| 1 | Dismantling oldposts or struts (wood, steel or RCC) embededed in Concrete, brick work, masonry, etcany section, including taking out embedded portion including necessary excavation &prepration of postholesand removal of surplus excavated material from site complete all as specified and directed. |
| 2 | M&L for Cement Concrete type D-2, 1:4:8 using 40mm graded agregate asin foundations, filling and mass concrete complete all as specified and directed. |
| 3 | S&F for mild steel angle, flat iron as in post & strut including cutting tops to shape,drilling holes, notching for wire, incl flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and nosing to steps including embeding in concrete etc or similar work conforming to Fe 290 Gde 165 complete all as specified and directed. |
| 4 | Fixing only old dismantled steel posts / struts including embeding in concrete etc complete all as specified and directed. |
| 5 | Dismantling of fencing wire mesh barbed wire,chain linketc, complete all as specified and directed. |
| 6 | Supply onlyGalvanized chain link fencing of any size any type confirming to relevent IS including line wires, any mesh, size and type, fixed to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed. |
| 7 | Fixing only chain link fencingincluding line wirers ,any mesh any type of standerds,rails ,straining boltsetc including provn of binding wire complete all as specified |
| 8 | S&F in repair Mild steel Round bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specifierd and directed |
| 9 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and directed. |
| 10 | Dismantling mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 11 | S&F for Framed work such as in door frame, door shuters / gate of angel, flat Iron, plates or other section incl preparation for fixing of steel sheeting or other convering doors to be prepared for hangingincluding hinges, hold fast , handles , locking arrangement and all necessary requiredfittings of Fe 410-W (Gde E-250 quality - B) etc complete all as specified. |
| 12 | M&L for two coat of synthetic enamel paint (finishing coat) over one coat of primer to newsteel surfaces of any description over 10 cm width or girth incl prepration of surfaces complete all as specified & directed. |
| 13 | Demolition of precast concrete block masonry work for ashlar facings,dressed stonework,precast concrete articlesand precast concrete block walling built in cement mortar or cement lime motar completed all as specified and directed. |
| 14 | M&L precast cementconcrete block masonrytype C1 (1:3:6) using 20 mm graded aggregate with solid block, exc. 10 Cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 15 | M&L for preparation of newly plastered surfaces of walls including cornices, pillasters etc, and applying two coats of cement base paint over and including one coat of white wash complete all as specified and directed. |
| 16 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 17 | M&L for 75 mm thick cement concrete type E-21:5:10 (40mm graded aggregate) as in sub base to floor, in foundation or mass filling or similar works complete all as specified and directed. |
| 18 | M&L for 25 mm thick sand cushioning under floors complete all as specified and directed. |
| 19 | M&L for 60mm thick machine pressedprecast concrete interlocking paver blocks of any shape and size ofM-35 grade confirming to IS 15658 - 2006 filled with grey cement and pigment |
| 20 | M&L for 100 mm thick cement concrete type D-21:4:8 (40mm graded aggregate) as in sub base to floor or for laying of floor finishes or similar works complete all as specified and directed. |
| 21 | M&L coloured chequered cement concretetiles of size 300mm x 300mm x 20 mm, set, jointed and pointed in neat cement slurry with grey cement and pigment in floors thick laid over and including 20 mm thick screed bed in CM 1:4 bedded and jointed in neat cement slurry complete all as specified and directed. |
| 22 | M&L for 150 mm thick Cement concrete work type B-1 (1:2:4) (using 20mm graded aggregate) for pavement/ hardstanding and flooringor similar works finished even and smooth without using extra cement including necessary form work complete all as specified and directed. |
| 23 | M&L for forming Contraction (Dummy) joints 65mm deep x 10 mm wide, filledwith sealing compound, Grade \"A\" complete all as specified and directed. |
| 24 | Taking down cement or cement plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 25 | M&L for rendering 15mm thick cement plaster on fair faces of brick work on concrete surfaces in cm (1:4) rendering to be finished even and smooth without using extra cementcomplete all as specified and directed by Engr-in-Charge. |
| 26 | Dewatering and cleaning of septik tank/soakwell/soak pits /manhole etc incl removing sludge ,waste material by means of motorised suction machine and disposing off the waste out side MOD land complete all as specified and directed by Engineer in charge. |
| 27 | Cleaning of sewage line upto 100mm dia pipe PVC/SWG over or under ground and removing sewage by rodding using bamboo or by machanical means from WC to first manhole ,nahani traps to gully traps,gully traps to manholetogether with vertical stecks pipes (where reqd ) Cleaning eye to gully traps and taking out all debris,or any solid materials from sewage line and removing the debris from site and flushing with water man hole to manhole and testing after cleaning completefor pipe lines complete all as specified and directed by engineer in charge |
| 28 | Cleaning of blocked/filled WC, GT, NT any type and cleaning of freezed water if any and accumalated sludge by heating method with blow lamps or any other method and rodding the cast iron pipe75 mm bore and 150 mm boreSWG/PVC/CI pipe Upto first manhole without damaging the WC and Pipecomplete all as specified and directed by Engineer in charge |
| 29 | Demolition of brick or stone/ concrete block/ stone boulder masonary built in cement mortar incl all quoins, arches, pillars etc., but excluding ashlar facings, dressed stone works and precast cement articles, complete all as specified and directed. |
| 30 | M&L stone wailing of random rubble, uncoursed well bounded, bedded and solidly hearted built in 1:6 brought to course complete all as specified and directed. |
| 31 | Demolition of cement concrete (reinforced) in roofs , floors ( other than ground floors ), beams, staircases, landing, chajjas and similar suspended work. |
| 32 | M&L reinforced precast cement concrete type BI 1:2:4 (Using 20 mm graded stone aggregate) as in cover slabs man hole etc and set incement mortar 1:4 complete all as specified and directed. |
| 33 | M&L RCC 1:2:4 type B1 (using 20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc. |
| 34 | M&L form work to sides and soffits of suspended slabs such as roof slabs , landings and similar work not exc 200 mm thick (horizontal or sloopping) for flat fair finished surfaces complete all as specified and directed. |
| 35 | S&F Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips |
| 36 | S&F Mild steel TMT6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips |
| 37 | S&F in repairs vitreous ChinaSquatting pan \"Orrisa\"pattern size 580x440mm white with integral foot rest,and jointing to PVC/CI bend and flush pipe complete including making good to floorall asspecified. |
| 38 | S & F in repair Vitreous China wash down pedestal pattern EWC, white and plastic water closet pan and trap includingconnection to drain and to flushing pipe antisyphonage pipe etc, jointing to PVC/CI and flush pipe including making good to floor complete all as specified and directed. |
| 39 | Demolition or cement concrete (unreinforced) incl floor finish in ground floors and pavings n. exc 15cm thickness (below or above ground level) |
| 40 | M&L for 25 mm thick cement concrete type B-2 1:2:4 (20mm graded aggregate) as in floor or similar works complete all as specified and directed. |
| 41 | M&L for non skid coloured ceramic tiles 7 to 8 mm thick (Square/ rectanglar) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 42 | Demolition and breaking up drain pipe (salt glazed stone water or AC) of any dia set in cement mortar, complete all as specified and directed. |
| 43 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors bore of pipe 110 mm complete all as specified and directed. |
| 44 | S&F PVC (SWR) bend 110mm bore complete all as specified and directed. |
| 45 | Deduct Credit for Demolished/Dismantled material Rs (-) 49,600.00 (Minus) as listed in Schedule \"A\" Sec-II (Credit Schedule)Note :Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the \"Contract Sum\". |