| 1 | Checking and maintenance of street light, perimeter light and high mast light including accessories, LED lights fitting on wall or pole or high mast and of any other locations to find out defects including dismantling of defective parts or taking down the fitting if, necessary, cleaning the bowl/ perflex cover and making the fitting in 100% serviceable condition including rectification of fault of over head lines and under ground cables if, any complete all as specified and directed by Engineer-in-Charge.Note: (i) The Contractor shall deploy minimum 01 Elect and 01 Helper including sunday & holidays for the purpose from 0900 hrs to 1700 Hrs daily. (ii) All T&P/Safety items shall be provided by the contractor at his own cost.(iii) The Contractor shall rectify the complaint within 24 Hours otherwise penal charge will be imposed at the rate of Rs. 200/ per complaint/ per hour. (iv) Quoted rates shall include arrangement of bucket crane of high height or any other means required to rectify the compliants at the height of 11/18 metre or above. Safety of the tradesmen employed shall be the resposibility of the contractor. (v) Defective parts such as LED driver, service wire, cable joints shall be measured and paid under relevent item separately. However cost of replacement of minor parts such as nut, bolt, washer etc shall be inclusive in quoted rates. |
| 2 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan and not exc 1.5m in depth and getting in hard/dense soil complete all as specified and directed by Engr-in-charge |
| 3 | Returning filling in with approved excavated soil including spreading levelling watering and well ramming in layers not exceeding 25cm thick, complete, all as specified and directed. |
| 4 | Removing of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 5 | Burnt bricks sub class \"B\" laid flat dry across the cable for cable protection all as specified and directed. |
| 6 | Sand cushioning to UG cable 8cm thick before laying the cable and 15cm above the cable, stretching and testing of cable complete all as specified and directed. Note:(i) Consolidated / Punned sand shall be considered for purpose of payment (ii) Sand shall be same as specified for plastering work. |
| 7 | Double walled corrugated HDPE duct pipe of 40 mm inner dia confirming to IS:14930 (Part-II) of approved colour with fittings for cable protection complete all as directed. |
| 8 | Supply and fixing and replacement GI pipe, light grade 40 mm bore, ISI Marked for protection to cable along the pole/across road crossing/passing through culvertcomplete all as specified. |
| 9 | Supply and fixing in repairs straight through(Heat shrinkable) joint kit suitable for 1.1 KV UG XLPE cable of size 10 to 70 Sqmm 3.5 core. |
| 10 | M&L for anti-climbing device, spikes type fabricated out of MS bars (round,square and flat) including nuts, bolts, washer and welding in two halves made to shape to suit the cross section of the pole. |
| 11 | Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 25 Sqmm 3.5 core complete all as specified and directed. |
| 12 | All as per item No. 10 here-in-before but for cross sectional area 16 Sqmm 4 core complete. |
| 13 | All as per item No. 10 here-in-before but for cross sectional area 10 Sqmm 4 core complete. |
| 14 | All as per item No. 10 here-in-before but for cross sectional area 16 Sqmm 2 core complete. |
| 15 | Supply and fixing in replacement aluminium extruded energy efficient 30W inverter RTC street light with inbuilt RTC for auto ON/OFF & must have diming facility from 10 to 100 %, IP66 ingress protection having inbuilt Li-ion battery of 5200mAH LED . |
| 16 | Dismantling of unserviceable steel tubular/PCC poles any size and removal from site complete all as specified and directed |
| 17 | Supply and erecting steel tubular swaged type pole 410 SP 31 (9 mtr long) including foundation complete with cast iron /MS base plate of size 300mmx300mmx6mm continously welded at the centre of the pole and MS cap at the top of the pole all as specified including factory painted with two coats of black bituminous paint internally throughout and externally for embedded portion and applying of two coats of aluminium paint over a coat of red oxide primer above 1.5 mtr from GL and making of size 30 cm wide of black and white synthetic enamel paint alternately upto 1.5 m from ground level complete all as specified and directed. |
| 18 | Supply & fixing in replacement PVC junction box of size 168 x 253 x 115 outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable / wire complete comprising with the followings :- (a) Bus bar with two aluminium strips 100 Amps capacity insulated with insulators, including colour coding and control wiring from bus bar to MCB (b) MCB SP 6 Amps - 01 No. Make of MCB: ABB/Havells/Legrand (c) clamp made out of 25mm x 3mm flat iron duly welded with nuts & bolts complete all as specified and directed. |
| 19 | Supply & fixing in replacement bracket made out of GI light grade pipe of 32 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 25mm x 4mm and 04 sets of nuts, bolts and washers including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed. |
| 20 | Supply and fixing in replacement LED flood light 210 watt 230 V AC outdoor type with thermal management inmultiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including providing necessary connections with 3 core 1.5 Sqmm stranded PVC insulated copper conductor cable upto 3 metre length complete all as specified and directed. |
| 21 | Supply and fix in replacement post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 22 | Supply and fixing in replacement LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including connection with 3 core 1.5 sqmm copper conductor cable from junction box / over head line complete. |
| 23 | Supply and fixing in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including connection with 3 core 1.5 sqmm copper conductor cable from junction box / over head line complete. |
| 24 | Supply and fixing in replacement LED solar light fitting 24 Watt including galvanized steel pole (6RM LONG) in built, lithium ion battery, solar panel charge controller with dusk down sensor comlete all as specified and directed. |
| 25 | Supply & fixing in replacement of sheet metalenclosure Time switch astro type 110 - 240 VAC single Phase - 4W 3 Channel, Base/DIN, 240 volt 16 amp rating with contactor 2 pole 240 Volts 63 Amp - 01 No, MCB SP, 240 volts 0.5 Amp01 No and MCB DP, 240volts 10 Amp 01 No Make : L&T/Legrand/Siemens,fixed in CPRI approved sheet metal enclosure 2 mm thick of size 40x40x10 cm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and fixing arrangements by means of 25 mm x 3 mm MS flat clamps, nuts, bolts and washers complete all as specified and directed by Engr-in-charge. |
| 26 | M&L PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation of electric poles, struts PCC blocks and fair finish to exposed surfaces without using extra cement etc complete all as specified. |
| 27 | M&L PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of electric poles, struts PCC blocks and fair finish to exposed surfaces without using extra cement etc complete all as specified. |
| 28 | PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole, including necessary form work complete all as specified and directed |