| 1 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles, stays etc not exceeding 10 Square metre on plan and getting out in hard/dense soil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and as directed |
| 2 | All as per item No. 1 above but excavation depth exceeding 1.5 metre and not exceeding 3.0 metre. |
| 3 | Returning filling, including spreading levelling, watering and well ramming in layers not exc 25 cms thick of soil complete all as specified and directed. |
| 4 | Removing the surplus excavated material/soil to a distance not exc 50 mtrs and depositing, where directed at a level not exceeding 1.5 mtrs above the starting point all as specified and directed. |
| 5 | Material and labour for Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed.Note:- Punned thickness 18cm shall be measured for payment purposes. |
| 6 | M & L forunreinforced precast concrete cable cover class HV type-I of size 300x180x40mm factory madelaid in perpendicular to the cable abutting each other all as specified and directed at site. |
| 7 | S&F 80mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,including taking out old tubing complete all as specified and as directed. |
| 8 | Dismantling and Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug,bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) conforming to IS-1678 and including marking alternate 05 Nos white and black strip 30cm height with two coats of synthetic enamel paint including preparation of surfaces, upto 1.5 metre above the coping of pole, starting with black strip, including dismantling and taking down of old unserviceable steel tubular HT pole complete all as specified and directed.Note: Excavation and earth wok and PCC for foundation, channel, clamps nuts, bolts to be measured and paid separately. |
| 9 | Material and labour for plain cement concrete 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation filling and mass concrete, complete, all as specified and as directed. |
| 10 | Material and labour for plain cement concrete 1:3:6 type C-1 (using 20 mm graded mechanically crushed stone aggregates) as in fixing of hold fast, coping of pole and strut, bed plates and the like,finishing the surface fair and even, including necessary form work, complete, all as specified and as directed. |
| 11 | M&L Plain cement concrete 1:2:4, Type B-1 by using 20 mm graded granite stone aggregate in copingincluding necessary form work and finishing exposed surfaces fair & even complete all as specified and as directed. |
| 12 | Supply & Erecting 2 pole structure on 11 meter steel tubular swagedpole SP-55 consisting of pole with anti-climbing device, including PCC foundation of 1:3:6 & cross arms, MS channel,clampetc for one incoming and one out going,with 2 coat silver animal colour paint and marking the number on eachstructure. |
| 13 | Supply & Erecting 4 pole structure on 11 meter steel tubular swagedpole SP-55 consisting of pole with anti-climbing device, including PCC foundation of 1:3:6 & cross arms, MS channel,clampetc for one incoming and one out going,with 2 coat silver animal colour paint and marking the number on eachstructure. |
| 14 | Material and labour in replacement of lightning arrester expulsion type, suitable for 11000 Volt, with all fittings, trasmission class, discharge capacity 65 KA including connecting with HT line and dismantling and taking down of old unserviceable lightning arrester complete all as specified and as directed |
| 15 | Material and labour for aluminium conductor steel reinforced (ACSR) weasel/rabbit conductor from 66 KV sub station and other areas, including fixing, stretching on poles and proper noseling with binding wire to insulator of any size on 11 KV OH line as required at site and dismantling and taking down of old unserviceable ACSR conductor complete all as specified directed |
| 16 | Dismantling and taking down of old unserviceable cross arms, clamps, bracing, ms channeletc. of any section from pole including nuts, bolts, washers and cutting of bolts (slag bolts) if required complete and material and labour for cross arm bracing supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling hole for bolts in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide primer complete, all as specified and as directed |
| 17 | Supply and fixing of pin type, polymer, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65 mm dia for 11000 volts complete all as specified and directed. |
| 18 | Supply and fixing disc type insulators, porcelain, vitreous 145 mm height and 255 mm dia ball and socket type, white, brown or green disc, \"Two-in-series\" assembly for tension with tension clamps for conductor, working pressure 11000 volts grade, and dismantling and taking down of old unserviceable insulators complete all as specified and as directed. |
| 19 | Taking out old GOD and Supply, installing, testing and commissioning of air break gang operated triple switch (GOD) outdoor type, vertical mounting type of capacity 200 Amp with drop out fuse consisting 12 insulators,ISI marked mechanically operated, mounted on insulator and frame work with operating GI rods and mechanical work from ground level with locking arrangement including Godrej pad lock with two keys complete with fuse carrier and HT fuse element having upto 200 Amp rating suitable for HT 11 KV 50 HZ AC supply including necessary electric connection and dismantling and taking down of old unserviceable GOD complete all as specified and directed.. |
| 20 | Supply and fixing of stay assembly complete with all accessories such as stay plate300mmx300mmx6mm, stay rod 20 mm dia and 215cm long threaded end with nuts including 14mm dia GI stay bow. turn buckle, etc. complete, all as shown in Electrical plate No 1 of SSR part I 2009 complete including dismantling and taking down of old unserviceable stay assembly all as specified and as directed. Note :-The quoted rate shall include the cost of stay clamps,stay wire, stay bow, turn buckle, nuts etc whereas excavation and PCC work shall be measured and paid separately. |
| 21 | Supply and fix loop type insulator vitreous,porcelain white , brown or green of size 65x90mm , clearance of hole 16 mm complete all as specified. |
| 22 | Supplying and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cables (Heavy duty) with aluminium conductor, 11000 Volts grade, cross sectional area 95 Sqmm 3 core, suitable for 11 KV earthed system confirming to IS 7098 Part - 2 for insulation and for conductors Class 2 to IS 8130 - 84, in trenches, floors, ducts passing through pipe for road crossing etc,including connecting & testing and disconnecting and taking down of old unserviceable HT cable complete all as specified and directed.(Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured &paid for separately) . |
| 23 | Supplying and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cables (Heavy duty) with aluminium conductor, 11000 Volts grade, cross sectional area 120 Sqmm 3 core, suitable for 11 KV earthed system confirming to IS 7098 Part - 2 for insulation and for conductors Class 2 to IS 8130 - 84, in trenches, floors, ducts passing through pipe for road crossing etc,including connecting & testing and disconnecting and taking down of old unserviceable HT cable complete all as specified and directed.(Note : Excavation, earth work, brick protection, sand cushioning and GI pipe etc shall be measured &paid for separately) . |
| 24 | Material and Labour for preparation of old painted surfaces ofindoor/outdoor type transformers body, HT/LT duct and HT Panel board ,CT PT meter panel board at various substations for painting and applying one coat of spray paint with synthetic enamel paint of approved without distributing/damaging the electrical network system /equipmentall as specifed and directed. |
| 25 | Supply and fixed in repairs Danger notice plate of size 25 cm x 20 cm x 1.60 mm thick,mild steel sheet, vitreous enameled white, with letters, figures and conventionalskull & bones in signal red colour and fixed with MS clamps made out of 25 mm x 3mm MS flat iron including bolts and nuts of approved size for HT 11000 voltscomplete all as specified and directed. |
| 26 | Taking out old unserviceable earthing material and provision of new earthing complete galvanised earth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 25x4 mm GI strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm dia (light grade) and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm dia GI pipe (light grade) for watering and 40mm GI protection pipe, funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion. Note : The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire wesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. |
| 27 | Supply and spreding graded crushed stone aggregate 40mm size surrounding transformer two pole/ four pole structure/HT LT panel in 15 cm thickness after cleaning area byremoving existing wild grass,vegetation,creepers, small plants / bushes etc complete all as specified and directed. |
| 28 | Supply and fix in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm to 120 sqmmand testing complete all as specified and directed. |
| 29 | Disconnecting the HT & LT connections of existing Indoor/Outdoor/canopy type transformers of upto 400KVAcapacitymounted on 2/4 pole structure/plinth substation and transport to factory from site/power house/AGE B/R-II Yard for repair and back to site/power house/AGE B/R-II Yard after necessary repair/replacement of defective parts including installation in the same location and testing complete all as specified and directed. Note: (a) The quoted rate quoted for the item includes the following :- (i) Arrangement of manpower, tools and plants, crane and Recovery vehicle for transportation and shifting of transformer to work shop and back.(ii) Topping up of transformer oil, replacement of transformer oil as required basis under intimation to the department.(Transformer oil will be measured and paid seperately). (iii) Winding material shall be measured and paid separately under respective items. (iv) Re-winding of transformer and replacement of defective parts will be carried out only after inspection and recommendation of BOO.(Rewinding of Transformer will be paid separately).(v) welding to the any leakage part transformer (vi) Any damage occurred to transformer during the process of disconnecting/taking down/transportation,shall be made good by the contractor to the entire satisfaction of the Engr-in-Charge at his own expenses. |
| 30 | M & L for dehydration /filtration of transformer oil in existing pole mounted/floor mounted transformer / Voltage stabilizerwith the help of dehydration/filtration machine to achieve the dielectric strength of transformer oil not less than 50 KV complete. Note:-(i) Dehydration/filtration machinewill be arrange by the contractor and hewill make his own arrangementand to carry the machine at various sub stations including vehicle and towing arrangement.Therate shall be inclusive at above.(ii) Filtered oil should be with stand for one minute on voltage applied 50 KV at 4mm gap(iii) Test result will be recorded before and after filtration of oil. |
| 31 | Supply and pouring in replacement new transformer oil type EHV as per IS : 335 (Latest revision)for transformers installed at various site or in repair for topping up after dehydration to achieve the di electric strength 60 KV at 2.5 mm gap, complete all as specified and as directed by Engr-in-Charge.Note :-(i) Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge, Container shall be deposited by the contractor to the deptt, which will be returned after completion of conract.(ii)Wastage of burnt oil shall be considered as 30% of total oil and 70% qty of total oil shall be considered in schedule of credit. Make:- POWER LINK, POWER OIL, SAVITA,ELECTRO |
| 32 | LT bush rod of brass of suitable size of existing make and type with 5 nuts washers rubber washers etc suitable for transformer rating upto 400KVA complete, all as specified and directed by Engr-in-Charge. |
| 33 | Dry & blue colour silica gel crystal impregnated with cobalt suitable for transformer breather complete, all as specified and directed by Engr-in-Charge. |
| 34 | Taking out of existing defective oil outlet valve and providing new valve to suit the existing size made of gun metal for outdoor/indoor transformer of any capacity including rubber/leather gasket /packing as required/directed by Engr-in-Charge. |
| 35 | S&F in replacement of LT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformerupto 400 KVA |
| 36 | S&F in replacement of HT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer upto 400 KVA |
| 37 | Taking out the UNSV breather assembly complete form indoor/outdoor type transformer capacity upto 400KVA and supply and fixing the new breather assembly complete filled with fresh blue silica gel including connecting with proper rubberized gasket complete all as specified and directed by Engineer –in-cahrge |
| 38 | Charges for attendingcomplaint in respect of recce and rectification of fault in hight tension line (11 KV ) from PDD power grid khaltsi to lamayuru army area and made the HT linefunctional with replacement of major items shall be measured & paid under respective items as supply only. |
| 39 | Note for item no 38 :-(i) Contractor representative/ qualified electrician with helperfor High tensionlinewill report daily incl sunday and other holiday to complaint cell for morning and afternoon to collect routine/urgent nature of complaint related to Externalelectric supply till completion of contract. The work shall be attended by the contractor immediately. The contractor will ensure deployed of sufficientmanpower with all requisite to his trademanT&P with safety equipment for High tension linetype of requisite T&P items to his tradesman. the electrician recevied the complaint from complaint cell on job slip recee the Electline detect the fault and restore the line as soon as possible . In case of any delay in attending the complaint more than 12 hrs after handing over of routine / urgent works, the contractor shall be liable to pay the penalty as per the item rate.(ii) Contractor shall maintain the maintenance register showing all daily complaints received and shall maintain job card for attending complaints.(iii) If the Contractor did not attend complaints, a penalty of Rs 600/- per day per complaint recovery shall be made from the work done amount.(iv) The MES Department is not responsible for the payment of staff hired by contractor for complaint rates for attending the complaints by the electrician are deem to included in the item for repair i.e. Electrician/Helper, as all the items of CA are to be supply and fixed by the contractor.(v) All the complaint slip, register and connected document will be provided by the contractor without any extra cost.(vi) After any repair the site has to be cleaned and make the surface good. (vii) Cost of Vehicle for for attending the complaint and rectified same shall be included in quoted rate.(viii) Temporary restoration of power supply within four hours wherever feasible and complete rectification of fault within 12 hours. |
| 40 | Supply onlypin type, polymer, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100 voltscomplete all as specified and directed. |
| 41 | Supply only HT DO fuse element of rating upto 200 Ampscomplete all as specified and directed by Engr-in- Charge |
| 42 | Supplying only Tinned Copper fuse wire of16SWG to 22 SWG or 30 Amps to 200 Amps capacity(200Gmpacking) . |
| 43 | Labour only for removing the binding of ACSR conductor of HT 3 phase3 wire over head line from insulator, removing the jumper, connector, service wire, UG cable and restringing the existing ACSR conductor of any size, length, span upto desired sag and fixing the same ACSR conductor on insulator by proper binding, jumper connection etc complete all as specified and directed. |
| 44 | M & L for cradles guarding hexagonal/rectangular, fabricated wih galvanised steel wire 3.15 or 4 mm dia for 11 KV lineat road crossing , crossing over LT line and telecommunication line etc including taking down old cradles of any type, complete all as specified and directed. |
| 45 | Labour onlyfor taking out of inclind HT pole & repairing and refixing the sameas directed by Engr-in-charge.Note excavation, removal, PCC foundation etc shall be measured and paid as respective items. |
| 46 | Supply and fixing of triple spacer damper for maintaining separation in conductor and absorb the wind vibration suitable for triple conductor high tension line (11KV) . Note the quoted rateincludingnecessary ladder arrangement should be made by the contractor during replacing as required at site. |
| 47 | M&L for Cleaning, preparingand paintingwith 2 coat of super enamalled aluminium paint over one coats of red oxide primer to Steel tubular pole existing colour to cross arms, MS channels, angle iron, frame workbrackets \"D\" clamps andnumbering on poleall as directed by engg -in- incharge. |
| 48 | General Servicing toDiesel Engine Generating Set any type andmakeincluding checking all rubber/hose pipes, checking of coupling joints, v belts speed governor, air filter, filter elements valve tappet adjustments, radiator lines, leakage of coolant, oil including oiling/greasing & replacement of consumable parts such as minor items like nut/bolt, washers, gasket, welding works etc (included in unit rate) and replacement of worn out/unserviceable parts (to be measured separately as supply only) suitable for200 KVA capacity Silent DG set Make:-Kirloskar model No. 10E104563 and Supply only following consumable spares partsNOTE : Cost factor of labours for servicing & fixing of parts shall be deemed to be included in unit rate. However worn out & unserviceable parts to be replaced will be measured and paid separately as supply only. Make of spare partssame as of DG Set or as per sample. Servicing will be done as per manufacturer instructions.2x200KVA DG set at every 200 hrs servicing reqd.(Every three month service reqd i.e-3x2=06 Job) |
| 49 | Diesel filter |
| 50 | Lub Oil filter |
| 51 | By pass filter |
| 52 | Water seperator filter |
| 53 | Coolant filter |
| 54 | Air filter |
| 55 | Set of hose |
| 56 | Set of hose clamps |
| 57 | Set of fuel pipe |
| 58 | All as per Srl item No. 48.00 here-in-before but DG Set of capacity 160 KVA. Make:-CUMMINS model No. 6BTA-9-G13 and Supply only following consumable spares parts |
| 59 | Diesel filter |
| 60 | Lub Oil filter |
| 61 | By pass filter |
| 62 | Coolant filter |
| 63 | Air filter |
| 64 | Head Gasket |
| 65 | Half Packing kit |
| 66 | Set of hose |
| 67 | Set of fuel pipe |
| 68 | All as per Srl item No. 48.00 here-in-before but DG Set of cap 125 KVA. Make:-CUMMINS model No. 6BTA-9-G13and Supply only following consumable spares parts |
| 69 | Diesel filter |
| 70 | Lub Oil filter |
| 71 | By pass filter |
| 72 | Coolant filter |
| 73 | Air filter |
| 74 | Head Gasket |
| 75 | Half Packing kit |
| 76 | Set of hose |
| 77 | Set of hose clamps |
| 78 | Set of fuel pipe |
| 79 | All as per Srl item No. 48.00 here-in-before but DG Set of cap 100 KVA. Make:-CUMMINS model No. 84525941-14-G1and Supply only following consumable spares parts |
| 80 | Diesel filter |
| 81 | Lub Oil filter |
| 82 | Coolant filter |
| 83 | Air filter |
| 84 | Set of hose |
| 85 | Set of hose clamps |
| 86 | Set of fuel pipe |
| 87 | All as per Srl item No. 48.00 here-in-before but DG Set of cap 82.5 KVA. Make:-Kirloskar model No. 4H2501and Supply only following consumable spares parts |
| 88 | Diesel filter |
| 89 | Lub Oil filter |
| 90 | Air filter |
| 91 | Oil safety valve |
| 92 | Water safety valve |
| 93 | Fuel sensor |
| 94 | Set of hose |
| 95 | Set of hose clamps |
| 96 | Set of fuel pipe |
| 97 | All as per Srl item No. 48.00 here-in-before but DG Set of cap 50 KVA. Make:-Kirloskar model No. 06-2121900 and Supply only following consumable spares parts |
| 98 | Diesel filter |
| 99 | Lub Oil filter |
| 100 | Air filter |
| 101 | Head Gasket |
| 102 | Set of hose |
| 103 | Set of hose clamps |
| 104 | Set of fuel pipe |
| 105 | All as per Srl item No. 48.00 here-in-before but DG Set of cap 25 KVA. Make:-Crompton Greaves,and Supply only following consumable spares parts |
| 106 | Diesel filter |
| 107 | Lub Oil filter |
| 108 | Air filter |
| 109 | Set of hose |
| 110 | Set of hose clamps |
| 111 | Set of fuel pipe |
| 112 | M&L for calibration of fuel injection pump assemblyby authorised dealer with replacement of worn out parts, testing and commissioning complete including alignment, plunger, packing kit, spring delivery valve etc. required to make the pump serviceable of DG set of capacity 62.5 KVA to 100 KVA complete all as specified and directed by Engr-in-Charge. (The item rate includes transportation of pump from site to dealers workshop and back). |
| 113 | M&L for calibration of fuel injection pump assembly by authorised dealer with replacement of worn out parts testing and commissioning complete including alignment, plunger, packing kit, spring delivery valve etc. required to make the pump serviceable of DG set of capacity 125 KVA complete all as specified and directed by Engr-in-Charge. (The item rate includes transportation of pump from site to dealers workshop and back). |
| 114 | Material and labour for calibration of fuel injection pump assembly by authorised dealer with replacement of worn out parts testing and commissioning complete including alignment, plunger, packing kit, spring delivery valve etc. required to make the pump serviceable of DG set of capacity 160 KVA complete all as specified and directed by Engr-in-Charge. (The item rate includes transportation of pump from site to dealers workshop and back). |
| 115 | Material and labour for calibration of fuel injection pump assembly by authorised dealer with replacement of worn out parts testing and commissioning complete including alignment, plunger, packing kit, spring delivery valve etc. required to make the pump serviceable of DG set of capacity 200 KVA complete all as specified and directed by Engr-in-Charge. (The item rate includes transportation of pump from site to dealers workshop and back). |
| 116 | M&L for removing the radiator assembly after disconnecting from engine, opening the parts of radiator for servicing and repairing/ replacement of unserviceable minor parts including brazing/ welding complete of DG set of capacity 62.5 KVA to 100 KVA complete all as specified and directed by Engr-in-Charge. (The item rate includes transportation of radiator from site to workshop and back and refixing the radiator in position). |
| 117 | M&L for removing the radiator assembly after disconnecting from engine, opening the parts of radiator for servicing and repairing/ replacement of unserviceable minor parts including brazing/ welding complete of DG set of capacity 125 KVA to 200 KVA complete all as specified and directed by Engr-in-Charge. (The item rate includes transportation of radiator from site to workshop and back and refixing the radiator in position). |
| 118 | M&L for repair of self starter of 62.5 KVA to 100 KVA DG set including taking out burnt out winding, rewinding the same and replacement of burn out parts carbon brush, brushes etc complete all as specified and directed by Engr-in-Charge. (Note: The items rates incl transportation of self startor from site /store to workshop and back to site /store |
| 119 | S&F in repair self starter 12 volts suitable for62.5 KVA to 100 KVA DG set including taking out unsv self starter from the DG set complete all as specified and directed by Engr-in-Charge. |
| 120 | M&L for repair of self starter of 125 to 160 KVA DG set including taking out burnt out winding, rewinding the same and replacement of burn out parts carbon brush, brushes etc complete all as specified and directed by Engr-in-Charge.(Note: The items rates incl transportation of self startor from site /store to workshop and back to site /store.) |
| 121 | S&F in repair self starter 24 volts suitable for200 KVA DG set including taking out unsv self starter from the DG set complete all as specified and directed by Engr-in-Charge. |
| 122 | S&F in repair water Pump Assy of DG set of capacity 62.5 KVA to100 KVA complete all as specified and directed by Engr-in-Charge. |
| 123 | S&F in repair water Pump Assy of DG set of capacity 125 KVA to 200 KVA complete all as specified and directed by Engr-in-Charge. |
| 124 | Material & Labour for taking out fuel from fuel tank and keep in container for refilling after cleaning, cleaning of fuel tank of DG set of capacity25 to 200 KVA, removing sludge and sediments deposited inside the diesel tanks by washing with detergent washing powder and air compressor including testing for proper working, complete all as directed. |
| 125 | Repair of leakage/mixing of lub oil and coolent/Diesel of for DG set 100 to 200 KVA including body packing, gasket, oil seal,liner including as per requirement and complete connection of engine connections, testing and commissioning complete all as specified and directed. |
| 126 | Supply and fix in replacement of engine oil 5w30 suitable for DG set servicing/smooth functioningcapacity 25 KVA to 200 KVA including testing for proper working, complete all as directed. |
| 127 | Supply and fix in replacement of collent suitable for DG set servicing/smooth functioningcapacity 25 KVA to 200 KVA including testing for proper working, complete all as directed. |
| 128 | Excavation in trenches, getting out in hard/dense soil not exceeding 1.5m deep and not exc 1.5m wide for taking out the existing cable of poles etc any size at places complete all as specified and directed. |
| 129 | Removing of surplus soil to a distance not exceeding 50 mtr complete all as specified and deposited where directed at a level not exceeding 1.5m above the starting point all as specified. |
| 130 | Returning filing in including spreading levelling, watering & well ramming in layers not exceeding 25 Cm thick all as specified. |
| 131 | Material & Labour for sand cushioning 15 cm below and 8 cm above the U/G cable laid (total depth of sand shall be 18 cm) complete all as specified & directed by Engr-in-Charge. |
| 132 | M & L for providing PCC cable cover class LV type-I of size 250x140x40mm laid in perpendicular to the cable abutting each other all as specified and directed at site. |
| 133 | Supply and laying in replacement ofXLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size16Sq mm 4 core completeTrenches/ ducts all as directed. |
| 134 | M & L for GI pipe light grade 50 mm dia galvanised with all fitting to be laid in trench/wall/pole for the protection of cable under road/poles/wall/floor etc complete and PCC path complete all as directed by Engineer-in-charge . |
| 135 | Street light fitting service bracket complete with 1.2m long G.I pipe 25mm dia med grade,45 degree bending making fixing arrangements with angle iron clamp as per the steel tublar pole dia ,incl nuts bolts,washer and painting with one coat of red oxide and one coat of silver paints all as specifird and directed, |
| 136 | Supply and fixing hot pressure moduled SMC junction Box single door fixed with hinge of size 35x25x15cm,with closing arrangement with 10 Amp three phase and netural bus bar, internally wired nut bolts with suitable size of copper conductor and one No MCB SP 6 Amp mounted on din rail |
| 137 | Repair/Replacement Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised iron srip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. |
| 138 | Supply and fix replacement of High power LED street light 35/36 Watt IP 66 Energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driverof make Wipro or equivelent to Havells/ Phillips/ Bajaj incl suitable size service bracket fixed with clamps, nut, bolt and washer and electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated complete all as spfd. |
| 139 | Ditto but 60 Watt |
| 140 | S & F in replacement ofAluminium strip 25 x 3.15mm complete with saddles and fixing screws etc. for roof conductors and down conductors above ground upto test points. |
| 141 | Supply and fix in replacement of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw. |
| 142 | S& F in replacementofGI pipe Medium grade 40 mm dia galvanisedadded in pccblock for fixing air termination rod 12mm complete all as directed by Engineer-in-charge. |
| 143 | M&L for jointing and testing of straight through termination joint (heat shrinkable) suitablefor 3.5 core 11 KV(Earthed) underground XLPE cable including taking down existing unserviceable joint complete all as specified and as directed. |
| 144 | Supply and fix in replacement ofsingle pointed Air termination aluminum rod ,12mm dia 300 mm long |
| 145 | Supply and erection truely vertical position steel tubular swaged pole complete with cast iron base plate finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 mtr long) including painting with two coats of aluminium paint over one coat of red oxide primer, with black and white strips 30 cm each starting with black strip upto 1.5 mtr complete all as specified and as directed. |
| 146 | M&L for cement concrete type D2 1:4:8 (40mm graded aggregate) in pole/stay/ plinth etc infoundation filling completed all as directed by Engr-in-Charge. |
| 147 | M&L for cement concrete type C2 1:3:6 (40mm graded aggregate) incoppingof poles all as directed by Engr-in-Charge. |
| 148 | M&L for scrapping of old paint from the steel tubular pole upto 9.0 mtr height with out removing accessories and preparation of surface for re-painting. Repainting the pole with one coat of alternative white and black straps of 30cm upto 1.5 mtr height using synthetic enamel paint starting with black strap. repainting the remaining pole and iron parts i.e. U clamps, channels, etc above 1.5mtr height by applying one coat of aluminium paint and maintion pole no to all as required at site or directed. |
| 149 | M&L for Lightning conductor tightning of aluminium strip/air trrmination rod and GI strip proper secured to earthing with nut,bolt,washer and other material to all as required at site or directed. |
| 150 | Deduct Credit for Demolished/Dismantled material Rs (-) 92,520.00 (Minus) as listed in Schedule \"A\" Sec-II (Credit Schedule)Note :Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the \"Contract Sum\". |