Public Administrative Department Government Departments Closing in 0 days TDR #45164608

Tender For Gmdic And In Office Electrification Work Varvansi, 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit,With

Issued by Government Departments · kanpur, Uttar Pradesh
Tender Value
8.10 Lakhs
Estimated cost
Bid Submission
17 Sep 2024
0 days left
EMD
8200
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kanpur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Gmdic And In Office Electrification Work Varvansi, 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 2 Group C 3 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 4 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 5 Submains : 6 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 7 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 8 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 9 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 10 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 11 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 12 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 13 Supplying and drawingCo axial TV cable, RG-6 grade, 0.7 mm solid copper conductor, shieldedwith fine tinned copper braid and protected with PVCsheathin the existing surface/recessed steel/PVC conduit as required. 14 Supplying and fixing of following sizes of medium class PVC conduit along with accesMRies in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 15 20 mm 16 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 17 5/6 A switch 18 3 pin 5/6 A socket outlet 19 TV antenna socket outlet 20 Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 21 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 22 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 23 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 24 1 or 2 Module (75mmX75mm) 25 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 26 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 27 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 28 Upto 450 mm sweep 29 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 30 2 Pair 31 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 32 1 run of cable 33 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 34 MCBs & DB’s : 35 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 36 6 way (4 + 18), Double door 37 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 38 Single pole 39 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 40 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 41 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 42 ELCB/RCCB Switches : 43 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 44 40 A 45 63 A 46 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 47 Earthing Work : 48 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accesMRies, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 49 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 50 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 51 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 52 100 mm dia 53 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accesMRies including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 54 L.T. Switch Panel Board : 55 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. 56 The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. 57 The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type 58 CUBICAL PANEL BOARD ( MCCB TYPE ) 59 PANEL 60 Incoming - 61 200 Amp MCCB-1 No. 62 Bus-Bar - 63 200 Amp /415 Volt MCCB -1 No. 64 Outgoing - 65 63 Amp 4P MCCB - 2 Nos. (for power d.b.) 66 40 Amp 4P MCCB - 4 Nos. (for light d.b.) 67 63 Amp 4P MCCB - 1 Nos. (Spare) 68 40 Amp 4P MCCB - 1 Nos. (Spare) 69 (or As per requirment directed by Project Manager.) 70 Lighting Fixtures (Lights/Fans) : 71 Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver set complete in all respect.CAT. - AAA 72 Supply and fixing of 3 watt to 6 watt LED(spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA (Use as a Decorative Mirror Light) 73 Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect CAT. - AAA 74 Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA 75 Armoured Cables (Cable/Gland/Lug) : 76 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 77 size 95 sq mm x 3-1/2core 78 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable 79 size 95 sq mm x 3-1/2core 80 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 81 size 50 sq mm 82 size 95 sq mm 83 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. 84 Non-Schedule Items 85 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 86 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 87 LESS 5.0% DUE TO DEPTT. WORKING

BOQ

Name of Work GMDIC AND IN OFFICE ELECTRIFICATION WORK VARVANSI
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2Group C
3Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
4Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
5Submains :
6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
72 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
82 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
92 X 4 sq. mm + 1 X 4 sq. mm earth wire
102 X 6 sq. mm + 1 X 6 sq. mm earth wire
114 X 6 sq. mm + 2 X 6 sq. mm earth wire
124 X 10 sq. mm + 2 X 6 sq. mm earth wire
13Supplying and drawingCo axial TV cable, RG-6 grade, 0.7 mm solid copper conductor, shieldedwith fine tinned copper braid and protected with PVCsheathin the existing surface/recessed steel/PVC conduit as required.
14Supplying and fixing of following sizes of medium class PVC conduit along with accesMRies in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1520 mm
16Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
175/6 A switch
183 pin 5/6 A socket outlet
19TV antenna socket outlet
20Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
21Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
22Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
23Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
241 or 2 Module (75mmX75mm)
25Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
26Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
27Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
28Upto 450 mm sweep
29Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
302 Pair
31Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
321 run of cable
33Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. (for A.C. Point/MCB Point)
34MCB\"s & DB’s :
35Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
366 way (4 + 18), Double door
37Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
38Single pole
39Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
40Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A
41Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A
42ELCB/RCCB Switches :
43Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
4440 A
4563 A
46Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
47Earthing Work :
48Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accesMRies, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
49Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
50Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
51Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.
52100 mm dia
53Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accesMRies including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
54L.T. Switch Panel Board :
55Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB\"s (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects.
56The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides.
57The MCCB\"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type
58CUBICAL PANEL BOARD ( MCCB TYPE )
59PANEL
60Incoming -
61200 Amp MCCB-1 No.
62Bus-Bar -
63200 Amp /415 Volt MCCB -1 No.
64Outgoing -
6563 Amp 4P MCCB - 2 Nos. (for power d.b.)
6640 Amp 4P MCCB - 4 Nos. (for light d.b.)
6763 Amp 4P MCCB - 1 Nos. (Spare)
6840 Amp 4P MCCB - 1 Nos. (Spare)
69(or As per requirment directed by Project Manager.)
70Lighting Fixtures (Lights/Fans) :
71Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver set complete in all respect.CAT. - AAA
72Supply and fixing of 3 watt to 6 watt LED(spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA (Use as a Decorative Mirror Light)
73Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect CAT. - AAA
74Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA
75Armoured Cables (Cable/Gland/Lug) :
76Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size
77size 95 sq mm x 3-1/2core
78Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable
79size 95 sq mm x 3-1/2core
80Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable
81size 50 sq mm
82size 95 sq mm
83Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules.
84Non-Schedule Items
85Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect.
86Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect.
87LESS 5.0% DUE TO DEPTT. WORKING

AI Tender Summary

OUR REF NO 45164608
AUTHORITY Government Departments
TENDER VALUE 8.10 Lakhs
LAST DATE 17-09-2024
Authority
Authority Name Uttar Pradesh Small Industries Corporation Limited
Work Description Tender For Gmdic And In Office Electrification Work Varvansi, 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 2 Group C 3 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 4 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 5 Submains : 6 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 7 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 8 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 9 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 10 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 11 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 12 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 13 Supplying and drawingCo axial TV cable, RG-6 grade, 0.7 mm solid copper conductor, shieldedwith fine tinned copper braid and protected with PVCsheathin the existing surface/recessed steel/PVC conduit as required. 14 Supplying and fixing of following sizes of medium class PVC conduit along with accesMRies in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 15 20 mm 16 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 17 5/6 A switch 18 3 pin 5/6 A socket outlet 19 TV antenna socket outlet 20 Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 21 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 22 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 23 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 24 1 or 2 Module (75mmX75mm) 25 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 26 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 27 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 28 Upto 450 mm sweep 29 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 30 2 Pair 31 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 32 1 run of cable 33 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 34 MCBs & DB’s : 35 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 36 6 way (4 + 18), Double door 37 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 38 Single pole 39 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 40 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 41 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 42 ELCB/RCCB Switches : 43 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 44 40 A 45 63 A 46 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 47 Earthing Work : 48 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accesMRies, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 49 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 50 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 51 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 52 100 mm dia 53 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accesMRies including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 54 L.T. Switch Panel Board : 55 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. 56 The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. 57 The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type 58 CUBICAL PANEL BOARD ( MCCB TYPE ) 59 PANEL 60 Incoming - 61 200 Amp MCCB-1 No. 62 Bus-Bar - 63 200 Amp /415 Volt MCCB -1 No. 64 Outgoing - 65 63 Amp 4P MCCB - 2 Nos. (for power d.b.) 66 40 Amp 4P MCCB - 4 Nos. (for light d.b.) 67 63 Amp 4P MCCB - 1 Nos. (Spare) 68 40 Amp 4P MCCB - 1 Nos. (Spare) 69 (or As per requirment directed by Project Manager.) 70 Lighting Fixtures (Lights/Fans) : 71 Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver set complete in all respect.CAT. - AAA 72 Supply and fixing of 3 watt to 6 watt LED(spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA (Use as a Decorative Mirror Light) 73 Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect CAT. - AAA 74 Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA 75 Armoured Cables (Cable/Gland/Lug) : 76 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 77 size 95 sq mm x 3-1/2core 78 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable 79 size 95 sq mm x 3-1/2core 80 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 81 size 50 sq mm 82 size 95 sq mm 83 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. 84 Non-Schedule Items 85 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 86 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 87 LESS 5.0% DUE TO DEPTT. WORKING
Basic Detail
Tender No 21/EE7/UPSIC/24-25
Bidding Type Tender
Location
City kanpur
State Uttar Pradesh
Key Dates
Publish Date 10 Sep 2024
Submission Date 17 Sep 2024
Open Date 17 Sep 2024
Finance
Tender Value 8.10 Lakhs
Tender Fee 590
EMD 8200
Exemption Not Available
Document List
8c45595e-6f01-4671-a325-41d6a0976c03.html
04.pdf
BOQ_1657564.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 17, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 17, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

8c45595e-6f01-4671-a325-41d6a0976c03.html

pdf

04.pdf

xls

BOQ_1657564.xls

pdf

Tendernotice_1.pdf

TenderDetail