| 1 | fixing of following sizes of medium class PVC conduit spared/oldavailable ATSTORESalong with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 2 | (a) 25mm |
| 3 | (b) 32mm |
| 4 | Supplying and fixing of following sizes of medium class PVC conduit(Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 5 | (a) 25mm |
| 6 | (b) 32mm |
| 7 | Supplyinstallationtesting andcommissioning of 18W+ LED Surface/recess,squareorroundMounted light luminary fittingshape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast AluminiumHeatSinkandP.F.>0.95,THD<10%,CCT5700K,CRI80.The LEDwithUsefullifeof50000HrsatL70,seperatedriver,heatsink, earthing provision.. The Inputvoltage rangeshallbe150V to270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 &LM80testreportshouldbefromgovtapprovedIn-houseNABLlab/ governmentofIndia.ThejobincludesAMC(reckonedfromdateof successful commissioning) of lighting fixturesfor aperiod ofTwo years,which includes replacement offixtures ofPhilips/ Havel\"s /Wipro make/ sample to be approved before installation.. |
| 8 | Fixing testingandcomm.OfsurfacemountedLEDBattenAlimunium Housing,18watt +(Plus)old/spared commercialseriesasavailableatStores |
| 9 | S/Ftestingandcomm.OfsurfacemountedLEDBattenAlimunium Housing,18watt +(Plus)commercialseries(cool/warm)4ft.Philips make /Havell/ Crompton make of eq. standard. sample to be approvedbefore installation. |
| 10 | Fixingtesting and comm. Of MCB\"s of the below mentioned capacities insub main controls spared/old available at stores GDC bla |
| 11 | a) 6-32 Amp SP MCB |
| 12 | b) 40-63amp DP MCB |
| 13 | S/Ftestingandcomm.OfMCB\"softhebelowmentionedcapacitiesinsub main controls legrandC curve/ Schinider/ L&T ./equivalent make as directed by engineer incharge. |
| 14 | a) 6-32 Amp SP MCB |
| 15 | b) 40-63amp DP MCB |
| 16 | Fixing and drawing following sizes of FRLS PVC insulated copper conductor,(Havell/Polycab/ Fenolex/ Anchor make.) single core cable in the existing surface/recessed steel/ PVC conduit as required including making necessary connections as required. |
| 17 | (a) 2 x 1.5 sq. mm |
| 18 | (b) 2 X 2.5 sq. mm |
| 19 | ( c ) 2 X 4 sq. mm |
| 20 | (d)2 X 6 sq. mm |
| 21 | ( e )2 X 10 sq. mm |
| 22 | (f) 2 X 16 sq. mm |
| 23 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor,(Havell/Polycab/ Fenolex/ Anchor make.) single core cable in the existing surface/recessed steel/ PVC conduit as required including making necessary connections as required. |
| 24 | (a) 2 x 1.5 sq. mm |
| 25 | (b) 2 X 2.5 sq. mm |
| 26 | ( c ) 2 X 4 sq. mm |
| 27 | (d)2 X 6 sq. mm |
| 28 | ( e )2 X 10 sq. mm |
| 29 | (f) 2 X 16 sq. mm |
| 30 | fixing following modular switch/ socket ( Havell/Anchor/ SSK make)on the modular plate & switch box including connectionsetc. as required, the job includes the cost of modular plate and switch boxes.( old/spared available at stores) |
| 31 | 5/6 A switch |
| 32 | 15/16 A switch |
| 33 | 3 pin 5/6 A socket outlet |
| 34 | 6 pin 15/16 A socket outlet |
| 35 | Supplying and fixing following modular switch/ socket ( Havell/Anchor/ SSK make)on the modular plate & switch box including connectionsetc. as required, the job includes the cost of modular plate and switch boxes. |
| 36 | 5/6 A switch |
| 37 | 15/16 A switch |
| 38 | 3 pin 5/6 A socket outlet |
| 39 | 6 pin 15/16 A socket outlet |
| 40 | Supply, installation , testing and commissioningof LED based Flood light, housingmadeupofpressurediecastaluminumAlloywitheffective thermalmanagement,sturdinessandembossedbrandname/logoname of manufacturer. The fixture should have a minimum system efficacy of greaterthan120lumen/Watt andaminimumsystemlumenoutputof 18000lumensandmaximumsystemwattageof150Watts.Thefixture shall have a CRI of minimum 70, SDCM<5. The fixture shall be designed forasystemlifeof50,000hours@70%lumenmaintenance.Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact ResistanceRatingofIK>=07withtoughenedglasscover.Thefixture driver should have an operating voltage range of 140-270 V, inner surge protectionof>=4KV,PF>0.95andTHD<10%atfullload.Drivershould cutoffathighvoltageof320voltforsafety.Thefixtureshouldcomply withtheparametersasperIS10322.TheLEDdrivershouldcomplyto IEC61000-3-2 ed.3.2, 2009 for Harmonics. Manufacturer shall have inhouselabapprovedbyNABL.LM79andLM80reportsneedtobe submittedfromaNABL/ULaccreditedlabtoverifyaboveparameters. Philips/Havell(JetaAris)/Wipro/Cromptonmake(sampletobe |
| 41 | Supply,installationtestingandcommissioning ofenergysavingLEDlamps Havell/C&S/Philips make . |
| 42 | b) 15 Watt |
| 43 | Supply installation testing and comm.of 10- 16 amppower extension box( 1 No. 6 amp switch,1 No. 16 amp switch, 3 No. 6 amp Multi socket and 1 No.6/16 Socket) with suitable size lead and top. C&S make. |
| 44 | Providing and fitting of 15 amp SS combineSSK / Anchor make. |
| 45 | Supply fixing testing and comm. Of backlite holder /batten holder/angleholder/ceiling rose SSK/Anchor make incl. PVC Block. |
| 46 | Providing and fittting of 15 amp 3 pin topSSK/anchor make. |
| 47 | Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel made out of 2mm thick M.S. sheet, floor/wall mounted, vermin and dust proof, Outdoortype with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account,and other allied accessories etc. as required.( size may vary as per site requirement) |
| 48 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. |
| 49 | Normal INCOMING:d) onload Change over switch 160 Amp for generator.Front operated. |
| 50 | e) 4 No. of Aluminium Bus Bar of 200 Amp. |
| 51 | c)Digital meters and phase indicators -1 set. |
| 52 | OUTGOING:b)63 amp DP MCBK Legrand/ Shinider/ Eq. standard make. |
| 53 | c) space for 12 way MCB\"s |
| 54 | S/L , testing and commissioning of PVC alluminium armoured cable650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard makeas directed by engineer incharge andmaking end termination with brass compression gland and aluminium lugs of required size. |
| 55 | b) 50 sq.mm 3.5 core |
| 56 | fixingfollowingway,Triplepoleandneutral/singlepoleandneutral, sheetsteel,MCBdistributionboard,( legrand/Shinider/ABBmake)240 V,onsurface/recess,completewithtinnedcopperbusbar,neutralbus bar, earth bar,din bar, interconnections, powder painted including earthingetc.asrequired.(ButwithoutMCB/RCCB/Isolator)24way( spared/old available at stores) |
| 57 | Operationand maintenance of already existing 63 KVA D.G Set installed at indoor stadium baramulla.the job includes necessary servicing of D.G setby way of M.Oil change, change of air/fuel filters, coolant and allied works etc. priortoitsoperation,periodiccheckupsduringtheperiod. the job also includes connecting of generator set to the load as per site requirements.thejobalsoincludesstationingofoperating personel(2 No.)round the clock at the site including there boarding and lodgingfor providinguninterruptedpowersupplytotheinstallationduringpoweroutages from the PDD Source.( Complete job) |
| 58 | Supply and filling of Diesel oil for running of D.G set including its storagein barrels. |
| 59 | Supply installationtesting and comm.ofMCCB of following rating alongwith sheet steel enclosureLegrand/Schenieder/ L&T make. |
| 60 | b) 160 amp 4 pole 36 K |
| 61 | Wiringforlightpoint/fanpoint/exhaustfanpoint/callbellpointwith1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Anchor/ polycab make) single core cable in surface / recessed medium class PVC conduit(excludingthecostofconduit),withmodularswitch(Anchor roma urban/ Eq. make), modular plate, suitable GI/ PVC Heavy duty box andearthingthepointwith1.5 sq.mmFRLS PVC insulatedcopperconductor single core cable etc. as required. |
| 62 | Supply, laying overhead, testing and comm. Of 16mm2 core 650/1100 V grade unarmoured Aluminium cable Havell/Polycab/Eq. standard make. |
| 63 | Taking of photographs of size 125mm*100mm preexecution, during ExecutionandExecutiontobesubmittedwithbillcompletejob(GeoTagged photographs showing Longitude and Latitude ) |
| 64 | Engagingofskilledlabourfordismentallingofold/defunctmaterialandalso for carrying out other allied works. |
| 65 | SITC of 160 A Manual changeoversitch Havells/SSk/Anchor make |
| 66 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit,Power Factor not less than 0.9, Service Valueincluding safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hookcomplete . USHA Striker Galaxy/Havells Oyster matalic/Crompton Aura/equivalent make as directed by engineer incharge. |