| 1 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations of poles etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, leveling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed. |
| 3 | Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 4 | Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and leveling complete all as specified and as directed. |
| 5 | Supply and laying sub class B bricks of size230x125x73mm (+/- 10% tolerance limit) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed. |
| 6 | Laying only old burnt old size bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cable for protection complete all as specified and as directed. |
| 7 | Horizontal boring suitable for 50mm bore steel tubing, under road/ pavement / hard standing etc. not exceeding 10 Metres in length, in any type of soil, suitable for passing through up to 50 mm bore, galvanised steel tubing complete all as specified and as directed. |
| 8 | Supplying and fixingGalvanised mild steel pipe /tubing,light grade complete with all fittings of 40 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers as in cable protection complete all as specified and as directed. |
| 9 | Disconnecting & taking out defective under ground LT cable from trenches, pole, pipe,floor ,wall etc including bricks ,GI pipes and removing from work site of unserviceable material and keep serviceable material for reuse in safe custody of any size complete all as specified and as directed. Note: Excavation/earth work shall be measured & paid separately under relevant item of this Schedule. |
| 10 | Supply, laying ,jointing andtestingLT underground electric power cable crossed linked XLPE insulated, two or more core galvanized steel strip or wire armoured / PVC insulated armoured cableheavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 16 sqmm 4 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts or passing through pipesetc fixing and connecting accessories such as Aluminium cable lugs, cable glands, nut, bolts, washers etc complete all as specified and as directed. Note: Sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items. |
| 11 | Supply, laying ,jointing andtestingLT underground electric power cable crossed linked XLPE insulated, two or more core galvanized steel strip or wire armoured / PVC insulated armoured cableheavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 10 sqmm 4 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts or passing through pipesetc fixing and connecting accessories such as Aluminium cable lugs, cable glands, nut, bolts, washers etc complete all as specified and as directed. Note: Excavation, earth work, sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items. |
| 12 | Relaying in trenches or passing through pipe, 1100 volts grade,LT electric power UG cables, of any type/Size with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. Note: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this Schedule \"A\". |
| 13 | Supply and fixing in repairs street light bracket made out of GI pipe light grade 32 mm dia 1.2 mtr length bent to shape and reduced to required size at top upto 1.5 mtr length by cutting, welding and well finishing including MS clamp of flat iron of size 40 x 6 mm suitable length 2 Nos complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer complete all as specified and as directed. |
| 14 | Material and labour for LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 4500 lumen, system wattage 45 Watt, Ingress protection IP-66 with all accessories including taking down unserviceable light fitting and removing from site complete all as specified and as directed. |
| 15 | Material and labour for LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 6000 lumen, system wattage 60 Watt, Ingress protection IP-66 with all accessories including taking down unserviceable light fitting and removing from site complete all as specified and directed. |
| 16 | Material and labour for LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 9000 lumen, system wattage 90 Watt, Ingress protection IP-66 with all accessories including taking down unserviceable light fitting and removing from site complete all as specified and directed. |
| 17 | Material and labour for LED floodlight epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 10000 lumen, system wattage 100 Watt, Ingress protection IP-66 with all accessories including taking down unserviceable light fitting and removing from site complete all as specified and as directed. |
| 18 | Material and labour for LED floodlight epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 20000 lumen, system wattage 200 Watt, Ingress protection IP-66 with all accessories including taking down unserviceable light fitting and removing from site complete all as specified and as directed. |
| 19 | M&L for Pyramid tripod type LED Bollard garden light 10W (Warm White) with 3600 light distribution (Make : Crompton, Cat No. LBLSN-10WW or techno commercially equivalent make as listed in List of Makes and as approved by the GE) made up of high grade unbreakable polycarbonate material, IP-65 protection including taking out old unserviceable garden light fittings complete all as specified and as directed. |
| 20 | Material and labour for Digging out incoming and outgoing cables of any sizes from loop near junction box/ feeder pillar box in tranches, cutting burntout uninsulated portion of cable and rectify the defect and relaying the XLPE cable under ground aluminium conductor in trenches and returning and filling the excavated soil and connecting the cables with bus bars including provision of lugs as applicable and testing complete all as specified and as directed. |
| 21 | Supply and fixing loop in- loop out fuse junction box of internal dimension 250 x 200 x 100mm made of FRP sheet with weather proof canopy and locking screw fitted with and including50 Amp rated 4 way connectors for 3 phase and neutral incoming/outgoing , mounted in the box, fixing on street pole/rail poles including necessary aluminium clamps, suitable glands, lugs and GI nut and bolt and 01 SP of 6 Amp for controlling including taking down old unserviceable junction box complete all as specified and as directed. Make:Sintex, Cat Part No. GSJB-2520 or techno commercially equivalent as listed in List of Makes as approved by the GE.Note: Contractor shall provide cable lugs andPVC gland of suitable size if required on site for connecting cable in junction box. |
| 22 | Supplying and fixing in repair single run 3 core ,2.50 sqmm nominal cross sectional areamultistrandedcopper conductor cable, over all PVC sheathed, 1100 Volts grade confirming to IS-694-2010 (FRLS) heavy dutycable PVC insulatedand PVC sheathed from pole junction box to light fitting complete all as specified and as directed. |
| 23 | Supply and fixed in repairs 20 mm nominal bore dia, UPVC pipes of pressure rating 10 kgf/cm2 fixed to pole, any type including provision MS clamp of size 20mm x 3mm flat at interval of 1.5 m length complete all as specified and as directed. |
| 24 | Supply and fixing in repair power contractor 40 amps 3 pole (1NO + 1 NC) , 415 Volts AC 50Hz,including connecting with existing system complete all as specified and as directed. |
| 25 | Supply and fixed in repair of Astronomical Digital Time switch(5-40) Amps, 240 Volts, AC, single phase complete all as specified and as directed. |
| 26 | Material and labour for disconnection of all electric connection and taking down of street light fittings of any type, size, capacity and model removing of unserviceable spares or accessories for repair/ replacement of the same including reconnecting and refixing of street light to its existing position viz pole / high mast andtesting complete all as specified and as directed. |
| 27 | Supply and fixing in repair electronic driver suitable for 60 Watts LED street light fittings of approved make / brand complete all as specified and as directed. |
| 28 | Supply and fixed in repairs MCB TPN 63 Amps, \"C\" series 10kA, 415 Volts and to be housed in DBscomplete including necessary connectionall as specified and directed. Note: Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating. |
| 29 | Supply, installation and testing of outdoor Time line distribution board for street light , degree of protection IP 54, three phase, maximum load 12 kW, prewired with Digital timer switch, contactor TP rating 65 Amp and MCB Triple pole & neutral rating 63 Amp complete all as specified and as directed. |
| 30 | Material and labour for steel tubular poles (Swan neck street light pole) complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 SP-31, 9.0 meter long including painting all external exposed steel surfaces with two coats of aliminium paints over a coat of red oxide zinc chrome primer and all internal surfaces and external surfaces in contact with concrete with two coats of black bituminous paint complete all as specified and as directed including taking down old existing concrete poles / struts any size after demolition of foundation and depositing / stacking at a place where directed within 5kM distance from the work site complete all as specified and as directed. |
| 31 | M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate for foundation of stay assembly/struts/pole etc. (around the poles in pit) complete all as specified and as directed. |
| 32 | M&L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate for coping /pedestal of poles including necessary form work, fair finishing to exposed surfaces by using extra cement complete all as specified and as directed. |
| 33 | M & L Painting to the LT RCCpoles with strips in alternate from bottom to top with three strips of black syntheticpaint & two strips of Yellow/ Sky blue paint (as per existing pattern) through out the circumference of poleincluding one coat of Lime wash on PCC copping of pole , two coat ofwhite colour cement base Distemper on pole and two coat ofaluminium paint to channels, cross arm, clamps and pipes fixed/ mounted on pole after scratching out old paint, cleaning and making exiting surface rust free, preparation of the existing surface,including marking pole numbers in a 15 cm dia yellow circle with number writing with blacksyntheticpaint/ sticker complete all as specified and as directed. |
| 34 | M & L Painting ofsteel pole (swan neck type or straight type) up to 12 mtr heightwith cross arms, clamp of any length and shape for LT overhead line/ for street lightwith two coat of aluminium paint after scratching out old paint, cleaning and exiting surface rust free, preparation of the existing surface,including marking pole numbers in a 15 cm dia yellow circle with number writing with blacksynthetic paint/ Sticker, includingpainting strips in alternate from bottom to top with three strips of black syntheticpaint & two strips of Yellow/ Sky blue paint(as per existing pattern through out the circumference of pole, including removing extra wall papdi ,peel off wall papdi by sand paper and makinggood with putty as per existing thickness and applying one coat of white washing on PCC copping of pole and re-numbering of pole with approved size of letter (Example - P- 001) with synthetic enamel paint of white colour background and black colour lettering complete all as specified and as directed. |
| 35 | M&L for repairing of mechanism of lowering down and hoisting of flood light cage (mobile Head frame) of High mast assy of 16 mtr height, repairing, servicing of hoisting motor assy, repairing of chain, greasing of moving parts and replacement of steel rope, pulley ,repairing of elevator wrench system etc, relaying of rope from top to bottom and making the mechanism functional complete all as specified and as directed. |
| 36 | M&L for winding of induction motor of single phase, 1 HP, 240 V, 50 Hzof High mast of hoisting and lowering mechanism of flood light cage with super enameled winding wire of existing gauge , replacement of bearing as per existingetcto make the motor functional complete all as specified and as directed. |
| 37 | M&L for repairing of Control Panel of High mast assy, repair / replacement of unserviceableparts like MCB, Contractor, auto manual switch, NO + NC switch, starter motor, replacement of u/sindicators, start stop switch, repairing and complete wiring of panel with min 1.5 Sqmm wire complete all as specified and as directed. |
| 38 | Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, check nuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing on complete all as specified and as directed. |
| 39 | M&L for cross arms, bracing, support, clamps and back plates fabricated from structural steel section including nuts, bolts, washer , welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed including GI clamp and including of one primer coat , one under coat and one finishing coat of synthetic enamel paint complete all as specified and as directed. |
| 40 | S & F 100volts grade heavy duty cable PVC insulated aluminium conductor of size 6Sqmm standard conductor, served with inner sheathing of PVC tape and overall PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circulate complete all as directed by Engineer-in Charge |