| Sl. No. | Item Description |
| 1 | Construction of auditoriumand miscellaneouswork (Phase-II) of Rana Beni Madhav Baksh Singh memorial District-Raibareli (U.P.). |
| 2 | AMPHIETHEATER BUILDING (CIVIL WORKS) |
| 3 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 4 | Excavation up to 1.50 mt. |
| 5 | Level 1.50 mt. to 3.0 mt. depth |
| 6 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 8 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 9 | Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 10 | Treatment of soil under floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 11 | Treatment of masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 ce ment : 2 coarse sand) to the full depth of the hole,With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 12 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 13 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 14 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Lintel) |
| 15 | Same as above for ground floor (Up to Plinth level) |
| 16 | Same as above for ground floor (Above Plinth level) |
| 17 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 18 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 19 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Slab) |
| 20 | Same as above for ground floor |
| 21 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 22 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 23 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Beam) |
| 24 | Same as above for ground floor (Up to Plinth level) |
| 25 | Same as above for ground floor (Above Plinth level) |
| 26 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 27 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 28 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Footing) |
| 29 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 30 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 31 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Column) |
| 32 | Same as above for ground floor (Up to Plinth level) |
| 33 | Same as above for ground floor (Above Plinth level) |
| 34 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 35 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate12.5 mm nominal size). |
| 36 | Painting on D.P.C. with two coats of air blown bitumen VG-10 grade @ 1.7 kg/sqm approximate including cost of fuel if any. |
| 37 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 38 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 39 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 40 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 41 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
| 42 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) |
| 43 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 44 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 45 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 46 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. |
| 47 | Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm. |
| 48 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : :25 mm thick |
| 49 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 50 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 51 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 52 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). |
| 53 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhat nosing. |
| 54 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 55 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats,square or round bars etc. all complete. Fixed to Steel windows by welding |
| 56 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 57 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 58 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 59 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 2nd class teak wood beading 62X19 mm. |
| 60 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 61 | (a) Single leaf |
| 62 | (b) Double leaf |
| 63 | Fixing of Door/windows/ventilators chaukhats in position. |
| 64 | Door chaukhats |
| 65 | Window chaukhats |
| 66 | Ventilator chaukhats |
| 67 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. |
| 68 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 69 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat. (Inner side) |
| 70 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 71 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat. (Ceiling) |
| 72 | Finishing walls with putty approved brand and manufacturer and of required shade and undacorated wall surface to give even shade over including curing and cost of all material, labour, T & P etc. required for proper completion of work. |
| 73 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm. |
| 74 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. |
| 75 | (a) 250 mm x 10mm |
| 76 | (a) 200 mm x 10mm |
| 77 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm. |
| 78 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 79 | Providing and laying integral cement based water proofing treatment BRICK COBA including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. |
| 80 | over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse |
| 81 | sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 82 | With average thickness of 120mm and minimum thickness at khurra as 65 mm. |
| 83 | Making drain along with the apron. (Size - 150 X 150 MM). |
| 84 | Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 85 | Steel Painting: |
| 86 | (a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 87 | (b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 88 | Wooden Painting: |
| 89 | Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinouswood and plywood. |
| 90 | (b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 91 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush. Red sand stone |
| 92 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately)Red sand stone - Exposed face machine cut and table rubbed with rough backing. 30 mm thick |
| 93 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 94 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Wedge expansion type. Fastener with threaded dia 10 mm |
| 95 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 96 | Finishing walls with Silicon addetive paint on red sand stone ofprepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 97 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 98 | Foundations, footings, bases of columns, etc. for mass concrete |
| 99 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick. |
| 100 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. |
| 101 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 102 | AMPHIETHEATER BUILDING (INTERNAL W/S & SANITATION WORKS) |
| 103 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 104 | White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 105 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 106 | W.C. pan with ISI marked white solid plastic seat and lid |
| 107 | Providing & fixing toilet paper holderC.P. brass |
| 108 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 109 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 110 | White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap |
| 111 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 112 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 113 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 114 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 115 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink) |
| 116 | 15 mm nominal bore |
| 117 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 118 | 45 cm length |
| 119 | 15 mm nominal bore |
| 120 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 121 | 15mm nominal bore |
| 122 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 123 | 15mm nominal bore |
| 124 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 125 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 126 | Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc. |
| 127 | Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. |
| 128 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 129 | Concealed work, including cutting chases and making good the walls etc. |
| 130 | For Internal Toilet |
| 131 | 15 mm nominal outer dia Pipes |
| 132 | 20 mm nominal outer dia Pipes |
| 133 | 25 mm nominal outer dia Pipes |
| 134 | 32 mm nominal outer dia Pipes |
| 135 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 136 | Internal work - Exposed on wall |
| 137 | 20 mm nominal bore |
| 138 | 32 mm nominal bore |
| 139 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall |
| 140 | Terrace loop & Tank Filling Pipe |
| 141 | 25 mm nominal bore |
| 142 | Providing , checking, storing, fixing in positionof approvedqualityScrewed ends Brass float valvewith brassballfloatandPTFE seat suitable forBody test pressure of 15Kg/sqcm of the following sizes: |
| 143 | 25mm |
| 144 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : |
| 145 | 25mm diameter pipe |
| 146 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 147 | 25 to 40 mm nominal bore |
| 148 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 149 | For vertical pipe connection with terrace ringmain |
| 150 | 20 mm nominal bore |
| 151 | 25mm nominal bore |
| 152 | 32mm nominal bore |
| 153 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 154 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 155 | 110 mm dia (for rain water) |
| 156 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. |
| 157 | Single Push Fit Coupler |
| 158 | 110 mm dia |
| 159 | Single tee with door |
| 160 | 110x110x110 mm |
| 161 | Plain bend 87.5 deg |
| 162 | 110 mm dia |
| 163 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 164 | 110 mm dia |
| 165 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 166 | Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. |
| 167 | Internal Toilet (Soil & Waste Pipe) |
| 168 | 75 mm |
| 169 | 110 mm |
| 170 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. |
| 171 | Bend without door (87.5°) |
| 172 | 110mm bend |
| 173 | Bend without door (45°) |
| 174 | 100mm |
| 175 | 75mm |
| 176 | Y\" Fitting without door |
| 177 | 100mm |
| 178 | 75mm |
| 179 | Reduced \"Y\" Fitting without door |
| 180 | 100mm x 75mm |
| 181 | Single Tee without door |
| 182 | 110mm |
| 183 | 75 mm |
| 184 | Single Tee with door |
| 185 | 110mm |
| 186 | Clean Out Plug (COP) |
| 187 | 110mm |
| 188 | 75 mm |
| 189 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. |
| 190 | For Wash basin & Urinal |
| 191 | 50mm dia. Pipe |
| 192 | 32mm dia. Pipe (for wash basin & sunken toilet spout) |
| 193 | Elbow (90°) |
| 194 | 50mm |
| 195 | 32mm |
| 196 | Elbow (45°) |
| 197 | 50mm |
| 198 | 32mm |
| 199 | T fitting |
| 200 | 50mm |
| 201 | 32mm |
| 202 | Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 203 | 110mm x 75mm x 50mm/40mm (Toilet) |
| 204 | Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 205 | 110mm x 75mm (Toilet) |
| 206 | Providing and fixing PTMT grating of approved quality and colour. |
| 207 | Rectangular type with openable circular lid |
| 208 | 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) |
| 209 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 210 | 150 x 100mm size P-type |
| 211 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 212 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: |
| 213 | 100 mm diameter |
| 214 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 215 | All kind of soil |
| 216 | Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 217 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: |
| 218 | 100mm dia SWpipe |
| 219 | AMPHIETHEATER BUILDING (INTERNAL ELECTRIFICATION WORKS) |
| 220 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 221 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 222 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 223 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 224 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 225 | 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire |
| 226 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 227 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 228 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 229 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 230 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 231 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 232 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 233 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep |
| 234 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 235 | Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver). |
| 236 | Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 237 | Supply ofSurface mounting round 15 Watt to 18 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect |
| 238 | Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required. |
| 239 | Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. |
| 240 | Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, |
| 241 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 242 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN |
| 243 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 63 A,25KA,FP MCCB |
| 244 | Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double Door |
| 245 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 246 | 6 way Double door |
| 247 | 8 way Double door |
| 248 | Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.)4 way (4 + 12), Double door |
| 249 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 250 | 40 amps SP MCB |
| 251 | 40 amps DP MCB |
| 252 | 40 amps TP MCB |
| 253 | 40 amps 4P MCB |
| 254 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 25 amps |
| 255 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 256 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 257 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 258 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 259 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 260 | Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required. |
| 261 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 262 | Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 263 | Up to 35 sq.mm. |
| 264 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 265 | Up to 35 sq.mm. |
| 266 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 267 | Upto 35 sq. mm (clamped with 1mm thick saddle |
| 268 | Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment |
| 269 | 3.5 x 25 sq.mm. |
| 270 | 2 x 10 sq.mm, |
| 271 | Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. |
| 272 | 2 X 10 sq. mm (19mm) |
| 273 | 3½ X 25 sq. mm (28mm) |
| 274 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100mm dia |
| 275 | Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 276 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm wide x 50 mm depth x 1.6 mm thickness. |
| 277 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \"bends\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm wide x 50 mm depth x 1.6 mm thickness. |
| 278 | GUEST HOUSE (CIVIL WORKS UP TO PLINTH LEVEL) |
| 279 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 280 | Excavation up to 1.50 mt. |
| 281 | Level 1.50 mt. to 3.0 mt. depth |
| 282 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 283 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) |
| 284 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. |
| 285 | Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 286 | Treatment of soil under floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 287 | Treatment of masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 ce ment : 2 coarse sand) to the full depth of the hole,With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 288 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 289 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 290 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Tie beam) |
| 291 | Same as above for ground floor (Up to Plinth level) |
| 292 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 293 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 294 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Footing)Same as above for ground floor (Up to Plinth level) |
| 295 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 296 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 297 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Column)Same as above for ground floor (Up to Plinth level) |
| 298 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 299 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 13mm nominal size) |
| 300 | Painting on D.P.C. with two coat of air blown bitumen 80/50 @ about 1.7 kg/sqm including cost of fuel if any. |
| 301 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 302 | 15 mm thick plinth plaster [1 cement : 4 coarse sand] |
| 303 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 304 | Foundations, footings, bases of columns, etc. for mass concrete |
| 305 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 306 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. |
| 307 | GUEST HOUSE (CIVIL WORKS ABOVE PLINTH LEVEL) |
| 308 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 309 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 310 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Lintel) |
| 311 | Ground Floor |
| 312 | First/Second Floor |
| 313 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 314 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 315 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] |
| 316 | All works above plinth level - Slab |
| 317 | Ground Floor |
| 318 | First/Second Floor |
| 319 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 320 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 321 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] |
| 322 | All works above plinth level - Beam |
| 323 | Ground Floor |
| 324 | First/Second Floor |
| 325 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 326 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 327 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] |
| 328 | All works above plinth level - Column |
| 329 | Ground Floor |
| 330 | First/Second Floor |
| 331 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 332 | Ground Floor |
| 333 | First/Second Floor |
| 334 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 335 | Ground Floor |
| 336 | First/Second Floor |
| 337 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 338 | Ground Floor |
| 339 | First/Second Floor |
| 340 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 341 | Ground Floor |
| 342 | First/Second Floor |
| 343 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) |
| 344 | Ground Floor |
| 345 | First/Second Floor |
| 346 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 347 | Ground Floor |
| 348 | First/Second Floor |
| 349 | Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm |
| 350 | Ground Floor |
| 351 | First/Second Floor |
| 352 | Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm |
| 353 | Ground Floor |
| 354 | First/Second Floor |
| 355 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 356 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 357 | Ground Floor |
| 358 | First/Second Floor |
| 359 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 360 | Ground Floor |
| 361 | First/Second Floor |
| 362 | Laying of 25 mm thick Kota stone of size 45x45 cm and above flooring over previously prepared base with 2cm 1:3 cement & sand mortar including filling of joints with cement mixed with pigment required for matching the shade of floor as per direction of E/I including cutting polishing with wax polish including supply of all material T & P etc required for proper completion of the work. |
| 363 | Ground Floor |
| 364 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 365 | Ground Floor |
| 366 | First/Second Floor |
| 367 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 368 | Ground Floor |
| 369 | First/Second Floor |
| 370 | Providing and Fixing Knauf Channeled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 13/21mm of visible pane. The edges of the panel shall be “tongue-and-grooved” to fix special clips for installation and seamless visual. |
| 371 | The back of the perforated panel shall have sound absorbing non-woven acoustical fleece hot pressed to achieve NRC upto 0.6. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm.The panels shall be mounted on special aluminium splines (keel) using inside clips provided by Knauf and approved by the Architect/ Engineer-in-Charge. |
| 372 | The panel shall be mounted by tongue and groove mechanism using inside clip on Knauf aluminium extruded keel made of Grade 6063-T5 having dimensions 3000(L) x 24(H) x 15.5(W). The keel shall also be used for transition of the butt end of adjacent panel at every 7.2m. |
| 373 | To ensure specification of tiles, Manufacturers Test Certificate is required having complete site address & duly signed by Manufacturer. |
| 374 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). |
| 375 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 376 | (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Single leaf. |
| 377 | (b) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Double leaf. |
| 378 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 379 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a) Second class teak wood |
| 380 | Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer\"s specification and direction of engineerin- charge. |
| 381 | Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). |
| 382 | Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer’s specification and direction of engineer-incharge. |
| 383 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 |
| 384 | profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, |
| 385 | comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over |
| 386 | backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. |
| 387 | Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. |
| 388 | Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds |
| 389 | Fixed window/ventialtors with mullion /transom. |
| 390 | Using R3 series with frame (55 mm & above) x (45 mm & above) x mullion (55 mm & above) x (65 mm & above). (Height up to 2.5 mt.) |
| 391 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 392 | M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work. |
| 393 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats,square or round bars etc. all complete. Fixed to Steel windows by welding |
| 394 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work (Inner walls & Ceiling) |
| 395 | Ground Floor |
| 396 | First/Second Floor |
| 397 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 398 | Ground Floor |
| 399 | First/Second Floor |
| 400 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. (Inner & Ceiling surface) |
| 401 | Ground Floor |
| 402 | First/Second Floor |
| 403 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 404 | Ground Floor |
| 405 | First/Second Floor |
| 406 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 407 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 408 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete |
| 409 | (a) 250 mm x 10mm (For Door) |
| 410 | Providing and fixing stainless steel handles with screws etc. complete. |
| 411 | (a) 125mmFor Door Handle |
| 412 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. |
| 413 | b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to |
| 414 | required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar |
| 415 | of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge |
| 416 | Steel Painting: |
| 417 | (a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 418 | (b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 419 | Wooden Painting: |
| 420 | Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinouswood and plywood. |
| 421 | (b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 422 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs. |
| 423 | Providing & applying 100% solids, flexible, elastomeric, UV stable, 2 component, waterproof, fast setting, monolithic, hydrophobic in nature, NO-VOC, CFTRI-US-FDA-175-300 coating on prepared surface as following :-P/L DONCRETE/EQUIVALENTPP solvent free primer @ 100gsm per m2 forconjunction of DONCRETE/EQUIVALENT PU conforming to ASTM-D-2369 C,ASTM-D-2369, ASTM-D-638, ASTM-D-4541, ASTM-D- 638, ASTMD- 2240, ASTM-E-96, ASTM-B-117-73, ASTM-D-91, ASTM-D-624, ASTM-D-4060, ASTM-C-8, ASTM-D-512, ASTM-G-53, ASTM-3912 @ 1 Ltr per m2 for 1.00 mm thick. The coating shall be carried out in single application with multiple passes, using high pressure plural component reactor strictly as per manufacture specification, rate materials, labor, and tools. Surface preparation includes repairs of holes, cracks, voids, pinholes, bug holes. Joints shall be filled with epoxy putty Confirming the ASTM D 638, ASTMD 4541, and ASTM D 2369. The corner rounding/angle fillet shall be prepared/replaced as required to smooth transition of coating from horizontal to vertical surfaces. |
| 424 | 20 mm cement plaster of mix Cement mortar 1:4. forprotect of waterproofing area. |
| 425 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. |
| 426 | Providing and fixing stainless steel ( Grade 304) railing with toughened glass made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 427 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 428 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Ordinary cement without any pigment |
| 429 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 430 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick. |
| 431 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. |
| 432 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 433 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. |
| 434 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: |
| 435 | a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: |
| 436 | b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry /structural steel frame work of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. |
| 437 | c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. |
| 438 | d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it water tight |
| 439 | e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. |
| 440 | The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin-Charge. |
| 441 | Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. |
| 442 | Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories |
| 443 | 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml” |
| 444 | 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” |
| 445 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. |
| 446 | The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm |
| 447 | (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 448 | Providing & Fixing of Knauf Fibre Glass Acoustical Suspended Ceiling System with 15 mm thick Optra Microlook 90 Edge Tiles with Knauf Suprafine 15mm face exposed grid. |
| 449 | The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.85 – 0.95(Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, Light Reflectance ?88% as per ASTM E-1477, Colour Pebble White/Black, Fire Performance of Class 0/1 as per BS 476 Part 6/7 with 15mm Square Tegular/Microlook 90? edge and 8mm drop in module size of 600 x 600mm. It shall be suitable for Green Building application, with Recycled content of 85%. |
| 450 | SUSPENSION: The tile shall be laid on Knauf Suprafine 32 with 15 mm wide T - section flanges colour global white having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm (all sections). The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. |
| 451 | To ensure specification of tiles, Manufacturers Test Certificate is requiredhavingcomplete site address& duly signed by Manufacturer. |
| 452 | INSTALLATION : To comprise main runner spaced at 1200mm securely fixed to the structural soffit using Knauf suspension system (specifications above) at 1200mm maximum. The First/Last Knauf suspension system at theend of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. |
| 453 | Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module.Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. |
| 454 | Perimeter trim to be Knauf wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation should be carried out as per Knauf recommended procedure and designs approved by the Architect/ Engineer-in-Charge. |
| 455 | KNAUF SUSPENSION SYSTEM - accessories supplied by Knauf consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners). |
| 456 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. |
| 457 | iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) |
| 458 | Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @ 0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. |
| 459 | GUEST HOUSE (INTERNAL W/S & SANITATION WORKS) |
| 460 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 461 | W.C. pan with ISI marked white solid plastic seat and lid |
| 462 | Providing and fixing white vitreous chinaextended wall mounting type water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) includung seat cover & cistern fittings nuts , bolts and gaskets etc complete. |
| 463 | Providing & fixing toilet paper holder C.P. brass |
| 464 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 465 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 466 | White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap |
| 467 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- |
| 468 | (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 469 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 470 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 471 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 472 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 473 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink) |
| 474 | 15 mm nominal bore |
| 475 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 476 | 45 cm length |
| 477 | 15 mm nominal bore |
| 478 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 479 | 100 mm diameter |
| 480 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. |
| 481 | 15 mm nominal dia |
| 482 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 483 | 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms. |
| 484 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required |
| 485 | Kitchen sink with drain board |
| 486 | 510x1040 mm bowl depth 200 mm |
| 487 | Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete |
| 488 | Flexible Pipe |
| 489 | 32mm Dia |
| 490 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 491 | 15mm nominal bore |
| 492 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 493 | 15mm nominal bore |
| 494 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 495 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth. White Agaria Marble StoneGranite Stone of approved shade |
| 496 | Providing and fixing of storage type (pressurised type) electrichot water heater copper sheet container, 25 mm thickinsulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. Capacity 25 Liters |
| 497 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 498 | Concealed work, including cutting chases and making good the walls etc. |
| 499 | For Internal Toilet |
| 500 | 15 mm nominal outer dia Pipes |
| 501 | 20 mm nominal outer dia Pipes |
| 502 | 25 mm nominal outer dia Pipes |
| 503 | 32 mm nominal bore |
| 504 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 505 | Internal work - Exposed on wall |
| 506 | 20 mm nominal bore |
| 507 | 25 mm nominal bore |
| 508 | 32 mm nominal bore |
| 509 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall |
| 510 | Terrace loop & Tank Filling Pipe |
| 511 | 40 mm nominal bore |
| 512 | 50 mm nominal bore |
| 513 | Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:- |
| 514 | Lehry Make Automatic OHT Level Control System Consist of Following Items |
| 515 | 1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch.40mm |
| 516 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : |
| 517 | 40mm diameter pipe |
| 518 | 50mm diameter pipe |
| 519 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 520 | For vertical pipe connection with terrace ringmain |
| 521 | 20 mm nominal bore |
| 522 | 25mm nominal bore |
| 523 | 32mm nominal bore |
| 524 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 525 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mmof suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. |
| 526 | 25mm dia. |
| 527 | 40mm dia. |
| 528 | 50mm dia. |
| 529 | 65mm dia. |
| 530 | 80mm dia. |
| 531 | 100mm dia. |
| 532 | 150mm dia. |
| 533 | 200mm dia. |
| 534 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm dia (for rain water) |
| 535 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. |
| 536 | Single Push Fit Coupler |
| 537 | 110 mm dia |
| 538 | Single tee with door |
| 539 | 110x110x110 mm |
| 540 | Plain bend 87.5 deg |
| 541 | 110 mm dia |
| 542 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm dia |
| 543 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 544 | Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. |
| 545 | Internal Toilet (Soil & Waste Pipe) |
| 546 | 75 mm |
| 547 | 110 mm |
| 548 | Exposed on Wall (Soil & Waste Pipe) |
| 549 | 110 mm |
| 550 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. |
| 551 | Bend without door (87.5°) |
| 552 | 110mm bend |
| 553 | Bend without door (45°) |
| 554 | 100mm |
| 555 | 75mm |
| 556 | Y\" Fitting without door |
| 557 | 100mm |
| 558 | 75mm |
| 559 | Reduced \"Y\" Fitting without door |
| 560 | 100mm x 75mm |
| 561 | Single Tee without door |
| 562 | 110mm |
| 563 | 75 mm |
| 564 | Single Tee with door |
| 565 | 110mm |
| 566 | Reduced Tee with door |
| 567 | 110mm x 75mm |
| 568 | Coupler |
| 569 | 110mm |
| 570 | Clean Out Plug (COP) |
| 571 | 110mm |
| 572 | 75 mm |
| 573 | Vent Cowl |
| 574 | 110mm |
| 575 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. |
| 576 | For Wash basin & Urinal |
| 577 | 50mm dia. Pipe |
| 578 | 32mm dia. Pipe (for wash basin & sunken toilet spout) |
| 579 | Elbow (90°) |
| 580 | 50mm |
| 581 | 32mm |
| 582 | Elbow (45°) |
| 583 | 50mm |
| 584 | 32mm |
| 585 | T fitting |
| 586 | 50mm |
| 587 | 32mm |
| 588 | Coupler |
| 589 | 32mm |
| 590 | Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 591 | 110mm x 75mm x 50mm/40mm (Toilet) |
| 592 | Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 593 | 110mm x 75mm (Toilet) |
| 594 | 110mm x 75mm (Kitchen) |
| 595 | Providing and fixing PTMT grating of approved quality and colour. |
| 596 | Rectangular type with openable circular lid |
| 597 | 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) |
| 598 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 599 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter |
| 600 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 601 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: |
| 602 | GUEST HOUSE (INTERNAL ELECTRIFICATION WORKS) |
| 603 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 604 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 605 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 606 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 607 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 608 | 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 609 | 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire |
| 610 | 4 x 16 sq.mm + 2 x 6sq.mm. earth wire |
| 611 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 612 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 613 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 614 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 615 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 616 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 617 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 618 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 619 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
| 620 | Upto 450 mm sweep |
| 621 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 622 | Supply of Recessed mounting 2x2 feet 36W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 623 | Supply of Recessed mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 624 | Supply of LED 4ft 40W LED Tube light with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 42W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor |
| 625 | Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver). |
| 626 | Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 627 | Supply ofSurface mounting round 15 Watt to 18 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect |
| 628 | Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required. |
| 629 | Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. |
| 630 | Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, |
| 631 | Supplying of 9 Watt Decorative LED Wall Light complete in all respect. |
| 632 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 633 | Supplying, erection, connecting, testing and commissioning of 400 mm Wall Fancomplete in all respect. |
| 634 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN |
| 635 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required |
| 636 | 63 A,25KA,FP MCCB |
| 637 | 100 A,30KA,FPMCCB |
| 638 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 639 | 6 way Double door |
| 640 | 8 way Double door |
| 641 | Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.)4 way (4 + 12), Double door |
| 642 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 643 | 40 amps TP MCB |
| 644 | 63 amps TP MCB |
| 645 | 40 amps 4P MCB |
| 646 | 63 amps 4P MCB |
| 647 | 100 amps 4P MCB |
| 648 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. |
| 649 | 25 amps |
| 650 | 40 amps |
| 651 | 63 amps |
| 652 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 653 | Single pole |
| 654 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 655 | Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround |
| 656 | the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB\"s to be used.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. |
| 657 | The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. |
| 658 | The minimum clearances between bus bars shall be as follows : |
| 659 | Phase to phase - minimum 20mm |
| 660 | Phase to neutral-minimum 15mm |
| 661 | GUEST HOUSE PANEL |
| 662 | INCOMING |
| 663 | 1No. Of 400 Amps FP MCCB of 35KA breaking capacity |
| 664 | Metering : |
| 665 | 1 Set of CT\"s one of 400/ 5Amp ratio for Multifunction Meter |
| 666 | One (1) Set of Phase Indication Lamp. |
| 667 | BUS BAR |
| 668 | 1 Set of 500 Amps TPN Aluminium Bus Bars |
| 669 | OUTCOMING |
| 670 | 250 Amps FP MCCB of 25KA - 1 No |
| 671 | 125 Amps FP MCCB of 25KA - 1 No |
| 672 | 100 Amps FP MCCB of 25KA - 6 No |
| 673 | 80 Amps FP MCCB of 25KA - 1 No |
| 674 | 63 Amps FP MCCB of 25KA - 3 No |
| 675 | 40 Amps FP MCCB of 25KA - 1 No |
| 676 | SPARE & SPACE- 1 No |
| 677 | Panel described as above |
| 678 | ELEVATOR PANEL |
| 679 | INCOMING |
| 680 | 1No. Of 80 Amps FP MCCB of 25KA breaking capacity |
| 681 | Metering : |
| 682 | 1 Set of CT\"s one of 80/ 5Amp ratio for Multifunction Meter |
| 683 | One (1) Set of Phase Indication Lamp. |
| 684 | BUS BAR |
| 685 | 1 Set of 100 Amps TPN Aluminium Bus Bars |
| 686 | OUTCOMING |
| 687 | 63 Amps 4P MCCB of 25KA - 2 No |
| 688 | 63 Amps DP MCB of 10KA - 2 No |
| 689 | SPARE & SPACE- 1 No |
| 690 | Panel described as above |
| 691 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 692 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 693 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 694 | Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required. |
| 695 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 696 | Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes:2 Pair (4 core) |
| 697 | Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe.10 Pair telephone cable |
| 698 | Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted.10 pair tag block |
| 699 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 700 | 20mm dia PVC conduit |
| 701 | 25mm dia PVC conduit |
| 702 | 32mm dia PVC conduit |
| 703 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required1 or 2 Module (75mmX75mm) |
| 704 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 705 | Telephone socket outlet |
| 706 | TV antenna socket outlet |
| 707 | Bell Push |
| 708 | RJ-45 Data Socket outlet |
| 709 | Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required. |
| 710 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 711 | 1 run of cable |
| 712 | Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe. |
| 713 | Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 714 | Up to 35 sq.mm. |
| 715 | Above 185 sq.mm. and up to 400 sq.mm. |
| 716 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 717 | Up to 35 sq.mm. |
| 718 | Above 185 sq.mm. and up to 400 sq.mm. |
| 719 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 720 | Upto 35 sq. mm (clamped with 1mm thick saddle |
| 721 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 722 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 723 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 724 | Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment |
| 725 | 3.5 x 300 sq.mm. |
| 726 | 3.5 x 50 sq.mm |
| 727 | 3.5 x 35 sq.mm |
| 728 | 3.5 x 25 sq.mm. |
| 729 | Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. |
| 730 | 3½ X 25 sq. mm (28mm) |
| 731 | 3½ X 35 sq. mm (32mm) |
| 732 | 3½ X 50 sq. mm (35mm) |
| 733 | 3½ X 300 sq. mm (70mm) |
| 734 | Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required |
| 735 | 100 mm dia |
| 736 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 737 | 100mm dia |
| 738 | 150 mm dia |
| 739 | Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. |
| 740 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 741 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 742 | 100 mm wide x 50 mm depth x 1.6 mm thickness. |
| 743 | 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 744 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \"bends\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 745 | 100 mm wide x 50 mm depth x 1.6 mm thickness. |
| 746 | 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 747 | Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray \"Tee\" (galvanisation not less than 50microns) with perforation not more than 17.5%, in convenientsections, joined with connectors, suspended from the ceilingwith G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 748 | 100 mm wide x 50 mm depth x 1.6 mm thickness. |
| 749 | 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 750 | GUEST HOUSE (FIRE FIGHTING) |
| 751 | FIRE PUMPS - ELECTRICALSupplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : |
| 752 | (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.(b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Suitable cement concrete foundation duly plastered with anti vibration pads. |
| 753 | 1620 lpm at 70 m Head |
| 754 | FIRE PUMPS - DIESEL ENGINE DRIVENSupplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. |
| 755 | Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plasteredand with anti vibration pads. |
| 756 | 1620 lpm at 70 m Head |
| 757 | JOCKEY PUMP:-Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) |
| 758 | Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. |
| 759 | Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 760 | 180 lpm at 70 m Head |
| 761 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 762 | Pressure VesselProviding, fixing, testing and commissioning of pressure vessel for pressurization of fire system complete with valves at outlet / drain to operate as per operating sequencesincluding25 mmdia drain valve, air release valve with stop cock on the top, outside with one coat of primer & two coats of synthetic enamel paint of approved shade complete as required to operate commonly main fire pump, sprinkler pump & jockey pump at drop of pressure, automatically at required pressure setting.It should be complete as per manufacturer\"s specifications & as directed by Engineer- in-charge.working pressure:- 7 kg/sqcmtest pressure: 10 kg/sqcm |
| 763 | (450 mm dia & 2000 mm height) |
| 764 | Providing and fixing in position the industrial type pressuregauges with gun metal / brass valves complete as required |
| 765 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 766 | 200 mm dia. |
| 767 | 150 mm dia. |
| 768 | 100 mm dia. |
| 769 | 80 mm dia. |
| 770 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 771 | 150 mm dia. |
| 772 | 80 mm dia. |
| 773 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 200 mm dia. |
| 774 | Providing laying, testing & commissioning of \"C\" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (EXTERNAL WORKS)150 mm dia. |
| 775 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (PUMP ROOM WORKS) |
| 776 | 80 mm nominal bore |
| 777 | 100 mm nominal bore |
| 778 | 150 mm nominal bore |
| 779 | 200 mm dia (wall thickness 6.3 mm) |
| 780 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required : |
| 781 | 2 way - 100 mm dia M.S. Pipe (Siamese Connection) |
| 782 | 4 way - 150 mm dia M.S. Pipe |
| 783 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in allrespects, as required: (Terrace Pump) |
| 784 | (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 |
| 785 | b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. |
| 786 | (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. |
| 787 | (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 788 | 450 lpm at 35 m Head |
| 789 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump) |
| 790 | Providing & fixing of start/stop push buttons including complete connection etc. as required. (for terrace booster pump) |
| 791 | Providing and fixing in position the industrial type pressuregauges with gun metal / brass valves complete as required (for terrace booster pump) |
| 792 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 793 | 100 mm dia. |
| 794 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 795 | 100 mm dia. |
| 796 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 797 | 80 mm nominal bore |
| 798 | 100 mm nominal bore |
| 799 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal |
| 800 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.40 m |
| 801 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : |
| 802 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : |
| 803 | Providingandfixing standard fire mans axe with heavy duty insulated rubber handle. |
| 804 | Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door:900mm Wide & 1500mm Height) |
| 805 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 806 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 807 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 808 | Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 809 | Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. |
| 810 | FIRE FIGHTING PANEL |
| 811 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : |
| 812 | INCOMING |
| 813 | 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0 500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A |
| 814 | OUTGOING( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) |
| 815 | Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. |
| 816 | Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. |
| 817 | DIESEL ENGINE CONTROLControl for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engineSystem ControllerDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification |
| 818 | Fabricating & Supply, installing, testing and commissioning ofsheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 5.5 KW/7.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. DOL Starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle.(As per the Technical Specifications)(At Terrace floor) |
| 819 | Supply, installation , testing & commissioning of XLPE insulated and PVC outer sheathed Aluminium conductor armoured cable of 1.1 KV grade confirming to IS : 7098:1988 (with upto date amendments) of following sizes. |
| 820 | 3 Core, X 50 sqmm. |
| 821 | 3 Core, X 6 sqmm. |
| 822 | Supplying and making end termination with brass compression gland & Al.lugs for following sizes of PVC insulated, PVC sheathed/ XLPE Al.conductor cables of 1.1 KV grade as required. |
| 823 | 3 Core, X 50 sqmm. |
| 824 | 3 Core, X 6 sqmm. |
| 825 | Supplying and laying control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathedarmoured cable between various sensors and system controller/starter etc.in pump house & out side on surface/existing cable tray complete with connections at both end with glands etc.as required |
| 826 | 4 x 2.5 sq.mm |
| 827 | 2 x 2.5 sq.mm |
| 828 | Supply and fixing in position 1 m wide Insulation mat made of elastomeric polymers Material (Class -A) of 415V grade as perIS 15642-2006 .Thickness of insulation mat shall be not less than 2 mmto withstand 1.1 KV dielectric strength AS PER IS 15652 : 2006. It should be complete as per specifications & directions of Engineer-in-charge.It should be complete as per specifications & directions of Engineer-in-charge. |
| 829 | Supplying and installing following size of perforated pre-painted M.S.cabletrayswithperforationnotmorethan17.5%,in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width x 50mm depth x 1.6 mm thickness. |
| 830 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. |
| 831 | Two Loop Panel. |
| 832 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 833 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 834 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 835 | Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. |
| 836 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 837 | Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. |
| 838 | Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. |
| 839 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 840 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 841 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheathcomplete as required. |
| 842 | TYPE - II RESIDENCES (CIVIL WORKS) |
| 843 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 844 | Excavation up to 1.50 mt. |
| 845 | Level 1.50 mt. to 3.0 mt. depth |
| 846 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 847 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. |
| 848 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) |
| 849 | Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 850 | Treatment of soil under floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 851 | (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. |
| 852 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 853 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 854 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Lintel) |
| 855 | All works upto plinth level (Plinth beam) |
| 856 | All works above plinth level (Plinth beam) |
| 857 | First floor |
| 858 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 859 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 860 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Slab) |
| 861 | Ground floor |
| 862 | First floor |
| 863 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 864 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 865 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Beam) |
| 866 | Ground floor |
| 867 | First floor |
| 868 | Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 40 mm thick |
| 869 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 870 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 871 | Ground floor |
| 872 | First floor |
| 873 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 874 | Ground floor |
| 875 | First floor |
| 876 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 877 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 13mm nominal size) |
| 878 | Painting on D.P.C. with two coat of air blown bitumen 80/50 @ about 1.7 kg/sqm including cost of fuel if any. |
| 879 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. |
| 880 | b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to |
| 881 | required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix |
| 882 | 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge |
| 883 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 884 | (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Single leaf. |
| 885 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 886 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 887 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 888 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats,square or round bars etc. all complete. Fixed to Steel windows by welding |
| 889 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 890 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 891 | Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. Second class teak wood |
| 892 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (a) 35mm thick Second class teak wood. |
| 893 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 894 | Ground floor |
| 895 | First floor |
| 896 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. |
| 897 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 898 | Ground floor |
| 899 | First floor |
| 900 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) |
| 901 | Ground floor |
| 902 | First floor |
| 903 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to I.S. : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 904 | Ground floor |
| 905 | First floor |
| 906 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. : 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 907 | Ground floor |
| 908 | First floor |
| 909 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 910 | Ground floor |
| 911 | First floor |
| 912 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 913 | Ground floor |
| 914 | First floor |
| 915 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement.(25mm thick C.C. flooring.) |
| 916 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 917 | Ground floor |
| 918 | First floor |
| 919 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 920 | Ground floor |
| 921 | First floor |
| 922 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm |
| 923 | Steel Painting: |
| 924 | (a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 925 | (b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 926 | Wooden Painting: |
| 927 | Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinouswood and plywood. |
| 928 | (b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 929 | French spirit polishing : Two or more coats on new works including a coat of wood filler |
| 930 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. (Outer surface) |
| 931 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work (Inner surface) |
| 932 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work (Ceiling) |
| 933 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 934 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 935 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (a) 250mm x 16mm. |
| 936 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 937 | (a) 250 mm x 10mm |
| 938 | (a) 200 mm x 10mm |
| 939 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm |
| 940 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs. |
| 941 | Providing & applying 100% solids, flexible, elastomeric, UV stable, 2 component, waterproof, fast setting, monolithic, hydrophobic in nature, NO-VOC, CFTRI-US-FDA-175-300 coating on prepared surface as following :-P/L DONCRETE/EQUIVALENTPP solvent free primer @ 100gsm per m2 forconjunction of DONCRETE/EQUIVALENT PU conforming to ASTM-D-2369 C,ASTM-D-2369, ASTM-D-638, ASTM-D-4541, ASTM-D- 638, ASTMD- 2240, ASTM-E-96, ASTM-B-117-73, ASTM-D-91, ASTM-D-624, ASTM-D-4060, ASTM-C-8, ASTM-D-512, ASTM-G-53, ASTM-3912 @ 1 Ltr per m2 for 1.00 mm thick. The coating shall be carried out in single application with multiple passes, using high pressure plural component reactor strictly as per manufacture specification, rate materials, labor, and tools. Surface preparation includes repairs of holes, cracks, voids, pinholes, bug holes. Joints shall be filled with epoxy putty Confirming the ASTM D 638, ASTMD 4541, and ASTM D 2369. The corner rounding/angle fillet shall be prepared/replaced as required to smooth transition of coating from horizontal to vertical surfaces. |
| 942 | P/F curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc. wherever necessary complete (a) 25 mm dia. |
| 943 | Providing and fixing cup board shutters with 25 mm thick veneered particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge. With non decorative veneering on both sides |
| 944 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 945 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick. |
| 946 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. |
| 947 | TYPE - II RESIDENCES (INTERNAL W/S & SANITATION WORKS) |
| 948 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 949 | White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 950 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 951 | White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap |
| 952 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 953 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 954 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 955 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 956 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink)15 mm nominal bore |
| 957 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore |
| 958 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 959 | 100 mm diameter |
| 960 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 961 | 15 mm nominal bore |
| 962 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 963 | 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms. |
| 964 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required |
| 965 | Kitchen sink with drain board |
| 966 | 510x1040 mm bowl depth 200 mm |
| 967 | Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete |
| 968 | Flexible Pipe |
| 969 | 32mm Dia |
| 970 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 971 | 15mm nominal bore |
| 972 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 973 | 15mm nominal bore |
| 974 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 975 | Concealed work, including cutting chases and making good the walls etc. |
| 976 | For Internal Toilet |
| 977 | 15 mm nominal outer dia Pipes |
| 978 | 20 mm nominal outer dia Pipes |
| 979 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 980 | Internal work - Exposed on wall |
| 981 | 20 mm nominal bore |
| 982 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall |
| 983 | Terrace loop & Tank Filling Pipe |
| 984 | 25 mm nominal bore |
| 985 | Providing , checking, storing, fixing in positionof approvedqualityScrewed ends Brass float valvewith brassballfloatandPTFE seat suitable forBody test pressure of 15Kg/sqcm of the following sizes: |
| 986 | 25mm |
| 987 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : |
| 988 | 25mm diameter pipe |
| 989 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 990 | 25 to 40 mm nominal bore |
| 991 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 992 | For vertical pipe connection with terrace ringmain |
| 993 | 20 mm nominal bore |
| 994 | 25mm nominal bore |
| 995 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 996 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 997 | 110 mm dia (for rain water) |
| 998 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. |
| 999 | Single Push Fit Coupler |
| 1000 | 110 mm dia |
| 1001 | Single tee with door |
| 1002 | 110x110x110 mm |
| 1003 | Plain bend 87.5 deg |
| 1004 | 110 mm dia |
| 1005 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 1006 | 110 mm dia |
| 1007 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 1008 | Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. |
| 1009 | Internal Toilet (Soil & Waste Pipe) |
| 1010 | 75 mm |
| 1011 | 110 mm |
| 1012 | Exposed on Wall (Soil & Waste Pipe) |
| 1013 | 110 mm |
| 1014 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. |
| 1015 | Bend without door (45°) |
| 1016 | 100mm |
| 1017 | 75mm |
| 1018 | Y\" Fitting without door |
| 1019 | 100mm |
| 1020 | 75mm |
| 1021 | Single Tee without door |
| 1022 | 110mm |
| 1023 | 75 mm |
| 1024 | Single Tee with door |
| 1025 | 110mm |
| 1026 | Reduced Tee with door |
| 1027 | 110mm x 75mm |
| 1028 | Coupler |
| 1029 | 110mm |
| 1030 | Clean Out Plug (COP) |
| 1031 | 110mm |
| 1032 | 75 mm |
| 1033 | Vent Cowl |
| 1034 | 110mm |
| 1035 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. |
| 1036 | For Wash basin & Urinal |
| 1037 | 32mm dia. Pipe (for wash basin & sunken toilet spout) |
| 1038 | Elbow (90°) |
| 1039 | 32mm |
| 1040 | Elbow (45°) |
| 1041 | 32mm |
| 1042 | Coupler |
| 1043 | 32mm |
| 1044 | Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 1045 | 110mm x 75mm x 50mm/40mm (Toilet) |
| 1046 | Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 1047 | 110mm x 75mm (Toilet) |
| 1048 | 110mm x 75mm (Kitchen) |
| 1049 | Providing and fixing PTMT grating of approved quality and colour. |
| 1050 | Rectangular type with openable circular lid |
| 1051 | 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) |
| 1052 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 1053 | 150 x 100mm size P-type |
| 1054 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1055 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: |
| 1056 | 100 mm diameter |
| 1057 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 1058 | All kind of soil |
| 1059 | Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 1060 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: |
| 1061 | 100mm dia SWpipe |
| 1062 | TYPE - II RESIDENCES (INTERNAL ELECTRIFCATION WORKS) |
| 1063 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 1064 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 1065 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 1066 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 1067 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 1068 | 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 1069 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 1070 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 1071 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 1072 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 1073 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 1074 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 1075 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 1076 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
| 1077 | Upto 450 mm sweep |
| 1078 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 1079 | Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver). |
| 1080 | Supply ofSurface mounting round 15 Watt to 18 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect |
| 1081 | Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, |
| 1082 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 1083 | Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect. |
| 1084 | Supplying of 9 Watt Decorative LED Wall Light complete in all respect. |
| 1085 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 1086 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN |
| 1087 | Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double Door |
| 1088 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 1089 | Single pole |
| 1090 | Double pole |
| 1091 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 1092 | Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB\"s to be used.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. |
| 1093 | The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. |
| 1094 | The minimum clearances between bus bars shall be as follows : |
| 1095 | Phase to phase - minimum 20mm |
| 1096 | Phase to neutral-minimum 15mm |
| 1097 | METERING PANEL TYPE-II |
| 1098 | Incoming : |
| 1099 | One (1) No 63 Amp. 4P MCCB of 25KA |
| 1100 | Metering : |
| 1101 | 1 Set of CT\"s one of 60/ 5Amp ratio for Multifunction Meter |
| 1102 | One (1) Set of Phase Indication Lamp. |
| 1103 | Bus Bar : |
| 1104 | One (1) No. 100 Amp.TPN aluminimum bus bar of suitable length. |
| 1105 | Outgoing : |
| 1106 | Phase indication lamps on each outgoing to be provided. |
| 1107 | 32 Amps DP MCB of 10KA (Ics=Icu)Breaking Capacity- 5 No |
| 1108 | 10 Amps DP MCB of 10KA (Ics=Icu)Breaking Capacity- 2 No |
| 1109 | 1 Phase Energy Meter-5Nos. |
| 1110 | Panel described as above |
| 1111 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 1112 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 1113 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 1114 | Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required. |
| 1115 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 1116 | Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: |
| 1117 | 2 Pair (4 core) |
| 1118 | Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe. |
| 1119 | 10 Pair telephone cable |
| 1120 | Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. |
| 1121 | 10 pair tag block |
| 1122 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 1123 | 20mm dia PVC conduit |
| 1124 | 25mm dia PVC conduit |
| 1125 | 32mm dia PVC conduit |
| 1126 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required |
| 1127 | 1 or 2 Module (75mmX75mm) |
| 1128 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 1129 | Telephone socket outlet |
| 1130 | TV antenna socket outlet |
| 1131 | Bell Push |
| 1132 | Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required. |
| 1133 | Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe. |
| 1134 | Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1135 | Up to 35 sq.mm. |
| 1136 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 1137 | Up to 35 sq.mm. |
| 1138 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 1139 | Upto 35 sq. mm (clamped with 1mm thick saddle |
| 1140 | Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment |
| 1141 | 3.5 x 25 sq.mm. |
| 1142 | Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. |
| 1143 | 3½ X 25 sq. mm (28mm) |
| 1144 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 1145 | 100mm dia |
| 1146 | Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. |
| 1147 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 1148 | GUARD ROOM (CIVIL WORKS) |
| 1149 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 1150 | Excavation up to 1.50 mt. |
| 1151 | Level 1.50 mt. to 3.0 mt. depth |
| 1152 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 1153 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in foundation and floors. |
| 1154 | Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand. |
| 1155 | Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 1156 | Treatment of soil under floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 1157 | (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. |
| 1158 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1159 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1160 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Lintel) |
| 1161 | Same as above for ground floor (Up to Plinth level) |
| 1162 | Same as above for ground floor (Above Plinth level) |
| 1163 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1164 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1165 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Slab) |
| 1166 | Same as above for ground floor |
| 1167 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1168 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1169 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Beam) |
| 1170 | Same as above for ground floor |
| 1171 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1172 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1173 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Footing) |
| 1174 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1175 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1176 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Column) |
| 1177 | Same as above for ground floor (Up to Plinth level) |
| 1178 | Same as above for ground floor (Above Plinth level) |
| 1179 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1180 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate12.5 mm nominal size). |
| 1181 | Painting on D.P.C. with two coats of air blown bitumen VG-10 grade @ 1.7 kg/sqm approximate including cost of fuel if any. |
| 1182 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1183 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class -150in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 1184 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 1185 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 1186 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
| 1187 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
| 1188 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 1189 | Making grooves 10 to 12mmwide x8mm deep in plaster of the walls or in ceiling vertically or horizontally as required. |
| 1190 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate. |
| 1191 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. (25mm thick) |
| 1192 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick |
| 1193 | Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm |
| 1194 | Providing and fixing glass strips in joints of terrazo/ cement concretefloors. 40 mm wide and 4 mm thick. |
| 1195 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 1196 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 1197 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 1198 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 1199 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 1200 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats,square or round bars etc. all complete. Fixed to Steel windows by welding |
| 1201 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 1202 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 1203 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 1204 | Providing & laying cement concrete in 1:2:4 of not less than stregth M-150 Stone ballast (20mm nominal size) approved coarse sand and cement, curing complete, including cost of form work. In foundation and floors. |
| 1205 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work. (Inner walls) |
| 1206 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 1207 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work. (Ceiling area) |
| 1208 | Finishing walls with putty approved brand and manufacturer and of required shade and undacorated wall surface to give even shade over including curing and cost of all material, labour, T & P etc. required for proper completion of work. |
| 1209 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete. (a) 250mm x 16mm |
| 1210 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete |
| 1211 | (a) 250 mm x 10mm |
| 1212 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete. 125mm |
| 1213 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. |
| 1214 | Steel Painting: |
| 1215 | (a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 1216 | (b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 1217 | Wooden Painting: |
| 1218 | Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinouswood and plywood. |
| 1219 | (b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 1220 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- |
| 1221 | in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix |
| 1222 | 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 1223 | With average thickness of 120mm and minimum thickness at khurra as 65 mm. |
| 1224 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 1225 | Foundations, footings, bases of columns, etc. for mass concrete |
| 1226 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick. |
| 1227 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. |
| 1228 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 1229 | GUARD ROOM (INTERNAL W&S SANITATION WORKS) |
| 1230 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 1231 | White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 1232 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 1233 | White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap |
| 1234 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 1235 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 1236 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 1237 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 1238 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink) |
| 1239 | 15 mm nominal bore |
| 1240 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 1241 | 45 cm length |
| 1242 | 15 mm nominal bore |
| 1243 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 1244 | 15mm nominal bore |
| 1245 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 1246 | Concealed work, including cutting chases and making good the walls etc. |
| 1247 | For Internal Toilet |
| 1248 | 15 mm nominal outer dia Pipes |
| 1249 | 20 mm nominal outer dia Pipes |
| 1250 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 1251 | Internal work - Exposed on wall |
| 1252 | 20 mm nominal bore |
| 1253 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall |
| 1254 | Terrace loop & Tank Filling Pipe |
| 1255 | 25 mm nominal bore |
| 1256 | Providing , checking, storing, fixing in positionof approvedqualityScrewed ends Brass float valvewith brassballfloatandPTFE seat suitable forBody test pressure of 15Kg/sqcm of the following sizes: |
| 1257 | 25mm |
| 1258 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : |
| 1259 | 25mm diameter pipe |
| 1260 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 1261 | 25 to 40 mm nominal bore |
| 1262 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 1263 | For vertical pipe connection with terrace ringmain |
| 1264 | 20 mm nominal bore |
| 1265 | 25mm nominal bore |
| 1266 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 1267 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 1268 | 110 mm dia (for rain water) |
| 1269 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. |
| 1270 | Single Push Fit Coupler |
| 1271 | 110 mm dia |
| 1272 | Single tee with door |
| 1273 | 110x110x110 mm |
| 1274 | Plain bend 87.5 deg |
| 1275 | 110 mm dia |
| 1276 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 1277 | 110 mm dia |
| 1278 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 1279 | Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. |
| 1280 | Internal Toilet (Soil & Waste Pipe) |
| 1281 | 75 mm |
| 1282 | 110 mm |
| 1283 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. |
| 1284 | Bend without door (45°) |
| 1285 | 75mm |
| 1286 | Y\" Fitting without door |
| 1287 | 75mm |
| 1288 | Single Tee without door |
| 1289 | 75 mm |
| 1290 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. |
| 1291 | For Wash basin & Urinal |
| 1292 | 32mm dia. Pipe (for wash basin & sunken toilet spout) |
| 1293 | Elbow (90°) |
| 1294 | 32mm |
| 1295 | Elbow (45°) |
| 1296 | 32mm |
| 1297 | T fitting |
| 1298 | 32mm |
| 1299 | Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 1300 | 110mm x 75mm x 50mm/40mm (Toilet) |
| 1301 | Providing and fixing PTMT grating of approved quality and colour. |
| 1302 | Rectangular type with openable circular lid |
| 1303 | 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) |
| 1304 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 1305 | 150 x 100mm size P-type |
| 1306 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1307 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:100 mm diameter |
| 1308 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 1309 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design:100mm dia SWpipe |
| 1310 | GUARD ROOM (INTERNAL ELECTRIFICATION WORKS) |
| 1311 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 1312 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 1313 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 1314 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 1315 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 1316 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 1317 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 1318 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 1319 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 1320 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 1321 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 1322 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
| 1323 | Upto 450 mm sweep |
| 1324 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 1325 | Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver). |
| 1326 | Supply ofSurface mounting round 12 Watt to 15 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect |
| 1327 | Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. |
| 1328 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 1329 | Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect. |
| 1330 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 1331 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN |
| 1332 | Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double Door |
| 1333 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 1334 | Single pole |
| 1335 | Double pole |
| 1336 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 1337 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 1338 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 1339 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 1340 | Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required. |
| 1341 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 1342 | Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: |
| 1343 | 2 Pair (4 core) |
| 1344 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 1345 | 20mm dia PVC conduit |
| 1346 | 25mm dia PVC conduit |
| 1347 | 32mm dia PVC conduit |
| 1348 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required |
| 1349 | 1 or 2 Module (75mmX75mm) |
| 1350 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 1351 | Telephone socket outlet |
| 1352 | Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1353 | Up to 35 sq.mm. |
| 1354 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 1355 | Up to 35 sq.mm. |
| 1356 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 1357 | Upto 35 sq. mm (clamped with 1mm thick saddle |
| 1358 | Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment |
| 1359 | 2 x 10 sq.mm, |
| 1360 | Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. |
| 1361 | 2 X 10 sq. mm (19mm) |
| 1362 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 1363 | 100mm dia |
| 1364 | Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. |
| 1365 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 1366 | ELECTRIC SUB STATION (CIVIL WORKS) |
| 1367 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 1368 | Excavation up to 1.50 mt. |
| 1369 | Level 1.50 mt. to 3.0 mt. depth |
| 1370 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 1371 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 1372 | Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand. |
| 1373 | Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 1374 | Treatment of soil under floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 1375 | (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. |
| 1376 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1377 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1378 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Lintel) |
| 1379 | Same as above for ground floor (Up to Plinth level) |
| 1380 | Same as above for ground floor (Above Plinth level) |
| 1381 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1382 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1383 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Slab) |
| 1384 | Same as above for ground floor |
| 1385 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1386 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1387 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Beam) |
| 1388 | Same as above for ground floor (Tie beam) |
| 1389 | Same as above for ground floor (above plinth level) |
| 1390 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1391 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1392 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Footing) |
| 1393 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1394 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1395 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] (Column) |
| 1396 | Same as above for ground floor (Up to Plinth level) |
| 1397 | Same as above for ground floor (Above Plinth level) |
| 1398 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1399 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate12.5 mm nominal size). |
| 1400 | Painting on D.P.C. with two coats of air blown bitumen VG-10 grade @ 1.7 kg/sqm approximate including cost of fuel if any. |
| 1401 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1402 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 1403 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
| 1404 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
| 1405 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 1406 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate. |
| 1407 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. (25mm thick) |
| 1408 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick |
| 1409 | Providing and fixing glass strips in joints of terrazo/ cement concretefloors. 40 mm wide and 4 mm thick. |
| 1410 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods, gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 1411 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 1412 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats,square or round bars etc. all complete. Fixed to Steel windows by welding |
| 1413 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 1414 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. |
| 1415 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work. (Inner walls) |
| 1416 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 1417 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work. (Ceiling) |
| 1418 | Finishing walls with putty approved brand and manufacturer and of required shade and undacorated wall surface to give even shade over including curing and cost of all material, labour, T & P etc. required for proper completion of work. |
| 1419 | Steel Painting: |
| 1420 | (a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 1421 | (b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 1422 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- |
| 1423 | in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix |
| 1424 | 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 1425 | With average thickness of 120mm and minimum thickness at khurra as 65 mm. |
| 1426 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire |
| 1427 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 1428 | Providing and fixing ball bearing for rolling shutters. |
| 1429 | Providing and laying factory made chamfered edge Cement Concretepaver blocks in footpath, parks, lawns, drive ways or light traffic parkingetc, of required strength, thickness & size/ shape, made by table vibratorymethod using PU mould, laid in required colour & pattern over 50 mmthick compacted bed of sand, compacting and proper embedding/layingof inter locking paver blocks into the sand bedding layer through vibratorycompaction by using plate vibrator, filling the joints with sand and cuttingof paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approvedcolour design and pattern. |
| 1430 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 1431 | Foundations, footings, bases of columns, etc. for mass concrete |
| 1432 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick. |
| 1433 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. |
| 1434 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 1435 | ELECTRIC SUB STATION (ELECTRIFICATION WORKS) |
| 1436 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 1437 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 1438 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 1439 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 1440 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 1441 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 1442 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 1443 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 1444 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 1445 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
| 1446 | Upto 450 mm sweep |
| 1447 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 1448 | Supply of LED 4ft 40W LED Tube light with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 42W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor |
| 1449 | Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver). |
| 1450 | Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required. |
| 1451 | Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, |
| 1452 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. |
| 1453 | 300mm EXHAUST FAN |
| 1454 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 1455 | 4 Way Double door |
| 1456 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 1457 | 40 amps 4P MCB |
| 1458 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 1459 | Single pole |
| 1460 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 1461 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 1462 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 1463 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 1464 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 1465 | Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1466 | Up to 35 sq.mm. |
| 1467 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 1468 | Up to 35 sq.mm. |
| 1469 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 1470 | Upto 35 sq. mm (clamped with 1mm thick saddle |
| 1471 | Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment |
| 1472 | 4 x 10 sq.mm |
| 1473 | Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. |
| 1474 | 4 X 10 sq. mm (25mm) |
| 1475 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 1476 | 100mm dia |
| 1477 | Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. |
| 1478 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 1479 | CC ROAD |
| 1480 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth lead upto 50 metres (DSR-16.1) |
| 1481 | Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. (DSR-4.1.8) Brick edging |
| 1482 | Class 150 brick work in1:6cement and coarse sandof2.30fineness modulus mortar in foundation and plinth including supply ofall materials,labour andtools and plants etc.requiredforpropercompletion of the work. |
| 1483 | Supplying and stacking at site: |
| 1484 | 90 mm to 45 mm size stone aggregate. (DSR-16.3.1) |
| 1485 | 63 mm to 45 mm size stone aggregate (DSR-16.3.2) |
| 1486 | Local Sand @ 25% of Item No. 3a (DSR-2.27) |
| 1487 | Stone screening 11.2 mm nominal size (Type B) (DSR-16.3.7) |
| 1488 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 1489 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . (DSR-16.4) |
| 1490 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. (For temprature reinforcement @ 0.5% of Concrete Volume) (DSR-5.22.6) |
| 1491 | Trimixing of the surface of the cement concrete laid. (M.R.) |
| 1492 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade \"A\" sealing compound. |
| 1493 | INTERLOCKING TILES |
| 1494 | Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. (DSR-2.6.1) |
| 1495 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in foundation and floors. (DSR-4.1.8) |
| 1496 | Class M-150 brick work in 1:6 cement coarse sand (of 2.5 fineness modulus) mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work.(DSR- 6.1.2) |
| 1497 | Providing and laying factory made chamfered edge Cement Concretepaver blocks in footpath, parks, lawns, drive ways or light traffic parkingetc, of required strength, thickness & size/ shape, made by table vibratorymethod using PU mould, laid in required colour & pattern over 50 mmthick compacted bed of sand, compacting and proper embedding/layingof inter locking paver blocks into the sand bedding layer through vibratorycompaction by using plate vibrator, filling the joints with sand and cuttingof paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approvedcolour design and pattern.Cement Grey/Ordinary Red |
| 1498 | KERB STONE WITH K.C. DRAIN |
| 1499 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3(1 cement: 3 coarse sand ) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). (DSR-16.69) |
| 1500 | Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. (DSR-4.1.8) |
| 1501 | Making bell mouth opening/ entrance of size 100x50x50 cm for drainage pipe under footpath, including providing cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) for shape of bell mouth, including plastering providing and fixing precast R.C.C./ S.F.R.C. slab including plastering with cement mortar 1:3 (1 cement : 3 fine sand) of 6 mm thickness on exposed surface of the slab & bell mouth including centring, shuttering & neat cement punning inside the bell mouth etc. all complete. (DSR-16.49) |
| 1502 | Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete. New work (Two or more coats) (DSR-16.47.1) |
| 1503 | LANDSCAPING WORKS |
| 1504 | Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). |
| 1505 | Carrigae of sludge upto 5 K.M. |
| 1506 | Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured instacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm |
| 1507 | Carrigae of manure upto 5 K.M. |
| 1508 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. |
| 1509 | Spreading of sludge, dump manure or/and good earth in requiredthickness (cost of sludge dump manure or/and good earth to bepaid separately). |
| 1510 | Digging holes in ordinary soil and refilling the same with theexcavated earth mixed with manure or sludge in the ratio of 2:1by volume (2 parts of stacked volume of earth after reduction by20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of manure, sludge or extra good earth if needed to be paid for separately). |
| 1511 | Holes 0.9 m dia. and 0.90 m deep. |
| 1512 | Providing & stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. |
| 1513 | Providing & stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35cm as per direction of the officer-in-charge. |
| 1514 | Plantation of trees. (Decorative Plants) |
| 1515 | Tree guard |
| 1516 | Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf. |
| 1517 | EXTERNAL W/S & SEWERAGE WORKS |
| 1518 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 1519 | up to 1.50 m depth |
| 1520 | Pipes 80 mm to 300 mmdiameter |
| 1521 | 1.50 m to 3.00 m depth |
| 1522 | Pipes 80 mm to 300 mmdiameter |
| 1523 | Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) |
| 1524 | Depth not exceeding 1.5 meter |
| 1525 | Depth 1.5 to3.00meter |
| 1526 | Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. |
| 1527 | 150 mm.dia. RCCPipes |
| 1528 | 250 mm.dia. RCCPipes |
| 1529 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 1530 | 150 mm.dia. RCCPipes |
| 1531 | 250 mm.dia. RCCPipes |
| 1532 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. |
| 1533 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 1534 | With common burnt clay FPS (non modular) bricks of class designation 75 |
| 1535 | (i) For Sewer Line |
| 1536 | Extra for depth for manholes: |
| 1537 | Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 1538 | Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg). |
| 1539 | With common burnt clay FPS (non modular) bricks of class designation 75 |
| 1540 | (i) For Sewer Line |
| 1541 | Extra for depth for manholes: |
| 1542 | Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 1543 | Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 1544 | Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling, fixing specials for pressure pipe etc. . (external work) |
| 1545 | 80mm nominal bore. |
| 1546 | 65mm nominal bore. |
| 1547 | 50mm nominal bore. |
| 1548 | 40mm nominal bore. |
| 1549 | 32mm nominal bore. |
| 1550 | 25mm nominal bore. |
| 1551 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. |
| 1552 | 80mm nominal bore. |
| 1553 | 65mm nominal bore. |
| 1554 | 50mm nominal bore. |
| 1555 | 40mm nominal bore. |
| 1556 | 32mm nominal bore. |
| 1557 | 25mm nominal bore. |
| 1558 | Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : |
| 1559 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1560 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design : |
| 1561 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1562 | Supply, Installation, testing & commissioning of Vertical in line pumping setcomplete. The rate shall include the cost of electrical panel and piping work complete |
| 1563 | Domestic Water Supply pumps : |
| 1564 | Capacity/Flow Rate - 12.5 m3/hr |
| 1565 | Head- 45 m |
| 1566 | Location-1 set in UGT (1 set = 2nos(1W+1S)) |
| 1567 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 1568 | Supply, fixing, testing and commissioning of Level Float Switch, for dry run protection of pump as per specifications:- |
| 1569 | Lehry Make Level Float Switch |
| 1570 | 1) Body: Polypropylene, Highly Durable, Water Proof |
| 1571 | 2) Rating : IP68 |
| 1572 | 3) Temperature : 0-50DegC |
| 1573 | 4) Cable : PVC |
| 1574 | Size 5 Mtr, Item Code (LIV-LFV-RED- MTR)(location : UG TANK) |
| 1575 | SEPTIC TANK & SOAK PIT |
| 1576 | Size :- Length = 7.50 M. Width = 2.65M Total Depth =3.00M |
| 1577 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 1578 | In all kind of soil upto 1.5m depth |
| 1579 | In all kind of soil upto 1.5m to 3.0m. depth |
| 1580 | In all kind of soil upto 3.0m to 4.5m. depth |
| 1581 | Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) |
| 1582 | Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) |
| 1583 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 1584 | Suspended floors, roofs, landings, balconies and access platform. |
| 1585 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 1586 | 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) |
| 1587 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 1588 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 1589 | Providing & fixing 75mm dia vent pipes. |
| 1590 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 1591 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 1592 | M.D. -10- Circular shape 500mm internal diameter |
| 1593 | M.D. -2.5- Circular shape 450mm internal diameter |
| 1594 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks |
| 1595 | RAIN WATER HARVESTING |
| 1596 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 1597 | In all kind of soil upto 1.5m depth |
| 1598 | In all kind of soil upto 1.5m to 3.0m. depth |
| 1599 | In all kind of soil upto 3.0m to 4.5m. depth |
| 1600 | In all kind of soil upto 4.5 m to 6.0m. depth |
| 1601 | Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 1602 | Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 1603 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 1604 | Suspended floors, roofs, landings, balconies and access platform. |
| 1605 | Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 1606 | 12mm cement plaster on rough side of single or half brick wall mix |
| 1607 | 1:3 (1 cement : 3 Coarse sand) |
| 1608 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 1609 | With 20x20mm square bar |
| 1610 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 1611 | M.D. -10- Circular shape 500mm internal diameter |
| 1612 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. |
| 1613 | Drilling of 300mm dia bore hole manually. |
| 1614 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 1615 | 150 mm nominal size dia |
| 1616 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 1617 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 1618 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. |
| 1619 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 1620 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 1621 | In all kind of soil upto 1.5m depth |
| 1622 | In all kind of soil upto 1.5m to 3.0m. depth |
| 1623 | Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 1624 | Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 1625 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 1626 | Suspended floors, roofs, landings, balconies and access platform. |
| 1627 | Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 1628 | 15mm cement plaster on rough side of single or half brick wall mix |
| 1629 | 1:3 (1 cement : 3 Coarse sand) |
| 1630 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 1631 | With 20x20mm square bar |
| 1632 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 1633 | M.D. -10- Circular shape 500mm internal diameter |
| 1634 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 1635 | up to 1.50 m depth |
| 1636 | Pipes 80 mm to 300 mmdiameter |
| 1637 | Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. |
| 1638 | 150 mm.dia. RCCPipes |
| 1639 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 1640 | 150 mm. dia. |
| 1641 | Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks |
| 1642 | Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: |
| 1643 | Drain 300 wide average.Depth 45 cm with R.C.C. slab |
| 1644 | Drain 450 wide average.Depth 45 cm with R.C.C. slab |
| 1645 | Supply, installing, testing and commissioning of non clog submersible type drainage / dewatering pumpset |
| 1646 | Product Type: SUBMERSIBLE DRAINAGE PUMPProduct ConfigurationPump Classification: Standard PumpComponent MaterialsVolute Material: Cast Iron FG 260Impeller Material: Cast Iron FG 260Shaft Material: S.S AISI 410Seal Material: Carbon/Ceramic/NBR/S.S 304Motor SpecificationsPhase: 3Voltage: 380-415VCable Length: Standard - 5 metresCable Length: Additional - 0 metres: 0Pipework ConnectionFloat Switch: With Float SwitchSolids Diameter LimitMaximum Solids Diameter: 10 mm Flow Rate = 205 LPM Each Pump Head = 9m Each Pump Set Detail = 1W+1S ( 1No. for UGT) |
| 1647 | EXTERNAL ELECTRICAL WORKS |
| 1648 | H.T. VCB (11KV) ( LOCATED IN METER ROOM) |
| 1649 | Design, manufacturing, testing at works, supplyof HT Panelas per specification and comprising of the following :- |
| 1650 | INCOMER/OUTGOING PANEL |
| 1651 | 630 A Vacuum circuit breaker of 18.3 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, vertical isolation,vermin proof,fully interlocked horizontal drawout type having double isolation. |
| 1652 | Manually and motor operated, spring charged( release closing mechanism) trip free type,triple pole truck mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication.Spring charge/discharge mechanical indicator. |
| 1653 | 630 amp air insulated but encapsulated,PVC insulated Copper bus bars. |
| 1654 | C.T. chamber with C.T.\"s 10/5. |
| 1655 | 15 VA burden for protection (class 5P 10). |
| 1656 | Following protection shall be provided: |
| 1657 | 1 Nos IDMT relay with instantaneous 2 nos. over currrent (50, 50 N) element and 1 no.instantaneous earth fault element(50-50N).(O/C setting 50%-200% and E/F setting 20%-80%) |
| 1658 | All wiring necessary for the above including inter-connections.The size of the conductor should not be less than 2.5 sq. mm. Copper wire where required. |
| 1659 | Test terminal block, fuses/2A SPMCB , circuit labels,set of phase, indication lamps etc. as per standardpractise as under. |
| 1660 | Red - Breaker close (ON) |
| 1661 | Green - Breaker open (OFF) |
| 1662 | Amber - auto trip |
| 1663 | Clear - trip circuit healthy |
| 1664 | Blue spring charged |
| 1665 | Control :- T-N-C(Trip, Neutral. Close) breaker control switch with indication arrangement. |
| 1666 | Terminal boxes with single gland trifucating cable box suitable for 11 KV Aluminium XLPE (E) cable of size 3C x 70 Sq. mm. for incoming/outgoingbreaker. |
| 1667 | HT Danger Plate.(as per IS specification) |
| 1668 | 2 Runs of 40 X 5 mm earth bus shall be provided for the full length of the panel. |
| 1669 | Power Pack, Battery power pack shall be rated for minimum five (5) trippings.For DC power one no. source selector switch to be incorporated i.e. one source from power pack and other from outside. |
| 1670 | Necessary D.C. supply healthy indication lamp (White Colour), switch with alarm. |
| 1671 | Surge supressor as required. |
| 1672 | DC Voltmeter, 0-10 Volt, Digital type. |
| 1673 | HT Panel switchboard complete with all interconnections, labels, wiring etc, complete as described above in item nos.A and B and asper specifications. |
| 1674 | Supply of 3 core stranded aluminium conductor 11KV grade XLPE (E) (Cross linked Polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cable confirming to IS : 7098 (part II with latest amendments). |
| 1675 | 70 sq. mm 3 core |
| 1676 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1677 | Upto 120 sq. mm |
| 1678 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 1679 | Upto 120 sq. mm |
| 1680 | Supply and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core 70Sq.mm. XLPE aluminium conductor cable of 11 kV grage as required. |
| 1681 | Supply and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core 70 Sq.mm. XLPE aluminium conductor cable of 11 kV grage as required. |
| 1682 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB\"s (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. |
| 1683 | Main LT Panel |
| 1684 | Incoming : |
| 1685 | 2 No 630 Amp. 4P MCCB of 35KA (Ics=Icu)Breaking Capacity |
| 1686 | Metering : |
| 1687 | 1 Set of CT\"s one of 630/ 5Amp ratio for Multifunction Meter |
| 1688 | 1 Set of CT\"s one of 630/ 5Amp ratio 27,47,59,81. |
| 1689 | 1 Set of CT\"s one of 200/ 5Amp ratio for APFC relay. |
| 1690 | 1 Set of Phase Indication Lamp. |
| 1691 | Bus Bar : |
| 1692 | One (1) No. 800 Amp. FP aluminimum bus bar of suitable length. |
| 1693 | Outgoing : |
| 1694 | Phase indication lamps on each outgoing to be provided. |
| 1695 | 500 Amps TPN MCCB of 35KA -2 No |
| 1696 | 200 Amps TPN MCCB of 35KA -1 No |
| 1697 | 63 Amps TPN MCCB of 35KA -2 No |
| 1698 | 40 Amps TPN MCCB of 35KA -1 No |
| 1699 | 32 Amps DP MCB of 10KA -2 No |
| 1700 | 2 No. SPACE & SPARE |
| 1701 | Panel described as above |
| 1702 | FEEDER PANEL -1 |
| 1703 | INCOMING |
| 1704 | 1No. Of 500 Amps FP MCCB of 35KA breaking capacity |
| 1705 | Metering : |
| 1706 | 1 Set of CT\"s one of 500/ 5Amp ratio for Multifunction Meter |
| 1707 | One (1) Set of Phase Indication Lamp. |
| 1708 | BUS BAR |
| 1709 | 1 Set of 600 Amps TPN Aluminium Bus Bars |
| 1710 | OUTCOMING |
| 1711 | 400 Amps FP MCCB of 35KA - 2 No |
| 1712 | 63 Amps FP MCCB of 25KA - 2 No |
| 1713 | 25 Amps DP MCB of 10KA -2 No |
| 1714 | 10 Amps DP MCB of 10KA - 6 No |
| 1715 | Timer switch - 6 No |
| 1716 | 2 No. SPACE & SPARE |
| 1717 | Panel described as above |
| 1718 | CAPACITOR PANEL-60 KVAR |
| 1719 | SITC APFC Panel of 60 KVAR capacity suitable for operation on 415 + 5% Volt, 3 Phase, 50Hz, AC supply, having MPP type, resin bounded, static5,10,15,25 KVAR capacitors (without oil) in tier formationcomplete with following TPN MCCBas incomer of the panel, 4 step microprocessor based power factor controller relay capable to select the rating from 1 KVAR to multiples thereon up to max rating of the panel, current limiting contactors for each capacitors protected with MCBs, Ammeter (Analogue type) with CTs, Voltmeter (Analogue type) selector switches indicating lights, cooling fans for panel, earthing the panel with 2 Nos. 25mm x 5mm thick GI steel flat from existing earth bar, connection of APFC panel with suitable size 3.5 core aluminium conductor armoured XLPE cable from main LT panel (maximum length of cable 10 mtrs.) and compression glands etc. as reqd. |
| 1720 | The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part automatically as and when requried. Capacity of Static capacitors should be accommodated from the overall rating of the panel and should be designed to switch in |
| 1721 | independently. The panel should be manufactured with 1.6mm thick CRCA sheet duly powder coated. |
| 1722 | Incoming |
| 1723 | One (1) No 200 Amp. 4P MCCB of 25 KABreaking capacity |
| 1724 | BUS BAR |
| 1725 | 1 Set of 250 Amps TPN Aluminium Bus Bars |
| 1726 | OUT GOING |
| 1727 | 01 No. 63 Amps. TP MCCB (25 KA)-25 KVAR |
| 1728 | 01 No. 40 Amps. TP MCCB (25 KA)- 15 KVAR |
| 1729 | 02 No. 32 Amps. TP MCCB (25 KA) - 10 KVAR |
| 1730 | Panel described as above |
| 1731 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 1732 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 1733 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 1734 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 1735 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 1736 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 1737 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 1738 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 1739 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 1740 | Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1741 | Up to 35 sq.mm. |
| 1742 | Above 185 sq.mm. and up to 400 sq.mm. |
| 1743 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 1744 | Up to 35 sq.mm. |
| 1745 | Above 185 sq.mm. and up to 400 sq.mm. |
| 1746 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 1747 | Upto 35 sq. mm (clamped with 1mm thick saddle |
| 1748 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp |
| 1749 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 1750 | Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment |
| 1751 | 3.5 x 300 sq.mm. |
| 1752 | 3.5 x 240 sq.mm. |
| 1753 | 3.5 x 185 sq.mm |
| 1754 | 3 x 6 sq.mm, |
| 1755 | Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. |
| 1756 | 2 X 6 sq. mm (19mm) |
| 1757 | 3½ X 185 sq. mm (57mm) |
| 1758 | 3½ X 240 sq. mm (62mm) |
| 1759 | 3½ X 300 sq. mm (70mm) |
| 1760 | Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required |
| 1761 | 100 mm dia |
| 1762 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 1763 | 100mm dia |
| 1764 | 150 mm dia |
| 1765 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 1766 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 1767 | ProvidingandfixingHT danger notice plate 250 mm x 200 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required. |
| 1768 | Supplying andFixing of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge. |
| 1769 | Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd. |
| 1770 | Supply and fixing of fire extinguishers, ABC Type 9.00 kg. capacity(ISI Marked IS : 15683 & TAC approved)complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 1771 | Supply and fixing of CO2 typefire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved)complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 1772 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : |
| 1773 | With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 |
| 1774 | Supplying, installation & testing of 7.0 m high octagonal GI pole with single arm as per approved sample made from 3 mm sheet steel (Grade S 355 J0) with top diameter as 75mm and bottom dia as 150mm and base plate of 240x240x16 mm with suitable slot shaped holes for mounting the same on a shallow foundation, GI weather proof junction box with 16A SP MCB, loop-in-loop out terminals for 2nos. 2Cx6 sq.mm YWY cables and 2x2.5 sq.mm copper conductor from junction box to fitting and connected accessories as required etc. |
| 1775 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 45Watt. to 50 Watt andConfirming to IP66 protectionhaving Company LOGO Engravedcomplete in all respect with 4000-5000 system lumens High Power LED with lenses, >110lm/W, PF>0.95, THD <10% at full load, CRI>70, Avg Life Class 50000Hrs@L70,fitting itself suitable for 60-65mm OD pipe |
| 1776 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 1777 | Double pole |
| 1778 | Supply and fixing of LED Gate light fitting having die cast aluminium body and diffuser with driver set suitable for 6 watt to 10 watt. Confirming to IP 54 and above protection complete in all respect. |
| 1779 | Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 1 output per phase and suitable for single phase supply |
| 1780 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 6.5 metre and upto 8.0 metre |
| 1781 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required |
| 1782 | 32 mm dia |
| 1783 | EXT. FIRE FIGHTING FOR AUDITORIUM |
| 1784 | Providing laying, testing & commissioning of \"C\" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (EXTERNAL WORKS) |
| 1785 | 100 mm dia. |
| 1786 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 1787 | 100 mm dia. |
| 1788 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 1789 | 100 mm dia. |
| 1790 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required : |
| 1791 | 2 way - 100 mm dia M.S. Pipe (Siamese Connection) |
| 1792 | BORING & SUBMERSIBLE PUMP |
| 1793 | Transportation Charges of drilling equipment including assembly and other material as required. |
| 1794 | Drilling of 675 mm. dia by rotary machine |
| 1795 | Supply & laying of 350 mm. dia housing pipe (8 mm. thick) |
| 1796 | Supply & laying of 200 mm. dia blind pipe (8 mm. thick) |
| 1797 | Supply & laying of 200 mm. dia slotted pipe (8 mm. thick) |
| 1798 | Supply & fixing of 350 mm. dia Socket |
| 1799 | Supply & fixing of 200 mm. dia Socket |
| 1800 | Supply & fixing of 200 mm. dia Bail plug |
| 1801 | Supply & fixing of 350 mm. dia well cap |
| 1802 | Supply & fixing of 350x200 mm. dia reducer. |
| 1803 | Supply & fixing of 350 mm. dia housing clamp |
| 1804 | Supply & Filling of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of E/I. |
| 1805 | Development by air compressor including Transportation. |
| 1806 | Development by O.P. Unit including Transportation. |
| 1807 | Supply of submersible pump suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with electric moter operating of 415 volt suitable for 3 phase 50 cycle A.C. Supply of following duty condition: |
| 1808 | A - Discharge of water in LPM 860 Approx size of discharge outlet in 80 mm. |
| 1809 | B - Total Head of pump set 45 m. |
| 1810 | Supply and fixing of finolex or equivalent ISI marked submersible copper cable of size 2x3x2.5 sq. mm. |
| 1811 | Supply of control panel cubical type wall mounted vermin proof with internal wiring duly enameled painted and mechanically finished having L&T of qul. Male switch fuse unit with HRC fuses, Ameter, Boltmeter, Selector switch, phase indicating lamp with bulbs, instrument fuses, power capcitor single phase preventor etc. complete set with supply of Jyoti or eq. Air break Star- Delta motro starter suitable for above submersible pump set. |
| 1812 | Supply of 80mm dia M.S. column pipe of class \"C\" both and socketed with heavy sockets in 3/6 meter length and one end flanged complete with interlocking arrangements. |
| 1813 | Supply of 80mm dia M.S. column pipe clamps with nut, bolts, packing etc. |
| 1814 | Supply of 80mm dia C.I. double flanged ISI mark reflex valve of updadhya or equ. Make. |
| 1815 | Supply of 80mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make. |
| 1816 | Supply of C.I. double flanged bend of 80mm dia i/c cost of material and labour. |
| 1817 | Supply of 80mm dia C.I. tee heavy quality i/c cost of material. |
| 1818 | Supply of Guru/Fibing or equivalent make pressure gauge. |
| 1819 | Erection & commissioning of pumping plants complete along with electric wiring. |
| 1820 | Supply of steel wire rope of 1/2\" size |
| 1821 | S/B of 600mm x 600 mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead on one no. 8 to 10 SWG GI wite in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. , pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal. coke and salt at least 150mm thick alround etc. as per directions of E/I complete in all respects as per drawing. |
| 1822 | S/F of one number 8 to 6 SWG G.I. wire in 15mm dia G.I. Pipe for earthing, laid in ground or in wall duly concealed includingn the cost of cement, sand labour. T&P other material required for proper completion of the work as directed at site. |
| 1823 | S/F of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 volts grade at a depth of 750mmbelow ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top.On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by E/I complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sqmm x 4 core |
| 1824 | BOUNDARY WALL WITH RETAINING WALL - 2.0 MT. |
| 1825 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 1826 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 1827 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 1828 | Above plinth level |
| 1829 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 1830 | Up to plinth level |
| 1831 | Above plinth level |
| 1832 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size) |
| 1833 | R.C.C. Work in footing |
| 1834 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 1835 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1836 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1837 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class -150in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 1838 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 1839 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand). |
| 1840 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Fabricationof grill / railing. |
| 1841 | Steel Painting: |
| 1842 | (a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 1843 | (b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 1844 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 1845 | Finishing walls with putty approved brand and manufacturer and of required shade and undacorated wall surface to give even shade over including curing and cost of all material, labour, T & P etc. required for proper completion of work. |
| 1846 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 1847 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick. |
| 1848 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 1849 | Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 1850 | BOUNDARY WALL WITH RET. WALL - 5.36 MT. DEPTH |
| 1851 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 1852 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 1853 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).Above plinth level |
| 1854 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 1855 | Up to plinth level |
| 1856 | Above plinth level |
| 1857 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size) R.C.C. Work in footing |
| 1858 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 1859 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1860 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1861 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class -150in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 1862 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 1863 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand). |
| 1864 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Fabricationof grill / railing. |
| 1865 | Steel Painting: |
| 1866 | (a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 1867 | (b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 1868 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 1869 | Finishing walls with putty approved brand and manufacturer and of required shade and undacorated wall surface to give even shade over including curing and cost of all material, labour, T & P etc. required for proper completion of work. |
| 1870 | Geosynthetic Drainage with two filtering nonwoven geotextiles having a “W” configuration as longitudinal parallel channels. Minimum thickness to be 7.2 mm, with two filtering UV stabilized polypropylene nonwoven geotextile of minimum thickness of 0.75 mm having pores of 150 micron and tensile strength of 8.0 kN/m and having plane flow capacity of 2.1 L / (m.s) at hydraulic gradient of 1.0 & 20 kPa pressure,tensile strength of 18 kN/m , with mass per unit area of 740gsm. |
| 1871 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 1872 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick. |
| 1873 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 1874 | Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 1875 | 6.0 MT. WIDE M.S. GATE (2 Nos.) |
| 1876 | Earth workinexacavationin trenches forfoundationsand for pipes cables etc. in ordinary soil(loan clay or sand) including liftupto1.5 m and dressing ofsidesandrammingofbottom sand disposal ofsurplusexcavated earth as directed by the Engineer i/c withina lead of 50m. |
| 1877 | Providing and layingin cement concrete 1:4:8 (1 cement :4 fine sand :8 graded stone ballast 40 mm nominal size) and curing complete, including cost ofform-work,in foundation and floors. |
| 1878 | R.c.c. workwith cement approved coarse sandand2cm. (3/4\") guageapproved stoneballastin the proportion 1:1.5:3 in R.C.C. Footing excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire andexcludingnecessary centering and shuttering etc.and also including supply of all materials,labour andtoolsand plants etc,required for proper completion of the works.strength of the concrete shall not be less than M-200. |
| 1879 | R.c.c. workwith cement approved coarse sandand2cm. (3/4\") guageapproved stoneballastin the proportion 1:1.5:3 in Beam excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire andexcludingnecessary centering and shuttering etc.and also including supply of all materials,labour andtoolsand plants etc,required for proper completion of the works.strength of the concrete shall not be less than M-200.Up to plinth lvl. |
| 1880 | As in item 3 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-150. |
| 1881 | Up to plinth lvl. |
| 1882 | Above plinth lvl. |
| 1883 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 1884 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand). |
| 1885 | Finishingwallswith water-proofing on cementpaint of approvedmakesuch as super snowcem, durrocem, robiacem, guttucem supercem qualityandof required shade on undecorated wall surfaces(two coat) overone andincludingonecoatwhite cementprimertogiveaneven shade after thoroughly brushing the surface to powdered materialsincluding curing and cost of all materials. |
| 1886 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 1887 | Steel Painting: |
| 1888 | (a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 1889 | (b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 1890 | Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 1891 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 1892 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick. |
| 1893 | Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 1894 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 1895 | GATE COMPLEX WITH GUARD ROOM (CIVIL WORK) |
| 1896 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 1897 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone ballast 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 1898 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1899 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1900 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156] |
| 1901 | Same as above for ground floor (Up to Plinth level) |
| 1902 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1903 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1904 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156](Slab) |
| 1905 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1906 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1907 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156](Beam) |
| 1908 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1909 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1910 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156](Column) |
| 1911 | Same as above for ground floor (Up to Plinth level) |
| 1912 | Same as above for ground floor (Above Plinth level) |
| 1913 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 1914 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 1915 | Concrete of M25 grade with minimum cement content of 330 kg /cum. For 362 kg/Cum [For M-30 32 Kg X 5.156](Footing) |
| 1916 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1917 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1918 | Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 1919 | Steel Painting: |
| 1920 | (a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 1921 | (b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 1922 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 1923 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Red sand stone - Exposed face fine dressed with rough backing.60 mm thick |
| 1924 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 1925 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate. |
| 1926 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work. |
| 1927 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 1928 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 1929 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 1930 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 1931 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 1932 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 1933 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 1934 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats,square or round bars etc. all complete. Fixed to Steel windows by welding |
| 1935 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 1936 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 1937 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 1938 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 1939 | Foundations, footings, bases of columns, etc. for mass concrete |
| 1940 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick. |
| 1941 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. |
| 1942 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 1943 | GATE COMPLEX WITH GUARD ROOM (PLUMBING WORK) |
| 1944 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 1945 | White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 1946 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 1947 | White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap |
| 1948 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 1949 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 1950 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 1951 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 1952 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink) |
| 1953 | 15 mm nominal bore |
| 1954 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 1955 | 45 cm length |
| 1956 | 15 mm nominal bore |
| 1957 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 1958 | 15mm nominal bore |
| 1959 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 1960 | Concealed work, including cutting chases and making good the walls etc. |
| 1961 | For Internal Toilet |
| 1962 | 15 mm nominal outer dia Pipes |
| 1963 | 20 mm nominal outer dia Pipes |
| 1964 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 1965 | Internal work - Exposed on wall |
| 1966 | 20 mm nominal bore |
| 1967 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall |
| 1968 | Terrace loop & Tank Filling Pipe |
| 1969 | 25 mm nominal bore |
| 1970 | Providing , checking, storing, fixing in positionof approvedqualityScrewed ends Brass float valvewith brassballfloatandPTFE seat suitable forBody test pressure of 15Kg/sqcm of the following sizes: |
| 1971 | 25mm |
| 1972 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : |
| 1973 | 25mm diameter pipe |
| 1974 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 1975 | 25 to 40 mm nominal bore |
| 1976 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 1977 | For vertical pipe connection with terrace ringmain |
| 1978 | 20 mm nominal bore |
| 1979 | 25mm nominal bore |
| 1980 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 1981 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 1982 | 110 mm dia (for rain water) |
| 1983 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. |
| 1984 | Single Push Fit Coupler |
| 1985 | 110 mm dia |
| 1986 | Single tee with door |
| 1987 | 110x110x110 mm |
| 1988 | Plain bend 87.5 deg |
| 1989 | 110 mm dia |
| 1990 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 1991 | 110 mm dia |
| 1992 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 1993 | Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. |
| 1994 | Internal Toilet (Soil & Waste Pipe) |
| 1995 | 75 mm |
| 1996 | 110 mm |
| 1997 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. |
| 1998 | Bend without door (45°) |
| 1999 | 75mm |
| 2000 | Y\" Fitting without door |
| 2001 | 75mm |
| 2002 | Single Tee without door |
| 2003 | 75 mm |
| 2004 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. |
| 2005 | For Wash basin & Urinal |
| 2006 | 32mm dia. Pipe (for wash basin & sunken toilet spout) |
| 2007 | Elbow (90°) |
| 2008 | 32mm |
| 2009 | Elbow (45°) |
| 2010 | 32mm |
| 2011 | T fitting |
| 2012 | 32mm |
| 2013 | Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 2014 | 110mm x 75mm x 50mm/40mm (Toilet) |
| 2015 | Providing and fixing PTMT grating of approved quality and colour. |
| 2016 | Rectangular type with openable circular lid |
| 2017 | 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) |
| 2018 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 2019 | 150 x 100mm size P-type |
| 2020 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 2021 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: |
| 2022 | 100 mm diameter |
| 2023 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 2024 | All kind of soil |
| 2025 | Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 2026 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: |
| 2027 | 100mm dia SWpipe |
| 2028 | GATE COMPLEX WITH GUARD ROOM (ELECTRIFICATION WORK) |
| 2029 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2030 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 2031 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 2032 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 2033 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 2034 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 2035 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 2036 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 2037 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 2038 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 2039 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 2040 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
| 2041 | Upto 450 mm sweep |
| 2042 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 2043 | Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver). |
| 2044 | Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 2045 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 2046 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN |
| 2047 | Supply, Installation, Testing and Commissioning of LED RGB/RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/ Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270V AC, 50Hz with power factor>0.9. Fixtureshallbesuitabletooperateatanambienttemperaturerangeof-10°Cto+50°CandshallbeIP65andIK06rated.LifetimeshallbeatleastL70:50000burninghoursat50°C.LuminaireshallbeconformingtoBIS(IS10322)andshallbecompletewithallnecessaryaccessoriesrequiredforproperworkingoffixtureincludingweatherproofconnectioncables,waterproofconnectorsetc. as required.45W /40W |
| 2048 | Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door |
| 2049 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 2050 | Single pole |
| 2051 | Double pole |
| 2052 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 2053 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 2054 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 2055 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 2056 | Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required. |
| 2057 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 2058 | Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: |
| 2059 | 2 Pair (4 core) |
| 2060 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 2061 | 20mm dia PVC conduit |
| 2062 | 25mm dia PVC conduit |
| 2063 | 32mm dia PVC conduit |
| 2064 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required |
| 2065 | 1 or 2 Module (75mmX75mm) |
| 2066 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 2067 | Telephone socket outlet |
| 2068 | Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 2069 | Up to 35 sq.mm. |
| 2070 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 2071 | Up to 35 sq.mm. |
| 2072 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 2073 | Upto 35 sq. mm (clamped with 1mm thick saddle |
| 2074 | Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment |
| 2075 | 2 x 10 sq.mm, |
| 2076 | Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. |
| 2077 | 2 X 10 sq. mm (19mm) |
| 2078 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 2079 | 100mm dia |
| 2080 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 2081 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 2082 | 75 K.L. FIRE & DOMESTIC U.G. WATER STORAGE TANK |
| 2083 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 2084 | 0.0 TO 1.50 Mtr |
| 2085 | 1.50 TO 3.0 Mtr |
| 2086 | 3.0 TO 4.50 Mtr |
| 2087 | 4.50 TO 6.00 Mtr |
| 2088 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 2089 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 2090 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 2091 | All works upto plinth level, Concrete of M30 grade with minimum cement content of 350 kg /cum. For 398 kg/Cum [For M-30 48 Kg X 5.156] (Lintel) |
| 2092 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 2093 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 2094 | All works upto plinth level, Concrete of M30 grade with minimum cement content of 350 kg /cum. For 398 kg/Cum [For M-30 48 Kg X 5.156] (Beam) |
| 2095 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 2096 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 2097 | All works upto plinth level, Concrete of M30 grade with minimum cement content of 350 kg /cum. For 398 kg/Cum [For M-30 48 Kg X 5.156] (Slab) |
| 2098 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 2099 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 2100 | All works upto plinth level, Concrete of M30 grade with minimum cement content of 350 kg /cum. For 398 kg/Cum [For M-30 48 Kg X 5.156] (Footing) |
| 2101 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improvedurability and workability without impairing strength; including pumping of concrete tosite of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering,finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete. |
| 2102 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement. |
| 2103 | All works upto plinth level, Concrete of M30 grade with minimum cement content of 350 kg /cum. For 398 kg/Cum [For M-30 48 Kg X 5.156] (R.C.C. Wall/Column) |
| 2104 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 2105 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 2106 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 2107 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) |
| 2108 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster |
| 2109 | Supply & fixing of flush doors commercial quality conforming to IS : 2202 Part I (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally. (a) 35mm thick |
| 2110 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 2111 | Providing & fixing of hold fast for chaukhatsof doors and windows. |
| 2112 | Providing & fixing of door / windows grill. |
| 2113 | Z-Section steel windows |
| 2114 | Angle iron door chaukhat 40*40*5 |
| 2115 | Fixing of Door, windows/ventilators chaukhats in position. |
| 2116 | Door |
| 2117 | Window |
| 2118 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) |
| 2119 | Finishing walls with water-proofing on cement paint of approved make such as super snowcem, durrocem, robiacem, guttucem, supercem quality and of required shade on undecorated wall surfaces (two coat) overone and including one coat white cement primer to give an even shade after thoroughly brushing the surface to powdered materials including curing and cost of all materials. |
| 2120 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Ceiling) |
| 2121 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 2122 | (a) 250 mm x 10mm |
| 2123 | (a) 200 mm x 10mm |
| 2124 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm |
| 2125 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 2126 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 2127 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to |
| 2128 | IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick |
| 2129 | jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including l |
| 2130 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. |
| 2131 | iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) |
| 2132 | Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @ 0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. |
| 2133 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade |
| 2134 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete40 mm thick with 20 mm nominal size stone aggregate, |
| 2135 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 2136 | Suspended floors, roofs, landings, balconies and access platform. |
| 2137 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 2138 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 2139 | PUMP ROOM (ELECTRIFICATION WORKS |
| 2140 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2141 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 2142 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 2143 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 2144 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 2145 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as requiredUpto 450 mm sweep |
| 2146 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 2147 | Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver). |
| 2148 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN |
| 2149 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 2150 | SUBHEAD - V :D.G. SETS |
| 2151 | Supplying, Installation and commissioning of AMF start silent type225 KVA DG set comprising of suitable BHPdiesel engine directly coupledto 3 phase 50 Hz 415 V alternator of 225 KVA rating at 0.8 power factor mounted on a common base frame, complete in all respects with all required safety devices, fittings, batteries, accessories, filters, residential type silencer, control panel, inbuilt diesel oil MS tank of 990 ltrs. capacity made of 2mm thick M.S. sheet complete with M.S. fuel piping, G.M. gate valves, supports, control cable between generating set and control panel, exhaust piping with asbestos roping, antivibration mounting pads, first filling of lubricant oil totally enclosed in air tight, dust proof, weather proof, powder coated cubical type, sound proof as per |
| 2152 | CPCB norms acoustic enclosure made of 2mm thick CRCA sheet with with heavy duty doors, lockable arrangement, sound proof insulation with high density rock/mineral polymer/fibre cloth and perforated CRCA sheets, suitable to reduce the sound level upto 75dba approx. at a distance of 1 mtrs. as per CPCB norms |
| 2153 | AMF Panel Incoming-630 Amps FP MCCB of 35KA breaking capacity and contactor same rating |
| 2154 | FURNITURE |
| 2155 | ARISTO TABLE 2100 LH RU 1200 PDL 2100x2250x750 All specification as per standard & detailed estimate. |
| 2156 | ACE WITH HEADREST CHAIR Active Bio-Synchro Mech,Bio-Flex Lumbar Support, Seat Slide Mech, Die cast polished Aluminum Pedestal, Adj Arms, 5 Position Tilt Limiter. All specification as per standard & detailed estimate. |
| 2157 | (a) ACE Full Back |
| 2158 | (b) Headrest |
| 2159 | ACE - Visitor Chair Bio-Flex Lumber Support, MS Powder Coated U/S, Adj Arms. All specification as per standard & detailed estimate. |
| 2160 | PARTO Pl 3Str Sofa SLthr Blk Overall Size :Width: 175cm Depth : 87cm Height : 76cmSeating Height : 39.5cm. All specification as per standard & detailed estimate. |
| 2161 | Bloom Coffee Table Walnut Overall Size :Width: 100cm Depth : 65cm Height : 43cm. All specification as per standard & detailed estimate. |
| 2162 | Adriana Single Bed Walnut Overall Size :Length : 206cm Width : 113.1cm Bed Height : 41cmBed with Headboard Height : 93cm, All specification as per standard & detailed estimate. |
| 2163 | Ortho Plus Mattress 78 36 4 Thickness: 10 cm / 12.5 cm, All specification as per standard & detailed estimate. |
| 2164 | Pillow Nice L:425mm W:675mm Size ( in cm) : 43 x 69, All specification as per standard & detailed estimate. |
| 2165 | Manager Module Workstation, All specification as per standard & detailed estimate. |
| 2166 | PULSE Mb Seat Chair, Adj. Arms Larger Seats Lumber Pad, Adj Seat Height, Back tilt Tension,Recline Lock, Nylon Pedestal, KTS Mechanism 4 Positon Locking, All specification as per standard & detailed estimate. |
| 2167 | ECHO HDU size : 900 X 740 X 450, All specification as per standard & detailed estimate. |
| 2168 | Grande 4 Seater, All specification as per standard & detailed estimate. |
| 2169 | Grande Dining chair, All specification as per standard & detailed estimate. |
| 2170 | Squadro V2 King Bed Cinmon Overall Size :Length : 205.3cm Width : 187.5cm Bed Height : 42.3Bed with Headboard Height :113.3cm, All specification as per standard & detailed estimate. |
| 2171 | Squadro Bedside Table Cinnamon Overall Size :Width : 61cm Depth : 45.5cm Height : 50.35cm, All specification as per standard & detailed estimate. |
| 2172 | Accupadic Mattress 78 72 5 Thickness: 12.5 cm / 15 cm, All specification as per standard & detailed estimate. |
| 2173 | Orlando P 1str sofa Plthr Brwn Overall Size :Width: 92cm Depth : 92cm Height : 89cmSeating Height : 47.5cm, All specification as per standard & detailed estimate. |
| 2174 | Bloom Corner Table Walnut Overall Size :Width : 60cm Depth : 60cm Height : 45cm, All specification as per standard & detailed estimate. |
| 2175 | Nebula sofa 3+1+1 Nebula V3 1str Sofa fab Grey Overall Size : Width: 101cmDepth : 97.5cm Height : 93cmSeating Height : 46cm, All specification as per standard & detailed estimate. |
| 2176 | Nebula V3 3str Sofa fab Grey Overall Size :Width: 231cmDepth : 97.5cm Height : 93cmSeating Height : 46cm, All specification as per standard & detailed estimate. |
| 2177 | Arbor coffee table in Remini Walnut Dimensions W x H x D (cm)-120 x 45 x 60, All specification as per standard & detailed estimate. |
| 2178 | Arbor side table in Remini Walnut Dimensions W x H x D (cm)-80 x 45 x 37.5, All specification as per standard & detailed estimate. |
| 2179 | Elixir DinTable 4Str Marble Overall Size :Width : 136cm Depth : 136cm Height : 78.5cm, All specification as per standard & detailed estimate. |
| 2180 | Opulent Adv Dining Chair Beige Overall Size :Width : 33.5cm Depth : 43.5cm Height : 88.5cm, All specification as per standard & detailed estimate. |
| 2181 | MERAKI Media Unit Brn/Beige Overall Size :Width : 180.4cm Depth : 49.5cm Height : 50.4cm, All specification as per standard & detailed estimate. |
| 2182 | CIGNUS TABLE 1650 LH RU 1200 PDL 1650x1950x750, All specification as per standard & detailed estimate. |
| 2183 | PULSE CHAIR WITH HEADRESTAdj Neck rest & lumber Pad, Seat Height, Back tilt Tension,Recline Lock, Nylon Pedestal, KTS Mechanism 4 Positon Locking , All specification as per standard & detailed estimate. |
| 2184 | (a) Mb Seat, Adj. Arms Larger Seats , All specification as per standard & detailed estimate. |
| 2185 | (b) Neck Rest Adj. Chair, All specification as per standard & detailed estimate. |
| 2186 | OXBO - Visitor Fixed PP Arms,Tubular frame structure, All specification as per standard & detailed estimate. |
| 2187 | Upbeat 8 seater, All specification as per standard & detailed estimate. |
| 2188 | OXBO - Mid Back chairCT Mech Upright Position Locking, Fixed PP Arms, Nylon Ped, All specification as per standard & detailed estimate. |
| 2189 | RDNC SR1 MTL SW 1200mm 300mm 1200W X 300D X 2078H, All specification as per standard & detailed estimate. |
| 2190 | RDNC DR1 MTL SW 1200mm 600mm 1200W X 600D X 2078H, All specification as per standard & detailed estimate. |
| 2191 | MINGLE MODULAR MEETING TABLE PLT(90 SEATER), All specification as per standard & detailed estimate. |
| 2192 | BEAT (LC) - High Back Chair With Seat Slide KTS Mech 4 Position Locking, Chrome Pedestal, Chrome-platting element in PU-up-down adj arms & Ht. Adj Backrest, All specification as per standard & detailed estimate. |
| 2193 | BEAT (LC) - Mid Back ChairWith Seat Slide KTS Mech 4 Position Locking, Chrome Pedestal, Chrome-platting element in PU-up-down adj arms & Ht. Adj Backrest, All specification as per standard & detailed estimate. |
| 2194 | Majesta P 2Str sofa Leather Ch Overall Size :Width : 1520mm Depth : 840mm Height : 760mm, All specification as per standard & detailed estimate. |
| 2195 | Majesta P 3Str sofa Leather Ch Overall Size :Width : 1820mm Depth : 840mm Height : 760mm, All specification as per standard & detailed estimate. |
| 2196 | Meraki coffee table Brow/Beige Overall Size :Width : 120cm Depth : 60cm Height : 36.7cm, All specification as per standard & detailed estimate. |
| 2197 | Meraki corner table Brown Overall Size :Width : 60cm Depth : 60cmHeight : 49.8cm(With Bush), All specification as per standard & detailed estimate. |
| 2198 | LIFT FOR GUEST HOUSE |
| 2199 | LIFT with power operated centre opening doors and AC variable voltage & variable frequency controls (travel height G+4)8 PASSENGERS CAPCITY, All specification as per standard &work execution as per detailed estimate. |
| 2200 | GST Extra as applicable |