State Plan-Construction Of Quality Control Division Kozhikode Office Building Under Existing Jica Oh Tank, Malaparamba-Civil & Electrical Works-State Plan-2024-2025-General Civil Work
Tender Overview
Project Description
State Plan-CONSTRUCTION OF QUALITY CONTROL DIVISION KOZHIKODE OFFICE BUILDING UNDER EXISTING JICA OH TANK, MALAPARAMBA-CIVIL & ELECTRICAL WORKS-State Plan-2024-2025-General Civil Work
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 26-Sep-2024 | DATE | Date | 09-Oct-2024 |
BOQ
| Sl. No. | Item Description |
| 1 | Construction of Quality Control Division offfice near Quality Control District lab,Kozhikode |
| 2 | OD101888/2024-2025:Dismantling and Refiting GI / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge |
| 3 | OD101889/2024-2025:Shifting carefully the existing specials such as valves, rubber bushes, etcto the adjacent partitioned room under the same JICA tank without damaging materials as per the direction of departmental officers. |
| 4 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 5 | 11.3.1:Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 6 | 11.41.1:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm. |
| 7 | 11.40:Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete. |
| 8 | 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). |
| 9 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 10 | 50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. |
| 11 | 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. |
| 12 | 13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). |
| 13 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 14 | 21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 15 | 21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 16 | 21.3.3:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness |
| 17 | 21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness |
| 18 | 9.117.1:Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer\"s specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm |
| 19 | 9.120.1:Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture.M.S. frame covered with 5 mm thick heat moulded PVC \"C\" channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flatand 20 mm shall be tapered on both sides to form lock rail.Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the \"C\" Channel using PVC solvent adhesive etc.complete as per direction of Engineer -in-charge, manufacture\"s specification & drawing.30 mm thick plain PVC door shutters |
| 20 | 9.81.1:Providing and fixing bright finished brass handles with screws etc. complete:125 mm |
| 21 | 100.41.40:Supply, stacking, spreading and consolidating of Red earth in the trench of pipe line for cushion including carriage, loading, unloading & stacking up to any lead. |
| 22 | 13.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 23 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 24 | 14.53.1:Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work |
| 25 | 21.2.2:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides |
| 26 | 9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 27 | 14.54.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work |
| 28 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 29 | 21.13:Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete |
| 30 | 21.16.3:Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Polyester powder coated minimum thickness 50 micron aluminium |
| 31 | OD101890/2024-2025:Providing and fixing good quality roller blind curtains of the color of blue/ivory/ash/brown of equivalent color as per the direction of the engineer in charge. The cost includes labor, material all other incidental charges if any. |
| 32 | Provision for Water tank & Plumbing work |
| 33 | OD101931/2024-2025:Providing and fixing rectangular high density polyethylene water storageloft tank with cover, conforming to ISI : 12701, colour of opaque white or asapproved by Engineer-in-charge. The rate includes making necessary holesfor inlet, outlet & over flow pipes. The base support i/c fittings & fixtures fortank shall be paid separately. |
| 34 | 100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. |
| 35 | 50.18.9.12.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 10Kgf/cm2 External work- Exposed on wall |
| 36 | 50.18.9.14.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall |
| 37 | 50.18.9.16.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall |
| 38 | 100.9.5:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 50 mm nominal outside diameter pipes. |
| 39 | 100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes. |
| 40 | 100.98.233:Supply of PVC Pipe, 10kg/cm2, 50mm Dia. |
| 41 | 100.98.237:Supply of PVC Pipe, 10kg/cm2, 110mm Dia. |
| 42 | 17.7.5:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap |
| 43 | 17.3.1:Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 44 | 17.35.1.1:Providing and fixing soil, waste and vent pipes:100 mm diaSand cast iron S & S pipe as per IS : 1729 |
| 45 | 100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals. |
| 46 | Electrification works |
| 47 | OD101891/2024-2025:Supply of 1x20 W LED box type tube fittings. The fittings shall be made from CRCA MS sheet of minimum thickness 0.50 mm nominal thickness inside & outside (including LED Tube) MR1163 |
| 48 | OD101892/2024-2025:Supplying and fixing following rating, double pole, ( phase and neutral), 230 volts,residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps( DAR 2.15.1) |
| 49 | OD101893/2024-2025:Supplying 300/305 mm sweep light duty exhaust fan working on 230 V AC |
| 50 | OD101894/2024-2025:Conveyance, installation , testing and commissioning of exhaust fans of size up to450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as requiredincluding giving connections with the supplied wire along with the exhaust fan. |
| 51 | OD101895/2024-2025:- Charges for cutting holes suitable for accommodating exhaust fans above 305mmsweep and up to 450mm sweep including plastering colour washing etc. as required. |
| 52 | OD101896/2024-2025:Supply, conveyance, installation, testing and commissioning of ceiling fans of thefollowing sizes using standard accessories excluding resistance type regulator, wiring the downrod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copperconductor flex wire or with extended original wiring etc. as required. : 1200mm sweep -5star rated BLDC ceiling fan complete with 300mm down rod , canopies, shacklesand blades working on 230V/240V single phase A/C |
| 53 | OD101897/2024-2025:Supply, conveyance, installation, testing and commissioning of wall fans of the following sizes using standard accessories with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. : 400mm size - working on 230V/240V single phase A/C |
| 54 | OD101898/2024-2025:Installation, testing and commissioning of pre - wired, fluorescentfitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc.directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copperconductor, single core cable and earthing etc. as required. |
| 55 | OD101899/2024-2025:2.13.1. Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 56 | OD101900/2024-2025: Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,"C" curve, miniature circuit breaker suitable for inductive load of following poles inthe existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 57 | OD101901/2024-2025:- Supplying and fixing two module stepped type electronic fan regulatoron the existing modular plate switch box including connections but excluding modular plate etc.as required. |
| 58 | OD101902/2024-2025: Supplying and fixing modular blanking plate on the existing modularplate & switch box excluding modular plate as required. |
| 59 | OD101903/2024-2025:Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm) |
| 60 | OD101904/2024-2025:Supplying and fixing suitable size GI box with modular plate and cover in FRLSonton surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modularsocket outlet and 15/16 amps modular switch, connection etc. as required. |
| 61 | OD101905/2024-2025:1.27.2. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm). |
| 62 | OD101906/2024-2025:Supplying and fixing 3 pin, 5 amp ceiling rose on the existingjunction box/ wooden blockincluding connection etc as required. |
| 63 | OD101907/2024-2025:Supplying and fixing PVC batten/ angle holder with 15W LED bulb including connectionetc. as required. |
| 64 | OD101908/2024-2025:Supplying and fixing following ways 230 volts ,TPN MCB Distribution Board of sheet steel,dust protected,duly powder painted,inclusive of 200amps tinned copper bus bar,common neutral link,earth bar,din bar for mounting MCB's(but without MCB's and incomer) as required . 4 way ,double door |
| 65 | OD101909/2024-2025:Supplying and fixing following modular switch/ socket on the existingmodular plate & switch box including connections but excluding modular plate etc. asrequired. 3 pin 5/6 amp socket outlet |
| 66 | OD101910/2024-2025: Supplying and fixing following modular switch/ socket on the existingmodular plate & switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch |
| 67 | OD101911/2024-2025:Supplying and fixing of following sizes of medium class PVC conduitalong with accessories in surface/ recess including cutting the wall and making good the samein case of recessed conduit as required. 25 mm |
| 68 | OD101912/2024-2025:Supplying and fixing of following sizes of medium class PVC conduitalong with accessories in surface/ recess including cutting the wall and making good the samein case of recessed conduit as required. 20 mm |
| 69 | OD101913/2024-2025:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable in surface / recessed medium class PVC conduit, 2 waymodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required. |
| 70 | OD101914/2024-2025:Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessedmedium class PVC conduit,with modular switch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc asrequired.Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium classPVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.-Group C |
| 71 | OD101915/2024-2025:1.14.1. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire. (as per DAR Electrical) |
| 72 | OD101916/2024-2025:5.3. Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.Header Unit set Header Quantity 1.0 Header Details Details of cost for one Set MATERIALMaterial M2915 600 mm X 600 mm X 6 mm thick G.I. plateeach 1.0 1438.0 1438.0 M12825 20 mm dia. G.I.Pipe (medium class)= 2.70 + 0.14 (Wastage @ 5%) = 2.84mmetre 2.84 111.0 315.24 M22922 CI/MS cover plate hinged to FRL Same with Locking arrangementeach 1.0 277.0 277.0 M32918 Funneleach 1.0 19.0 19.0 M42919 G.I. nuts and through bolts with washereach 1.0 26.0 26.0 M52945 Common burnt clay F.P.S. (non modular) bricks class designation 7.5each 50.0 4.0 200.0 M62948 Cementtonne 0.01 6300.0 63.0 M72946 Fine sandcum 0.03 806.0 24.18 M8Labour L1001 WiremanDay 0.5 673.0 336.5 L11007 KhallasiDay 0.5 553.0 276.5 L21010 Mason, Grade 2Day 0.2 612.0 122.4 L31012 Beldar/coolieDay 1.45 553.0 801.85 L4TOTAL 1.0 set 3899.67 UNIT TOTAL 1 set 3899.67 |
| 73 | OD101917/2024-2025:5.9. Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 74 | OD101918/2024-2025:90.12.7.41. Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 16 sq mm with factory made clamp |
| 75 | OD101919/2024-2025:Supplying siemens/ tropdur type nickel <br>plated Double compression brass cable <br>gland for PVC insulated and PVC sheathed <br>armoured Aluminium/copper conductor <br>cable 1.1KV grade ,and making end term- <br>ination suitable for following cable 4 core <br>16 mm <br>Code Description Unit Quantity Rate Amount RemarksMR . No 1.00000 400.00 400.00 TOTAL 400.00cost for one No 400.0Say 400.0 |
| 76 | OD101920/2024-2025:90.16.1.4. Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4.00 mm copper conductor ( 8 SWG) |
| 77 | OD101921/2024-2025:1.14.2. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 78 | OD101922/2024-2025:1.24.5. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet |
| 79 | OD101923/2024-2025:1.23.3. Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required. 15/16 amp switch |
| 80 | OD101924/2024-2025:Supplying and fitting 9W/12W LED bulb |
| 81 | OD101925/2024-2025:90.4.1. Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. Header Unit each Header Quantity 1 Header Details COST FOR 1 EACH A1 MATERIALS Material M MR2076 M.S rod type fan clamp for R.C.C. slab neatly painted with one coat of red oxide primer and two coats of enamel paint set 1 36.02 36.02 M12948 Cement tonne 5.00E-04 6300 3.15 M22946 Fine sand cum 0.003 806 2.42 M3Labour L1010 Mason, Grade 2 Day 0.07 612 42.84 L1 MR704 Man Mazdoor Day 0.07 675 47.25 L2Additional Charges Ltcode Hire charges for T & P @ 2% of :(M1+M2+M3+L1+L2) L.S 2.63 A6TOTAL 1 each 134.31 UNIT TOTAL 1 each 134.31 |
| 82 | OD101926/2024-2025:90.5.1.3. Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required. Ding dong bell Header Unit each Header Quantity 1 Header Details COST FOR 1 EACH Material M MR1131 Ding dong bell each 1 101.69 101.69 M1Labour L1001 Wireman Day 0.04 673 26.92 L1 MR719 Wireman Helper Day 0.04 600 24 L2Additional Charges Ltcode Hire charges for T & P @ 2% of :(M1+L1+L2) L.S 3.05 A4TOTAL 1 each 155.66 UNIT TOTAL 1 each 155.66 |
| 83 | OD101927/2024-2025:1.23.6. Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required. Telephone socket outlet Header Unit each Header Quantity 1 Header Details Details of cost for one each MATERIAL Material M1437 Telephone Socket outlet piano type each 1 20 20 M1Labour L1001 Wireman Day 0.03 673 20.19 L11007 Khallasi Day 0.03 553 16.59 L2TOTAL 1 each 56.78 UNIT TOTAL 1 each 56.78 |
| 84 | OD101928/2024-2025:1.53.1. Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required 1 run of Cable Header Unit metre Header Quantity 50 Header Details COST FOR 50 METERS MATERIALS Material M1451 UTP 4 Pair CAT 6 LAN Cable per metre 51.5 24 1236 M1Labour L1001 Wireman Day 0.5 673 336.5 L11007 Khallasi Day 0.5 553 276.5 L2TOTAL 50 metre 1849 UNIT TOTAL 1 metre 36.98 |
| 85 | OD101929/2024-2025:1.53.2. Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required 2 run of Cable Header Unit metre Header Quantity 50 Header Details COST FOR 50 METERS MATERIALS Material M1451 UTP 4 Pair CAT 6 LAN Cable per metre 103 24 2472 M1Labour L1001 Wireman Day 0.5 673 336.5 L11007 Khallasi Day 0.5 553 276.5 L2TOTAL 50 metre 3085 UNIT TOTAL 1 metre 61.7 |
| 86 | OD101930/2024-2025:Supplying, testingand commissioning 2KVA/72VDC online sine wave UPS single phase in put and single phase out put 50HZ microprocessor control system/digital signal processor LCD display and other necessary specifications.1 Nos Battery of 12v/200AH with inter connecting nut bolts and metalic battery stand. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender