Agriculture Government Departments Closing in 0 days TDR #45148386

Tender For Repair Of Upswc Godowns At Pihani (Hardoi)-1

Issued by Government Departments · pihani, Uttar Pradesh
Tender Value
47.07 Lakhs
Estimated cost
Bid Submission
25 Sep 2024
0 days left
EMD
94200
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
pihani → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Repair Of Upswc Godowns At Pihani (Hardoi)-1

BOQ

Name of Work: Repair of Boundrywall, Campus and Office Light Work,Godown Repair Work etc at Pihani (Hardoi)-1
Sl. No. Item Description
1Repair of Boundrywall
2Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
3Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured):From brick work in cement mortar
4Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
5Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
6Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
7Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
8Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
9Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
10Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
11Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
12Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Cold twisted bars
13Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
14Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
15Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand)
1612 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
17Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used.With G.I. barbed wire
18Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete
19Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
20Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
21Campus Light and Office Light
22Supply, installation, testing and commissioning of LED street light fitting in pressure die cast aluminium body with glass/PC cover complete with inbuilt driver, accessories fixing on existing pole with having following technical specifications i/e makinf connection with 1.5 sq mm FRLS PVC insulated copper conductor single core cable and earthing,testing etc as reqd.(Make:Philips, cat No. BRP062 led 68 CW SLC S1 PSU) (i) Minimum lumen output 6500 lumen (ii) System lumen efficacy >110Lm/Watt (iv) CCT>5700,CRI>70, PF> 0.95, THD< 10%,ip 66 (v) L 70 rated life of50 K hours (vi) on built surge protection device of minimum 4 KV.
23Supply & Fixing of32 mm dia x 2.00 metres long G.I.pipe (Medium class) bracet for mounting of fluorescent/HPMV/HPSV street light fitting on pole including bending the pipe to required shape, 2 nos 40 mm x 3 mm flat iron clamps with nuts,bolts and washer, painting the flat iron with primer and finish paint etc.as required.
24Supply & laying of 3 x 10 sq. mm one number Aluminium XLPE insulated,PVC outer sheathed, armoured with galvanized round steel wire or steel strip cables with stranded aluminium conductor suitable for reted voltage 1.1 KV grade, ISI marked conferming to IS:7098 / pt.l/ 1988 with ammendment no. 1 as required.,On existing wall/surface
25Supply & laying of 3 x 10 sq. mm one number Aluminium XLPE insulated,PVC outer sheathed, armoured with galvanized round steel wire or steel strip cables with stranded aluminium conductor suitable for reted voltage 1.1 KV grade, ISI marked conferming to IS:7098 / pt.l/ 1988 with ammendment no. 1 as required.,In the existing RCC/HUME/METAL pipe.
26Supply & laying of 3 x 10 sq. mm one number Aluminium XLPE insulated,PVC outer sheathed, armoured with galvanized round steel wire or steel strip cables with stranded aluminium conductor suitable for reted voltage 1.1 KV grade, ISI marked conferming to IS:7098 / pt.l/ 1988 with ammendment no. 1 as required.,In the existing masonry open duct/loose/connection.
27Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 6 way,Double door
28Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
29Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Doublepole (40Amp)
30Providing50dia pipe(medium class)complete.
31Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
32Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
33Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
34Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
35Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
36Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
37Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc. as required.6 Module (200mmX75mm)
38Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc. as required.12 Module (200mmX150mm)
39Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
40Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
41Supplying and fixing brass batten/ angle holder including connection etc. as required.
42Supply, installation, testing and commissioning of surface type batten LED fittingminimum length 1150mm with extruded aluminium housing having following technical specifications with all accessories directly on ceiling/wall including connection with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing(i) Minimum lumen output 2000 lumen (ii) System lumen efficacy >100Lm/Watt (iii) CCT>5700,CRI>80, PF> 0.95, THD< 10%,(iv) L 70 rated life of50 K hours (v) in built surge protection device of minimum 2.5 KV.
43Godown Repair Work
44Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
45Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking.
46Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:Asbestos Cement sheet
47Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete.Close fitting adjustable ridges
48Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.|. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required.
49Refixing of old wind tie.as per direction of Engineer-in-charge.
50Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m2
51Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand)
5212 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
53Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep
54Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
55Repair of rolling shutter i/e washing of Shutter by kerosin oil, oiling gressing and tighting of spring, T & P etc Complete & as per direction of Engineer-in-charge.
56Supply of 200Ah Tall Tubular Inveter Battery with 36 month warranty.
57Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 100 mm diameter Class I
58Supply of C.I Pipe for Fire Fighting System.
59Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.

AI Tender Summary

OUR REF NO 45148386
AUTHORITY Government Departments
TENDER VALUE 47.07 Lakhs
LAST DATE 25-09-2024
Authority
Authority Name Uttar Pradesh State Warehousing Corporation Limited
Work Description Tender For Repair Of Upswc Godowns At Pihani (Hardoi)-1
Basic Detail
Tender No 20240917134-1
Bidding Type Tender
Location
City pihani
State Uttar Pradesh
Key Dates
Publish Date 09 Sep 2024
Submission Date 25 Sep 2024
Open Date 25 Sep 2024
Finance
Tender Value 47.07 Lakhs
Tender Fee 1180
EMD 94200
Exemption Not Available
Document List
e242cbb7-e55f-4679-9b06-414cbee019eb.html
BOQ_1654784.xls
pihani1.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 09, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 25, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 25, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

e242cbb7-e55f-4679-9b06-414cbee019eb.html

xls

BOQ_1654784.xls

pdf

pihani1.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender