Tender For Construction Of Hostel Building In Kgbv, Khuard
Tender Value
84.47 Lakhs
Estimated cost
Bid Submission
25 Sep 2024
0 days left
EMD
84475
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaleswar → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Construction Of Hostel Building In Kgbv, Khuard
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in hard soil or gravelly soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge. |
| 2 | Filling in foundation and plinth with sand watered and rammed. |
| 3 | Cement concrete 1:3:6 with 40mm hard granite crusher broken metal. |
| 4 | R.C.C. work of M-20 grade with 20mm and down grade black hard granite (crusherbroken) stone chips including hoisting and laying. |
| 5 | Ground Floor |
| 6 | First Floor |
| 7 | Supplying ,fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification. |
| 8 | Ground Floor |
| 9 | First Floor |
| 10 | Rigid and smooth centering and shuttering for R.C.C works including false works and dismentaling then after casting including cost of materials complete. |
| 11 | Ground Floor |
| 12 | Foundation & Plinth |
| 13 | Column & Beam |
| 14 | Lintel |
| 15 | Roof Slab, Chajjas |
| 16 | Staircase |
| 17 | First Floor |
| 18 | Column & Beam |
| 19 | Lintel |
| 20 | Roof Slab, Chajjas |
| 21 | Staircase |
| 22 | Brick work with Fly Ash bricks 25cm x 12cm x 8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ±8 percent in cement mortar (1:6) in foundation and plinth per cum. |
| 23 | Brick work with Fly Ash bricks 25cm x 12cm x 8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ±8 percent in cement mortar (1:6) in Super Structure per cum. |
| 24 | Ground Floor |
| 25 | First Floor |
| 26 | 12mm thick cement plaster (1:6) for brick work. |
| 27 | Ground Floor |
| 28 | First Floor |
| 29 | 16mm thick cement plaster (1:6) over brick or stone work. |
| 30 | Ground Floor |
| 31 | First Floor |
| 32 | 6mm thick cement plaster (1:4) to R.C.C surface finished smooth including closed deep chipping and slury treatment. |
| 33 | Ground Floor |
| 34 | First Floor |
| 35 | 20mm thick cement plaster (1:4) over roof top as grading plaster. |
| 36 | Supplying prefabricated G.I. Door, Window, Grill, Ventilator etc. and fixing it in specified place as mentioned in the drawing including all cost and charges complete. |
| 37 | Ground Floor |
| 38 | First Floor |
| 39 | Supplying, fitting and fixing vitrified tile in floors of size 600mm*600mm of approved make confirming to IS : 13755laid on 20 mm thick cement mortar (1:4) and filling joints with white cement of approved quality includingcost of all materials, labour required for the work all complete as per direction of Engineer-in-Charge. (For New work only) |
| 40 | Ground Floor |
| 41 | First Floor |
| 42 | Fixing vitrified tiles in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete including cost of tiles. |
| 43 | Ground Floor |
| 44 | First Floor |
| 45 | Fixing ceramic wall tiles in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete including cost of tiles. |
| 46 | Ground Floor |
| 47 | First Floor |
| 48 | Fixing tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of tiles. |
| 49 | Ground Floor |
| 50 | First Floor |
| 51 | Priming 1 coat with any approved primer on plastered surface. |
| 52 | Ground Floor |
| 53 | First Floor |
| 54 | Finishing surface of walls with Cement based wall putty (Water based ) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials and labour complete. |
| 55 | Ground Floor |
| 56 | First Floor |
| 57 | Wall painting two coats with plastic emulsion paint of approved shade on newwork to give an even shade including cost of paint. |
| 58 | Ground Floor |
| 59 | First Floor |
| 60 | Wall painting two coats with weather coat paint of approved shade on newwork to give an even shade including cost of paint. |
| 61 | Ground Floor |
| 62 | First Floor |
| 63 | Priming 1 coat with any approved primer on iron/steel surface. |
| 64 | Ground Floor |
| 65 | First Floor |
| 66 | Painting two coats over a coat of primer with approved enamel paint on new wood/ iron work. |
| 67 | Ground Floor |
| 68 | First Floor |
| 69 | Supplying, fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 70 | Ground Floor |
| 71 | First Floor |
| 72 | Supplying, fitting and fixing of openable Aluminum doors with door frame of approved make with 5mm thick ACP sheet of approved quality complete with frame, shutters and all fitting and fixtures. |
| 73 | Ground Floor |
| 74 | First Floor |
| 75 | Supplying, fitting & fixing of Stainless steel of 304 grade in hand railing using 50 mm dia of 2 mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr. C/C and stainless square pipe bracing of size 32mmx 32mm x2mm in 3 rows in staircase as per approved design and specification, buffing, polishing etc with cost. conveyance. taxes of all materials, labour, T&P etc. required for the complete in all respect. |
| 76 | Ground Floor |
| 77 | First Floor |
| 78 | Supplying, fitting and fixing vitrified industrial floor tile of premium grade having thickness 8mm to 10mm of size 300mm*300mm of approved make confirming to IS : 4457laid on 20 mm thick cement mortar (1:4) and filling joints with white cement of approved quality includingcost of all materials, labour required for the work all complete as per direction of Engineer-in-Charge. |
| 79 | Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5 sq.mm FRLS PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5Amp, 250V modular type switch ISI marked and modular ceiling rose ISI marked mounted on modular GIbox having front modularcover plate of suitable size, modular GIbox with 1.5 sq.mm FRLS PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire- Polycab/Havells/Achor/Eq.)(Make of switch- Legrand/Schneider/Panasonic/Eq.) |
| 80 | Group-AL.P. |
| 81 | Group-BL.P. |
| 82 | Group-CL.P. |
| 83 | Group-AF.P. |
| 84 | Group-BF.P. |
| 85 | Group-CF.P. Ex. F.P.- 50 |
| 86 | Group-CCall BellPt-4 |
| 87 | S/F of Modular Computer point consisting of 3 no. of 6/16 Ampswitch and sockets(Make- Legrand/Wipro/Havells/Eq.) |
| 88 | S/F of 6 Amp modular switch and socket on existing board(Make- Legrand/Wipro/Havells/Eq.) |
| 89 | S/F of 6/16 Amp modular switch and socket on separate board(Make- Legrand/Wipro/Havells/Eq.) |
| 90 | S/F of AC point modular type including 15 Amp socket, starter,32 Amp DP MCB and top as required(Make- Legrand/Wipro/Havells/Eq.) |
| 91 | Recessed wiring to submain in the following sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in the following mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with the following sq.mm FR PVC insulatedsingle core multistrand copper conductoras earth wire as required.(Make of wire-Finolex/L&T/Anchor/Havells/V-Guard//HPL/Eq. |
| 92 | 2 X 1.5 sq.mm +1 X 1.5 sq.mm in 20 mm dia |
| 93 | 2 X 2.5 sq.mm +1 X 1.5 sq.mm-do- |
| 94 | 2 X 4 sq.mm +1 X 1.5 sq.mm -do- |
| 95 | 2 X 6 sq.mm +1 X 2.5 sq.mm in 25mm dia |
| 96 | Supply and fixing of following way double pole/ triple pole steel MCB distribution board 240/400 V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Make-L&T/C&S/Legrand/ABB/Eq. |
| 97 | 12 way double door SP DB |
| 98 | 63 Amp DP MCB |
| 99 | 5amp-32 Amp SP mcb B/C series |
| 100 | S/F of 18 watt LED ceiling/surface light Make- Bajaj/Crompton/Philips/Eq. |
| 101 | S/F of 9/10 watt LED bulb Make- Bajaj/Crompton/Philips/Eq. |
| 102 | S/F of45 watt LED street light Make- Bajaj/Crompton/Philips/Eq. |
| 103 | S/F of 12 watt LED BH Fitting Make- Bajaj/Crompton/Philips/Eq. |
| 104 | S/F of ceiling fan 48\" Make- USHA/Bajaj/Crompton/Eq. |
| 105 | S/F of exhaustfan300mmMake- USHA/Bajaj/Crompton/Eq. |
| 106 | S/F of ceiling fan modular regulator Make- L&T/Roma/Havells/Eq. |
| 107 | S/F of modular angle holder as per the direction of Engineer-in-charge |
| 108 | S/F of call bell as per the direction of Engineer-in-charge |
| 109 | Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made Irom ISI marked seamless cylindci continuing to IS: 7285. fitted with ISI marked controlled valve continuing to IS: 3224. high pressure Imtr discharge hose it horn complete with initial gas charged with carry i ng handle it wall mounting s per direction of Engineer in charge. Make- Safex/Ceasefire/Minimax or equivalent |
| 110 | SITC of Inverter 1050 VA Luminous with Battery of 160 AH( Luminous/ Excide or any reputed make) |
| 111 | S/F of battery stand |
| 112 | 250Amp DG Sub- Panel For 5th Floor |
| 113 | SUPPLY AND FIXING OF 1no. of cubicle panelof 2mm thick CRCA panel box of follwing dimensuion:-0.5m x 0.5 m(30 cm depth)= 0.25 sqmtrin complete fabrication of metal clad,powder coated,compartmentalised cubicle panel as per CPWD Electrical specification including insulated busbars,supports,interconnections,erection of switchgears and making provisions of incoming/outgoing cables etc.- |
| 114 | S/F of Ammetter (0 to 500A) with selecter switch including Make- AE all accessories, Make - A.E./L&T/C&S or equivalent |
| 115 | S/F of Voltmeter(0 to 500A) with selecter switch including all accessories, Make - A.E./L&T/C&S or equivalent |
| 116 | S/F ofIndicator lamp with toggle switch and fuse. Make- A.E./L&T/C&S or Equivalent |
| 117 | S/F of C.T. Coll upto 400/5amps including all connection. |
| 118 | S/F of 100 Amp 30 KA 4 PoleMCCB with adjustable setting thermal range of 80-100 Amp. (L&T/C&S/Legrand/ABB/Eq.) |
| 119 | Provision for cable glands,lugs, cable marker etc. |
| 120 | Supply of followingAl.PVC Armoured Cable (make-Polycab/KEI/Havells/Eq.) |
| 121 | 35 sqmm. 3.5 core cable |
| 122 | Cable laying in ground with protective covering for cable exceeding 25 sqmm. but not exceeding 120 sqmm. |
| 123 | Supply and fixing of copper plate earthing 600mm x600 mmx3.15 mm thick ISImarked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc including required salt and charcoal as required. |
| 124 | S/L of 8 swg Cu wire in ground |
| 125 | Providing and fixing of lightning conductor finial made of 25 mm dia 900 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required |
| 126 | Reveting, sweating and soldering of copper / G.I. tape per 10 mtr ( with another copper / G.I. tape, base of the finial or any other metallic object) as required. |
| 127 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 128 | Providing and fixing of G.I. tape 20 mm x 3 mm thickon parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 129 | S/L of 3 mtr. Long 40 mm dia G.I. Standard Earthingwith saltand charcoal complete in all respect including cover plate etc. for lightning arrestor |
| 130 | Providing and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required. |
| 131 | Floor insulating rubber mat 6\"x4\"x6 mm |
| 132 | Supplying all labour T&P for earth work in excavation in pipe line treanches and foundation & plinth in all kind of soil within initial lead and lift including rough dressing and leveling the bed within 50m lead etc. complete as per direction of Engineer-in-Charge. |
| 133 | 110mm OD PVC |
| 134 | 40mmASTM Sch-80 pipe |
| 135 | Supplying all materials, labour, T&P etc. and laying in treanches PVC pipes of following nominal size for sewer line andfittings incl. testing as per specification complete (Excl. earthwork but including cost of pipes & fittings). |
| 136 | 110mm PVC pipe (6kg/cm2) (Cost + Labour) |
| 137 | 110mm PVC coupler (6kg/cm2) |
| 138 | 110mm PVC tail piece with flange (6kg/cm2) |
| 139 | Supplying all labour, materials, T&P and for fittiingand fixing the pipeof the folowing nominal dia including cutting jointing with socket and coupler with all complete as perP.H.specification complete. |
| 140 | 110 mm dia PVC Pipe |
| 141 | 110 mm Door Bend |
| 142 | 110 mm Plain Bend |
| 143 | 110 mm Cross TEE |
| 144 | 110 mm PVC Cowel |
| 145 | 110 mm P \" Trape |
| 146 | 110 mm PVCOffset |
| 147 | 110 mm PVC Elbow |
| 148 | Supplying all labour, materials, T&P and for fittiingand fixing the ASTM pipeof the folowing nominal dia including cutting jointing with sockeing and socket with require assoseriesand gumall complete as perP.H.specification complete. |
| 149 | 40mm ASTM SCh-80 |
| 150 | 25mm ASTM Sch_80 40mm ASTM |
| 151 | 20mm ASTM Sch-80 40mm ASTM |
| 152 | 15mm ASTM Sch-80 40mm ASTM |
| 153 | Supplying all meterials labour T& P for cutting the wall with brick or stone massoneryfor taking pipe with mending good the with cost of meterials watering curing etc complete. [250mm to 300 mm thick wall] |
| 154 | Supplying all meterials labour T& P for cutting grooveintrenches inthe floor for taking pipe line with mending good the with cost of meterials watering curing etc complete. [Cutting groove in trenches] |
| 155 | Supplying all meterials labour T& P for cutting groove inor hole in RCC chaja , slab , curnis for taking pipe linefor taking pipe line with mending good the with cost of meterials watering curing etc complete. [Chajja cutting] |
| 156 | Supplying all materials, labour, T&P for fitting and fixing different P.H. fixtures with theading socketing with all complete as per P.H specifications. |
| 157 | 40mm GM FWV |
| 158 | 25mm GM Stop cock |
| 159 | 15mm C.P Angle cock(Jaquar) |
| 160 | 15mm CP stop cock(Jaquar) |
| 161 | 15mm CP Long bodyBibcock(Jaq) |
| 162 | 15mmCP Pillar cock(Jaquar) |
| 163 | 12mm CP shower |
| 164 | 15mm CP Telephonic Shower(Jaq) |
| 165 | C.P Soap Holder(Jaq) |
| 166 | 25mm GM NRV |
| 167 | Health forget with flexi Tube |
| 168 | C.P.flange |
| 169 | Supplying all materials, labour, T&P for fitting and fixing of whit glazed Earthen ware squatting W.C.(OWC/EWC) with necessary fitting and fixture with P-Trape or S\" Trape including cuttitng the floor and making good the damageswith all complete as per P.H specifications. |
| 170 | E.W.C with S\" Trap (Hindware) |
| 171 | O.W.C with P. Trap(Hindware) |
| 172 | Standing Urinal (Half-Stall) |
| 173 | Squatting Urinal |
| 174 | 10lit L/D Cistern |
| 175 | Supplying all materials, labour, T&P for fitting and fixing of whit glazed Earthen waresquatting WHB of followingSizes with necessary fittinf and fixuresincluding necessryfitting and fixing of C.I bracket in theBrick or Stonnery wall tand making good the damageswith all complete as per P.H specifications. |
| 176 | 24x168WHB (Hind wear- Standard) |
| 177 | Glass Self |
| 178 | Cp Angle long nipple |
| 179 | Bevelled edge wallmirror(Supper ) |
| 180 | 12mm PVC connec pipe |
| 181 | 32mm wast pipe |
| 182 | 40mm Urinal pipe |
| 183 | Supplying all materials, labour, T&P for fitting and fixing of PVC SINTEX Tank of double layer on ist of Roof slabof followingSizes with necessary pipe line connection with hoisting and stagging fitting andwithfixuresincludingmaking good the damageswith all complete as per P.H specifications. |
| 184 | 1000 lit Sintex Tank |
| 185 | Brass Ballcock with Ball |
| 186 | Supplying all materials, labour, T & P for constructing Inspection Chamber of size 0.75m x 0.75m x 0.45m deep with RCC slab in C.C. (1:1 1/2:3), sand filing in foundation, CC (1:4:8) using 40mm size hbg metal in foundation, Brick Masonry work with Fly Ash bricks in C.M (1:3) , 12mm thick cement Plasterin CM(1:3) with cement punning to inside, Cement Flush pointing (1:3) to out side, C.C. (1:2:4) with 12mm CBHG chips for benching and channeling including E.W. Excavation of foundation & earth filling with excavated earth to outside cavity of chamber etc. complete. [Inside size 0.75x0.75x0.45m] |
| 187 | Supplying all materials, labour, T & P for constructing Manhole Chamber of size 0.90m x 0.90m x 0.90m deep with RCC slab in C.C. (1:1 1/2:3), sand filing in foundation, CC (1:4:8) using 40mm size hbg metal in foundation, Fly Ash. Brick Masonry work in C.M (1:3) , 12mm thick cement Plasterin CM(1:3) with cement punning to inside, Cement Flush pointing (1:3) to out side, C.C. (1:2:4) with 12mm CBHG chips for benching and channeling including E.W. Excavation of foundation & earth filling with excavated earth to outside cavity of chamber etc. complete. [Inside size 0.90x0.90x1.2m] |
| 188 | Supplying all materials, labour, T&P and constructing 1.20m (4\"-0\") dia and 2.55m (8\"-6\") deep Soak Pitwith dry Fly Ash. brick walling upto 2.10 mtr.(7\"-0\") Height and Fly Ash Brick masonary in C.M.(1:4) for the remaining 0.45 m (1\"-6\") height of wall at top, 12mm thick Cement Plaster in CM(1:3) inside and outside, inside filled with dry brick Khoa of sizes 40mm to a height of 1.95m. (6\"-6”) from bottom covered by means of 75mm (3 “) thick RCC perforated slab in CC(1:1 1/2:3) fitted with iron rings including Earth Work. in excavation and refilling of cavity around the pit and painting to iron worketc. as per instruction of Engineer-in-Charge. [Soak Way Pit 1.20x2.50m] |
| 189 | Supplying all materials, labour, T & P for sinking of 125mmx 60.00mt dia bore wellwit Calix method/ water jet method ( Hand Boring ) including drilling , ramming, grouting and lowering the125mm ASTM Sch-8o casine pipeand plugingat the end of the T.W. including devloping the bore well till the sand free cleanand portable water is received with plugging top of the T.W with End Capcomplete. |
| 190 | 125mmx60.00m drilling withcost of pipe assosries. |
| 191 | Commisioning of 1HP submerssible pump set,cable etc. |
AI Tender Summary
Tender Timeline
Sep 10, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedSep 25, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 26, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender