| 1 | M&L for cleaning and servicing of Split Type 1.5/2.0 Ton Ton AC including repair of all loose electrical connections, abnormal noise in indoor/outdoor unit, foundation, power contactor etc including TOP UP of suitable gas complete all as specified and directed by Engg in charge.Note: Replacement of any spares will be measured and paid separtely. |
| 2 | M&L for cleaning and servicing of cassette type 4 Ton AC including repair of all loose electrical connections, abnormal noise in indoor/outdoor unit, foundation, power contactor etc including TOP UP complete all as specified and directed by Engg in charge. Note: Replacement of any spares will be measured and paid separtely |
| 3 | M&L for checking the leakage of Split type 1.5 Ton/2.0 Ton AC with the help of N2 Gas and after defecting and repairing the leakage, charge the sutiable refrigerant upto required level as specfied on the unit completeall as specified and directed by Engg in charge.Note: Replacement of capillary tube will be paid and measured seperately |
| 4 | M&L for checking the leakage of cassette type 4 Ton AC with the help of N2 Gas and after defecting and repairing the leakage, charge the sutiable refrigerant upto required level as specfied on the unit completeall as specified and directed by Engg in charge.Note: Replacement of capillary tube will be paid and measured seperately |
| 5 | S&F in repairs 1/2 inch copper pipe along with insulation material suitable for Split AC 1.5 Ton/2 Ton of existing/suitable make as per sample all as directed by Engg in Charge. |
| 6 | All as per Item No.5 above,but 1/4 inch copper pipe along with insulation material |
| 7 | All as per Item No.5 above,but5/8 inch copper pipe along with insulation material |
| 8 | All as per Item No.5 above,but Capacitor 45+/- 2 mfd |
| 9 | All as per Item No.5 above,butCapacitor 60+/-6 mfd |
| 10 | All as per Item No.5 above,but Capacitor 2.5 mfd |
| 11 | All as per Item No.5 above,butCapacitor 4 mfd |
| 12 | All as per Item No.5 above,butCapacitor 6 mfd |
| 13 | All as per Item No.5 above,butPanel Board of suitable make as per sample |
| 14 | All as per Item No.5 above,but Fan blade |
| 15 | All as per Item No.5 above,but Fan motor |
| 16 | All as per Item No.5 above,butCondenser coil unit complete |
| 17 | All as per Item No.5 above,butvalve of 1/2 or 1/4 or 5/8 |
| 18 | All as per Item No.5 above,butFlarry nut 1/4, 3/8, 5/8 and 1/2 |
| 19 | All as per Item No.5 above,butEvaporator Coil |
| 20 | All as per Item No.5 above,butIndoor motor |
| 21 | All as per Item No.5 above,butSwing motor complete of suitable size as per sample |
| 22 | All as per Item No.5 above,butSwing blade |
| 23 | All as per Item No.5 above,butRoom sensor |
| 24 | All as per Item No.5 above,butCoil sensor |
| 25 | All as per Item No.5 above,butDead plug of Brass Type |
| 26 | All as per Item No.5 above,butComplete Rewiring of Outdoor Split AC |
| 27 | All as per Item No.5 above,butUniversal Remote |
| 28 | S&F in repairs of Indoor Unit capacity 2 Ton complete set as per Sample and Existing Make complete all as directed by Eng-in-charge. |
| 29 | S&F in repairs of Outdoor Unit capacity 2 Ton complete set as per sample and Existing Make complete all as directed by Eng-in-charge. |
| 30 | S&F in repairs of Heavy duty compressor terminal Pin complete all as directed by Eng-in-charge. |
| 31 | S&F in repairs of Inlet water PVC pipe 20mm dia along with clamps complete all as directed by Eng-in-charge. |
| 32 | S&F in repairs of Flexible PVC pipe of 20mm dia as per sample complete all as directed by Eng-in-charge. |
| 33 | S&F in repairsCopper pipe along with insulation suitable for Cassette AC 4 Ton capacity of suitable make as per existing make/sample complete all asdirected by Engg in Charge. |
| 34 | All as per Item No. 33 above,but Capacitor 80-100 mfd |
| 35 | All as per Item No. 33 above,butBlower Motor |
| 36 | All as per Item No. 33 above,butBlower |
| 37 | All as per Item No. 33 above,butCooling Coil |
| 38 | All as per Item No. 33 above,butDrain Motor |
| 39 | All as per Item No. 33 above,butPCB Board for indoor |
| 40 | All as per Item No. 33 above,butSwing Motor |
| 41 | All as per Item No. 33 above,butDrain Motor Sensor |
| 42 | All as per Item No. 33 above,but Room Sensor |
| 43 | All as per Item No. 33 above,butCoil Sensor for indoor |
| 44 | All as per Item No. 33 above,butDrain Tray |
| 45 | All as per Item No. 33 above,butPCB Board for outdoor |
| 46 | All as per Item No. 33 above,butFan motor |
| 47 | All as per Item No. 33 above,butFan Blade |
| 48 | All as per Item No. 33 above,butCoil sensor for outdoor |
| 49 | All as per Item No. 33 above,butHP/LP Sensor |
| 50 | All as per Item No. 33 above,butCapacitor 10mfd |
| 51 | All as per Item No. 33 above,butContactor |
| 52 | All as per Item No. 33 above,butCondenser Coil |
| 53 | All as per Item No. 33 above,butSingle Phase Preventor |
| 54 | All as per Item No. 33 above,butvalve |
| 55 | All as per Item No. 33 above,butConnectors |
| 56 | S&F in repairs ofOutdoor unit Stand for fixing in wall complete all as specified and directed by Engg in Charge |
| 57 | Disconnecting the Electrical connection, removing the copper line, discharge line of Split AC 1.5/2.0 Ton capacity including indoor and outdoor units and all accessories and shifting,re-installing and testing the whole unit of Split AC in the same location and checking the leakage of Split type 1.5/2.0 Ton AC with the help of N2 Gas and after defecting and repairing the leakage, charge the sutiable refrigerant upto required level as specfied in suitable size and length of copper pipe and making the holes in wall complete all as specfied and directed by Engr in Charge |
| 58 | S&F in repairs of Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc complete all as specified for the following items with capacities of any make including necessary transport from units to work shop and back to units after repairs for Split Type AC 1.5 Ton capacity,complete all as directed by Eng-in-charge. Note 1: Rates deemed to be included for servicing, repairs and replacment of all connected parts, transportation of cooling appliances to work shop and back.Note 2: Rates deemed to be included for the gas required for charging |
| 59 | All as per Item No.58 above,butSplit Type AC 2.0 Ton capacity |
| 60 | All as per Item No.58 above,but Cassette type AC 4.0 Ton Capacity |
| 61 | Taking down existing Indoor & outdoor unit of cassette type of Make: Voltas and S & F the Indoor & outdoor unit complete Make: Voltas of capacity 4 Ton Model: 4 TR Venture Cassette and charge the N2 Gas to check the leakage and charge the suitable refrigerant upto required level as specified on the unit and test the complete AC for all the safety devices incorporated complete all as specified and directed by Eng- in charge |
| 62 | S&F in repairs of Modular Sheet metal single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 230 Volts of 25-32 Amps capacity complete all as directed by Eng-in-charge. |
| 63 | S&F in repairs of Plug Tops of 16 Amps complete all as directed by Eng-in-charge. |
| 64 | M&L for repairs of Split/cassette AC i.e water drain leakage problem detection and refitting the same in entire system including testing and commissioning complete serviceable for Split AC 1.5/2.0 Ton and Cassette type AC 4.0 Ton capacity complete all as directed by Eng-in-charge. |
| 65 | M&L Servicing to water coolers of 40/80 ltrs capacity including supply and charging of refrigerant R-134a/Suitable Refrigerant including cost of welding, leak detection, making good the defects in entire system, testing and commissioning ofall asdirected by Eng-in-charge. |
| 66 | S&F in repairs of Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc complete all as specified for the following items with capacities of any make including necessary transport from units to work shop and back to units after repairs of Water Coolers 40/80 Ltrs complete all as directed by Eng-in-charge.Note 1: Rates deemed to be included for servicing, repairs and replacment of all connected parts, transportation of cooling appliances to work shop and backNote 2: Rates deemed to be included for the gas required for charging |
| 67 | S&F in repairs of spares for Relay package assembly as per Existing Model for Water coolers of 40/80 Ltrs capacity complete al asdirected by Eng-in-charge. |
| 68 | All as per Item No.67 above,but Thermostat/cooling sensor complete unit |
| 69 | All as per Item No.67 above,but Capillary tube including filter/stainer |
| 70 | All as per Item No.67 above,but Condenser fan motor 1/16 HP 230 volts including blades complete |
| 71 | All as per Item No.67 above,but PVC Ball valve high pressure with polythene float and fly nut complete for iron pipe 15mm dia |
| 72 | All as per Item No.67 above,but Magnetic door gasket for complete unit |
| 73 | All as per Item No.67 above,but GI/Stainless steel water drain tray |
| 74 | All as per Item No.67 above,but Self closing taps, cast copper alloy, chromium plated serewed for iron pipe 15mm dia |
| 75 | All as per Item No.67 above,but Timer switch |
| 76 | All as per Item No.67 above,but PCB as per sample |
| 77 | All as per Item No.67 above,but OLP as per sample |
| 78 | All as per Item No.67 above,but Fan motor |
| 79 | All as per Item No.67 above,but Fan blade |
| 80 | All as per Item No.67 above,but Capacitor 10-15 mfd |
| 81 | All as per Item No.67 above,but Blower as per sample |
| 82 | M&L for Denting and Spray painting with two coats of synthetic enamel paint over a coat of red oxide primer including repairs of legs for Water Cooler all as specified and directed as Engg in Charge. |
| 83 | Supply and Fixing in replacement of spares of Water circulating pump 1/70 HP capacity single phase 230 Volts 1340 RPM 1.5 Mtr Head suitable for Desert Cooler of any make and size complete all as directed by Eng-in-charge. |
| 84 | S&F in repairs ofKhas-Khas screen complete set for Each Cooler complete all as directed by Eng-in-charge. |
| 85 | S&F in repairs of Float valve suitable for any type of desert coolers 230 volts 50 Hz complete all as directed by Eng-in-charge. |
| 86 | S&F in repairs of PVC Pipe suitable for any type desert cooler 230 volts 50 Hz complete all as directed by Eng-in-charge. |
| 87 | S&F in repairs of Fan motor double speed 230 volts 50 Hz 1/13 HP complete set complete all as directed by Eng-in-charge. |
| 88 | S&F in repairs of Swing Motor complete all as directed by Eng-in-charge. |
| 89 | S&F in repairs of Swing Blade complete all as directed by Eng-in-charge. |
| 90 | S&F in repairs of Fan Blade complete all as directed by Eng-in-charge. |
| 91 | S&F in repairs of Selector Switch heavy duty complete all as directed by Eng-in-charge. |
| 92 | S&F in repairs of Opening shutter for desert coolercomplete all as directed by Eng-in-charge. |
| 93 | S&F in repairs of Distributor complete set complete all as directed by Eng-in-charge. |
| 94 | S&F in repairs of MetallicFront Grill for desert cooler complete all as directed by Eng-in-charge. |
| 95 | S&F in repairs of PVCFront Grill for desert cooler complete all as directed by Eng-in-charge. |
| 96 | S&F install commisision and testing of Desert cooler electrical driven (single phase) having nominal air flow capacity of 4000 cum per hour (or nearest size) plastic/PVC body complete all as directed by Eng-in-charge. |
| 97 | S&F Steel water tubing of medium grade duly ISI marked galvanised of 15mm dia bore including all fittings such as tees, bends and elbow reducer, unions, clamps including cutting the existing line of 20/25 mm dia and connecting complete all as directed by Eng-in-charge. |
| 98 | M&L Servicing to Refrigerator and including supply and charging of refrigerant R-134a/Suitable Refrigerant including cost of welding, leak detection, making good the defects in entire system, testing and commissioning of Refrigerator of 260 to 310 ltrs capacity all as directed by Eng-in-charge. |
| 99 | M&L Refrigerator servicing and including supply and charging of refrigerant R-134a/Suitable Refrigerant including cost of welding, leak detection, making good the defects in entire system, testing and commissioning of Refrigerator of 260 to 310 ltrs capacity complete all as directed by Eng-in-charge. |
| 100 | S&F in repairs of Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc complete all as specified for the following items with capacities of any make including necessary transport from units to work shop and back to units after repairs of Refrigerator of 260 to 310 ltrs capacity complete all as directed by Eng-in-charge.Note 1: Rates deemed to be included for servicing, repairs and replacment of all connected parts, transportation of cooling appliances to work shop and back.Note 2: Rates deemed to be included for the gas required for charging |
| 101 | S&F in repairs of spares of Relay package assembly as per Existing Model for Refrigerator of 260 to 310 ltrs capacity complete all as directed by Eng-in-charge. |
| 102 | All as per Item No.101 above,but Thermostat/cooling sensor |
| 103 | All as per Item No.101 above,butCapillary tube including filter/stainer |
| 104 | All as per Item No.101 above,butCondenser fan motor 1/16 HP 230 volts including blades complete |
| 105 | All as per Item No.101 above,butMagnetic door gasket for complete unit |
| 106 | All as per Item No.101 above,butPVC body tray |
| 107 | All as per Item No.101 above,butFan Blade |
| 108 | All as per Item No.101 above,butCooling coil/freezer |
| 109 | All as per Item No.101 above,butCondenser |
| 110 | All as per Item No.101 above,butBulb |
| 111 | All as per Item No.101 above,butBiometer Fuse |
| 112 | All as per Item No.101 above,butHeater |
| 113 | All as per Item No.101 above,but Timer |
| 114 | All as per Item No.101 above,butTime delay |
| 115 | All as per Item No.101 above,butDoor lock with Key |
| 116 | S&F in repairs ofspares of Rectifier unit suitable for voltage stabilizer of single phase upto 4/5 KVA capaicty complete all as directed by Eng-in-charge. |
| 117 | All as per Item No.116 above,butRelay unit as per sample. |
| 118 | All as per Item No.116 above,butInication lamp set |
| 119 | All as per Item No.116 above,butVot meter 0-250 Volts,AC,Single phase |
| 120 | All as per Item No.116 above,butPower supply control card |
| 121 | All as per Item No.116 above,butLow cut high cut time delay card |
| 122 | All as per Item No.116 above,but9-0-9/12-0-12 Transformer |
| 123 | All as per Item No.116 above,but Power connectors |
| 124 | All as per Item No.116 above,but Main Transformer circuit |
| 125 | M & L Servicing to DeepRefregerator of 320 to 400 ltrs capacity including supply and charging of refrigerant 134(a) or sutable type gas including cost of welding, leak detection, making good the defects in entire system, testing and commissioning ofcomplete all as directed by Eng-in-charge. |
| 126 | S&F in repairs factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Deep Freezer of capacity 320 to 400 ltrs capacity with all necessary items of any make and transport from units to work shop and back to units after repairs complete all as specified and as directed.Note 1: Rates deemed to be included for servicing, repairs and replacement of all connected parts, transportation of cooling appliances to work shop and backNote 2: Rates deemed to be included for the gas required for charging |
| 127 | S&F in repairs ofRelay package assembly as per Existing Modelsuitable for Refregerator of 320 to 400 ltrs capacity complete all as directed. |
| 128 | All as per Item No.127 above, butThermostat/cooling sensor |
| 129 | All as per Item No.127 above,butCapillary tube including filter/strainer |
| 130 | All as per Item No.127 above, but Condensor fan motor 1/16 HP 230 volts including blades complete |
| 131 | All as per Item No.127 above, butMagentic door gasket for complete unit |
| 132 | All as per Item No.127 above, butCooling coil/Freezer |
| 133 | All as per Item No.127 above, butCondensor |
| 134 | All as per Item No.127 above, butBiometer Fuse |
| 135 | All as per Item No.127 above, but Heater |
| 136 | All as per Item No.127 above, butTimer |
| 137 | All as per Item No.127 above, butTime delay |
| 138 | All as per Item No.127 above, butCondensor motor |
| 139 | M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated sheated multistranded FR 1100 volts grade with copper conductor drawn through non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 4 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed. Note: 3 runs of 4 sqmm cable and one run of conduit shall be measured as one unit. |
| 140 | All as per Sl item No 139, but 2 runs of single core 6 Sqmm and one run of single core 6 sqmm as earth continuty conductorNote: 3 runs of 6 Sqmm cable and one run of conduit shall be measured as one unit. |
| 141 | M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated sheated multistranded FR 1100 volts grade with copper conductor drawn through existing non-metalic PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 4 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed.Note: 3 runs of 4 Sqmm cable shall be measured as one unit. |
| 142 | All as per Sl item No 141, but 2runs of single core 6 Sqmm and one run of single core 6 sqmm as earth continuty conductorNote: 3 runs of 6 Sqmm cable shall be measured as one unit. |
| 143 | S & F Horizontal type TPN DB 4 way double door made out of CRCA sheet housing withpowder coating & confirming to IS 13032, IS 8623, BS 5486 accomdated suitably in a MS enclosure weather proof made out of 3 mm thick MS sheet having hinged and robust locking arrangement including painting by red-oxide one coat and powder coated complete all as specified and directed. |