| 1 | LAN |
| 2 | OD131255/2024-2025:Supply, installation, testing and commissioning of 8 port L2 smart managed gigabit switch with 8 x 10/100/1000 BASE-T ports and 2 x SFP ports etc. supplied with all necessary accessories Preferred Make: D Link DGS-1210-10 or equivalent |
| 3 | OD131364/2024-2025:Supply and installation of UL listed, ETL verified 1U , 24 port Rack mountable Enhanced Modular type unloaded Patch Panel with rear cable organizer made ofcold rolled steel, powder coated, front labelling Facility and suitable for RJ 45 CAT 6/CAT6AKeystones and labelling as required. Preferred make: Molex, Honeywell, Commscope,Norden |
| 4 | OD131365/2024-2025:Supply, termination, testing, and commissioning of UL Listed,ETL verified CAT 6Keystone Jackwith dust protection, suitable for22- 24 AWG bare copper conductor,Minimum 500 insertion cycles and100 reterminations,as per TIA/EIA 568-B colour codeconforming tothe standards ANSI/TIA-568.2-D , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint. Preferred make: Molex, Honeywell, Commscope Norden |
| 5 | OD131256/2024-2025:Supply, installation, testing, and commissioning of UL Listed, ETL verified 0.5 meter CAT 6 UTP Patch Cordhaving LSZHjacket,24 AWG bare copper conductor UTP 4 pairboth end factory Crimped with modular male plugs with minimum 500 insertion cycles terminiated as per TIA/EIA 568-B colour codeconforming tothe standards ANSI/TIA-568.2 , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint. Preferred Make: Molex, Honeywell, Commscope, Norden |
| 6 | OD131257/2024-2025:Supply, installation, testing, and commissioning of UL Listed, ETL verified 2 meter CAT 6 UTP Patch Cordhaving LSZHjacket,24 AWG bare copper conductor UTP 4 pairboth end factory Crimped with modular male plugs with minimum 500 insertion cycles terminiated as per TIA/EIA 568-B colour codeconforming tothe standards ANSI/TIA-568.2 , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint .Preferred Make: Molex,Honeywell, Commscope,Norden |
| 7 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 8 | OD131366/2024-2025:Supply, installation, testing, and commissioning of Modular Wallplate with ABS plastic body, laoded with UL Listed,ETL verified single CAT 6Keystone Jack, suitable for22- 24 AWG bare copper conductor,Minimum 500 insertion cycles and100 reterminations,as per TIA/EIA 568-B colour codeconforming tothe standards ANSI/TIA-568.2-D , ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,and RoHS Complaint , spring shutter front access, Protected labelling ,etc on existing 75 mm X 75 mm X 60 mm deep metal/PVC box on surface or in recess as required .Preferred Make: Molex, Commscope Honeywell |
| 9 | OD131272/2024-2025:Supply and installation of 1 KVA offline UPS with 2 Nos of 7 Ah Battery . Preferred Make: Hykon, Numeric |
| 10 | OD131258/2024-2025:Supply and fixing of 19 inch 6U wall mountable rack with covered cable manager, power strip with minimum 4 numbers of sockets, cooling fan ,lockable front door ,with glass panel etc. Preferred make: Netrack ,Valrack, D Link |
| 11 | Cabling |
| 12 | OD131259/2024-2025:Supply, drawing. testing and commissioning of UL certified and ETL verified 23 AWG bare copper conductor UTP 4 pair Unarmoured CAT 6 cable with HDPE Insulation Material and LSZH Outer Jacket, conforming to thestandards ANSI/TIA-568.2-D, ISO/IEC 11801, IEEE 802.3, ISO/IEC 60332-1,ISO/IEC 61034-2,ISO/IEC 61754-2,Colour Code as per TIA/EIA 568-B, RoHS Compliant,transmission performance tested upto 500 MHz or better and Insertion Loss/ Attenuation: 33 dB/100m or better at 250 MHzin the existing conduit as required. Preferred Make :Molex,Honeywell, Commscope, Norden |
| 13 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 14 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |