slayer in M-20 CC by mixing one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents per 50 Kg bag of cement, including all leads, lift sand laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion atthe junction of parapet and work up to a height of 300 mm or as directed and including finishing the to player of water proofing treatment with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. The liquid membrane should have a track record of at least 4 year sin India & Gulf region and have at least an 4 year track record in PWD. Single Component, Liquid Applied, chlorinated paraffinated talcum polyurethane (CPTP)elastomeric membrane should have following minimum properties :1)Water Permeability (DIN 1048) : Nil as per DIN 1048 @ 7 bar of Hydrostatic Pressure. 2) Mo (Terrace Floor) |
| 73 | Providing water proof bedding for flooring of Bath and Water closet25 millimetrethick incement mortar1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.Stilt Floor |
| 74 | Ground Floor |
| 75 | First Floor |
| 76 | Water proofing Treatment to plastered surface of toiletandbath room walls minimum up to 90centimetre (Dado)by using 2-(methoxy carbonyl )-1-propene-Butyl-2 propenoate (MPBP) based polymeric water proofing solution as approved by Engineer in charge. Clean the entire surface thoroughly and over this prepared surface, apply three coats of 2-(methoxy carbonyl)-1-propene-Butyl-2 propenoate (MPBP)based polymeric water proofing solution as approved by Engineer incharge.While the 3 coat is wet broad cast sand on the surface. Provide 20millimetrethick cement plaster incentimetre 1:3 with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers ,shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement including all lead, lifts, curing etc complete. Acrylic Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties :1. Elongation % (ASTM D412-2016): @ 100%2. Tensile Strength N/millimetre 2 (ASTM D412-2016): 3.33. Specific Gravity: 1.02 ± 0.024. Total Solids (ASTM D1644-2012): 43.985. Hardness Shore A (ASTM D2240-2015): 82It shall be applied as per manufacturer’s specification. Stilt Floor |
| 77 | Ground Floor |
| 78 | First Floor |
| 79 | Providing and fixing 20 to 25 millimetrethick rough shahabad box type water proofing treatment to vertical out side faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 millimetrebetween rough shahabad and Reinforced cement concretewalls with cement grout mixed with water proofing liquid Algae proof or other a like with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 millimetreand sloping coping over top most tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/-with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) (Stilt Floor) |
| 80 | ProvidingandLaying full body vitrified tile / slabs which are manufactured by using excusive technology continua+ ( Digital Day Decoration Digital system) having Size 3000 x 800 x 15 millimetrethick full body matt finish ( standard as per 13006:2018 EN 14411 Gr.Bla.for Glossiness 90%with nano technology except hydraulic acidandits Compound ), as per the finishesanddesigns using colored clay powderandclay flex throughout the body Includingall material Transportation laying/fixing and Filling the joint\"s with colored Pigment\"s on the base of bedcement mortar1:3 as per Design Pattern / Details, cleaning washing etc. complete. ( simpolo or equivalent ) Stilt Floor |
| 81 | Ground Floor |
| 82 | First Floor |
| 83 | Stamp Concrete of 100millimetreThickness - Providing and Layingin-situ M30 Grade unreinforced plain cement stamp concrete of 100millimetrethickness pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (natural sand/VSI grade finely washed crushed sand)Confirming to IS383, as permixed in a batching and mixing plant/non tilting mixer and weigh batcher as per approved mixde sign, admixtures, transporting to site in nagpur city with lead up to 20 KM(on Inner Ring Road from Avasti nagar to wadi), spreading, laying with approved make pover, compacted and finished in a continous operation, finishing to lines and grades Also Providing, Placing and applying stamp powder which is light fast UV resistant pigment with appropriate chemical compounds of desired colour on base concrete after excess bleed water has evaporated using dry shake method @ 5 kg per sqm. Including texturing, and covering with plastic sheet (min 200 micron thickness)and also applying two coats of UV-stable, 30% solids clear sealer @150 to 250 gms per sqm using surface roller and protecting from falling dust, dirt and curring by curring compound/by providing cement vatain cement Mortor1:8 @0.6 mx 0.6m center to center, admeasuring 80 millimetreat bottom and 40 millimetreat top with depth of 75 millimetreand maintaining the same through out curing period by any other method approved by Engineer-incharge or Land scape architectetc. complete. (prior approval of superinteding Engineer will be necessary ) (Stilt Floor) |
| 84 | Providing and laying vitrified mirror / glossy finish tiles having size 590 millimetreto 605 millimetrex 590 millimetreto 605 millimetreof 8 to 10 millimetrethickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Stilt Floor |
| 85 | Ground Floor |
| 86 | First Floor |
| 87 | Providing and laying vitrified matt fininsh tiles having size 590 millimetreto 605 millimetrex605 millimetreof 8 to 10 millimetrethickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.Stilt Floor |
| 88 | Ground Floor |
| 89 | First Floor |
| 90 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Stilt Floor |
| 91 | Ground Floor |
| 92 | First Floor |
| 93 | Terrace Floor |
| 94 | Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with miner alturpentine with brush 8 to10% and oil 15 to 20%with roller and all owing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water all owing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applying wall primer with brush with mineralturpentine 8 to10% and oil 15 to 20%with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat withb rush/rubber/ spray with mineralturpentine 7 to 9% and Oil with roller 19 to 21%After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineralturpentine 7 to9% with brush and Oil with roller 19 to 21%after all owing dry for the period of 6 to 8 hours activity.Stilt Floor |
| 95 | Ground Floor |
| 96 | First Floor |
| 97 | Terrace Floor |
| 98 | Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.Stilt Floor |
| 99 | Ground Floor |
| 100 | First Floor |
| 101 | Terrace Floor |
| 102 | Providing and applying Texture plaster with finishing with texture material of approved makein 3 to 4 millimeter thickness on previously plasteredsurface, including Plaster Groove 6 millimetrethickness or Tape Grooves 35 to 45 millimetrethickness or as required, in all position including preparing the surface, scaffolding etc. complete.Stilt Floor |
| 103 | Ground Floor |
| 104 | First Floor |
| 105 | Terrace Floor |
| 106 | Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturerrcommendedapplicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Stilt Floor |
| 107 | Ground Floor |
| 108 | First Floor |
| 109 | Terrace Floor |
| 110 | Providingand Fixing mat finish stainless steel (of 302 grade) railing with top pipe of 50 millimetrediameterand vertical pipe of 38 millimetredia at 0.60 m c/c or as required and horizontal pipes of 25 millimetredia in three rows, all pipes of 2millimetrethick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75millimetredia above newel post of 75 millimetrediameter etc.complete.Stilt Floor |
| 111 | Ground Floor |
| 112 | First Floor |
| 113 | Providing and fixing 900millimetrehigh Stainless steel 304 Grade Stainless steel railing with 40millimetrediameter and 1.5millimetrethick at top, 40millimetrediameter and 1.5millimetrethick vertical supports spaced at 1.5m center to center and 8millimetrethick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete Stilt Floor |
| 114 | Ground Floor |
| 115 | First Floor |
| 116 | Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI)108 (with solar reflectanceandthermal emittance tested as per ASTM )C1549 and ASTMC1 371 respectively, VOC less than10cc/gm.The coating thicknes sand the methodology of application shall strctly as per manufacturer\"s specifition sand as approved by engineer incharge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge. (Terrace Floor) |
| 117 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetrethick for door frame/ dado/ window boxing etc. Oncement mortar1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. Stilt Floor |
| 118 | Ground Floor |
| 119 | First Floor |
| 120 | Providing and fixing frame with/without ventilator of size as specified with Country cut teakwood for door sand windows including chamfering, rounding ,rebating,ironholdfastof size 300millimetrex 40millimetrex 5millimetrewith oil painting, etc. complete. Stilt Floor |
| 121 | Ground Floor |
| 122 | First Floor |
| 123 | Terrace Floor |
| 124 | Providing and fixing of factory made uPVC Sliding window & door (WhiteColour)complete, comprising uPVC multi-chambered frame havingin-built uPVC roller trackontopand uPVC sash with wall thickness of 2.3mm (+-0.2mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BSEN 12608 and other standards asmentioned below: S.No.Name of the test Test Method Specified Parameter1TensileImpactStrengthISO8256-morethan700Kj/m22VicatSoftening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 \"P\" Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAllcornersofframeandsashwillbefusionwelded.Afterplacing5mmFloatAnnealedglassinthesash,uPVCglazingbead,interlock,EPDM/TPEgasket,brushshallbeprovidedincludingtouchlockandrollers&properdrainagesystemshallbeprovided.Window/Doorwillbefixedtothewallwith100mmlongand8mmdia.FastenersandcompleteinallrespectasperdirectionofEngineer-In-Charge.uPVCWindowandDoorProfilesarewarrantedforaperiodoften(10)yearsagainstnon-uniformdiscoloration,wrapping and rotting under general use. Stilt Floor |
| 125 | Ground Floor |
| 126 | First Floor |
| 127 | Terrace Floor |
| 128 | Providing and fixing 48millimetrethick both side VENEER door ( without glass ) made up of 18millimetrethick comillimetre ertial (ISI-303) plywood Frame covered with 12millimetrethick comillimetre ertial (ISI-303 ) plywood both side of the frame to get required thicknees as per architectual design and drawingpremium quality with grove, edges finish with 50 x 10 millimetreBTC lipping as per drawing is fitted bt BTC 22 x 10millimetremoulding including all materials brass screw, brass hinges (125 x 12millimetre ,) mortice lock, door stopper, antitermite treatment to plywood, two coats melamine pollish to moulding and lipping, labour charges as directed by engineer incharge etc complete.Stilt Floor |
| 129 | Ground Floor |
| 130 | First Floor |
| 131 | Providing and fixing full height veener partition (with Glass) 76millimetrethick made up of 18millimetrethick comillimetre ertial (ISI- 303) plywood 2x50millimetrewidth frame work at 0.60 x 0.60 meter center to center and both face covered with 12 millimetrethick comillimetre ertial (ISI- 303) ply treated with antitermite treatment and both side finish with 4millimetrethick natural wood veere (fitchess metallic bul veerner series) confirming to (ISI 1328) and finished with melamine polishing matt or glossy and 6.0millimetrethick glass as per architectural design and drawing including all material, hardware, labour, and as directed by engineer in charge etc. complete.Stilt Floor |
| 132 | First Floor |
| 133 | Providing and fixing of factory made uPVC Louver window (WhiteColour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2mm), dulyreinforced with 1.5 mm thick G.I . Section. uPVC window & door profile shall be made in India & shall conform to BSEN 12608 and other standards asmentioned below: S.No. Nameof the test Test Meth od Specifie Parameter 1 Tensile Impact StrengthI SO8256-morethan700Kj/m22 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 \"P\" Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength ENISO527Shallnotbe<30MPa. All corners off rame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism havin gon eleveror fixed louver bracket shall be fitted with the of 4mm Frosted Anneal edglass. Window will be fixed to th wall with 100 mm long and 8mm dia.Fastener sand complete in all respect as per direction of Engineer-In-Charge. u PVC Window and Door Profiles are warranted foraperiod of ten(10) years against non-uniform discoloration, wrapping and rotting under general use .a.Louver Window (BigSeries) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm. (Stilt Floor) Stilt Floor |
| 134 | Ground Floor |
| 135 | First Floor |
| 136 | Providing and fixing mild steel grill work for windows ventilators etc. 20 Kilogramme per square metre as per drawing including fixtures, necessary welding and painting with one coat so fanticorrosive paint and two coats of oil painting complete.Stilt Floor |
| 137 | Ground Floor |
| 138 | First Floor |
| 139 | Terrace Floor |
| 140 | Providing and fixing 48millimetrethick both side laminated door ( without glass ) made up of 18millimetrethick comillimetre ertial (ISI-303) plywood Frame covered with 12millimetrethick comillimetre ertial (ISI-303 ) plywood both side of the frame to get required thicknees as per architectual design and drawing with both side cover with 1.00millimetrethick laminate confirming to (ISI 2046 ) premium quality with grove, edges finish with 50 x 10 millimetreBTC lipping as per drawing is fitted bt BTC 22 x 10millimetremoulding including all materials brass screw, brass hinges (125 x 12millimetre ,) mortice lock, door stopper, antitermite treatment to plywood, two coats melamine pollish to moulding and lipping, labour charges as directed by engineer incharge etc complete.Stilt Floor |
| 141 | Ground Floor |
| 142 | First Floor |
| 143 | Terrace Floor |
| 144 | Solid Core Flush door Double leaf Providing and fixing factory made solid core flush door shutter sin double leaves 35 millimetrethick, decorative type of exterior grade, as per detailed drawings, conforming to I.S. : 2202–1966 (Revised)including approved face veneers on both sides ,without glazing and venetians including mat finish stainlesssteel fixture sand fastening , stopper sand finishing with french polishing etc.(Excluding doorf rame)(Sample to be got approved from Ex. Engineer before use) CommercialHard Wood shutter |
| 145 | Supplying,andfixing in position aluminium fins of 1000X50x25 millimetrewith special locking system designed by Elegance architerural productssupported by 38x38millimetreL-Angle with pre-punchated hole as per approved gap horizontal carriers both, having thickness of 1millimetreand a clear gap of 50millimetrebetween verical members as per pattern,choice of colour,finish, etc. as shown in approved drawing and as instructed by site Incharge. Rates shall be inclusive of supplyandfixing using 1millimetrethick L-clit of dim. 50millimetreX 50millimetreX 50millimetre andSS-screws), application of powder coating, cutting, making, fixing, transportation, loading, unloading, lifting, shifting, saftey precautions etc. all complete. Stilt Floor |
| 146 | Ground Floor |
| 147 | First Floor |
| 148 | Proving and fixing or brick cladding using flexstone bricks of approved colour shades size (size L - 230millimetre,H - 75millimetre,Thikness- 20 to 24 millimetre) and corner cladding bricks (size L - 230 +115 millimetre,H - 75millimetre,Thikness- 20 to 24 millimetre)with ponting joints. Flexstone brick is a eco friendly decorative concrete system, made with recycled raw material and cement use has a binder, with density more than 1800kg/m3 , hight compressive strength around 50mpa and abrasion resistant, exterior grade apply with polymer base cementious adhesive with good adhesion strength fast curing . brick shall be late accurately with 10millimetremortar between brick shall be laid using 10millimetretemplate joinery ang grout hight to be adjust as per natural variation in brick size to achive the natural cladding look. polymer modify cementious base adhesive to be applied as uniform scratch coat first and indivitual brick places to be fixed over heat. standered make adhesive to be used and no dilution of tilling adhesive by adding cement / sand should be done after cladding bricks joints to be pointed with the same tilling adhesive of approved colour , used for cladding the bricks. contractor to ensure the bricks are not stained with grout/ cement while fixing and ponting the adhesive must be allowed to settel for a day. after installation and cleaning protective transperant water based breathable PU sealer coat matt has as selected bt architect to be done over all with the help of brush in the final stage to make the brick repellent etc complete .Stilt Floor |
| 149 | Ground Floor |
| 150 | First Floor |
| 151 | Supplying and fixing of 6millimetrethick Exterior Compact Laminate or High Pressure Laminate of approved colour by approving authority with UV resistant Decorative colour paper on both side typically made out of multiplelayer sof craft paper sand then impregnated with the rmo setting phenolicresins, on top of it melamine treated barrier paper and decorative paper and wear layer on both the sides saturated with melamine resins and then covered with UV resistant acrylic resin layer which makes it extremely durable and weather resistant compressed together on extremely high pressure and hardened with electron be am curing to get the total desired thickness of 6millimetrematching European standard specification as per EN438-part 6,protected with 60 Micron protective peel-off film on both side which in no case leave any adhesive mark over the panel surface after it is peeled off. Fixing of the same to be done on a supporting frame of 50 millimetreX 5millimetreX 3 millimetrepowder coated aluminium box section to bespaced horizontally and vertically in 600 millimetreX 600 millimetregrid and fixed to building structure as per design through 50 millimetreX 50 millimetreX millimetre5millimetreMSangle bracket prefixed to masonry slab or columns with Hilti make anchor fastener along with all related hardware and fixtures.The panel should then be fixed on the Aluminium section with the help of pure polyester exterior grade colour coating rivets as per architectural drawings or as directed by Engineer-in-charge. Each panel should be riveted on substructure maintaining agap of 6millimetreon all the sides between each Panel for Aircirculation and expansion and contraction as per installation specifications provided by the manufacturer. The cost shall include all expenses related to storage, material handling, lifting, freight, labour, scaffolding etc as directed by Engineer-in-charge.Stilt Floor |
| 152 | Ground Floor |
| 153 | First Floor |
| 154 | Providing and fixing in position Gypsum board false ceiling with 12.5 millimetrethick Gypsum boards, screwed / fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimetremaximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab.The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from under side to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels . Additional intermediate channels should be fixed to straphangers for additional support to prevents trapping at every 1200 milimetre it em to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.Stilt Floor |
| 155 | Ground Floor |
| 156 | First Floor |
| 157 | Providing and fixing board displaying in formation, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc \",having rectangular shape of 1.80m x 1.20m size made up of 4millimetrealuminum composite panne lsheet with 0.5millimetreskin thickness one it her side bonded with white retro reflective sheeting of Class C (Type XI Micro prismatic grade sheeting)having pressure sensitive adhesive. Retro reflective sheeting with specified background, border and backsidere to reflective symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, on Mild steelangle of size 35 x 35 x 3millimetreframe with properly cross braced Mild steelangles of size 35millimetrex 35millimetrex 3millimetreduly painted including Two Mild steelangle iron posts of size 65millimetrex 65millimetrex 6millimetre , 3.65 ml on g painted with alternate black and white bands of 25cm width including all fixture set c. and fixing the boards in 1:4:8 concrete block of size 60cm x60cm x75cm including, excavation, refilling, transportation, and labouretc complete. Class_C_ (Type XI Microprismatic grade sheeting ))shall have10 years written warranty from the manufacturer including the Digitally Printed are as with approved printing technology with sheeting manufacturer approved in k sand laminated withUVover lay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. (Terrace Floor) |
| 158 | Providing and laying damp proof course 50 millimetrethick in M-20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. Stilt Floor |
| 159 | Ground Floor |
| 160 | First Floor |
| 161 | Terrace Floor |
| 162 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material up to a distance of 50 metres beyond the building are a and stacking as directed, including dewatering, preparing the bed for the foundation and necessary backfilling with available earth/murum, ramming, watering including shoring and strutting etc. complete.(Lift from 3 metre 3.5 mete) By Mechanical Means |
| 163 | Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimetrex 450 millimetresize as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimetrethick supports with kadappah top 35 to 40 millimetrethick and polished granite 16 to 20 millimetretop with side strips of granite at front and both sides of platform raised with two vertical granite supports 15centimetre height and top granite of 75 x 40centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 metre and height is 0.75 metre) |
| 164 | Alluminium foldable ladder for store ProvidingandFixing Foldable Alluminum Ladder 1500 millimetre . Ht. |
| 165 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) millimetreAggregate) |
| 166 | Providing and fixing heavy duty inter locking concrete greypaving blocks of 80 millimetrethickness of having a strength of 300 Kilogram /Sq.centimetre .of approved quality and shape ona bed of crushed sand of 25to30 millimetrethick including skirting joints and cleaning etc. complete. |
| 167 | Providing and casting in situ or precast tapering Reinforced cement concreteM-20 Barrier type Kerb without gutter ( as per IRC 86 1983) embedded 125millimetrebelow ground level over M-10 PCC finished neatly withcement mortar1:2, setting the same incement mortar1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant |
| 168 | Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or |
| 169 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening / binding material to fill the interstices of coarse aggregate, watering and compacting with Vibratory roller to the required density. - By Mechanical Means - Grading II Using Screening type-B (11.2 milimetre Aggregate) |
| 170 | Providing and laying in situ cement concrete M-30 with tremix treatment for 200 millimetrethickness for flooring with groove cutting of 4millimetrewide and 20millimetredeep with necessary refilling with bitumen etc. complete excetra complete. |
| 171 | Providing first class Burnt Brick masonry with conventional /I.S. type bricks in cement mortar 1:6 in plinth including bailing out water manually, striking joints on unexposed faces, pointing with cement mortar 1:3 on exposed face and watering etc. Complete. |
| 172 | Free Standing Table @ 1200L x600Dx750HT Providing and fixing Table of Size1200 x600x 750millimetre .Top:made from 25 millimetrePrelaminated Particle board.All edges are covered by 2millimetre .Thk.Poly vinyl chlorideedge bands glued by hot melt glue applied by auto edge banding machine. Legs:CShape made from CRCA Sheet with PowderCoat finish.Mode sty panel:Made from 18 millimetreboth side pre laminated particle boards. All edges are covered by 0.8millimetrePoly vinyl chlorideedge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY (WITHOUT MOUSE TRAY):-Metal Powder Coated-Black Color,CPU TROLLEY:-Metal Powder Coated-Black Color,3 DRAWER PEDESTAL UNIT having over all size 392L x450D x680Ht.millimetre .with central lock and key.Drawers and body are complete metal with powder coat finish, facia in 18 millimetreprelaminated particle board, SSR 2020-21 Item No. 51.28 Page No. 346.Stilt Floor |
| 173 | Ground Floor |
| 174 | First Floor |
| 175 | Tea Table 900millimetreX 750millimetreX 450millimetrefor Mild steelante chamber Providing And Fixing Of Tea Table 900millimetreX 750millimetreX 450millimetreWith 12millimetreThick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18millimetreThickWaterproofing Ply. The Outer Laces To Be Finished With High Quality 4 millimetreThik Veneer Or 1 millimetreThik Mica Etc.)Stilt Floor |
| 176 | Ground Floor |
| 177 | First Floor |
| 178 | PROVIDINGandFIXING LAMINATED BED SIDE DRAWER UNIT HAVING SIZE OF 0.60 x 0.45 x 0.325 METER MADE UP OF 18 millimetre COMMERTIOL(ISI-303) Ply and drawer frame and bottam made up of 12millimetreplywood and outter side finish with 1.00millimetrethick LAMINATE confirming to (ISI 2046)andInternal Surface Finish With 0.8millimetreThick Laminate and BTC lipping, melament polish two moulding, lipping antitermite treatment to plywood , and as directed by engineer In charge etc complete.Stilt Floor |
| 179 | Ground Floor |
| 180 | First Floor |
| 181 | CHAIR- ProvidingandArrangemnt of MidBack ,ECOCTS Mechanism,Fixed Armrest, Gas lift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric UpholsteryStilt Floor |
| 182 | Ground Floor |
| 183 | First Floor |
| 184 | Providing and supplying Single seater sofa of overall size 750 x 750 x 750 millimetreheight made out of 75x38millimetre(unfinished size )Chromium plated Teak woodsections frame, 6 millimetreply generally |confirming to I.S. 303 for necessary covering from backandarm rests. The seat shall be of 125millimetreand back shalli be of 100millimetrethick duly covered with tapestry fabric/conpositer leather (not less than Rs.350/- /Rmt) including necessary hardware, naval,jute cloth, casement, springs etc.complete. All exposed wooden surface shall be melamine polished and antitermite treatment to plywood and wood work with ten years guarantee bond etc. including all leadsandlift etc. complete. and as directed by Engineer incharge. Ground Floor |
| 185 | First Floor |
| 186 | Providing and fixing DOUBBLE BED LAMINATED having size 2.00 * 2.00* 0.34 made up ofCOMMERTIOL(ISI-303) Ply made up 18 millimetrethick Plywood for frame work as per architectural designanddrawing and finish with 1.00millimetrethick LAMINATE confirming to (ISI 2046) and Internal Srface finish with 0.8millimetreThick Lamiante, including BTC lipping, melament polish two moulding, lipping antitermite treatment to plywood, and as directed by engineer In charge etc complete (Stilt Floor)Stilt Floor |
| 187 | Ground Floor |
| 188 | First Floor |
| 189 | TV CABINET Providing and fixing in position TV CABINET 2.50 X 0.30 X 0. 600 meter size in the Room, wooden structure as per detan|drawing with 18 millimetrethick Commercialplywood Conforming IS 303:1989 on surface Also granite top table ,all the edges to be Finished with best quality teakwood bidding patti of size 1/2 inch. Allsurfaces to be finished with Telephone Black granite as per drawing . Adhesives used shall be low-voc compliant. Including applying mealamine polish to all wood work, Including handles 150millimetre , Iron hinges, slidding strip channels, magnetic ballcatcher, concealed lock, nailsandscrew and installation shall be in true lineandlevelcomplete with necessary provision for electrical switchesandwiringit any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge. (Stilt Floor)Stilt Floor |
| 190 | Ground Floor |
| 191 | First Floor |
| 192 | Providing and Fixing Rollar Blinds AMI Make or approved makeandshade of 38millimetreround Aluminium channel with Blackout fabricandtelting with chain (Ball) system with all necessary fixtures and fitting etc. complete.Stilt Floor |
| 193 | Ground Floor |
| 194 | First Floor |
| 195 | DINNING TABLE(2.10 X 1.10 X0.750 M)Providing andfixing in position DINNING TABLE 2.10 X 1.10X0.750 meter size in the Room, wooden structure as per detail drawing with 18 millimetrethick Commercialplywood Conforming IS 303:1989 on surface Also granite top on luggageandsurvicetable ,allthe edges to be finished with best quality teakwood bidding patti of size 1/2inch. All surfaces to be finished with Telephone Black Granite as per drawing . Adhesives usedshall below-VOC compliant. Including applying mealamine polish to all wood work, Including nailsandscrew and installation shall be in true lineandlevel complete witn necessary provision for electrical switchesandwiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge. (Ground Floor) |
| 196 | Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete bodyandshutter made in 0.8 millimetrethickandTop in 2 millimetrethick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing. Stilt Floor |
| 197 | Ground Floor |
| 198 | First Floor |
| 199 | Providing and fixing in position customised \"Reception Counter\" having size 3.2 x 0.6 x 0.75 meter made to measurement as per design drawing. Carcass shall be made out of 18millimetreCommercialplywood conforming IS 303:1989, All exposed edges to be finished with best quality teakwood patti of size 1/2 inch. All inner surfaces to be finished with white laminate lining.andveneer used for outer faces, Top 1.8 X 0.450 meterandFrount 1.8 x 1.2 meter finish with 6 millimetrethick white corien usedandAdhesives used shall be low-VOC compliant as per GRIHA.Including handles 150millimetre , Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nailsandscrew and installation shall be in true lineandlevel complete with necessary provision for electrical switchesandwiring if any. The rate shall be inclusive of all labour, material, scaffolding, transportation, including all leads, lifts at all levels and as directed by Engineer Incharge. (Stilt Floor) |
| 200 | Providing and suppying Three seater sofa of overall size 1950 x 750 x 750 millimetreheight made out lof 75x38millimetre(unfinished size )Chromium plated T.W. sections frame, 6millimetreply generally confirming to I.S. |303 for necessary covering from backandarm rests. The seat shallbe of 125millimetre and back shall be of 100millimetrethick duly covered with tapestry fabric / conpositer leather ( not less than Rs.350/- /Rrmt) and foam of 60 density including necessary hardware , naval, jute cloth |casement, springs etc.complete. All exposed wooden surface shall be melamine polished and antitermite treatment to plywood and wood work with ten years guarantee bond etc. including all leadsandlift etc.complete. and as directed by Engineer incharge. (Ground Floor)Stilt Floor |
| 201 | First Floor |
| 202 | Providing and fixing storage units of full height upto 2.4 metreheight/ as per drwng. They shall consist of 18millimetre thick Commercialply top, sides, bottom, shelves and shuttersand6millimetrethk Commercialply for back.The bottom of the storages shall be at 75millimetrefrom FFL. The shutter with box type (W) higes of approved makeandteak lipping finished with melamine with approvedlaminate on all the shutter edges. Division of the shutters shall be made equally according to the length of the storages( as approved by architect). All the external surfaces shall be finished with 1.5 millimetre thick Laminate of approved make. 18millimetre thick CommercialPly shelves at 0.45 m interval ( approximately / divided equally) shall be provided. All inner surfaces shall be finished with 1.0 millimetre thick laminate including the shutters. Rate shall be inclusive of all necessary approved fittings like box (W) hinges, locks, 150millimetrelong SS brushed finish handles,tower bolts, magnet and any necessary hardware items. Note.:as per detailed drawing given by Architect etc. complete. Stilt Floor |
| 203 | Ground Floor |
| 204 | First Floor |
| 205 | ProvidingandFixing 450x 900 millimetreSize Supirier type Mirror 6.00 millimetreThick MODI GUARD OR ASHIFLOT Fixing on the Wall with 25millimetreS.S Stud With Necessary Labour Etc Completed.Stilt Floor |
| 206 | Ground Floor |
| 207 | First Floor |
| 208 | Providing and fixing SINGLE BED LAMINATED having size 1.20 * 2.00 * 0.34 made up ofCOMMERTIOL(ISI-303) Ply made up 18 millimetrethick Plywood for frame work as per architectural designanddrawing and finish with 1.00millimetrethick LAMINATE Confirming to (ISI 2046) Internal Surface finish with 0.8millimetreThick Laminate and BTC lipping, melament polish two moulding, lipping antitermite treatment to plywood, and as directed by engineer In charge etc complete.Stilt Floor |
| 209 | Ground Floor |
| 210 | First Floor |
| 211 | Providing and fixing designer wall paper made up of Poly vinyl chlorideonwall, Ceilling or on Plywood Partition including wall paper adhasive and skilled labour etc. |complete as directed by Engineer in chargeStilt Floor |
| 212 | Ground Floor |
| 213 | First Floor |
| 214 | Providing and supplying on site visitors chair with round 2 millimetre . thk pipe frame with chrome finish with reinforced pipe inserts having moulded seat and back with nylon back cover with PP armrest hanging back fabric etc. complete.(B1019 INDIAN) VISTER CHIAR TYPE -1 |
| 215 | Bed Side Table @ 400LX 400DX 415H Providing and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is made up of 18millimetrethick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2millimetrethick Poly vinyl chlorideedge Banding. The bed side table has one drawer and one shelf. The shelf is made of 18millimetrethick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2millimetrethick Poly vinyl chlorideedge Banding |
| 216 | Providing and fixing LOW HEIGHT STORAGE VENNER having depth 0.45m made up ofCOMMERTIOL(ISI-303) 18 millimetrethick Plywood for frame work shelves, shutters and back with 12millimetrethick plywood as per architectural designanddrawing and finish with 4millimetrethick Natural wood VENEER (Flitchess metallic burl vereer series ). confirming to (ISI 1328) and finished with Melamine polishing Matt or Glossy make and inside surface finish with French polish, including BTC lipping, 75millimetrebras hinges, bras screws, SS 304 grade handle, Drawer lock, 100millimetrebrass tower bolt, magnet, melamine polish two moulding, veneer, lipping antitermite treatment to plywood, and as directed by engineer In charge etc complete. |
| 217 | Supplying and installing of in position the signages \" FIRE ORDER\" it should contain the following matter on 3millimetrethick \"Opaque\" Poly vinyl chloridefoam board of computerized cut, Poly vinyl chlorideNon-reflective self adhesive vinyle painted foam board of 3\" x 4\".Product to be ADA compliant and modular system.Stilt Floor |
| 218 | Ground Floor |
| 219 | First Floor |
| 220 | Design, supply, fabrication and fixing of SS, non glare Signage board (2 ft. x 2 ft.- 1 One Number) for the accessible parking, as per the approved design and make, having 1.2millimetrethick SS non glare base plate and GArade 2/ Grade 1 Braille (raised dots)to be etched/ engraved and be raised 0.5millimetreabove base plate and Upper Case San Serif words and Universal Accessibility Symbol to be etched/ engraved and signage to be installed at a height of 2100millimetrefrom the ground level using a post of MS hollow square section (50millimetrex 50millimetre ) as per the installation procedure specified by the manufacturer and as per accessibility standards and up to the satisfaction of the engineer in charge |
| 221 | Design, supply, fabrication and fixing of SS, non glare multilingual Braille (raised dots) entrance signage (size 1 ft x 1 ft) as per the approved design and make,indicating the name of the building. Having 1.2millimetrethick SS non glare blue coloured base plate with the \"Universal Accessibility Symbol\" and Upper case Sans Serif words of height 15millimetreengraved on it along with the equivalent word/ s written in Hindi using Devnagri script of height 15millimetrein white colour. Grade 2/ Grade 1 Braille to be etched/ engraved and be raised 0.5millimetreabove base plate.The signage to be installed at the specified location on the compound wall near the site entrance gate installed at a height of 1200 millimetrefrom the finished ground/ floor level, using the necessary hardware specified by the manufacturer and to be installed up to the satisfaction of the engineer in charge .Stilt Floor |
| 222 | First Floor |
| 223 | Directional signage Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6\" x 9\" designed as per accessibility standards and having 4millimetrethick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15millimetreraised not less than 0.8millimetreabove base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15millimetreraised not less than 0.8millimetreabove base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200millimetrefrom FFL and as per the directions by the engineer in charge. |
| 224 | WALL MURAL- Supply and installation of wall mural in 20-25 millimetreSandstone with carving depth of 2-3millimetreaccording to specified design. Pasted on wall using UV resistant stone adhesive and necessary precautions. With water repellent PU coating on surface, as per drawing etc complete. |
| 225 | METAL OPEN CELL CEILING : Providing & fixing horizontal level Open cell Aluminium lay-in ceiling tiles with border panels forming board edge of size 600x600x38mm (Nominal) having cell size of 100x100mm made of AA-3003-H14 (Tempered) grade Aluminium suitable for architectural finishes in 0.35mm thickness as per in IS:2676 (1981) in Global white color. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60- 80 microns. The powder coating shall pass Salt Spray Test for 750 hours as per ASTM B117, QUV –A Test for 1000 hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000 hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. Tile shall have a Fire Performance class A as per GB 8624-2012. SUSPENSION: The tile shall be laid on 15 mm wide T - section flanges colour global white (matching to tile colour) having double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel clip fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel 90 gsm and pre-painted steel with baked polyester paint of 0T bending capability. , The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications below) at 1200mm maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from (Stilt Floor) - Stilt Floor |
| 226 | Ground Floor |
| 227 | Providing and fixing in position Gypsum board false ceiling with 12.5 millimetrethick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimetremaximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.Stilt Floor |
| 228 | Ground Floor |
| 229 | First Floor |
| 230 | NATURAL BAMBOO CEILING: Providingandfixing of Wooden Grill panel with backermade of natural bamboo with 24millimetreFace black exposed grid. The Grill panels shall bemade of rapidly renewable natural bamboo core having density 600+Kgs/m3 as per BSEN323 (1993) and bending strength of 96+ N/millimetre 2 as per BS EN310 (1993). The Grillpanel shall have a seven layer UV coating of thickness 0.09-0.11millimetreas per BS EN71 finished to natural or carbonized shades. The Grill panel shall be of nominal size 35x300x2400millimetrecomprising 8 blades/slats of 35x16x2376millimetrewith centre to centre spacing of 37.5millimetrefixed through Backer of size 12x22x300millimetrehaving centre to centre spacing of 300millimetreand additional end backers at 150millimetrefrom both the edges. The Grill panel shall have a fire performance of Class A according to ASTM-E84. The Grill panel shall have moisture content of 8-14% as per IS 1708 (Part 1):1986 and a Humidity Resistance (RH) of 70%. SUSPENSION: The tile shall be installed on 24 millimetrewide T - section flanges having rotary stitching on all T sections i.e. the Main Runner, 1200 millimetre and600 millimetreCross Tees with a web height of 43millimetre , 35millimetreand 30millimetrerespectively. The deflection loading of the system shall be 17.8 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 21.4kg/m. The end details of the main beam and cross tee shall be made of pre hardened steel fixed to the ends. The cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 100 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All exposed panel ends to be covered using edge caps. All wall angles to be covered using ledgers. Installation should be carried out as per Manufacturerrcommendedprocedure. The grid shall be installed with suspension system ofrcommendedmake. Stilt Floor |
| 231 | Ground Floor |
| 232 | First Floor |
| 233 | Providing and fixing in position steel fiber reinforced concrete ( S.F.R.C ) Frame and covers ( M40 GRADE ) (plain or strom water drain ) heavy duty of approved make including loading, unloadind, transportation, production year and pune municipal corporation, on top must be embossed. etc. complete as directed by engineer-in-charge (20 tonnes capacity ) Thr The Bidder shall procure Reinforced cement concretepipes and chamber covers from following suppliers 1) M/S Sneh Precast 2) M/S Kalokhe pipes and precast industries 3) M/S Poona Concrete Company If bidder wish to supply Reinforced cement concretepipes and chamber covers other than above suppliers, then it is mandatory to take approval of supplier from concern department. Third party inspection of Reinforced cement concretepipes and chamber covers is mandatory and should be witnessed by EIL/IR CLASS/SGS. The cost of third party inspection should be borne by contractor. 90 x 60centimetre size |
| 234 | Providing and constructing recharge pit of 2.0 metredeep and 1.0 metre diameterof pre-cast Reinforced cement concreterings with 6.5 inch diameterx 25 metredeep borewell at the floor of recharge pit including installation of combination of solid/perforated Poly vinyl chloridecasing pipe wrapped around with netlon mesh including 300millimetrethick sidefilling around outside of Reinforced cement concreterings (annular space) with 40millimetresize boulders including filling of recharge pit up to 0.5m depth with 25-75millimetreclean washed gravels from bottom up followed by 0.5 metredepth of 10- 25millimetreof clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI)grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI)grade finely washed etc.) media layer including covering with Reinforced cement concreteslab, manhole frameandcover, Poly vinyl chloriderungs, Poly vinyl chlorideendcaps, fittings etc. including arrangement for inletandoutlet pipe excavationandbackfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. |
| 235 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material up to a distance of 50 metres beyond the building are a and stacking as directed, including dewatering, preparing the bed for the foundation and necessary backfilling with available earth/murum, ramming, watering including shoring and strutting etc. complete.(Lift from 3 metre to 3.5 metre) By Mechanical Means |
| 236 | Providing expansion joints in reinforced cement concrete framed structure (interior columns) with plain premoulded filler with confirming to IS 1838,1961, 25 millimetrethick with 75 millimetrewide and 1 millimetrethick stainless steel plate finishing etc. complete as directed Stilt Floor |
| 237 | Ground Floor |
| 238 | First Floor |
| 239 | Terrace Floor |
| 240 | Providing expansion joints in Reinforced cement concreteframed structure (exterior column) with plain premoulded filler 25 millimetrethick with 75 millimetrewide and 1 millimetrethick stainless steel plate and finishing etc. complete Stilt Floor |
| 241 | Ground Floor |
| 242 | First Floor |
| 243 | Terrace Floor |
| 244 | Providing expansion joints in Reinforced cement concreteframed structure (at floor level) with plain premoulded filler 25 millimetrethick with 75 millimetrewide and 1 millimetrethick stainless steel plat and finishing etc. complete.Stilt Floor |
| 245 | Ground Floor |
| 246 | First Floor |
| 247 | Terrace Floor |
| 248 | Providing and fixing ivory Opal series European type wall-hung, of size 400 millimetrex 370 millimetrex 575millimetrewith approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100millimetredia C.I. plug bend inlet pipe all fittings, cuttingandmaking good walls, floors etc as directed by Engineer in charge. Stilt Floor |
| 249 | Ground Floor |
| 250 | First Floor |
| 251 | Providing and fixing white glazed urinal of series with Pressmatic auto closing valve of having 32millimetrediameter Poly vinyl chlorideflush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trapandsoil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge. |
| 252 | Providing and fixing divertor with overhead shower,shower arm,spout,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge. Stilt Floor |
| 253 | Ground Floor |
| 254 | First Floor |
| 255 | Providing and fixingChromium plated Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. Stilt Floor |
| 256 | Ground Floor |
| 257 | First Floor |
| 258 | Providingandfixing Handshower(healthfaucet)with8millimetre diameter 1mlongflexible tube having wall hook withapprovedmake including necessary sockets/ union nut etc. complete as directed by Engineer in charge.Stilt Floor |
| 259 | Ground Floor |
| 260 | First Floor |
| 261 | Providing and fixing chromium plated towel rod 16 millimetredia and 75centimetrein length including all accessories complete. Stilt Floor |
| 262 | Ground Floor |
| 263 | First Floor |
| 264 | Chromium plated soap dish (polyurethane) jaquar make continental (Cat. No. AQN 7733 ) (Stilt Floor)Stilt Floor |
| 265 | Ground Floor |
| 266 | First Floor |
| 267 | Providing andfixing 450millimetrex550millimetresize superiortype Belgium mirrorwith16millimetre diameternickel plated towel rod etc. complete..as directed by Engineer in charge .Stilt Floor |
| 268 | Ground Floor |
| 269 | First Floor |
| 270 | Providing and fixing Table top ivory wash basin of size 120x635x405millimetrerubber plugs and brass chain, with pillar cock,Chromium plated Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge.Stilt Floor |
| 271 | Ground Floor |
| 272 | First Floor |
| 273 | Bib tap 12millimetrebrass medium |
| 274 | Providing and fixing stainless steel sink of size 600 x 510 x 200 millimetreincluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. |
| 275 | Providing and fixingChromium platedsink cock with raised J\" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete.\" |
| 276 | Providing and fixingChromium platedAngular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. |
| 277 | Providing and fixing 25millimetrediameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber]. |
| 278 | Providing and fixing 15centimetre rigid Poly vinyl chlorideNahani trap including Poly vinyl chloridegrating ,bend,connectingpiece of Ultra Polyvinyl chloridepipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) (Stilt Floor)Stilt Floor |
| 279 | Ground Floor |
| 280 | First Floor |
| 281 | Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 millimetreand of DIA: 32millimetreand thickness 1.5millimetreof the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600millimetre(H) X 600millimetre(D) and 32millimetrediameterand thickness millimetreof the approved brand and make. 27c) Straight grab bar (2 NOS) Providing S.STEEL 304 GRAB RAIL (600 millimetre ),32millimetrediameterand thickness 1.5millimetreof the approved brand and make. |
| 282 | Providing , laying and fixing ,jointing Eco- drain 160 millimetreSN 4 Nu- Drain Ultra Polyvinyl chloridepipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. |
| 283 | Providing and fixing 100 millimetrediameterstabiliser pipe/ Poly vinyl chloridesoil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.Stilt Floor |
| 284 | Ground Floor |
| 285 | First Floor |
| 286 | Providing and fixing 75 millimetredia stabiliser pipe/ Poly vinyl chloridesoil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete (Stilt Floor)Stilt Floor |
| 287 | Ground Floor |
| 288 | First Floor |
| 289 | Providing, laying and fixing Poly vinyl chloridepipe of 40millimetrediameterwith fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Departmentchowky or as directed etc. complete. |
| 290 | Providing, laying and fixing Poly vinyl chloridepipe of 32millimetrediameterwith fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Departmentchowky or as directed etc. complete.Stilt Floor |
| 291 | Ground Floor |
| 292 | First Floor |
| 293 | Providing and fixing on walls/ceiling/floor 20 millimetrediameterChlorinated Polyvinyl chloridepipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Departmentchowky or as directed etc. complete. (Stilt Floor)Stilt Floor |
| 294 | Ground Floor |
| 295 | First Floor |
| 296 | Providing and fixing on walls/ ceiling/ floor 32 millimetrediameterChlorinated Polyvinyl chloridepipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Departmentchowky or as directed etc. complete. (Stilt Floor)Stilt Floor |
| 297 | Ground Floor |
| 298 | First Floor |
| 299 | Terrace Floor |
| 300 | Providing and fixing on walls/ ceiling/ floor 25 millimetrediameterChlorinated Polyvinyl chloridepipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Departmentchowky or as directed etc. complete.Stilt Floor |
| 301 | Ground Floor |
| 302 | First Floor |
| 303 | Providing and fixing on walls/ ceiling/ floor 25 millimetrediameterUltra Polyvinyl chloridepipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Departmentchowky or as directed etc. complete. (Stilt Floor)Stilt Floor |
| 304 | Ground Floor |
| 305 | First Floor |
| 306 | Providing and fixing on walls /ceiling/ floor 40 millimetrediameterUltra Polyvinyl chloridepipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Departmentchowky or as directed etc. complete (Stilt Floor)Stilt Floor |
| 307 | Ground Floor |
| 308 | First Floor |
| 309 | Providing and fixing on walls/ ceiling/ floor 50 millimetrediameterUltra Polyvinyl chloridepipe with necessary fittings, remaking good the demolished portion etc. complete. |
| 310 | Ball cock for 25millimetrediameterGround Floor |
| 311 | First Floor |
| 312 | Ball cock for 32millimetrediameter .Stilt Floor |
| 313 | Ground Floor |
| 314 | First Floor |
| 315 | Terrace Floor |
| 316 | Ball cock for 40millimetrediameter |
| 317 | Ball valves for 50millimetrediameter |
| 318 | Providing andfixing 40 millimetre . dia Ball cock medium type with Poly vinyl chloridefloat including sockets and necessary fittings and tested as per municipal requirements etc. complete.as directed by Engineer in charge |
| 319 | Strainer for 50millimetre |
| 320 | Strainer for 40millimetre |
| 321 | Providing and fixing High density Polythylein (HDP) container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres |
| 322 | Providing and fixing Poly vinyl chlorideRain water pipes of 160millimetreouter diameter and having wall thickness of 2.2 to 2.7 millimetreconfirming to I.S. 13592-1992 including proper rainwater receiving recess with Poly vinyl chlorideplug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall usingapproved wooden cleats projecting 25millimetreto 40millimetrefrom face of wall a fixing with clips of approved quality andnumber,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concreteor masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly vinyl chloridefittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (Stilt Floor)Stilt Floor |
| 323 | Ground Floor |
| 324 | First Floor |
| 325 | Terrace Floor |
| 326 | Providing , layingandfixing ,jointing Eco drain 160 millimetreSN 4 Nu Drain Ultra Polyvinyl chloridepipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. |
| 327 | Providing , constructing and fixing 450 millimetrediameterInspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 millimetreand height of 388 millimetrewith 160 or 200 millimetremain inlet (s) outlet and 110 and / or 160 millimetrebranch inlets, with 450 millimetrediameterUltra shaft pipe of High density Polythylene (HDP) E material having height of 460 millimetre , having perforated cover and frame fixing in 150 millimetrethick in c.c.1:2:4, having crushed sand bed of 150 millimetrethick of size 750 millimetrediameterIncluding excavation and refilling the sides of chamber by sand crushed cushioning 150 millimetrethickness, connecting all required Ultra Polyvinyl chloridefittings with rubber lubricant etc. |
| 328 | Providing , constructing and fixing 600 millimetrediameterInspection chamber made up of Polypropylene / polyethylene material Having 315 millimetrediameter inlet(s)/outlets and with eccentric reducers as per requirement to connect 160 millimetreand 200 millimetrepipes having thickness of 5 millimetreand 600 millimetrein height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 millimetrehaving Reinforced cement concretecover and frame fixing in 150 millimetrethick in c.c.1:2:4, having crushed sand bed of 150 millimetrethick of size 750 millimetrediameterIncluding excavation and refilling the sides of chamber by sand crushed cushioning 150 millimetrethickness, connecting all required Ultra Polyvinyl chloridefittings with rubber lubricant etc.complete. |
| 329 | RWH - Recharge Pit Providing and constructing recharge pit of 2.0 metre deep and 1.0 metre diameterof pre-cast Reinforced cement concreterings with 6.5 inch diameterx 25 metredeep bore well at the floor of recharge pit including installation of combination of solid/ perforated Poly vinyl chloridecasing pipe wrapped around with netlon mesh including 300 millimetrethick side filling around out side of Reinforced cement concreterings (annularspace with 40 millimetresize boulders including filling of recharge pit upto 0.5 m depth with 25-75 millimetreclean washed gravels from bottom up followed by 0.5 m depth of 10-25 millimetreof clean washed stones followed by 0.5 m of washed river fineaggregate (naturalsand /crushedsand Vertical shaft impact (VSI)grade finely washed etc.) including netlon mesh between each gravel/ fine aggregate (naturalsand /crushedsand Vertical shaft impact (VSI)grade finely washed etc.) media layer including covering with Reinforced cement concreteslab , manhole frameandcover , Poly vinyl chloriderungs ,Poly vinyl chlorideend-caps ,fittings etc. including arrangement forinletandoutlet pipe excavationandback filling as shown in the drawing .The rate shall be inclusive of all labour ,material ,wastage ,scaffolding ,transportation ,taxes ,including all leads, lift at all levels.All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. |
| 330 | Providing and fixing 15 centimetrex 10 centimetresalt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. |
| 331 | Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flamillimetre ability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid Poly vinyl chloride : -100millimetreOutlet pipe size rigid Poly vinyl chloride :-80millimetreGas outlet rigid Poly vinyl chloridewith Valve: 20millimetreBacteria imillimetre obilization Poly vinyl chloridemattes (on all partition) With DRDO TOT licensee and latest batch certificate(monthandyear of supply) and capacity as below k) Up to 400 user size (5mx2.0mx1.5m), Capacity of Biodigester:-15000 liters, Area oftop, bottom and side walls: - 41.00 sq.m, Area of partition walls: 12.00sq.m, Total weightof FRP: - 678.80 Kilogram, Bacteria inoculums quantity: - 5200 liters, Minimum |
| 332 | Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flamillimetre ability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid Poly vinyl chloride : -100millimetreOutlet pipe size rigid Poly vinyl chloride :-80millimetreGas outlet rigid Poly vinyl chloridewith Valve: 20millimetreBacteria imillimetre obilization Poly vinyl chloridemattes (on all partition) With DRDO TOT licensee and latest batch certificate(monthandyear of supply) and capacity as below b) Up to 15 user size (1.0 metre x1.0 metrex1.0 metre ), Capacity of biodgester:-1000 liters, Area of top, bottom and side walls: - 6 sq.m, Area of partition walls: 2 sq.m, Total weight of frp: - 54 Kilogram, Bacteria inoculums quantity: - 400 liters, Minimum thickness of side walls / top and bottom: 4millimetre , One Number of inside partitions: - 3, Minimum thickness of partition wall: 3millimetre |
| 333 | Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flamillimetre ability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid Poly vinyl chloride : -100millimetreOutlet pipe size rigid Poly vinyl chloride :-80millimetreGas outlet rigid Poly vinyl chloridewith Valve: 20millimetreBacteria imillimetre obilization Poly vinyl chloridemattes (on all partition) With DRDO TOT licensee and latest batch certificate(monthandyear of supply) and capacity as below c) Up to 25 user size (1.5 metre x1.0 metre x1.0 metre ), Capacity of biodgester:-1500 liters, Area of top, bottom and side walls:- 8 sq.m, Area of partition walls: 2 sq.m, Total weight of frp: - 82.80 Kilogram, Bacteria inoculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5millimetre , One Number of inside partitions: - 3, Minimum thickness of partition wall: 3millimetre |
| 334 | Providing and fixing Orissa Pan of size 580x445x260 millimetrewith approved make flush valve including trap, cast iron soil and vent pipe upto outside face of wall including 100millimetrediametercast iron plug, bend and necessary pipe connection, etc complete. |
| 335 | Excavation pit size 1.00 x1.00 x 1.00m for planting large flowering/ shady trees (plant height 2 to 4 mtr.)/ palm varieties of height (plant height 2 to 4 mtr.) in earth, soil of all types, soft murum, including removing the excavatedandunwanted material up to a required distance of 50 mtrs |
| 336 | Excavation pit size 0.60 x 0.60 x 0.60m for planting smallandmedium ornamental plants/ large flowering/ shady trees (plant height 1 to 2 mtr.)/ palm varieties upto height 1 to 2 mtrs. in earth, soil of all types, soft murum, including removing the excavatedandunwanted material up to a required distance of 50 mtrs. |
| 337 | Excavation pit size 0.45 x 0.45 x 0.45m for planting specimen plants in earth, soil of all types, soft murum, including removing the excavatedandunwanted |
| 338 | Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 1 x 1 x 1m ( consolidated thickness).Quantity of soil 0.653 cum x 1000/cum = 653/- |
| 339 | Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 0.60 x0.60 x 0.60m ( consolidated thickness).Quantity of soil 0.1414 cum x 1000/cum= 141.40/- |
| 340 | Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) (i. e. 3 parts Garden soil ) for excavated pit size area of 0.45 x 0.45 x 0.45m ( consolidated thickness).Quantity of soil 0.079cum x 1000/cum = 79/- |
| 341 | Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 1 x 1 x 1m. ( consolidated thickness).Quantity of FYM 0.202 cum x 1200/cum = 242.40/- |
| 342 | Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 0.60 x 0.60 x 0.60m ( consolidated thickness).Quantity of FYM 0.044 cum x 1200/cum = 52.80/- |
| 343 | Supplying on site well decomposed Farm Yard Manure FYM in 3:1 proportion (i.e. 1 part FYM ) for excavated pit size area of 0.45 x 0.45 x 0.45m ( consolidated thickness).Quantity of FYM 0.023 cum x 1200/cum =27.60/- |
| 344 | Mixing garden soil/siltandmanure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 1.00 x 1.00 x 1.00m. |
| 345 | Mixing garden soil/siltandmanure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 0.60 x 0.60 x 0.60m. |
| 346 | Mixing garden soil/siltandmanure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 0.45 x 0.45 x 0.45m. |
| 347 | Filling fresh garden soil / siltandmanure in excavated pit size area of 1.00 x 1.00 x 1.00m |
| 348 | Filling fresh garden soil / siltandmanure in excavated pit size area of 0.60 x 0.60 x 0.60m |
| 349 | Filling fresh garden soil / siltandmanure in excavated pit size area of 0.45 x 0.45 x 0.45m |
| 350 | Maintainance of Newly Planted tree varities having height 2mtr. - 4mtr. For First 30 days Only |
| 351 | Maintainance of Newly Planted tree varities having height 1mtr. - 2mtr. For First 30 days Only |
| 352 | Maintainance of Newly Planted smallandmedium size ornamental plants/ Specimen plant. For First 30 days Only |
| 353 | Well Developed, fresh, Healthy bright colour leves free from pest and diseasesFicus benjamina (30centimetre to 60cm) 2a-12 |
| 354 | Well Developed, fresh, Healthy bright colour leves free from pest and diseasesBougavillae Thema 30 to 50centimetre 7b-10 |
| 355 | Well Developed, fresh, Healthy bright colour leves free from pest and diseasespider lily—Hymenocallis (30centimetre to 45centimetre) 4-8 |
| 356 | Well Developed, fresh, Healthy bright colour leves free from pest and diseasesFicus Golden 30 to 45centimetre 2a-14 |
| 357 | Well Developed, fresh, Healthy bright colour leves free from pest and diseasesFox tail palm 3 to 4 ft 11a-4 |
| 358 | Well Developed, fresh, Healthy bright colour leves free from pest and diseasesAreca Palm 3 to 4 ft 11a-2 |
| 359 | Well Developed, fresh, Healthy bright colour leves free from pest and diseases Kaduneem 6 to 8 ft 6b-7 |
| 360 | Well Developed, fresh, Healthy bright colour leves free from pest and diseases Telecoma stans 50centimetre to 60centimetre 7c-2 |
| 361 | Well Developed, fresh, Healthy bright colour leves free from pest and diseases Royal palm 9ft and above 11e-2 |
| 362 | Well Developed, fresh, Healthy bright colour leves free from pest and diseases Schefflera variegated 45centimetre to 60centimetre 2b-25 |
| 363 | Well Developed, fresh, Healthy bright colour leves free from pest and diseases Aglaonema spp indoor plant 30centimetre to 45centimetre 10b-1 |
| 364 | Well Developed, fresh, Healthy bright colour leves free from pest and diseases Money Plant green indoor plant 10\" mostic pot 60centimetre to 90centimetre10b-8 |
| 365 | PREPARING LAWN (30centimetreS. DEPTH) :- Excavating the ground to a required depth of 30centimetres. Removingandconveying unwanted stuff to a required distance as directed. Filling fresh garden soil/siltandmanure in excavated area in 3:1 proportion to a height of 30cms.Mixing garden soil and manure thoroughly, well, leveling, watering on previous night. Planting required variety of lawn grass as directed and maintaining till well established by watering, weeding, clipping, rolling etc. complete. |
| 366 | PREPARING Shrubbery(30centimetreS. DEPTH) :- Excavating the ground to a required depth of 30centimetres. Removingandconveying unwanted stuff to a required distance as directed. Filling fresh garden soil/siltandmanure in excavated area in 3:1 proportion to a height of 30cms.Mixing garden soil and manure thoroughly, well, leveling, watering on previous night. Planting required variety of Shrubbery as directed( spacing 30cmx30cm)and maintaining till well established by watering( upto 30 days), weeding, clipping, rolling etc. complete. |
| 367 | Maintenance of soft scape area( Shrub, Ground covers) for 6 months (Rs23/Sqm/Annum) |
| 368 | Maintenance of soft scape area( Trees) for 6 months (Rs23/Sqm/Annum) |
| 369 | Maintenance of soft scape area( Lawn) for 6 months (Rs23/Sqm/Annum) |
| 370 | Mali for maintenance of Garden for 6 months (i.e 1 Mali for 2200 Sqm Area ) |
| 371 | Sub work 1 Estimate no 113130 of 2023-2024 : Providing Internal Electrification, External Electrification, Water System, Diesel Generator & Street Light to Proposed Construction For I. B. Resthouse Pune.Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 372 | Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 373 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 374 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 375 | Supplying and erecting Green colour earthwith 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (with Note 3) |
| 376 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 377 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 378 | Supplying and erectingGreen colour earth with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(with note 3) |
| 379 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 380 | Supplying and erecting Green colour earth with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (with note 3) |
| 381 | Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 382 | Supplying and erecting Green colour earth with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (with note 3) |
| 383 | Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 384 | Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 385 | Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 386 | Supplying and erecting modular type bell-push with indicator 2 modules 6A / 10A, duly erected on provided plate and box with wiring connections complete |
| 387 | Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 388 | Supplying and erecting modular type 32A, DP key tag switch with key tag, duly erected on provided plate and box with wiring connections complete. |
| 389 | Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 390 | Supplying and erecting modular type 3 pin 6 / 16Amultisocket with safety shutterISI mark approved make duly erected on provided plate and box with wiring connections complete. |
| 391 | Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box. |
| 392 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 393 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 394 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 395 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 396 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW |
| 397 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+2E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW(With note 3)(Two Way Control) |
| 398 | Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW |
| 399 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 400 | Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW |
| 401 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW |
| 402 | Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 403 | Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 404 | Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 405 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 406 | Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty |
| 407 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 408 | Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 409 | Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size. |
| 410 | Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 411 | Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 412 | Supplying and erecting Gate/garden light fitting with 200mm dia. glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No. FGODF/GLT |
| 413 | Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 414 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 415 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF |
| 416 | Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. |
| 417 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 418 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 20 litres per hour and storage capacity 20 litres with partially stainless steel body As per specification no. APWCR/ WC |
| 419 | Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system. |
| 420 | Supplying, erecting, testing and commissioning of 2kVA capacity online pure sine wave, with backup time of 0.30 Min. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS |
| 421 | Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete. |
| 422 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. |
| 423 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 424 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (Internal + Water Pump System+ Street Light) |
| 425 | Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 426 | Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (Internal + Water Pump System) |
| 427 | Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 428 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 429 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (Internal + Water Pump System) |
| 430 | Supplying, fixing and commissioning MCB type change over switch 2 pole, 40 A with 3 positions (I-O-II) with centre off position as per specification no. SWSWR/MCBCOS |
| 431 | Supplying, fixing and commissioning MCB type change over switch 4 pole, 40A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS |
| 432 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 433 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 434 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB (Internal + Water Pump System) |
| 435 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron /GI frame as per specification no. SW-SWR/MCBDB |
| 436 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. (Internal + Water Pump System) |
| 437 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 (Internal + Water Pump System) |
| 438 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 439 | Providing & erecting 4 Pole MCCB, 415V, 100 A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB (with note1) |
| 440 | Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB (with note 1) |
| 441 | Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB (with note 1) |
| 442 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 443 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 444 | Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 445 | Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 446 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 12 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs) (MCCB panel Board 1 to 3) |
| 447 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 400 A, 6 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs) |
| 448 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 400A, 8 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs) (MCCB panel Board ) |
| 449 | Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 12 way outgoing or 400A incoming and 6/8 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB. |
| 450 | Supplying and erecting 50 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC |
| 451 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (Internal + Water Pump System) |
| 452 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 453 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (Internal + Water Pump System+ Street Light) |
| 454 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 455 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 456 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 457 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 458 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (External + Diesel Generator) |
| 459 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 460 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 461 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (Internal + Water Pump System) |
| 462 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 463 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(UE), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 464 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 465 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100 mm height comprising all required standard accessories. |
| 466 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories. |
| 467 | Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 468 | Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE |
| 469 | Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 470 | Supply and erecting 9m (clear height) Fixed type high-mast (Top-100mm, Bottom- 200mm) with hexagonal /round bracket and foundation bolts suitable for max. 4 nos. flood light fixtures on provided foundation as per specification no.OH-PL/OPL (excluding luminaires). |
| 471 | Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 472 | Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm A/F, top 100 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 473 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 474 | Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 475 | Supplying & erecting inline D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 300 Amps as incomer & 6 Nos. 100 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos of Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete. |
| 476 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP (Internal + External+ Diesel Generator+ Street Light) |
| 477 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 478 | Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA (Internal + External+ Diesel Generator) |
| 479 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. (Internal + External+ Diesel Generator) |
| 480 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.(Internal + External+ Diesel Generator+ Street Light) |
| 481 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound, without gas cushioning ,hermetically Sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40℃ by thermometer in oil and 45℃ by the resistance methodin winding at full load rating, using type A winding insulation (kraft paper), with HV tapping (with off load tap changer) off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014, with necessary permissions of Electrical Inspector, as per specification no SS- TR-SL |
| 482 | Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG |
| 483 | Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete. |
| 484 | Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD |
| 485 | Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete. |
| 486 | Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete. |
| 487 | Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) |
| 488 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV |
| 489 | Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer. |
| 490 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 180 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 30.90 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG |
| 491 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 140 kVA up to 180 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.(with note 1) |
| 492 | Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP |
| 493 | Supplying and erecting minimum Three & above star rated 1 phase, 230 V, 50 Hz, submersible pump set of 0.75 KW/1HP for erection on open well, pump having delivery head from 30 to 15 m and discharge from 30 to 270 litres. per minute & pipe of Suction 32 mm/Delivery 25 mm diameter erected with necessary H type clamps as per specification No. WP-OSP |
| 494 | Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 495 | Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only. |
| 496 | Supplying & erecting PVC coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos) |
| 497 | Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . |
| 498 | Supplying & erecting automatic control panel for 1 Ph, 230 volt, A.C. Submersible/centrifugal pump set up to 3 HP consisting of DOL starter Of suitable relay range S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. |
| 499 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU |
| 500 | Excavating soft murum / soft soil road by chiselling for preparing pit for polesstay or earth plates or for laying cables, pipes & clearing the site by removingdebris & making the site good complete. (180KVA = 5.35m X 2.30m) |
| 501 | Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram) |
| 502 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). (180KVA = 5.35m X 2.30m X 0.3m ) |
| 503 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete (for 3 to 5m octagonal / conical GI pole) |
| 504 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). |
| 505 | Making M- 20 grade reinforced cement concrete foundation by consideringthe safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole). |
| 506 | Supplying and erecting high density polythene pipe ISI mark 32 mm dia. suitable for pressure of 6 kg/cm2 connected to jet/submersible pump with required material complete. |
| 507 | Supplying and erecting non return valve 65 mm dia in position made of gun metal complete. |
| 508 | KL-4761 Description -1X60w Polar Lighting Pole (3Mtr) Luminaire made of extruded aluminium alloy (grade 6063) with die-cast aluminium components and non corrosive SS fasteners. Shielded light source . For optimum illumination, these luminaires can be supplied in two different heights. Reflector system made of pure aluminium.Non yellowing UV stabilized clear polycarbonate diffuser.Silicone gasket. Mounting plate Die cast aluminium double powder coat with an anchorage unit and stainless steel fixing screws. Luminaire can be aligned on the mounting plate around 360°. Cable entries for through-wiring of mains supply cable. Integral constant current power supply.CRI (Ra) : >80 (90 CRI - On Request) Prewired with LED driver and suitable for operating on 240V,50Hz single phase ac supply.Ordering guide : KL-4761-CCT (Colour Temperature) Available CCT : 3000K, 4000K, 5700K. |
| 509 | Sub work 2 Estimate no 113130 of 2023-2024 : Providing fire Fighting System to Proposed Construction For I. B. Resthouse Pune.Supplying & erecting HMS PVC conduit 25mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. |
| 510 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 511 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 512 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 513 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 514 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 515 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware. |
| 516 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP |
| 517 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 518 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete |
| 519 | Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . |
| 520 | Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 1600 to 1800 LPM at 70 to 55 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 30kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP |
| 521 | Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP |
| 522 | Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP |
| 523 | Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 1600 to 1800 LPM at 70 to 50 m head driven by 45 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine, exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP |
| 524 | Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU\"s, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc.3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested. 6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps. 7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications. 9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge. 10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP For addition of capacity of main electric motor driven fire pump MFP (1 working) for hydrant system is more than 22kW, add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgears and motor starters for main & jockey pumps along with necessary accessories for main & jockey fire pumps MFP=(1working), JP = (1working + 1standby, alternate run per start in auto mode) For main electric motor driven fire hydrant system pump of 30kW capacity & relevant capacity jockey pump add Rs…. For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs....... The control for diesel engine comprises of automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps. |
| 525 | Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP |
| 526 | Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP |
| 527 | Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP |
| 528 | Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP |
| 529 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP |
| 530 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP |
| 531 | Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system. |
| 532 | Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system. |
| 533 | Supplying and erecting 80 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV |
| 534 | Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV |
| 535 | Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 536 | Supplying and erecting 75/80 mm dia. cast iron double flange sluicevalve complete with PN16 pressure rating, as per specification no. FF-VL/SV |
| 537 | Supplying and erecting 100 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV |
| 538 | Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV |
| 539 | Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 540 | Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 541 | Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 542 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 543 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 544 | Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 545 | Supplying and erecting 100 mm dia cast iron double flange NRV completewith PN16 pressure rating, as per specification no. FF-VL/NRV |
| 546 | Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 547 | Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 548 | Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 549 | Supplying and installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT |
| 550 | Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV |
| 551 | Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL |
| 552 | Supplying and erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FFFFA/NZ |
| 553 | Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC |
| 554 | Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/FMC |
| 555 | Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT |
| 556 | Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 557 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 558 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 559 | Supplying and erecting brass orifice plate having 6 mm. thickness, 160 mm outer dia with required diameter of inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OP |
| 560 | Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8\"x6\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 561 | Supplying, erecting testing and commissioning heat detector with combination \"ROR and Fixed Temp.\" complete as per specification no. FF-FAS/HD |
| 562 | Supplying, erecting testing and commissioning optical type smoke detector onsuitable back box with necessary connections complete as per specification no. FF-FAS/SD |
| 563 | Supplying, erecting, testing and commissioning manual call point (Pill box) withbreak glass push button and flip abort switch or agent release switch in metal enclosure complete as per specification no. FF-FAAS/MCP |
| 564 | Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR |
| 565 | Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU (Note increase rate by 2% for FRLS) |
| 566 | Supplying, installing, testing and commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2 Character LCD Display, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC, 0 - 49 Deg C, 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP |
| 567 | Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF SPR |
| 568 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 569 | Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete. |
| 570 | Supplying and erecting ABC powder type fire extinguisher as per IS 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. |
| 571 | Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint. |
| 572 | Providing Round bottom FIRE Bucket of 9 Litres capacity as per IS 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark on provided stand/ wall hook. |
| 573 | Supplying & installation auto glow (Viewing upto 15 mtr length) fire signages viz fir hydrant Fir Extinguishers Fire Exit Fire door Fire house box ect. Size of 600x200 mm |
| 574 | Sub work 3 Estimate no 113130 of 2023-2024 : Providing Spilt Type AC system to Proposed Construction For I. B. Resthouse Pune.Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 575 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 2.1TR to 2.3TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 576 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete. |
| 577 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete. |
| 578 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. (with note 2) |
| 579 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system |
| 580 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater/AC system. |
| 581 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 582 | Sub work 4 Estimate no 113130 of 2023-2024 : Providing 8 Passanger Lift (3 nos)to Proposed Construction For I. B. Resthouse Pune.Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 583 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete |
| 584 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. |
| 585 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. |
| 586 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 587 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 588 | Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 589 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB (Internal + Water Pump System) |
| 590 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 591 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 592 | Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 593 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 594 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 595 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP |
| 596 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. |
| 597 | SITC of Electric Traction Passenger Lift with · Rated capacity :- 8 Passenger/544Kg · Floors :- B+G+1 floor (3 Stops/3 Landings) · Travel :- 3 to 15 mtrs· Location of Lift Machine:- MR · Rated speed :- 1.0 mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of 1300 mm wide x 1100 mm deep x 2250mm high · Lift shaft available having clear size of 1900 mm wide x 1900 mm deep, 1900 mm Pit depth, 4500 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. ARD complete with necessary SMF VRLA batteries. Fireman controller having fireman switch at fire Landing. CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine ofGearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel], this includes all necessary accessories like LOP\"s with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, traveling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. (For Lift travelling up to six floors or at a speed of 1.0 mps, add as below,) For Full Collective control system, add as below. For Lift travelling above First floor & up to Sixth floor |
| 598 | SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete. |
| 599 | Sub work 5 Estimate no 113130 of 2023-2024 : Providing Heat Pump System & 25KWP Solar System to Proposed Construction For I. B. Resthouse Pune.Supplying, installing, testing and commissioning of Commercial Heat pump, having dimension: 1020 x 846 x 1840 (mm), Input power: 6.02 kW, 400 V, 3 Ph, 50 Hz, Output power: 19.8 kW having hot water temperature range 35°C to 52°C and ambient temperature range for max. efficiency 7°C to 43°C, centrally controlled operation, operational noise level: 65 dBA with necessary accessories complete with 5 years ON-SITE warranty. |
| 600 | Supplying, installation and testing and commissioning of storage type Mild Steel mixing water tank of capacity 3000 ltrs. tested to a pressure of 8 kg/cm2 insulated with 50 mm thick rock wool with wire mesh around and cladded with 26 SWG aluminium of dish end type with working pressure of 6 kg/cm2, fabricated with 6 mm thick MS plate and dished ends with 8 mm thick plates complete with man hole cover, inner side of the tank coated with FRP coating of 3 mm thickness withstand temperature of 90°C provided with collars of 2\" BSP for provision to install 6 numbers of electrical heating coils if required with thermal sensors for automatic operation and integrated into the electrical circuits of the circulation pumps and the heat pump with safety valve drain, inlet and outlet nozzle, pressure gauge with all necessary accessories complete. |
| 601 | Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 150 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG. |
| 602 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 603 | Supplying and erecting AC three phase HT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz, with backlit LCD display, optical port & RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. |
| 604 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 605 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP |
| 606 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 607 | Sub work 6 Estimate no 113130 of 2023-2024: Providing TV, Telephone , Lan & CCTV System to Proposed Construction For I. B. Resthouse Pune.Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. (Lan System + CCTV System) |
| 608 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC (Lan System + CCTV System) |
| 609 | Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. |
| 610 | Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 611 | Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 612 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected |
| 613 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 614 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 615 | Supplying & erecting 10 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW |
| 616 | Supplying & erecting 20 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW |
| 617 | Supplying & erecting 100 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW |
| 618 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG- 11 as per specification No. WG-TW |
| 619 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW |
| 620 | Supplying and erecting 15m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. |
| 621 | Supplying & erecting HDMI Extender Over RJ45 Ethernet Cable Cat 6, 60m/200ft complete |
| 622 | Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 623 | Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 624 | Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW |
| 625 | Supplying and erecting broadband splitter unit with 1 input & 2 output RJ 11 female connectors complete. |
| 626 | Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete.(with note -Add Rs. 38159.00 for additional 16 extension card for digital (hybrid) type EPABX -two numbers) |
| 627 | Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete |
| 628 | Supplying and installing cat-6 LSZH cable suitable for networking as per specification no. WG-COC/NC (Lan System + CCTV System) |
| 629 | Supplying and erecting LSZH armoured multimode optical fibre cable with 12 fibres, core dia 50/125 µm (OM4) suitable up to 10 GBPS ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC |
| 630 | Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 631 | Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 632 | Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete. |
| 633 | Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS |
| 634 | Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WGNWC/GBS |
| 635 | Supplying, fixing, and configuring 1-port mini-GBIC SX MM fibre transceiver (up to 550m, support 3.3V power) erected in provided rack complete. |
| 636 | Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL |
| 637 | Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. (Lan System + CCTV System) |
| 638 | Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO |
| 639 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 640 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK |
| 641 | Supplying and fixing 15U wall mount rack (Dimension-DxWxH – 500x600x767 mm) as per specification No. WG-NAS/RAK |
| 642 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 643 | Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor : minimum 1/2.8\" Progressive Scan CMOS,Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream,Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant,minimum IR distance : 50m,Lens Type : 2.8/4/6 mm Lens, fixed focal,Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m.Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°.Power Supply : Support 12VDC & PoE,IP67, IK10 - Vandal Resistant.Built in micro SD/SDHC/SDXC card slot of minimum 128 GB,Built in microphone.minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out× 1.Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance.Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection.Operating temperature ( -30 to 60° C ) .Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed,FTP disabled.Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol.RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM |
| 644 | Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8\" Progressive Scan CMOS,Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream,Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant,minimum IR distance : 50m,Lens Type : 2.8/4/6 mm Lens, fixed focal,Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m.Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°.Power Supply : Support 12VDC & PoE,IP67, IK10 - Vandal Resistant.Built in micro SD/SDHC/SDXC card slot of minimum 128 GB,Built in microphone.minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out× 1.Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance.Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection.Operating temperature ( -30 to 60° C ) .Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled.Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol.RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM. |
| 645 | Supplying, installing, testing & commissioning of 32/40 Ch. Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI/VGA outputs, provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080.Support H.265 or higher, H.264, MJPEG,Incoming Bandwidth 250Mbps with minimum 4 SATA Hard Disks, ANR Technology,4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB,minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps selfadaptive Ethernet interface,ONVIF conformance,Multiple network monitoring: Web viewer .support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS.RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specification no. CCTV-NVR |
| 646 | Supplying & erecting 55\" professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W,Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON |
| 647 | Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail