| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, poles struts, laying of cables/pipes, etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 2 | All as per above item No 1herein before butexceeding 1.5 mtr depth in soft/loose soil |
| 3 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and as directed. |
| 4 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soils complete all as specified and as directed. |
| 5 | Supply & spread dry river sand intrenches for cable protection all as specified and as directed |
| 6 | Supply and laying un-reinforced precast concrete cable cover Class LV, Type I,flat,size 250 mm x 150mm x 40mm laid in trenches as in protection of UG cables all as specified and as directed. |
| 7 | Taking down existing defective LED street/security/flood/post toplight fittingsof any description and type from pole/ walls of buildings of any heightcomplete, after disconnecting the electrical connections and re-fixing the same in position after replacement of defective parts and accessories including connecting up and testing for satisfactory functioning complete all as specified and directed.Note:-(i) Replacement of spares and connected items shall be measured and paid as supply only under relevant item of schedule.(ii)Replacement of unserviceable spare parts/ accessories of the light fittings and replacement of brackets required for defective light fittings shall be measured and paid separately at supply only rates under relevant items of this schedule. (iii)Replacement of screws, nuts, bolts and consumables shall be deemed to be included in the rate quoted and no extra payment shall be allowed. (iv)Contractor or his representative will attendunserviceable street light/faulty complaintsand ensure completion of fault at the earliest and copy of the report to be submitted to the Engineer-in-Charge. (v)All tools and plants,ladder required shall be brought by the contractor to the site and rate quoted shall deem to include for the same also. |
| 8 | Supply only high energy efficent constant currentelectronic driver suitable for 220v,50hz, LED street light fitting 18/36 Watts LEDluminaires, 230 Volts. Make : Crompton /Bajaj/Philips/Havells/Wipro |
| 9 | Supply only high energy efficent constant currentelectronic driver suitable for 220v,50hz, LED street light fitting 40/45/50/60 Watts LEDluminaires, 230 Volts complete all as specified and as directed. Make : Crompton /Bajaj/Philips/Havells/Wipro |
| 10 | Supply only high energy efficent constant currentelectronic driver suitable for 220v,50hz, LED street light fitting75/80/90 Watts LEDluminaires, 230 Volts complete all as specified and as directed.Make : Crompton /Bajaj/Philips/Havells/Wipro |
| 11 | Supply only high energy efficent constant currentelectronic driver suitable for 220v,50hz, LED street light fitting 100/120 Watts LEDluminaires, 230 Volts complete all as specified and as directed.Make : Crompton /Bajaj/Philips/Havells/Wipro |
| 12 | S & F inreplacement of sub main wiring from street light to junction box with two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 1.5 sqmm in and including heavy grade PVC conduitand itsaccessories with fixing arrangements on pole surface, wall, ceiling etc including 1.5 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC conduitand two run of copper conductor together taken as one length for measuring unit length. |
| 13 | S & F in replacement of sub main wiring from street light to junction box with two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 2.5 sqmm in and including heavy grade PVC conduitand itsaccessories with fixing arrangements on pole surface, wall, ceiling etc including 2.5 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC conduitand two run of copper conductor together taken as one length for measuring unit length. |
| 14 | S & F in replacement of service wire 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm x 2 Core nominal cross section complete all as specified. |
| 15 | S & Fin for replacement of LT UG cable10 Sqmm x 2 Core1100 Volts grade XLPE insulated, steel tape armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including, lugs/ thimbles/ ferrules including connecting, testingcompleteall as specified and as directed. |
| 16 | S & F in for replacement of LT UG cable16 Sqmm x 4 Core1100 Volts grade XLPE insulated, steel tape armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including, lugs/ thimbles/ ferrules including connecting, testingcompleteall as specified and as directed. |
| 17 | S & F in for replacement of LT UG cable25 Sqmm x 4 Core1100 Volts grade XLPE insulated , steel tape armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including, lugs/ thimbles/ ferrules including connecting, testingcompleteall as specified and as directed. |
| 18 | Supply erecting and fixing in replacement of Steel tubular swaged poles 9mtr long complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 and markingZEBRA pattern with alternate yellow and black colour tosteel tubular poles 1.5m from the bottom of pole and one coat of aluminium painting for the remaining portion of pole includingnumbering of poles complete including necessary earhwork, PCC foundation, plinth protection etc all as specified and directed.Note (Excavation, earth work and sand cushioning,brick protection, pole foundation , coping, plinth protectionetc. Shall be measured and paid separately under relevant item of schedule |
| 19 | Material and labour for PCC 1:3:6 type C-2 using 40 mm graded aggregate for foundations of poles/stays complete including form work all as directed. |
| 20 | Material and labour for PCC 1:2:4 type B-1using 20 mm graded aggregate for coping of poles and platform incl. necessary form work fair and finishing without using extra cement complete all as directed. |
| 21 | M&L in for Boring of holes under road pavement hard standing by manual boring incl making good the disturbed surfaces complete all as specified and directed |
| 22 | Supply and lay GI Pipein repair light grade 50 mm dia for cable protection laid in trenches or fixed on pole/wall complete all as specified and as directed. |
| 23 | Supply and fix PVC conduit pipe 25mm dia heavy duty secured to poles with necessary clamps and fitting such as bolts, nuts fixed in repairs all as specied and as directed |
| 24 | S&F in replacementGI pipe40/50 mm bore, light grade,1.50 metres long,bent to shape required as in street light brackets, fixed to poles/ wallswith suitable size MS clamps, nuts & bolts complete,all as specified and as directed. |
| 25 | M & L for painting of steel tubular poles with one coat of aluminium paint and also markingZEBRA pattern with alternate yellow and black colour tosteel tubular poles upto1.5m from the bottom of pole includingnumbering of poles using synthetic enamel paint complete all as specified and directed |
| 26 | M & L for painting of RCCpoles with one coat of white cement based paint and also markingZEBRA pattern with alternate yellow and black colour tosteel tubular poles upto 1.5m from the bottom of poleincludingnumbering of poles using synthetic enamel paint, complete all as specified and directed |
| 27 | Supply and fix PVC cable loop box, size not less than 200 mm x 140 mm x 95 mm, out door type,duly fitted on bottom of RCC/ steel poles with suitable clamp, nuts, bolts & washers complete to accommodate and including one No of 6 Amps single pole MCB, & suitable alumiium busbar of 3 phaseporcelain insulated connectors for incoming and outgoing connections fixed in repairs all as specified and directed. Make Sintex or techno commercially equivalanet. |
| 28 | Supply and fix in replacement of sheet metal enclosurestreet light timer control board 3ph 415V , 50HzIP >54 having digital programmable (24 Hrs) timer switch, contactor assembly 415V 4 pole, 65 Amps with auxiliary contact, MCB TPN 415V, 63 Amps capacity as incommer, with manual/auto bypass arrangement, connector terminals& status indicators including testing complete all as specified and directed.Make : Indoasian/havells/Legrand/HPL |
| 29 | Supply and fix in replacement of modular contactor with auto/manual override option 4P, 415V , 50Hz , 63A ,suitable for existing timer control board complete all as specified and directedMake : Havells Cat No :DHPMC063340M or techno commercially equivalent in L&T/Siemens/Indoasian |
| 30 | Supply and fix in replacement of modular contactor with auto/manual override option 2P, 230V , 50Hz , 63A ,suitable for existing timer control board complete all as specified and directedMake : Havells Cat No :DHPMF063220M or techno commercially equivalent in L&T/Siemens/Indoasian |
| 31 | Supply and fix in replacement of MCBTPN, 415V , 50Hz , 63A, 10kA, \"C\" typesuitable for existing timer control board complete all as specified and directed |
| 32 | Supply and fix in replacement of MCBSPN, 220V , 50Hz ,10kA, \"C\" type, 5-32Asuitable for existing timer control board complete all as specified and directed |
| 33 | Supply and fix in replacement of MCBSP, 220V , 50Hz ,10kA, \"C\" type,5-32A for street lightcomplete all as specified and directed |
| 34 | Supply and fix in replacement of Digital Multi function time switch with programmable fuction to ON/OFF the Time switch to Control a Street Lights including connecting up and testing complete all as specified and directedMake : Havells Cat No : DHTLB1016 or techno commercially eqivalent in L & T /HPL /Indoasian |
| 35 | M & L for reparing/servicing solar street light including cleaning of solar panels, checking & cleaning battery and all connection terminals ,distille water topup , solar battery charging controller , LED driver complete all as specified and directed |
| 36 | S & F in replacement of solar street light lead acid battery 12v 75Ah complete all as specified and directed Make : Exide/Amaron/Sonic |
| 37 | S & Fix in replacement of MPPT SolarPWM Controller suitable for battery sizes 12/24/36/48V40/60Aincluding connection and testing complete all as specified and directed by engineer in charge.MAKE : ASHA POWER (NEON 60 ) or techno commercially equivalent as per Site requirement . |
| 38 | S & Fix in replacement of Monocrystalline Solar Photo voltaic 12V , 180 W panel suitable for Solar street light including fixing on existing mounting brackets with appropriate angle 45˚to 60˚to attain maximom efficency including connecting and testing complete all as specified and directed |
| 39 | S & Fix in replacement of Solar Panel DC MC4 connector including ternination with suitable lugs complete all as specified and directed bt engineer in charge |
| 40 | S & F in replacement ofpost top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.Make : Philips/Havells/Crompton/Bajaj |
| 41 | S & F in replacement ofLED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.Make : Philips/Havells/Crompton/Havells |
| 42 | S & F in replacement of LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.Make : Philips/Havells/Crompton/Havells |
| 43 | S & F in replacement of LED Security street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.Make : Philips/Havells/Crompton/Havells |
| 44 | S & F in replacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.Make : Philips/Havells/Crompton/Havells |
| 45 | S & F in replacement of LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. Make : Philips/Havells/Crompton/Havells |
| 46 | S & F in replacement of LED Bollard with robust design outdoor IP65 of cat pt No LBLTW-10-WW of Crompton or techno commercially equivalent and necessary fixing arrangementcomplete all as specified and as directed Make :HavellsPhilips |
| 47 | M&L for shifting of solar water heating system of any capacityfrom existing location to new location or same locationas per user requirement and installing, commissioning and testing complete all as specified and as directed.Note:Stages for the same will be measured and paid seperately |
| 48 | S & F in replacement Heating element with rubber gasket threaded/ push type 230V, 3KWall as specified and as directed.Make: Theeta/Racold/Philips ISI Marked |
| 49 | M&L for servicing of100 litres capacity Solar flat plate collector box after disconnecting the existing water supplyfrom any height of the building,dismantling the box, cleaning and servicing the Copper/aluminium Plates/ sheets/ angles and solar glass panel including replacement of defective/ worn out components and re-assembling the box connecting up water connections and testing for satisfactory performance complete all as specified and as directed.Notes: (ii)Replacement of Solar glass panel if required shall be measured and paid separately under respective items of this Schedule. |
| 50 | All as per item No. 3 above but200 litres capacity Solar flat plate collector box |
| 51 | All as per item No. 3 above but300 litres capacity Solar flat plate collector box |
| 52 | All as per item No. 3 above but500 litres capacity Solar flat plate collector box |
| 53 | S&F in replacement 5mm thick toughened plain glass panels suitable for solar water heater plate collector box, suitable for existing make all as specified and as directed. |
| 54 | S&F in replacementwater tubes, 15 mm bore, mediumgrade, galvanised, with all fittings, fixedcompleteto walls and ceiling or laid in floors as in short lengths, all as specified and as directed.Make: Jindal/Tata/Zenith |
| 55 | All as per item No. 8 above but20mm bore |
| 56 | All as per item No. 8 above but25mm bore |
| 57 | M&L for servicing of100 litres capacity Solar water heater with electric back up system after disconnecting the existing water supply/ electrical connections from any height of the building, transporting the heating/storage tank to authorised service station and backincluding stripping out the hot water vessel by taking out the outer cover, insulating materials etc. and continuous brazing of the inner container for arresting leakages including replacement of defective / worn out spare parts and re-assembling the system and re-installed at the same location, connecting up water/ electrical connections and testing for satisfactory performance complete all as specified and as directed.Notes: (i)Servicing of Flat plate collector shall be measured and paid separately under respective items of this Schedule. |
| 58 | All as per item No. 11 herein before but200/300 litres capacity Solar water heater with electric back up system |
| 59 | S & F in replacementthermostat suitable for solar water heater upto 300 litres capacity and range 0to 80 degree centigrade all as specified and as directed.Make: Theeta/Racold/Philips ISI Marked |
| 60 | M& L for Cutting screwing existing steel tubing 15mm for alteration or additionals or lengthening screw on pipe to form connector complete all as specified and as directed. |
| 61 | All as per item No. 14 above but20mm bore |
| 62 | All as per item No. 14 above but25mm bore |
| 63 | S&F in replacementof solar collector panelFlat plate collector based of toughned tempered glass of 4mm thick and cladding with aluminium sheet 26 SWG complete with copper rising tube,copper heater tubes,copper sheet and absorber forsolar water heater complete all as specified and as directed. |
| 64 | S &F in replacement25mm thick bonded mineral wool pre-formed \"SNAP ON\" pipe sections of density 144 kg/ cumconforming to IS 9842, lagged alround to hot water pipe line of 20mmbore,suitable for existing make all as specified and as directed. |
| 65 | S&F in replacement Gun metal gate valves,with iron wheel head, screwed both ends for 25 mm bore GI pipe, complete all as specified and directed. |
| 66 | S & F in replacement closing tap cast copper alloy chromium plated screwed for iron pipe of size 15 mm dia including taking down old complete all as specified and as directed. |
| 67 | M&L for Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burrieddirectly in groundverticallyto a depth not less than 2.25 metrebelowgroundlevelwith topedgeof theearth plate at a depth not less than 1.5 mtr belowgroundlevelearth platesurrounded from all sides by 15cmthickpacked layer ofcharcoal dust and common saltfillinginalternate layers andelectrodeconnectionby usingearth leadGIwire4mm dia ( 8 SWG)by meansof bolts, nuts, check nutsand washersmade of galvanised ironand thimbles and other endof theearth wire connectedto mainswitch boardprotected by galvanised iron light grade pipe 15mm borein wall/floor/andGI Pipe 20mm borelight grade forwatering with funnel and wiremesh PCC chamber in cementconcrete 1:3:6 typeC-2 and RCC pitcover includingnecessaryexcavation andearth work in anytype ofsoil, returningfilling approved soil and disposed of surplussoilto adistancenotexceeding 50 Mtraway all as shown inelectrical plateNo 3ofSSR 2009( Part-I). |
| 68 | S & F in replacement stop valve 20 mm dia cast copper alloyscrewed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed including taking down old complete all as specified and as directed. |
| 69 | S&F in replacementTemperature & Pressure Release Valve for Pressurized System, Spring Type complete all as specified and directed. |
| 70 | M&L PCC (1:3:6) type C1 using 20mm graded stone aggregate for mass concrete complete all as specified and as directed. |
| 71 | Supply and fix in replacement hot water pipe duly insulated with glass wool and aluminium cladding of dia 15 mm bore complete all as specified and directed. |
| 72 | Supply and fix inreplacement hot water pipe duly insulated with glass wool and aluminium cladding of dia 25 mm bore complete all as specified and directed. |
| 73 | S & F in replacement Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of 250 ltr capacity all as specified and directed. |
| 74 | S & F in replacement Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of 500 ltr capacity all as specified and directed. |
| 75 | S&F in replacement MS framed work such as grills, gratings etc with ends of bars shouldered or riveted of forged into spikes framed guard bars, barred iron doors, ladders, framed balusters , walking way, railing, framework of watertanks and similar work conforming to FE-290, Gde-165 including dismantling of existing wrought iron or mild steel work of any description all as specified and directed. |
| 76 | S&F in replacement hot water storage tank of capacity 100Ltrs per day with inner shell fabricated from stainless steel 1mm thick in cylindrical shape and outer cover fabricated from aluminium sheet 1mm thick(having insulation of rock wool) mineral wool 100mm thick & cladding with aluminium 26 SWG complete all as specified and directed.Make :- Supreme/V-guard. |
| 77 | S&F in replacementhot water storage tank of capacity 200Ltrs per day with inner shell fabricated from stainless steel 1mm thick in cylindrical shape and outer cover fabricated from aluminium sheet 1mm thick(having insulation of rock wool) mineral wool 100mm thick & cladding with aluminium 26 SWG complete all as specified and directed.Make :- Supreme /V-guard |
| 78 | M & L for servicing of semi automatic RO plant 500 Ltr per hr installed atOT including mono block pump sets of 0.5 H.P capacity - 02 Nos complete for trouble free operation by checking all parts, cleaning and backwashing of filter media of all units/ membranes, arresting of leakages and checking quality of water and keeping the plant in serviceable condition to provide the acceptable quality standard parameters as required all as specified by manufacturers and as directed.Notes: (a) Servicing shall be carried out through authorised service dealer of M/s ION EXCHANGE INDIA LTD or from any other authorised service dealer as approved.(b)Un-serviceable spares which are required to be replaced shall be measured and paid separately under relevant items. |
| 79 | M & Lfor replacement of 2x5 micron cartridge filterfor RO plant as per ser No 1 aboveincluding taking out existing unserviceable filter complete all as specified and as directed. |
| 80 | Supply & Fill antiscalent chemical for RO plant as per ser No 1 |
| 81 | Supply & Fill membrane cleaning chemical (6Kg/3month) forRO plant as per ser No 1 |
| 82 | Supply & Fillreplacement filtering sand fine for RO plant as per ser No 1 |
| 83 | S & Fin replacement Activated carbon filter for RO plant as per ser No 1 |
| 84 | S & F in replacement RO Membrane for RO plant as per ser No 1 |
| 85 | M & L forservicing of Water Softener plant 8000 ltrs Capacity , including mono block pump set of 2 HP capacity - 02 Nos complete for trouble free operation by checking of all parts , cleaning and backwashing of filetr media of all units/membranes , arresting of leakages andcheckingquality of water and keeping the plant in serviceable condition to provide the acceptable quality standard parameter as required all as specified by manufacure and as directed for the following plants. The Water treatment plant consist of the following:-Cholorine Dosing Unit- 01 NoIron media Filter (FRP) - 01 NoDual media Filter (FRP)-01 NoActivated Carbon Filtter - 01 NoSoftener (FRP) - 01 NoPHDosing Unit- 01 NoElectric Contol Panel - 01 No.Notes: Un-serviceable spares which are required to be replaced shall be measured and paid separately under relevant items. |
| 86 | ForPlantat OT PUMP HOUSE |
| 87 | ForPlant at Mechanical Laundry |
| 88 | S & F in replacement Multiport Crystal Valve 40 nbcomplete all as specified and as directed. |
| 89 | Supply & fillin replacement sand pebbles for water treatment plantincluding taking out existing unserviceable pebbles complete all as specified and as directed. |
| 90 | Supply & fillin replacement sand 6mm for water treatment plantincluding taking out existing unserviceable sand complete all as specified and as directed. |
| 91 | Supply & fillin replacement sand 4mm for water treatment plant including taking out existing unserviceable sand complete all as specified and as directed. |
| 92 | Supply & fillin replacement sand fine for water treatment plant including taking out existing unserviceable sand complete all as specified and as directed. |
| 93 | S & F in replacement carbon 900iv for water treatment plant including taking out existing unserviceable carbon complete all as specified and as directed. |
| 94 | S & F in replacement coconut burn carbon for water treatment plantincluding taking out existing unserviceable carbon complete all as specified and as directed. |
| 95 | S & F in replacement defouling resin 225 grade(ION Exchange) for water treatment plant including taking out existing unserviceable complete all as specified and as directed. |
| 96 | Supply only iodine free pure common salt crystal for water Softner plant complete all as specified and as directed. |
| 97 | M & L for dismantling of electric driven induction motor of capacity 1 HP 230 volt, single phase 50 HZ of RO plant,shifting to local work shop, taking out the burnt windings, cleaning of slots and rewinding the same with copper winding wire of existing gauge and quantity heating applying shellac varnish to the windings, replacing insulating materials as required baking up and assembling back including replacing the bearings bushes using hydraulic pressureall as specified and directed |
| 98 | M & L for dismantling of electric driven induction motor of capacity 2 HP 230 volt, single phase 50 HZ of RO plant, shifting to local work shop,taking out the burnt windings, cleaning of slots and rewinding the same with copper winding wire of existing gauge and quantity heating applying shellac varnish to the windings, replacing insulating materials as required baking up and assembling back including replacing the bearings bushes using hydraulic pressureall as specified and directed |
| 99 | Supply & Fixin replacement Ductile iron pipes, Class K-7, with spigot and socketed ends centrifugally cast (spun) with factory applied cement mortar lining inside the pipes and outside with zinc coating with suitable push on joint (Rubber gasket D joint) confirming to IS 8329/2000 of size 150mm bore and connected items complete all as specified and as directed. |
| 100 | S & Fin replacement water tubing 100 mm dia GI pipe , medium grade, galvanized, in trenchesor fixed on walls/ floors/ roofs etc with and including provision of all connected fittings completeall as specified and as directed. |
| 101 | All as per Item No 21 above but 50 mm dia GI pipe complete all as specified and as directed. |
| 102 | All as per Item No 21 above but 25 mm dia GI pipe complete all as specified and as directed. |
| 103 | S & F in replacement Gun metal gate valve, heavy duty, screwed both ends with iron wheel head suitable for50 mm bore GI water tubing including provision of necessary unions, nipple, collar etc. alongwith GI unions, nipple and collar including cutting the old threaded portion of GI pipe and making new threading in position complete all as specified and as directed. |
| 104 | All as per Item No 24 above but 25 mm bore complete all as specified and as directed.. |